{"id":"https://openalex.org/W2018964150","doi":"https://doi.org/10.1109/cmd.2008.4580332","title":"New tools for diagnostic measurements on power transformers","display_name":"New tools for diagnostic measurements on power transformers","publication_year":2008,"publication_date":"2008-01-01","ids":{"openalex":"https://openalex.org/W2018964150","doi":"https://doi.org/10.1109/cmd.2008.4580332","mag":"2018964150"},"language":"en","primary_location":{"id":"doi:10.1109/cmd.2008.4580332","doi":"https://doi.org/10.1109/cmd.2008.4580332","is_oa":false,"landing_page_url":"https://doi.org/10.1109/cmd.2008.4580332","pdf_url":null,"source":{"id":"https://openalex.org/S4363608139","display_name":"International Conference on Condition Monitoring and Diagnosis (CMD)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2008 International Conference on Condition Monitoring and Diagnosis","raw_type":"proceedings-article"},"volume":null,"type":"conference-paper","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5009668134","display_name":"Michael B. Kruger","orcid":"https://orcid.org/0000-0002-6188-9179","observed_orcids":["https://orcid.org/0000-0002-6188-9179","https://orcid.org/0000-0002-0567-5301"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Michael Kruger","raw_affiliation_strings":["Omicron Electronics, Klaus","Omicron Electron., Klaus"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Omicron Electronics, Klaus","institution_ids":[]},{"raw_affiliation_string":"Omicron Electron., Klaus","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5109516288","display_name":"Maik Koch","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Maik Koch","raw_affiliation_strings":["Omicron Electronics, Klaus, Austria","Omicron Electron., Klaus"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Omicron Electronics, Klaus, Austria","institution_ids":[]},{"raw_affiliation_string":"Omicron Electron., Klaus","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5067678064","display_name":"Alexander Kraetge","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Alexander Kraetge","raw_affiliation_strings":["Omicron Electronics, Klaus, Austria","Omicron Electron., Klaus"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Omicron Electronics, Klaus, Austria","institution_ids":[]},{"raw_affiliation_string":"Omicron Electron., Klaus","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5069436227","display_name":"K. Rethmeier","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Kay Rethmeier","raw_affiliation_strings":["Omicron Electronics, Klaus, Austria","Omicron Electron., Klaus"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Omicron Electronics, Klaus, Austria","institution_ids":[]},{"raw_affiliation_string":"Omicron Electron., Klaus","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.4739,"has_fulltext":false,"cited_by_count":4,"citation_normalized_percentile":{"value":0.51191835,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":87,"max":93},"biblio":{"volume":null,"issue":null,"first_page":"488","last_page":"491"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11343","display_name":"Power Transformer Diagnostics and Insulation","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11343","display_name":"Power Transformer Diagnostics and Insulation","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10511","display_name":"High voltage insulation and dielectric phenomena","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11222","display_name":"Magnetic Properties and Applications","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2504","display_name":"Electronic, Optical and Magnetic Materials"},"field":{"id":"https://openalex.org/fields/25","display_name":"Materials Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/power-transformers","display_name":"power transformers","score":0.9980000257492065},{"id":"https://openalex.org/keywords/dissolved-gas-analysis","display_name":"dissolved gas analysis","score":0.902999997138977},{"id":"https://openalex.org/keywords/transformer-diagnostics","display_name":"transformer diagnostics","score":0.7160000205039978},{"id":"https://openalex.org/keywords/molecular-hydrogen","display_name":"molecular hydrogen","score":0.527999997138977},{"id":"https://openalex.org/keywords/hydrocarbon-gases","display_name":"hydrocarbon gases","score":0.8880000114440918},{"id":"https://openalex.org/keywords/on-load-tap-changer","display_name":"on-load tap changer","score":0.8389999866485596},{"id":"https://openalex.org/keywords/turns-ratio","display_name":"turns ratio","score":0.6660000085830688},{"id":"https://openalex.org/keywords/excitation-current","display_name":"excitation current","score":0.906000018119812},{"id":"https://openalex.org/keywords/leakage-reactance","display_name":"leakage reactance","score":0.9879999756813049},{"id":"https://openalex.org/keywords/frequency-response-analysis","display_name":"frequency response analysis","score":0.8930000066757202},{"id":"https://openalex.org/keywords/stray-losses","display_name":"stray losses","score":0.7260000109672546},{"id":"https://openalex.org/keywords/partial-discharge","display_name":"partial discharge","score":0.746999979019165},{"id":"https://openalex.org/keywords/insulation-monitoring","display_name":"insulation condition monitoring","score":0.39100000262260437}],"concepts":[{"id":"https://openalex.org/C176661527","wikidata":"https://www.wikidata.org/wiki/Q746935","display_name":"Reactance","level":3,"score":0.7279881238937378},{"id":"https://openalex.org/C66322947","wikidata":"https://www.wikidata.org/wiki/Q11658","display_name":"Transformer","level":3,"score":0.5457167625427246},{"id":"https://openalex.org/C2778282533","wikidata":"https://www.wikidata.org/wiki/Q279055","display_name":"Sulfur hexafluoride","level":2,"score":0.5262607336044312},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.516284167766571},{"id":"https://openalex.org/C30066665","wikidata":"https://www.wikidata.org/wiki/Q164399","display_name":"Capacitance","level":3,"score":0.4980306625366211},{"id":"https://openalex.org/C81818771","wikidata":"https://www.wikidata.org/wiki/Q787515","display_name":"Dissolved gas analysis","level":5,"score":0.484609454870224},{"id":"https://openalex.org/C135402231","wikidata":"https://www.wikidata.org/wiki/Q898440","display_name":"Dissipation","level":2,"score":0.48434770107269287},{"id":"https://openalex.org/C130143024","wikidata":"https://www.wikidata.org/wiki/Q1929972","display_name":"Partial discharge","level":3,"score":0.4774789810180664},{"id":"https://openalex.org/C122940293","wikidata":"https://www.wikidata.org/wiki/Q1755966","display_name":"Tap changer","level":4,"score":0.43984344601631165},{"id":"https://openalex.org/C181335627","wikidata":"https://www.wikidata.org/wiki/Q901418","display_name":"Transformer oil","level":4,"score":0.4145117998123169},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.4115055203437805},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.33712148666381836},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.3271716237068176},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.23620879650115967},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.15708759427070618},{"id":"https://openalex.org/C17525397","wikidata":"https://www.wikidata.org/wiki/Q176140","display_name":"Electrode","level":2,"score":0.08067771792411804},{"id":"https://openalex.org/C97355855","wikidata":"https://www.wikidata.org/wiki/Q11473","display_name":"Thermodynamics","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/cmd.2008.4580332","doi":"https://doi.org/10.1109/cmd.2008.4580332","is_oa":false,"landing_page_url":"https://doi.org/10.1109/cmd.2008.4580332","pdf_url":null,"source":{"id":"https://openalex.org/S4363608139","display_name":"International Conference on Condition Monitoring and Diagnosis (CMD)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2008 International Conference on Condition Monitoring and Diagnosis","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":1,"referenced_works":["https://openalex.org/W2215062468"],"related_works":["https://openalex.org/W4205564632","https://openalex.org/W1964572135","https://openalex.org/W3175130585","https://openalex.org/W4235176474","https://openalex.org/W2218153407","https://openalex.org/W2270405681","https://openalex.org/W3154704424","https://openalex.org/W3124115547","https://openalex.org/W2518583941","https://openalex.org/W2120452095"],"abstract_inverted_index":{"With":[0],"the":[1,11,43,45,59,72],"advancing":[2],"age":[3],"of":[4,10,35,93,98],"power":[5],"transformers,":[6],"a":[7,25],"regular":[8],"check":[9],"operating":[12],"conditions":[13],"becomes":[14],"more":[15,17],"and":[16,27,37,88,107,111],"important.":[18],"The":[19],"Dissolved":[20],"Gas":[21],"Analysis":[22,104],"(DGA)":[23],"is":[24],"proven":[26],"meaningful":[28],"method":[29],"such":[30],"that":[31],"if":[32],"increased":[33],"proportions":[34],"H2":[36],"hydrocarbon":[38],"gases":[39],"are":[40],"found":[41],"in":[42],"oil,":[44],"fault":[46],"must":[47],"be":[48,69],"located":[49],"as":[50,52],"soon":[51],"possible.":[53],"In":[54],"order":[55],"to":[56,68],"find":[57],"out":[58],"reason":[60],"for":[61,71],"high":[62],"gas":[63],"values,":[64],"further":[65],"tests":[66],"have":[67],"performed":[70],"transformer.":[73],"Common":[74],"test":[75],"methods":[76],"are:":[77],"Winding":[78],"resistance":[79],"measurement,":[80,91],"On-Load":[81],"Tap":[82],"Changer":[83],"(OLTC)":[84],"test,":[85],"turns":[86],"ratio":[87],"excitation":[89],"current":[90],"measurement":[92,110,115],"leakage":[94],"reactance,":[95],"Frequency":[96,102],"Response":[97,103],"Stray":[99],"Losses":[100],"(FRSL),":[101],"(FRA),":[105],"Capacitance":[106],"Dissipation":[108],"factor":[109],"Partial":[112],"Discharge":[113],"(PD)":[114]},"counts_by_year":[{"year":2021,"cited_by_count":1},{"year":2017,"cited_by_count":1},{"year":2015,"cited_by_count":1}],"updated_date":"2026-11-05T12:25:35.769452","created_date":"2016-06-24T00:00:00"}
