{"id":"https://openalex.org/W2017015357","doi":"https://doi.org/10.1049/iet-epa:20080030","title":"Model reference adaptive control-based adaptive current control scheme of a PM synchronous motor with an improved servo performance","display_name":"Model reference adaptive control-based adaptive current control scheme of a PM synchronous motor with an improved servo performance","alternate_titles":[],"publication_year":2009,"publication_date":"2009-01-01","ids":{"openalex":"https://openalex.org/W2017015357","doi":"https://doi.org/10.1049/iet-epa:20080030","mag":"2017015357"},"language":"en","primary_location":{"id":"doi:10.1049/iet-epa:20080030","doi":"https://doi.org/10.1049/iet-epa:20080030","is_oa":false,"landing_page_url":"https://doi.org/10.1049/iet-epa:20080030","pdf_url":null,"source":{"id":"https://openalex.org/S3026325","display_name":"IET Electric Power Applications","issn_l":"1751-8660","issn":["1751-8660","1751-8679"],"is_oa":false,"is_in_doaj":true,"is_core":true,"listed_in":["cwts-core","doaj","dongbi-d","jufo-1","norway-1","oarl","poland-100","russia-white-list-2","vabb-shw"],"host_organization":"https://openalex.org/P4310311714","host_organization_name":"Institution of Engineering and Technology","host_organization_lineage":["https://openalex.org/P4310311714"],"host_organization_lineage_names":["Institution of Engineering and Technology"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IET Electric Power Applications","raw_type":"journal-article"},"parent_works":[],"lineage":["https://openalex.org/W2017015357"],"child_works_count":0,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5034084553","display_name":"Kyeong\u2010Hwa Kim","orcid":"https://orcid.org/0000-0001-5251-6322","observed_orcids":["https://orcid.org/0000-0001-5251-6322"]},"institutions":[{"id":"https://openalex.org/I118373667","display_name":"Seoul National University of Science and Technology","ror":"https://ror.org/00chfja07","country_code":"KR","type":"education","lineage":["https://openalex.org/I118373667"]}],"countries":["KR"],"is_corresponding":true,"contributor_roles":[],"raw_author_name":"K.-H. Kim","raw_affiliation_strings":["Department of Electrical Engineering, Seoul National University of Technology, 172, Gongreung 2-Dong, Nowon-Gu, Seoul, 139-743, South Korea"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, Seoul National University of Technology, 172, Gongreung 2-Dong, Nowon-Gu, Seoul, 139-743, South Korea","institution_ids":["https://openalex.org/I118373667"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":["https://openalex.org/A5034084553"],"corresponding_institution_ids":["https://openalex.org/I118373667"],"apc_list":{"value":2880,"currency":"USD","value_usd":2880},"apc_paid":null,"fwci":4.2086,"has_fulltext":false,"cited_by_count":53,"citation_normalized_percentile":{"value":0.93760532,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":89,"max":98},"biblio":{"volume":"3","issue":"1","first_page":"8","last_page":"18"},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10504","display_name":"Sensorless Control of Electric Motors","score":0.9735999703407288,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10504","display_name":"Sensorless Control of Electric Motors","score":0.9735999703407288,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10228","display_name":"Multilevel Inverters and Converters","score":0.006300000008195639,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10278","display_name":"Electric Motor Design and Analysis","score":0.004399999976158142,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/model-reference-adaptive-control","display_name":"model reference adaptive control","score":0.9990000128746033},{"id":"https://openalex.org/keywords/permanent-magnet-synchronous-motor","display_name":"permanent magnet synchronous motor","score":0.9079999923706055},{"id":"https://openalex.org/keywords/current-control","display_name":"current control","score":0.9300000071525574},{"id":"https://openalex.org/keywords/servo-performance","display_name":"servo performance","score":0.7919999957084656},{"id":"https://openalex.org/keywords/parameter-variation-compensation","display_name":"parameter variation compensation","score":0.6119999885559082},{"id":"https://openalex.org/keywords/disturbance-estimation","display_name":"disturbance estimation","score":0.8349999785423279},{"id":"https://openalex.org/keywords/feedforward-compensation","display_name":"feedforward compensation","score":0.9150000214576721},{"id":"https://openalex.org/keywords/phase-voltage","display_name":"phase voltage","score":0.4580000042915344},{"id":"https://openalex.org/keywords/lyapunov-stability","display_name":"Lyapunov stability","score":0.8460000157356262},{"id":"https://openalex.org/keywords/asymptotic-stability","display_name":"asymptotic stability","score":0.8230000138282776},{"id":"https://openalex.org/keywords/pwm-inverter","display_name":"PWM inverter","score":0.6679999828338623},{"id":"https://openalex.org/keywords/steady-state-response","display_name":"steady-state response","score":0.4950000047683716}],"concepts":[{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.9014382362365723},{"id":"https://openalex.org/C38858127","wikidata":"https://www.wikidata.org/wiki/Q5441228","display_name":"Feed forward","level":2,"score":0.6452952027320862},{"id":"https://openalex.org/C107464732","wikidata":"https://www.wikidata.org/wiki/Q235781","display_name":"Adaptive control","level":3,"score":0.5579706430435181},{"id":"https://openalex.org/C71376005","wikidata":"https://www.wikidata.org/wiki/Q845675","display_name":"Synchronous motor","level":2,"score":0.4806146025657654},{"id":"https://openalex.org/C2776829284","wikidata":"https://www.wikidata.org/wiki/Q1341651","display_name":"Lyapunov stability","level":3,"score":0.4366544187068939},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.42263123393058777},{"id":"https://openalex.org/C8171440","wikidata":"https://www.wikidata.org/wiki/Q903414","display_name":"Steady state (chemistry)","level":2,"score":0.4156317710876465},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.4126163721084595},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.3436707854270935},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.15670102834701538},{"id":"https://openalex.org/C185592680","wikidata":"https://www.wikidata.org/wiki/Q2329","display_name":"Chemistry","level":0,"score":0.0},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.0},{"id":"https://openalex.org/C147789679","wikidata":"https://www.wikidata.org/wiki/Q11372","display_name":"Physical chemistry","level":1,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1049/iet-epa:20080030","doi":"https://doi.org/10.1049/iet-epa:20080030","is_oa":false,"landing_page_url":"https://doi.org/10.1049/iet-epa:20080030","pdf_url":null,"source":{"id":"https://openalex.org/S3026325","display_name":"IET Electric Power Applications","issn_l":"1751-8660","issn":["1751-8660","1751-8679"],"is_oa":false,"is_in_doaj":true,"is_core":true,"listed_in":["cwts-core","doaj","dongbi-d","jufo-1","norway-1","oarl","poland-100","russia-white-list-2","vabb-shw"],"host_organization":"https://openalex.org/P4310311714","host_organization_name":"Institution of Engineering and Technology","host_organization_lineage":["https://openalex.org/P4310311714"],"host_organization_lineage_names":["Institution of Engineering and Technology"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IET Electric Power Applications","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":17,"referenced_works":["https://openalex.org/W1481834144","https://openalex.org/W1487127700","https://openalex.org/W1500685872","https://openalex.org/W1964287508","https://openalex.org/W2048036929","https://openalex.org/W2070847637","https://openalex.org/W2080057141","https://openalex.org/W2096784389","https://openalex.org/W2122269584","https://openalex.org/W2125249568","https://openalex.org/W2125559153","https://openalex.org/W2143763859","https://openalex.org/W2148104278","https://openalex.org/W2154663152","https://openalex.org/W4250418432","https://openalex.org/W6628705127","https://openalex.org/W6681888799"],"related_works":["https://openalex.org/W805994356","https://openalex.org/W3215302661","https://openalex.org/W2135179989","https://openalex.org/W2269418276","https://openalex.org/W2077109802","https://openalex.org/W2115429265","https://openalex.org/W2132355185","https://openalex.org/W1946970665","https://openalex.org/W3198407532"],"abstract_inverted_index":{"A":[0],"model":[1],"reference":[2],"adaptive":[3],"control":[4,7,25,40,86,100],"(MRAC)-based":[5],"current":[6,24,39],"scheme":[8,101,116,158],"of":[9,107,139],"a":[10,43,61,80],"PM":[11,44],"synchronous":[12,45],"motor":[13,55],"with":[14],"an":[15,74,122],"improved":[16],"servo":[17],"performance":[18,87],"is":[19,26,143,159,167],"presented.":[20],"Although":[21],"the":[22,54,63,67,84,105,108,112,126,140,146,152,165,170],"predictive":[23],"known":[27],"to":[28],"give":[29],"ideal":[30],"transient":[31],"and":[32,77,145,164,173],"steady-state":[33,48,85],"responses":[34],"among":[35],"various":[36],"PWM":[37],"inverter-fed":[38],"schemes":[41],"for":[42],"motor,":[46],"its":[47,94],"response":[49],"may":[50],"be":[51,71,89,121],"degraded":[52],"under":[53],"parameter":[56,68],"variations.":[57],"To":[58],"overcome":[59],"such":[60],"limitation,":[62],"disturbances":[64],"caused":[65],"by":[66,79,151],"variations":[69],"will":[70],"estimated":[72],"using":[73,117,161],"MRAC":[75],"technique":[76],"compensated":[78],"feedforward":[81],"manner.":[82],"Thus,":[83],"can":[88,120],"effectively":[90],"improved,":[91],"while":[92],"retaining":[93],"good":[95],"dynamic":[96],"performance.":[97],"The":[98,136,156],"proposed":[99,157],"does":[102],"not":[103],"require":[104],"measurement":[106],"phase":[109,127],"voltage":[110,128],"unlike":[111],"conventional":[113],"disturbance":[114],"estimation":[115],"observer.":[118],"This":[119],"effective":[123],"way":[124],"considering":[125],"contains":[129],"much":[130],"harmonics":[131],"as":[132,134],"well":[133],"noise.":[135],"asymptotic":[137],"stability":[138,154],"overall":[141],"system":[142],"proved":[144],"adaptation":[147],"laws":[148],"are":[149],"derived":[150],"Lyapunov":[153],"theory.":[155],"implemented":[160],"DSP":[162],"TMS320C31":[163],"effectiveness":[166],"verified":[168],"through":[169],"comparative":[171],"simulations":[172],"experiments.":[174]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W2017015357","counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2022,"cited_by_count":4},{"year":2021,"cited_by_count":3},{"year":2020,"cited_by_count":4},{"year":2019,"cited_by_count":2},{"year":2018,"cited_by_count":3},{"year":2017,"cited_by_count":6},{"year":2016,"cited_by_count":4},{"year":2015,"cited_by_count":2},{"year":2014,"cited_by_count":2},{"year":2013,"cited_by_count":4},{"year":2012,"cited_by_count":7}],"updated_date":"2026-11-17T12:49:18.490984","created_date":"2016-06-24T00:00:00"}
