{"id":"https://openalex.org/W2017843646","doi":"https://doi.org/10.1109/isgteurope.2012.6465690","title":"Energy storage options for voltage support in low-voltage grids with high penetration of photovoltaic","display_name":"Energy storage options for voltage support in low-voltage grids with high penetration of photovoltaic","publication_year":2012,"publication_date":"2012-10-01","ids":{"openalex":"https://openalex.org/W2017843646","doi":"https://doi.org/10.1109/isgteurope.2012.6465690","mag":"2017843646"},"language":"en","primary_location":{"id":"doi:10.1109/isgteurope.2012.6465690","doi":"https://doi.org/10.1109/isgteurope.2012.6465690","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isgteurope.2012.6465690","pdf_url":null,"source":{"id":"https://openalex.org/S4306418803","display_name":"IEEE PES Innovative Smart Grid Technologies Europe","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2012 3rd IEEE PES Innovative Smart Grid Technologies Europe (ISGT Europe)","raw_type":"proceedings-article"},"volume":null,"type":"conference-paper","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":null,"display_name":"Francesco Marra","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4210154827","display_name":"SMA Solar Technology (Germany)","ror":"https://ror.org/04d8haw14","country_code":"DE","type":"company","lineage":["https://openalex.org/I4210154827"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Francesco Marra","raw_affiliation_strings":["Department of Technology Development, SMA Solar Technology AG, Niestetal, Germany","Dept. of Technol. Dev., SMA Solar Technol. AG, Niestetal, Germany"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Technology Development, SMA Solar Technology AG, Niestetal, Germany","institution_ids":["https://openalex.org/I4210154827"]},{"raw_affiliation_string":"Dept. of Technol. Dev., SMA Solar Technol. AG, Niestetal, Germany","institution_ids":["https://openalex.org/I4210154827"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5017832200","display_name":"Yehia Tarek Fawzy","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4210154827","display_name":"SMA Solar Technology (Germany)","ror":"https://ror.org/04d8haw14","country_code":"DE","type":"company","lineage":["https://openalex.org/I4210154827"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Y. Tarek Fawzy","raw_affiliation_strings":["Department of Technology Development, SMA Solar Technology AG, Niestetal, Germany","Dept. of Technol. Dev., SMA Solar Technol. AG, Niestetal, Germany"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Technology Development, SMA Solar Technology AG, Niestetal, Germany","institution_ids":["https://openalex.org/I4210154827"]},{"raw_affiliation_string":"Dept. of Technol. Dev., SMA Solar Technol. AG, Niestetal, Germany","institution_ids":["https://openalex.org/I4210154827"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5046512953","display_name":"T. B\u00fclo","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4210154827","display_name":"SMA Solar Technology (Germany)","ror":"https://ror.org/04d8haw14","country_code":"DE","type":"company","lineage":["https://openalex.org/I4210154827"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Thorsten Bulo","raw_affiliation_strings":["Department of Technology Development, SMA Solar Technology AG, Niestetal, Germany","Dept. of Technol. Dev., SMA Solar Technol. AG, Niestetal, Germany"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Technology Development, SMA Solar Technology AG, Niestetal, Germany","institution_ids":["https://openalex.org/I4210154827"]},{"raw_affiliation_string":"Dept. of Technol. Dev., SMA Solar Technol. AG, Niestetal, Germany","institution_ids":["https://openalex.org/I4210154827"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5028084713","display_name":"Bo\u0161tjan Bla\u017ei\u010d","orcid":"https://orcid.org/0000-0002-2424-7599","observed_orcids":["https://orcid.org/0000-0002-2424-7599"]},"institutions":[{"id":"https://openalex.org/I153976015","display_name":"University of Ljubljana","ror":"https://ror.org/05njb9z20","country_code":"SI","type":"education","lineage":["https://openalex.org/I153976015"]}],"countries":["SI"],"is_corresponding":false,"raw_author_name":"Bostjan Blazic","raw_affiliation_strings":["Department of Electrical Engineering, University of Ljubljana, Slovenia","Dept. of Electr. Eng., Univ. of Ljubljana, Ljubljana, Slovenia"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, University of Ljubljana, Slovenia","institution_ids":["https://openalex.org/I153976015"]},{"raw_affiliation_string":"Dept. of Electr. Eng., Univ. of Ljubljana, Ljubljana, Slovenia","institution_ids":["https://openalex.org/I153976015"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":4.8752,"has_fulltext":false,"cited_by_count":56,"citation_normalized_percentile":{"value":0.96334889,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":88,"max":99},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"7"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10454","display_name":"Optimal Power Flow Distribution","score":0.4611999988555908,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10454","display_name":"Optimal Power Flow Distribution","score":0.4611999988555908,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14444","display_name":"Power Systems and Renewable Energy","score":0.31299999356269836,"subfield":{"id":"https://openalex.org/subfields/2102","display_name":"Energy Engineering and Power Technology"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.1160999983549118,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/energy-storage","display_name":"energy storage","score":0.9909999966621399},{"id":"https://openalex.org/keywords/voltage-support","display_name":"voltage support","score":0.8040000200271606},{"id":"https://openalex.org/keywords/low-voltage-distribution-networks","display_name":"low-voltage distribution networks","score":0.9629999995231628},{"id":"https://openalex.org/keywords/high-photovoltaic-penetration","display_name":"high photovoltaic penetration","score":0.8769999742507935},{"id":"https://openalex.org/keywords/reactive-power-control","display_name":"reactive power control","score":0.7839999794960022},{"id":"https://openalex.org/keywords/active-power-curtailment","display_name":"active power curtailment","score":0.8500000238418579}],"concepts":[{"id":"https://openalex.org/C41291067","wikidata":"https://www.wikidata.org/wiki/Q1897785","display_name":"Photovoltaic system","level":2,"score":0.7812110185623169},{"id":"https://openalex.org/C128624480","wikidata":"https://www.wikidata.org/wiki/Q1504817","display_name":"Low voltage","level":3,"score":0.6201973557472229},{"id":"https://openalex.org/C73916439","wikidata":"https://www.wikidata.org/wiki/Q837718","display_name":"Energy storage","level":3,"score":0.6044666171073914},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.5888323187828064},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.5168148279190063},{"id":"https://openalex.org/C544738498","wikidata":"https://www.wikidata.org/wiki/Q861135","display_name":"Distributed generation","level":3,"score":0.509332537651062},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.5082008838653564},{"id":"https://openalex.org/C108755667","wikidata":"https://www.wikidata.org/wiki/Q1930258","display_name":"AC power","level":3,"score":0.48023277521133423},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4709259867668152},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.47055935859680176},{"id":"https://openalex.org/C195697387","wikidata":"https://www.wikidata.org/wiki/Q5608561","display_name":"Grid-connected photovoltaic power system","level":5,"score":0.4510107934474945},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.4401301443576813},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3496871292591095},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.30611830949783325},{"id":"https://openalex.org/C36139824","wikidata":"https://www.wikidata.org/wiki/Q1052007","display_name":"Maximum power point tracking","level":4,"score":0.2802409529685974},{"id":"https://openalex.org/C188573790","wikidata":"https://www.wikidata.org/wiki/Q12705","display_name":"Renewable energy","level":2,"score":0.2386874258518219},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0587669312953949},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C11190779","wikidata":"https://www.wikidata.org/wiki/Q664575","display_name":"Inverter","level":3,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/isgteurope.2012.6465690","doi":"https://doi.org/10.1109/isgteurope.2012.6465690","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isgteurope.2012.6465690","pdf_url":null,"source":{"id":"https://openalex.org/S4306418803","display_name":"IEEE PES Innovative Smart Grid Technologies Europe","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2012 3rd IEEE PES Innovative Smart Grid Technologies Europe (ISGT Europe)","raw_type":"proceedings-article"},{"id":"pmh:oai:pure.atira.dk:publications/4b1ccf6a-4168-490f-b153-a12a6a70f507","doi":null,"is_oa":false,"landing_page_url":"https://orbit.dtu.dk/en/publications/4b1ccf6a-4168-490f-b153-a12a6a70f507","pdf_url":null,"source":{"id":"https://openalex.org/S4306400705","display_name":"Technical University of Denmark, DTU Orbit (Technical University of Denmark, DTU)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I96673099","host_organization_name":"Technical University of Denmark","host_organization_lineage":["https://openalex.org/I96673099"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Marra , F , Tarek Fawzy , Y , B\u00fclo , T &amp; Bla\u017ei\u010d , B 2012 , Energy Storage Options for Voltage Support in Low-Voltage Grids with High Penetration of Photovoltaic . in Proceedings of IEEE PES Innovative Smart Grid Technologies (ISGT) . IEEE , 3rd IEEE PES Innovative Smart Grid Technologies (ISGT) Europe Conference (IEEE PES ISGT Europe 2012) , Berlin , Germany , 14/10/2012 .","raw_type":"contributionToPeriodical"}],"best_oa_location":null,"sustainable_development_goals":[{"score":1.0,"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy"},{"score":0.8996999859809875,"id":"https://metadata.un.org/sdg/9","display_name":"Industry, innovation and infrastructure"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":16,"referenced_works":["https://openalex.org/W1503694877","https://openalex.org/W1540107832","https://openalex.org/W1970676140","https://openalex.org/W1987953395","https://openalex.org/W1997936011","https://openalex.org/W1998572623","https://openalex.org/W2114153151","https://openalex.org/W2127014719","https://openalex.org/W2142441939","https://openalex.org/W2146531934","https://openalex.org/W2149177425","https://openalex.org/W2158357773","https://openalex.org/W2160935860","https://openalex.org/W2164063344","https://openalex.org/W4256642209","https://openalex.org/W6944911617"],"related_works":["https://openalex.org/W2809853339","https://openalex.org/W1986055266","https://openalex.org/W2487479535","https://openalex.org/W4400774194","https://openalex.org/W4206882226","https://openalex.org/W1508004232","https://openalex.org/W3202271302","https://openalex.org/W2736162064","https://openalex.org/W4386859327","https://openalex.org/W2066093562"],"abstract_inverted_index":{"The":[0,91],"generation":[1,34,125],"of":[2,72,123],"power":[3,64,99,111],"by":[4],"photovoltaic":[5],"(PV)":[6],"systems":[7],"is":[8,126],"constantly":[9],"increasing":[10],"in":[11,16,83],"low-voltage":[12],"(LV)":[13],"distribution":[14],"grids,":[15],"line":[17],"with":[18,25,87,97,120],"the":[19,26,46,63,79,114,134],"European":[20],"environmental":[21],"targets.":[22],"To":[23],"cope":[24],"effects":[27],"on":[28],"grid":[29,86,107,119],"voltage":[30,80],"profiles":[31],"during":[32],"high":[33,88,121],"and":[35,101,109],"low":[36],"demand":[37],"periods,":[38],"new":[39],"solutions":[40,50],"need":[41],"to":[42,54,77,105],"be":[43,103],"established.":[44],"In":[45,67],"long":[47],"term,":[48],"these":[49],"should":[51],"also":[52],"aim":[53],"allow":[55],"further":[56],"more":[57],"PV":[58,89,124],"installed":[59],"capacity,":[60],"while":[61],"meeting":[62],"quality":[65,81],"requirements.":[66],"this":[68],"paper,":[69],"different":[70],"concepts":[71,94],"energy":[73],"storage":[74,93],"are":[75],"proposed":[76,92],"ensure":[78],"requirements":[82],"a":[84,116],"LV":[85,118,135],"penetration.":[90],"can":[95,102],"cooperate":[96],"reactive":[98],"methods":[100],"used":[104],"avoid":[106],"reinforcement":[108],"active":[110],"curtailment.":[112],"For":[113],"study,":[115],"residential":[117],"share":[122],"used.":[127],"Simulation":[128],"results":[129],"show":[130],"substantial":[131],"benefits":[132],"for":[133,144],"feeders":[136],"operation,":[137],"as":[138,140],"well":[139],"an":[141],"increased":[142],"potential":[143],"local":[145],"consumption.":[146]},"counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2025,"cited_by_count":1},{"year":2024,"cited_by_count":3},{"year":2023,"cited_by_count":1},{"year":2022,"cited_by_count":2},{"year":2021,"cited_by_count":5},{"year":2020,"cited_by_count":4},{"year":2019,"cited_by_count":5},{"year":2018,"cited_by_count":7},{"year":2017,"cited_by_count":6},{"year":2016,"cited_by_count":9},{"year":2015,"cited_by_count":6},{"year":2014,"cited_by_count":2},{"year":2013,"cited_by_count":4}],"updated_date":"2026-11-07T11:25:07.637180","created_date":"2016-06-24T00:00:00"}
