{"id":"https://openalex.org/W2019319397","doi":"https://doi.org/10.1088/0026-1394/46/5/021","title":"A primary standard for the calibration of sniffer test leak devices","display_name":"A primary standard for the calibration of sniffer test leak devices","publication_year":2009,"publication_date":"2009-08-14","ids":{"openalex":"https://openalex.org/W2019319397","doi":"https://doi.org/10.1088/0026-1394/46/5/021","mag":"2019319397"},"language":"en","primary_location":{"id":"doi:10.1088/0026-1394/46/5/021","doi":"https://doi.org/10.1088/0026-1394/46/5/021","is_oa":false,"landing_page_url":"https://doi.org/10.1088/0026-1394/46/5/021","pdf_url":null,"source":{"id":"https://openalex.org/S7291761","display_name":"Metrologia","issn_l":"0026-1394","issn":["0026-1394","1681-7575"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["anvur-scientific","cwts-core","dongbi-b","jufo-2","norway-1","poland-70","russia-white-list-2"],"host_organization":"https://openalex.org/P4310320083","host_organization_name":"IOP Publishing","host_organization_lineage":["https://openalex.org/P4310320083","https://openalex.org/P4310311669"],"host_organization_lineage_names":["IOP Publishing","Institute of Physics"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Metrologia","raw_type":"journal-article"},"volume":null,"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5023681575","display_name":"Karl Jousten","orcid":"https://orcid.org/0000-0003-1173-1514","observed_orcids":["https://orcid.org/0000-0003-1173-1514"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Karl Jousten","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"last","author":{"id":"https://openalex.org/A5039922814","display_name":"Ute Becker","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Ute Becker","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":{"value":3325,"currency":"USD","value_usd":3325},"apc_paid":null,"fwci":1.65,"has_fulltext":false,"cited_by_count":19,"citation_normalized_percentile":{"value":0.84363178,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":88,"max":98},"biblio":{"volume":"46","issue":"5","first_page":"560","last_page":"568"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11890","display_name":"Scientific Measurement and Uncertainty Evaluation","score":0.9945999979972839,"subfield":{"id":"https://openalex.org/subfields/1804","display_name":"Statistics, Probability and Uncertainty"},"field":{"id":"https://openalex.org/fields/18","display_name":"Decision Sciences"},"domain":{"id":"https://openalex.org/domains/2","display_name":"Social Sciences"}},"topics":[{"id":"https://openalex.org/T11890","display_name":"Scientific Measurement and Uncertainty Evaluation","score":0.9945999979972839,"subfield":{"id":"https://openalex.org/subfields/1804","display_name":"Statistics, Probability and Uncertainty"},"field":{"id":"https://openalex.org/fields/18","display_name":"Decision Sciences"},"domain":{"id":"https://openalex.org/domains/2","display_name":"Social Sciences"}},{"id":"https://openalex.org/T12537","display_name":"Flow Measurement and Analysis","score":0.0026000000070780516,"subfield":{"id":"https://openalex.org/subfields/2211","display_name":"Mechanics of Materials"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11583","display_name":"Advanced Measurement and Metrology Techniques","score":0.001500000013038516,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/primary-standard","display_name":"primary standard","score":0.9490000009536743},{"id":"https://openalex.org/keywords/gas-flow-rate-measurement","display_name":"gas flow rate measurement","score":0.7049999833106995},{"id":"https://openalex.org/keywords/traceability","display_name":"traceability","score":0.5590000152587891},{"id":"https://openalex.org/keywords/uncertainty-budget","display_name":"uncertainty budget","score":0.8510000109672546},{"id":"https://openalex.org/keywords/r-134a","display_name":"R134a","score":0.6990000009536743}],"concepts":[{"id":"https://openalex.org/C165838908","wikidata":"https://www.wikidata.org/wiki/Q736777","display_name":"Calibration","level":2,"score":0.693488359451294},{"id":"https://openalex.org/C2987355568","wikidata":"https://www.wikidata.org/wiki/Q4420957","display_name":"Leak detection","level":3,"score":0.5915638208389282},{"id":"https://openalex.org/C2780378346","wikidata":"https://www.wikidata.org/wiki/Q1349983","display_name":"Leak","level":2,"score":0.5356388092041016},{"id":"https://openalex.org/C2777267654","wikidata":"https://www.wikidata.org/wiki/Q3519023","display_name":"Test (biology)","level":2,"score":0.5338987112045288},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.46660372614860535},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.3288726806640625},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.2755841314792633},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.22933357954025269},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.15202781558036804},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.08153557777404785},{"id":"https://openalex.org/C86803240","wikidata":"https://www.wikidata.org/wiki/Q420","display_name":"Biology","level":0,"score":0.0660804808139801},{"id":"https://openalex.org/C151730666","wikidata":"https://www.wikidata.org/wiki/Q7205","display_name":"Paleontology","level":1,"score":0.0},{"id":"https://openalex.org/C87717796","wikidata":"https://www.wikidata.org/wiki/Q146326","display_name":"Environmental engineering","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1088/0026-1394/46/5/021","doi":"https://doi.org/10.1088/0026-1394/46/5/021","is_oa":false,"landing_page_url":"https://doi.org/10.1088/0026-1394/46/5/021","pdf_url":null,"source":{"id":"https://openalex.org/S7291761","display_name":"Metrologia","issn_l":"0026-1394","issn":["0026-1394","1681-7575"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["anvur-scientific","cwts-core","dongbi-b","jufo-2","norway-1","poland-70","russia-white-list-2"],"host_organization":"https://openalex.org/P4310320083","host_organization_name":"IOP Publishing","host_organization_lineage":["https://openalex.org/P4310320083","https://openalex.org/P4310311669"],"host_organization_lineage_names":["IOP Publishing","Institute of Physics"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Metrologia","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[],"sustainable_development_goals_aurora":[],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":4,"referenced_works":["https://openalex.org/W1970591590","https://openalex.org/W2009421666","https://openalex.org/W2068927338","https://openalex.org/W2137075571"],"related_works":["https://openalex.org/W1970998101","https://openalex.org/W2010050950","https://openalex.org/W2025592237","https://openalex.org/W2021390444","https://openalex.org/W2137075571","https://openalex.org/W2058301130","https://openalex.org/W2281016553","https://openalex.org/W2094877206","https://openalex.org/W2275167516","https://openalex.org/W4226136924"],"abstract_inverted_index":{"Test":[0],"leaks":[1,27,42],"with":[2,43],"a":[3,31,68],"gas":[4,139],"flow":[5,134],"to":[6,18,59,87,91,131],"atmospheric":[7],"pressure":[8],"are":[9,16],"often":[10,102],"called":[11],"sniffer":[12,40],"test":[13,26,41,138],"leaks.":[14],"They":[15],"used":[17],"calibrate":[19],"leak":[20],"detectors":[21],"for":[22,36],"sniffing":[23],"applications.":[24],"Sniffer":[25],"need":[28],"calibration":[29,38,122],"against":[30],"standard.":[32],"A":[33],"primary":[34],"standard":[35],"the":[37,54,60,79,100,114,121],"of":[39,78,107,113,136],"relatively":[44],"low":[45],"measurement":[46,55,72,76],"uncertainties":[47],"is":[48,51,57,67,81,99],"described.":[49],"It":[50],"assured":[52],"that":[53,65],"result":[56],"traceable":[58],"relevant":[61],"SI":[62],"units":[63],"and":[64,70],"there":[66],"well-known":[69],"complete":[71],"uncertainty":[73],"budget.":[74],"The":[75,118,133],"range":[77,104,145],"system":[80],"from":[82,129],"4":[83,92],"?":[84,93],"10?11?mol?s?1":[85],"(corresponding":[86],"10?4?Pa?l?s?1":[88],"at":[89,96],"23??C)":[90],"10?9?mol?s?1":[94],"(10?2?Pa?l?s?1":[95],"23??C),":[97],"which":[98],"most":[101],"needed":[103],"in":[105,142],"industry":[106],"around":[108],"1?g":[109],"loss":[110],"per":[111],"year":[112],"cooling":[115],"agent":[116],"R134a.":[117],"temperature":[119,144],"where":[120],"can":[123,146],"be":[124,147],"carried":[125],"out":[126],"may":[127],"vary":[128],"18??C":[130],"30??C.":[132],"rate":[135],"any":[137],"not":[140],"condensing":[141],"this":[143],"measured.":[148]},"counts_by_year":[{"year":2024,"cited_by_count":1},{"year":2023,"cited_by_count":1},{"year":2021,"cited_by_count":1},{"year":2019,"cited_by_count":2},{"year":2016,"cited_by_count":1},{"year":2015,"cited_by_count":2},{"year":2014,"cited_by_count":3},{"year":2013,"cited_by_count":4},{"year":2012,"cited_by_count":1}],"updated_date":"2026-08-21T09:56:20.448147","created_date":"2016-06-24T00:00:00"}
