{"id":"https://openalex.org/W2017358755","doi":"https://doi.org/10.1109/iedm.2014.7046978","title":"A 55 nm triple gate oxide 9 metal layers SiGe BiCMOS technology featuring 320 GHz fT / 370 GHz fMAX HBT and high-Q millimeter-wave passives","display_name":"A 55 nm triple gate oxide 9 metal layers SiGe BiCMOS technology featuring 320 GHz fT / 370 GHz fMAX HBT and high-Q millimeter-wave passives","publication_year":2014,"publication_date":"2014-12-01","ids":{"openalex":"https://openalex.org/W2017358755","doi":"https://doi.org/10.1109/iedm.2014.7046978","mag":"2017358755"},"language":"en","primary_location":{"id":"doi:10.1109/iedm.2014.7046978","doi":"https://doi.org/10.1109/iedm.2014.7046978","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iedm.2014.7046978","pdf_url":null,"source":{"id":"https://openalex.org/S4210168112","display_name":"Technical digest - International Electron Devices Meeting/Technical digest","issn_l":"0163-1918","issn":["0163-1918","2156-017X"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2014 IEEE International Electron Devices Meeting","raw_type":"proceedings-article"},"volume":null,"type":"conference-paper","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5024136451","display_name":"Pascal Chevalier","orcid":"https://orcid.org/0000-0003-1848-9986","observed_orcids":["https://orcid.org/0000-0003-1848-9986"]},"institutions":[{"id":"https://openalex.org/I4210104693","display_name":"STMicroelectronics (France)","ror":"https://ror.org/01c74sd89","country_code":"FR","type":"company","lineage":["https://openalex.org/I131827901","https://openalex.org/I4210104693"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"P. Chevalier","raw_affiliation_strings":["STMicroelectronics, Crolles, France","850 rue Jean Monnet, Crolles, France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"STMicroelectronics, Crolles, France","institution_ids":["https://openalex.org/I4210104693"]},{"raw_affiliation_string":"850 rue Jean Monnet, Crolles, France","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5009915771","display_name":"G. Avenier","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4210104693","display_name":"STMicroelectronics (France)","ror":"https://ror.org/01c74sd89","country_code":"FR","type":"company","lineage":["https://openalex.org/I131827901","https://openalex.org/I4210104693"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"G. Avenier","raw_affiliation_strings":["STMicroelectronics, Crolles, France","850 rue Jean Monnet, Crolles, France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"STMicroelectronics, Crolles, France","institution_ids":["https://openalex.org/I4210104693"]},{"raw_affiliation_string":"850 rue Jean Monnet, Crolles, France","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5108775755","display_name":"G. Ribes","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4210104693","display_name":"STMicroelectronics (France)","ror":"https://ror.org/01c74sd89","country_code":"FR","type":"company","lineage":["https://openalex.org/I131827901","https://openalex.org/I4210104693"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"G. Ribes","raw_affiliation_strings":["STMicroelectronics, Crolles, France","850 rue Jean Monnet, Crolles, France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"STMicroelectronics, Crolles, France","institution_ids":["https://openalex.org/I4210104693"]},{"raw_affiliation_string":"850 rue Jean Monnet, Crolles, France","institution_ids":[]}]},{"author_position":"middle","author":{"id":null,"display_name":"A. Montagne","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4210104693","display_name":"STMicroelectronics (France)","ror":"https://ror.org/01c74sd89","country_code":"FR","type":"company","lineage":["https://openalex.org/I131827901","https://openalex.org/I4210104693"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"A. Montagne","raw_affiliation_strings":["STMicroelectronics, Crolles, France","850 rue Jean Monnet, Crolles, France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"STMicroelectronics, Crolles, France","institution_ids":["https://openalex.org/I4210104693"]},{"raw_affiliation_string":"850 rue Jean Monnet, Crolles, France","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5091517439","display_name":"E. Canderle","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4210104693","display_name":"STMicroelectronics (France)","ror":"https://ror.org/01c74sd89","country_code":"FR","type":"company","lineage":["https://openalex.org/I131827901","https://openalex.org/I4210104693"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"E. Canderle","raw_affiliation_strings":["STMicroelectronics, Crolles, France","850 rue Jean Monnet, Crolles, France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"STMicroelectronics, Crolles, France","institution_ids":["https://openalex.org/I4210104693"]},{"raw_affiliation_string":"850 rue Jean Monnet, Crolles, France","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5060715134","display_name":"D. C\u00e9li","orcid":"https://orcid.org/0000-0002-6203-2732","observed_orcids":["https://orcid.org/0000-0002-6203-2732"]},"institutions":[{"id":"https://openalex.org/I4210104693","display_name":"STMicroelectronics (France)","ror":"https://ror.org/01c74sd89","country_code":"FR","type":"company","lineage":["https://openalex.org/I131827901","https://openalex.org/I4210104693"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"D. Celi","raw_affiliation_strings":["STMicroelectronics, Crolles, France","850 rue Jean Monnet, Crolles, France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"STMicroelectronics, Crolles, France","institution_ids":["https://openalex.org/I4210104693"]},{"raw_affiliation_string":"850 rue Jean Monnet, Crolles, France","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5089329860","display_name":"N. Derrier","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4210104693","display_name":"STMicroelectronics (France)","ror":"https://ror.org/01c74sd89","country_code":"FR","type":"company","lineage":["https://openalex.org/I131827901","https://openalex.org/I4210104693"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"N. Derrier","raw_affiliation_strings":["STMicroelectronics, Crolles, France","850 rue Jean Monnet, Crolles, France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"STMicroelectronics, Crolles, France","institution_ids":["https://openalex.org/I4210104693"]},{"raw_affiliation_string":"850 rue Jean Monnet, Crolles, France","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5079459963","display_name":"C. Deglise-Favre","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4210104693","display_name":"STMicroelectronics (France)","ror":"https://ror.org/01c74sd89","country_code":"FR","type":"company","lineage":["https://openalex.org/I131827901","https://openalex.org/I4210104693"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"C. Deglise","raw_affiliation_strings":["STMicroelectronics, Crolles, France","850 rue Jean Monnet, Crolles, France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"STMicroelectronics, Crolles, France","institution_ids":["https://openalex.org/I4210104693"]},{"raw_affiliation_string":"850 rue Jean Monnet, Crolles, France","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5081645961","display_name":"C. Durand","orcid":"https://orcid.org/0009-0004-0863-163X","observed_orcids":["https://orcid.org/0009-0004-0863-163X"]},"institutions":[{"id":"https://openalex.org/I4210104693","display_name":"STMicroelectronics (France)","ror":"https://ror.org/01c74sd89","country_code":"FR","type":"company","lineage":["https://openalex.org/I131827901","https://openalex.org/I4210104693"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"C. Durand","raw_affiliation_strings":["STMicroelectronics, Crolles, France","850 rue Jean Monnet, Crolles, France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"STMicroelectronics, Crolles, France","institution_ids":["https://openalex.org/I4210104693"]},{"raw_affiliation_string":"850 rue Jean Monnet, Crolles, France","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5106133481","display_name":"Thomas Qu\u00e9merais","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4210104693","display_name":"STMicroelectronics (France)","ror":"https://ror.org/01c74sd89","country_code":"FR","type":"company","lineage":["https://openalex.org/I131827901","https://openalex.org/I4210104693"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"T. Quemerais","raw_affiliation_strings":["STMicroelectronics, Crolles, France","850 rue Jean Monnet, Crolles, France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"STMicroelectronics, Crolles, France","institution_ids":["https://openalex.org/I4210104693"]},{"raw_affiliation_string":"850 rue Jean Monnet, Crolles, France","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5038001123","display_name":"Michel Buczko","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4210104693","display_name":"STMicroelectronics (France)","ror":"https://ror.org/01c74sd89","country_code":"FR","type":"company","lineage":["https://openalex.org/I131827901","https://openalex.org/I4210104693"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"M. Buczko","raw_affiliation_strings":["STMicroelectronics, Crolles, France","850 rue Jean Monnet, Crolles, France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"STMicroelectronics, Crolles, France","institution_ids":["https://openalex.org/I4210104693"]},{"raw_affiliation_string":"850 rue Jean Monnet, Crolles, France","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5102821697","display_name":"Daniel Gloria","orcid":"https://orcid.org/0000-0003-2763-8453","observed_orcids":["https://orcid.org/0000-0003-2763-8453"]},"institutions":[{"id":"https://openalex.org/I4210104693","display_name":"STMicroelectronics (France)","ror":"https://ror.org/01c74sd89","country_code":"FR","type":"company","lineage":["https://openalex.org/I131827901","https://openalex.org/I4210104693"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"D. Gloria","raw_affiliation_strings":["STMicroelectronics, Crolles, France","850 rue Jean Monnet, Crolles, France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"STMicroelectronics, Crolles, France","institution_ids":["https://openalex.org/I4210104693"]},{"raw_affiliation_string":"850 rue Jean Monnet, Crolles, France","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5018691882","display_name":"O. Robin","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4210104693","display_name":"STMicroelectronics (France)","ror":"https://ror.org/01c74sd89","country_code":"FR","type":"company","lineage":["https://openalex.org/I131827901","https://openalex.org/I4210104693"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"O. Robin","raw_affiliation_strings":["STMicroelectronics, Crolles, France","850 rue Jean Monnet, Crolles, France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"STMicroelectronics, Crolles, France","institution_ids":["https://openalex.org/I4210104693"]},{"raw_affiliation_string":"850 rue Jean Monnet, Crolles, France","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5087379232","display_name":"S. Petitdidier","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4210104693","display_name":"STMicroelectronics (France)","ror":"https://ror.org/01c74sd89","country_code":"FR","type":"company","lineage":["https://openalex.org/I131827901","https://openalex.org/I4210104693"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"S. Petitdidier","raw_affiliation_strings":["STMicroelectronics, Crolles, France","850 rue Jean Monnet, Crolles, France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"STMicroelectronics, Crolles, France","institution_ids":["https://openalex.org/I4210104693"]},{"raw_affiliation_string":"850 rue Jean Monnet, Crolles, France","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5078044121","display_name":"Yves Campidelli","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4210104693","display_name":"STMicroelectronics (France)","ror":"https://ror.org/01c74sd89","country_code":"FR","type":"company","lineage":["https://openalex.org/I131827901","https://openalex.org/I4210104693"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"Y. Campidelli","raw_affiliation_strings":["STMicroelectronics, Crolles, France","850 rue Jean Monnet, Crolles, France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"STMicroelectronics, Crolles, France","institution_ids":["https://openalex.org/I4210104693"]},{"raw_affiliation_string":"850 rue Jean Monnet, Crolles, France","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5002355458","display_name":"Francesco Abbate","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4210104693","display_name":"STMicroelectronics (France)","ror":"https://ror.org/01c74sd89","country_code":"FR","type":"company","lineage":["https://openalex.org/I131827901","https://openalex.org/I4210104693"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"F. Abbate","raw_affiliation_strings":["STMicroelectronics, Crolles, France","850 rue Jean Monnet, Crolles, France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"STMicroelectronics, Crolles, France","institution_ids":["https://openalex.org/I4210104693"]},{"raw_affiliation_string":"850 rue Jean Monnet, Crolles, France","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5049569348","display_name":"Mickael Gros-Jean","orcid":"https://orcid.org/0000-0002-7700-032X","observed_orcids":["https://orcid.org/0000-0002-7700-032X"]},"institutions":[{"id":"https://openalex.org/I4210104693","display_name":"STMicroelectronics (France)","ror":"https://ror.org/01c74sd89","country_code":"FR","type":"company","lineage":["https://openalex.org/I131827901","https://openalex.org/I4210104693"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"M. Gros-Jean","raw_affiliation_strings":["STMicroelectronics, Crolles, France","850 rue Jean Monnet, Crolles, France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"STMicroelectronics, Crolles, France","institution_ids":["https://openalex.org/I4210104693"]},{"raw_affiliation_string":"850 rue Jean Monnet, Crolles, France","institution_ids":[]}]},{"author_position":"middle","author":{"id":null,"display_name":"L. Berthier","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4210104693","display_name":"STMicroelectronics (France)","ror":"https://ror.org/01c74sd89","country_code":"FR","type":"company","lineage":["https://openalex.org/I131827901","https://openalex.org/I4210104693"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"L. Berthier","raw_affiliation_strings":["STMicroelectronics, Crolles, France","850 rue Jean Monnet, Crolles, France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"STMicroelectronics, Crolles, France","institution_ids":["https://openalex.org/I4210104693"]},{"raw_affiliation_string":"850 rue Jean Monnet, Crolles, France","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5111125593","display_name":"J.D. Chapon","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4210104693","display_name":"STMicroelectronics (France)","ror":"https://ror.org/01c74sd89","country_code":"FR","type":"company","lineage":["https://openalex.org/I131827901","https://openalex.org/I4210104693"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"J.D. Chapon","raw_affiliation_strings":["STMicroelectronics, Crolles, France","850 rue Jean Monnet, Crolles, France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"STMicroelectronics, Crolles, France","institution_ids":["https://openalex.org/I4210104693"]},{"raw_affiliation_string":"850 rue Jean Monnet, Crolles, France","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5082280301","display_name":"Francois Leverd","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4210104693","display_name":"STMicroelectronics (France)","ror":"https://ror.org/01c74sd89","country_code":"FR","type":"company","lineage":["https://openalex.org/I131827901","https://openalex.org/I4210104693"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"F. Leverd","raw_affiliation_strings":["STMicroelectronics, Crolles, France","850 rue Jean Monnet, Crolles, France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"STMicroelectronics, Crolles, France","institution_ids":["https://openalex.org/I4210104693"]},{"raw_affiliation_string":"850 rue Jean Monnet, Crolles, France","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5052873899","display_name":"C. Jenny","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4210104693","display_name":"STMicroelectronics (France)","ror":"https://ror.org/01c74sd89","country_code":"FR","type":"company","lineage":["https://openalex.org/I131827901","https://openalex.org/I4210104693"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"C. Jenny","raw_affiliation_strings":["STMicroelectronics, Crolles, France","850 rue Jean Monnet, Crolles, France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"STMicroelectronics, Crolles, France","institution_ids":["https://openalex.org/I4210104693"]},{"raw_affiliation_string":"850 rue Jean Monnet, Crolles, France","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5019522289","display_name":"Claire Therese Richard","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4210104693","display_name":"STMicroelectronics (France)","ror":"https://ror.org/01c74sd89","country_code":"FR","type":"company","lineage":["https://openalex.org/I131827901","https://openalex.org/I4210104693"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"C. Richard","raw_affiliation_strings":["STMicroelectronics, Crolles, France","850 rue Jean Monnet, Crolles, France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"STMicroelectronics, Crolles, France","institution_ids":["https://openalex.org/I4210104693"]},{"raw_affiliation_string":"850 rue Jean Monnet, Crolles, France","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5041355336","display_name":"Olivier Gourhant","orcid":"https://orcid.org/0000-0002-5087-5484","observed_orcids":["https://orcid.org/0000-0002-5087-5484"]},"institutions":[{"id":"https://openalex.org/I4210104693","display_name":"STMicroelectronics (France)","ror":"https://ror.org/01c74sd89","country_code":"FR","type":"company","lineage":["https://openalex.org/I131827901","https://openalex.org/I4210104693"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"O. Gourhant","raw_affiliation_strings":["STMicroelectronics, Crolles, France","850 rue Jean Monnet, Crolles, France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"STMicroelectronics, Crolles, France","institution_ids":["https://openalex.org/I4210104693"]},{"raw_affiliation_string":"850 rue Jean Monnet, Crolles, France","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5017742129","display_name":"Come de Buttet","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I2738703131","display_name":"Commissariat \u00e0 l'\u00c9nergie Atomique et aux \u00c9nergies Alternatives","ror":"https://ror.org/00jjx8s55","country_code":"FR","type":"government","lineage":["https://openalex.org/I2738703131"]},{"id":"https://openalex.org/I4210104693","display_name":"STMicroelectronics (France)","ror":"https://ror.org/01c74sd89","country_code":"FR","type":"company","lineage":["https://openalex.org/I131827901","https://openalex.org/I4210104693"]},{"id":"https://openalex.org/I4210150049","display_name":"Laboratoire d'\u00c9lectronique des Technologies de l'Information","ror":"https://ror.org/04mf0wv34","country_code":"FR","type":"government","lineage":["https://openalex.org/I2738703131","https://openalex.org/I4210117989","https://openalex.org/I4210150049"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"C. De-Buttet","raw_affiliation_strings":["CEA-LETI, Crolles, France","STMicroelectronics & CEA-LETI, France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"CEA-LETI, Crolles, France","institution_ids":["https://openalex.org/I2738703131","https://openalex.org/I4210150049"]},{"raw_affiliation_string":"STMicroelectronics & CEA-LETI, France","institution_ids":["https://openalex.org/I2738703131","https://openalex.org/I4210104693","https://openalex.org/I4210150049"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5112462942","display_name":"R\u00e9mi Beneyton","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4210104693","display_name":"STMicroelectronics (France)","ror":"https://ror.org/01c74sd89","country_code":"FR","type":"company","lineage":["https://openalex.org/I131827901","https://openalex.org/I4210104693"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"R. Beneyton","raw_affiliation_strings":["STMicroelectronics, Crolles, France","850 rue Jean Monnet, Crolles, France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"STMicroelectronics, Crolles, France","institution_ids":["https://openalex.org/I4210104693"]},{"raw_affiliation_string":"850 rue Jean Monnet, Crolles, France","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5062286277","display_name":"Patrick Maury","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4210104693","display_name":"STMicroelectronics (France)","ror":"https://ror.org/01c74sd89","country_code":"FR","type":"company","lineage":["https://openalex.org/I131827901","https://openalex.org/I4210104693"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"P. Maury","raw_affiliation_strings":["STMicroelectronics, Crolles, France","850 rue Jean Monnet, Crolles, France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"STMicroelectronics, Crolles, France","institution_ids":["https://openalex.org/I4210104693"]},{"raw_affiliation_string":"850 rue Jean Monnet, Crolles, France","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5111020074","display_name":"S. Joblot","orcid":"https://orcid.org/0009-0001-5137-7137","observed_orcids":["https://orcid.org/0009-0001-5137-7137"]},"institutions":[{"id":"https://openalex.org/I4210104693","display_name":"STMicroelectronics (France)","ror":"https://ror.org/01c74sd89","country_code":"FR","type":"company","lineage":["https://openalex.org/I131827901","https://openalex.org/I4210104693"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"S. Joblot","raw_affiliation_strings":["STMicroelectronics, Crolles, France","850 rue Jean Monnet, Crolles, France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"STMicroelectronics, Crolles, France","institution_ids":["https://openalex.org/I4210104693"]},{"raw_affiliation_string":"850 rue Jean Monnet, Crolles, France","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5050189202","display_name":"Laurent Favennec","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4210104693","display_name":"STMicroelectronics (France)","ror":"https://ror.org/01c74sd89","country_code":"FR","type":"company","lineage":["https://openalex.org/I131827901","https://openalex.org/I4210104693"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"L. Favennec","raw_affiliation_strings":["STMicroelectronics, Crolles, France","850 rue Jean Monnet, Crolles, France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"STMicroelectronics, Crolles, France","institution_ids":["https://openalex.org/I4210104693"]},{"raw_affiliation_string":"850 rue Jean Monnet, Crolles, France","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5002534389","display_name":"Marc Guillermet","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I2738703131","display_name":"Commissariat \u00e0 l'\u00c9nergie Atomique et aux \u00c9nergies Alternatives","ror":"https://ror.org/00jjx8s55","country_code":"FR","type":"government","lineage":["https://openalex.org/I2738703131"]},{"id":"https://openalex.org/I4210104693","display_name":"STMicroelectronics (France)","ror":"https://ror.org/01c74sd89","country_code":"FR","type":"company","lineage":["https://openalex.org/I131827901","https://openalex.org/I4210104693"]},{"id":"https://openalex.org/I4210150049","display_name":"Laboratoire d'\u00c9lectronique des Technologies de l'Information","ror":"https://ror.org/04mf0wv34","country_code":"FR","type":"government","lineage":["https://openalex.org/I2738703131","https://openalex.org/I4210117989","https://openalex.org/I4210150049"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"M. Guillermet","raw_affiliation_strings":["CEA-LETI, Crolles, France","STMicroelectronics & CEA-LETI, France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"CEA-LETI, Crolles, France","institution_ids":["https://openalex.org/I2738703131","https://openalex.org/I4210150049"]},{"raw_affiliation_string":"STMicroelectronics & CEA-LETI, France","institution_ids":["https://openalex.org/I2738703131","https://openalex.org/I4210104693","https://openalex.org/I4210150049"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5053304149","display_name":"Ph. Brun","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I2738703131","display_name":"Commissariat \u00e0 l'\u00c9nergie Atomique et aux \u00c9nergies Alternatives","ror":"https://ror.org/00jjx8s55","country_code":"FR","type":"government","lineage":["https://openalex.org/I2738703131"]},{"id":"https://openalex.org/I4210104693","display_name":"STMicroelectronics (France)","ror":"https://ror.org/01c74sd89","country_code":"FR","type":"company","lineage":["https://openalex.org/I131827901","https://openalex.org/I4210104693"]},{"id":"https://openalex.org/I4210150049","display_name":"Laboratoire d'\u00c9lectronique des Technologies de l'Information","ror":"https://ror.org/04mf0wv34","country_code":"FR","type":"government","lineage":["https://openalex.org/I2738703131","https://openalex.org/I4210117989","https://openalex.org/I4210150049"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"P. Brun","raw_affiliation_strings":["CEA-LETI, Crolles, France","STMicroelectronics & CEA-LETI, France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"CEA-LETI, Crolles, France","institution_ids":["https://openalex.org/I2738703131","https://openalex.org/I4210150049"]},{"raw_affiliation_string":"STMicroelectronics & CEA-LETI, France","institution_ids":["https://openalex.org/I2738703131","https://openalex.org/I4210104693","https://openalex.org/I4210150049"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5108431100","display_name":"Kristell Courouble","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4210104693","display_name":"STMicroelectronics (France)","ror":"https://ror.org/01c74sd89","country_code":"FR","type":"company","lineage":["https://openalex.org/I131827901","https://openalex.org/I4210104693"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"K. Courouble","raw_affiliation_strings":["STMicroelectronics, Crolles, France","850 rue Jean Monnet, Crolles, France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"STMicroelectronics, Crolles, France","institution_ids":["https://openalex.org/I4210104693"]},{"raw_affiliation_string":"850 rue Jean Monnet, Crolles, France","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5059757614","display_name":"Katia Haxaire","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4210104693","display_name":"STMicroelectronics (France)","ror":"https://ror.org/01c74sd89","country_code":"FR","type":"company","lineage":["https://openalex.org/I131827901","https://openalex.org/I4210104693"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"K. Haxaire","raw_affiliation_strings":["STMicroelectronics, Crolles, France","850 rue Jean Monnet, Crolles, France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"STMicroelectronics, Crolles, France","institution_ids":["https://openalex.org/I4210104693"]},{"raw_affiliation_string":"850 rue Jean Monnet, Crolles, France","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5022519081","display_name":"Guy Imbert","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4210104693","display_name":"STMicroelectronics (France)","ror":"https://ror.org/01c74sd89","country_code":"FR","type":"company","lineage":["https://openalex.org/I131827901","https://openalex.org/I4210104693"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"G. Imbert","raw_affiliation_strings":["STMicroelectronics, Crolles, France","850 rue Jean Monnet, Crolles, France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"STMicroelectronics, Crolles, France","institution_ids":["https://openalex.org/I4210104693"]},{"raw_affiliation_string":"850 rue Jean Monnet, Crolles, France","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5087172240","display_name":"Emmanuel Gourvest","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4210104693","display_name":"STMicroelectronics (France)","ror":"https://ror.org/01c74sd89","country_code":"FR","type":"company","lineage":["https://openalex.org/I131827901","https://openalex.org/I4210104693"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"E. Gourvest","raw_affiliation_strings":["STMicroelectronics, Crolles, France","850 rue Jean Monnet, Crolles, France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"STMicroelectronics, Crolles, France","institution_ids":["https://openalex.org/I4210104693"]},{"raw_affiliation_string":"850 rue Jean Monnet, Crolles, France","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5019686018","display_name":"J. Cossalter","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4210104693","display_name":"STMicroelectronics (France)","ror":"https://ror.org/01c74sd89","country_code":"FR","type":"company","lineage":["https://openalex.org/I131827901","https://openalex.org/I4210104693"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"J. Cossalter","raw_affiliation_strings":["STMicroelectronics, Crolles, France","850 rue Jean Monnet, Crolles, France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"STMicroelectronics, Crolles, France","institution_ids":["https://openalex.org/I4210104693"]},{"raw_affiliation_string":"850 rue Jean Monnet, Crolles, France","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5030820036","display_name":"O. Saxod","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4210104693","display_name":"STMicroelectronics (France)","ror":"https://ror.org/01c74sd89","country_code":"FR","type":"company","lineage":["https://openalex.org/I131827901","https://openalex.org/I4210104693"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"O. Saxod","raw_affiliation_strings":["STMicroelectronics, Crolles, France","850 rue Jean Monnet, Crolles, France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"STMicroelectronics, Crolles, France","institution_ids":["https://openalex.org/I4210104693"]},{"raw_affiliation_string":"850 rue Jean Monnet, Crolles, France","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5048142507","display_name":"C. Tavernier","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4210104693","display_name":"STMicroelectronics (France)","ror":"https://ror.org/01c74sd89","country_code":"FR","type":"company","lineage":["https://openalex.org/I131827901","https://openalex.org/I4210104693"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"C. Tavernier","raw_affiliation_strings":["STMicroelectronics, Crolles, France","850 rue Jean Monnet, Crolles, France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"STMicroelectronics, Crolles, France","institution_ids":["https://openalex.org/I4210104693"]},{"raw_affiliation_string":"850 rue Jean Monnet, Crolles, France","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5110015010","display_name":"Franck Foussadier","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4210104693","display_name":"STMicroelectronics (France)","ror":"https://ror.org/01c74sd89","country_code":"FR","type":"company","lineage":["https://openalex.org/I131827901","https://openalex.org/I4210104693"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"F. Foussadier","raw_affiliation_strings":["STMicroelectronics, Crolles, France","850 rue Jean Monnet, Crolles, France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"STMicroelectronics, Crolles, France","institution_ids":["https://openalex.org/I4210104693"]},{"raw_affiliation_string":"850 rue Jean Monnet, Crolles, France","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5089860652","display_name":"B. Ramadout","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4210104693","display_name":"STMicroelectronics (France)","ror":"https://ror.org/01c74sd89","country_code":"FR","type":"company","lineage":["https://openalex.org/I131827901","https://openalex.org/I4210104693"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"B. Ramadout","raw_affiliation_strings":["STMicroelectronics, Crolles, France","850 rue Jean Monnet, Crolles, France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"STMicroelectronics, Crolles, France","institution_ids":["https://openalex.org/I4210104693"]},{"raw_affiliation_string":"850 rue Jean Monnet, Crolles, France","institution_ids":[]}]},{"author_position":"middle","author":{"id":null,"display_name":"R. Bianchini","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4210104693","display_name":"STMicroelectronics (France)","ror":"https://ror.org/01c74sd89","country_code":"FR","type":"company","lineage":["https://openalex.org/I131827901","https://openalex.org/I4210104693"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"R. Bianchini","raw_affiliation_strings":["STMicroelectronics, Crolles, France","850 rue Jean Monnet, Crolles, France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"STMicroelectronics, Crolles, France","institution_ids":["https://openalex.org/I4210104693"]},{"raw_affiliation_string":"850 rue Jean Monnet, Crolles, France","institution_ids":[]}]},{"author_position":"middle","author":{"id":null,"display_name":"C. Julien","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4210104693","display_name":"STMicroelectronics (France)","ror":"https://ror.org/01c74sd89","country_code":"FR","type":"company","lineage":["https://openalex.org/I131827901","https://openalex.org/I4210104693"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"C. Julien","raw_affiliation_strings":["STMicroelectronics, Crolles, France","850 rue Jean Monnet, Crolles, France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"STMicroelectronics, Crolles, France","institution_ids":["https://openalex.org/I4210104693"]},{"raw_affiliation_string":"850 rue Jean Monnet, Crolles, France","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5030226306","display_name":"David Ney","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4210104693","display_name":"STMicroelectronics (France)","ror":"https://ror.org/01c74sd89","country_code":"FR","type":"company","lineage":["https://openalex.org/I131827901","https://openalex.org/I4210104693"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"D. Ney","raw_affiliation_strings":["STMicroelectronics, Crolles, France","850 rue Jean Monnet, Crolles, France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"STMicroelectronics, Crolles, France","institution_ids":["https://openalex.org/I4210104693"]},{"raw_affiliation_string":"850 rue Jean Monnet, Crolles, France","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5042960119","display_name":"Jos\u00e9 M. de la Rosa","orcid":"https://orcid.org/0000-0003-2848-9226","observed_orcids":["https://orcid.org/0000-0003-2848-9226"]},"institutions":[{"id":"https://openalex.org/I4210104693","display_name":"STMicroelectronics (France)","ror":"https://ror.org/01c74sd89","country_code":"FR","type":"company","lineage":["https://openalex.org/I131827901","https://openalex.org/I4210104693"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"J. Rosa","raw_affiliation_strings":["STMicroelectronics, Crolles, France","850 rue Jean Monnet, Crolles, France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"STMicroelectronics, Crolles, France","institution_ids":["https://openalex.org/I4210104693"]},{"raw_affiliation_string":"850 rue Jean Monnet, Crolles, France","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5051158092","display_name":"S. Haendler","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4210104693","display_name":"STMicroelectronics (France)","ror":"https://ror.org/01c74sd89","country_code":"FR","type":"company","lineage":["https://openalex.org/I131827901","https://openalex.org/I4210104693"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"S. Haendler","raw_affiliation_strings":["STMicroelectronics, Crolles, France","850 rue Jean Monnet, Crolles, France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"STMicroelectronics, Crolles, France","institution_ids":["https://openalex.org/I4210104693"]},{"raw_affiliation_string":"850 rue Jean Monnet, Crolles, France","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5037418141","display_name":"Y. Carminati","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4210104693","display_name":"STMicroelectronics (France)","ror":"https://ror.org/01c74sd89","country_code":"FR","type":"company","lineage":["https://openalex.org/I131827901","https://openalex.org/I4210104693"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"Y. Carminati","raw_affiliation_strings":["STMicroelectronics, Crolles, France","850 rue Jean Monnet, Crolles, France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"STMicroelectronics, Crolles, France","institution_ids":["https://openalex.org/I4210104693"]},{"raw_affiliation_string":"850 rue Jean Monnet, Crolles, France","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5083619989","display_name":"Bertrand Borot","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4210104693","display_name":"STMicroelectronics (France)","ror":"https://ror.org/01c74sd89","country_code":"FR","type":"company","lineage":["https://openalex.org/I131827901","https://openalex.org/I4210104693"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"B. Borot","raw_affiliation_strings":["STMicroelectronics, Crolles, France","850 rue Jean Monnet, Crolles, France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"STMicroelectronics, Crolles, France","institution_ids":["https://openalex.org/I4210104693"]},{"raw_affiliation_string":"850 rue Jean Monnet, Crolles, France","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":21.6782,"has_fulltext":false,"cited_by_count":200,"citation_normalized_percentile":{"value":0.99834772,"is_in_top_1_percent":true,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":88,"max":100},"biblio":{"volume":null,"issue":null,"first_page":"3.9.1","last_page":"3.9.3"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10187","display_name":"Radio Frequency Integrated Circuit Design","score":0.8217999935150146,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10187","display_name":"Radio Frequency Integrated Circuit Design","score":0.8217999935150146,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10558","display_name":"Advancements in Semiconductor Devices and Circuit Design","score":0.16830000281333923,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10472","display_name":"Semiconductor materials and devices","score":0.0026000000070780516,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/sige-bicmos","display_name":"SiGe BiCMOS","score":0.9409999847412109},{"id":"https://openalex.org/keywords/high-electron-mobility-transistors","display_name":"high electron mobility transistors","score":0.8040000200271606},{"id":"https://openalex.org/keywords/high-q-inductors","display_name":"high-Q inductors","score":0.8379999995231628},{"id":"https://openalex.org/keywords/transmission-lines","display_name":"transmission lines","score":0.652999997138977},{"id":"https://openalex.org/keywords/sram-cell","display_name":"SRAM cell","score":0.7179999947547913},{"id":"https://openalex.org/keywords/gate-delay","display_name":"gate delay","score":0.6840000152587891},{"id":"https://openalex.org/keywords/high-speed-transistors","display_name":"high-speed transistors","score":0.4659999907016754}],"concepts":[{"id":"https://openalex.org/C62427370","wikidata":"https://www.wikidata.org/wiki/Q173416","display_name":"BiCMOS","level":4,"score":0.6093614101409912},{"id":"https://openalex.org/C46362747","wikidata":"https://www.wikidata.org/wiki/Q173431","display_name":"CMOS","level":2,"score":0.6038619875907898},{"id":"https://openalex.org/C52192207","wikidata":"https://www.wikidata.org/wiki/Q5322","display_name":"Capacitor","level":3,"score":0.49601778388023376},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.4919454753398895},{"id":"https://openalex.org/C49040817","wikidata":"https://www.wikidata.org/wiki/Q193091","display_name":"Optoelectronics","level":1,"score":0.40706866979599},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.39837056398391724},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.35561251640319824},{"id":"https://openalex.org/C172385210","wikidata":"https://www.wikidata.org/wiki/Q5339","display_name":"Transistor","level":3,"score":0.22450807690620422},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.20805272459983826},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/iedm.2014.7046978","doi":"https://doi.org/10.1109/iedm.2014.7046978","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iedm.2014.7046978","pdf_url":null,"source":{"id":"https://openalex.org/S4210168112","display_name":"Technical digest - International Electron Devices Meeting/Technical digest","issn_l":"0163-1918","issn":["0163-1918","2156-017X"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2014 IEEE International Electron Devices Meeting","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/9","display_name":"Industry, innovation and infrastructure","score":0.6773999929428101}],"study_designs":[],"awards":[],"funders":[{"id":"https://openalex.org/F4320338388","display_name":"Eurostars","ror":null}],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":1,"referenced_works":["https://openalex.org/W2057815485"],"related_works":["https://openalex.org/W2008349901","https://openalex.org/W2052617132","https://openalex.org/W2015191860","https://openalex.org/W7126206807","https://openalex.org/W2555993941","https://openalex.org/W2101042411","https://openalex.org/W2030892923","https://openalex.org/W1989322668","https://openalex.org/W2057815485","https://openalex.org/W2134529431"],"abstract_inverted_index":{"This":[0],"paper":[1],"presents":[2],"the":[3],"first":[4],"55":[5],"nm":[6],"SiGe":[7],"BiCMOS":[8],"technology":[9,20],"developed":[10],"on":[11],"a":[12,48],"300":[13],"mm":[14],"wafer":[15],"line":[16],"in":[17],"STMicroelectronics.":[18],"The":[19],"features":[21],"Low":[22],"Power":[23],"(LP)":[24],"and":[25,31,62],"General":[26],"Purpose":[27],"(GP)":[28],"CMOS":[29],"devices":[30],"0.45":[32],"\u03bcm26T-SRAM":[33],"bit":[34],"cell.":[35],"High":[36],"Speed":[37],"(HS)":[38],"HBT":[39],"exhibits":[40],"320":[41],"GHz":[42,45],"fTand":[43],"370":[44],"fMAXassociated":[46],"with":[47],"CML":[49],"ring":[50],"oscillator":[51],"gate":[52],"delay":[53],"\u03c4Dof":[54],"2.34":[55],"ps.":[56],"Transmission":[57],"lines,":[58],"capacitors,":[59],"high-Q":[60],"varactors":[61],"inductors":[63],"dedicated":[64],"to":[65],"millimeter-wave":[66],"applications":[67],"are":[68],"also":[69],"available.":[70]},"counts_by_year":[{"year":2026,"cited_by_count":4},{"year":2025,"cited_by_count":7},{"year":2024,"cited_by_count":17},{"year":2023,"cited_by_count":12},{"year":2022,"cited_by_count":16},{"year":2021,"cited_by_count":22},{"year":2020,"cited_by_count":23},{"year":2019,"cited_by_count":22},{"year":2018,"cited_by_count":23},{"year":2017,"cited_by_count":20},{"year":2016,"cited_by_count":17},{"year":2015,"cited_by_count":16},{"year":2014,"cited_by_count":1}],"updated_date":"2026-11-07T11:25:07.637180","created_date":"2016-06-24T00:00:00"}
