{"id":"https://openalex.org/W2016734896","doi":"https://doi.org/10.1177/1420326x03012003001","title":"Development and Application of a Protocol for the Assessment of Indoor Air Quality","display_name":"Development and Application of a Protocol for the Assessment of Indoor Air Quality","publication_year":2003,"publication_date":"2003-06-01","ids":{"openalex":"https://openalex.org/W2016734896","doi":"https://doi.org/10.1177/1420326x03012003001","mag":"2016734896"},"language":"en","primary_location":{"id":"doi:10.1177/1420326x03012003001","doi":"https://doi.org/10.1177/1420326x03012003001","is_oa":true,"landing_page_url":"https://doi.org/10.1177/1420326x03012003001","pdf_url":"https://journals.sagepub.com/doi/pdf/10.1177/1420326X03012003001?download=true","source":{"id":"https://openalex.org/S163818028","display_name":"Indoor and Built Environment","issn_l":"1420-326X","issn":["1420-326X","1423-0070"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["anvur-scientific","cwts-core","dongbi-c","jufo-1","ki-jl-1","norway-1","poland-70","russia-white-list-1","vabb-shw"],"host_organization":"https://openalex.org/P4310320017","host_organization_name":"SAGE Publishing","host_organization_lineage":["https://openalex.org/P4310320017"],"host_organization_lineage_names":["SAGE Publishing"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Indoor and Built Environment","raw_type":"journal-article"},"volume":null,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"bronze","oa_url":"https://journals.sagepub.com/doi/pdf/10.1177/1420326X03012003001?download=true","any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5032357749","display_name":"G. M\u00f6hle","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I2800994460","display_name":"Building Research Establishment","ror":"https://ror.org/02fmkev06","country_code":"GB","type":"facility","lineage":["https://openalex.org/I2800994460"]}],"countries":["GB"],"is_corresponding":false,"raw_author_name":"G. M\u00f6hle","raw_affiliation_strings":["BRE, Garston, Watford WD25 9XX, UK"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"BRE, Garston, Watford WD25 9XX, UK","institution_ids":["https://openalex.org/I2800994460"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5110027201","display_name":"Derrick Crump","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I2800994460","display_name":"Building Research Establishment","ror":"https://ror.org/02fmkev06","country_code":"GB","type":"facility","lineage":["https://openalex.org/I2800994460"]}],"countries":["GB"],"is_corresponding":false,"raw_author_name":"D. Crump","raw_affiliation_strings":["BRE, Garston, Watford WD25 9XX, UK"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"BRE, Garston, Watford WD25 9XX, UK","institution_ids":["https://openalex.org/I2800994460"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5087698035","display_name":"Vincent M. Brown","orcid":"https://orcid.org/0000-0003-4141-1458","observed_orcids":["https://orcid.org/0000-0003-4141-1458"]},"institutions":[{"id":"https://openalex.org/I2800994460","display_name":"Building Research Establishment","ror":"https://ror.org/02fmkev06","country_code":"GB","type":"facility","lineage":["https://openalex.org/I2800994460"]}],"countries":["GB"],"is_corresponding":false,"raw_author_name":"V. Brown","raw_affiliation_strings":["BRE, Garston, Watford WD25 9XX, UK"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"BRE, Garston, Watford WD25 9XX, UK","institution_ids":["https://openalex.org/I2800994460"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5028428571","display_name":"Charles Haig Hunter","orcid":"https://orcid.org/0000-0001-5483-2521","observed_orcids":["https://orcid.org/0000-0001-5483-2521"]},"institutions":[{"id":"https://openalex.org/I2800994460","display_name":"Building Research Establishment","ror":"https://ror.org/02fmkev06","country_code":"GB","type":"facility","lineage":["https://openalex.org/I2800994460"]}],"countries":["GB"],"is_corresponding":false,"raw_author_name":"C. Hunter","raw_affiliation_strings":["BRE, Garston, Watford WD25 9XX, UK"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"BRE, Garston, Watford WD25 9XX, UK","institution_ids":["https://openalex.org/I2800994460"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5059598304","display_name":"Richard W. Squire","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I2800994460","display_name":"Building Research Establishment","ror":"https://ror.org/02fmkev06","country_code":"GB","type":"facility","lineage":["https://openalex.org/I2800994460"]}],"countries":["GB"],"is_corresponding":false,"raw_author_name":"R. Squire","raw_affiliation_strings":["BRE, Garston, Watford WD25 9XX, UK"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"BRE, Garston, Watford WD25 9XX, UK","institution_ids":["https://openalex.org/I2800994460"]}]},{"author_position":"middle","author":{"id":null,"display_name":"H. Mann","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I2800994460","display_name":"Building Research Establishment","ror":"https://ror.org/02fmkev06","country_code":"GB","type":"facility","lineage":["https://openalex.org/I2800994460"]}],"countries":["GB"],"is_corresponding":false,"raw_author_name":"H. Mann","raw_affiliation_strings":["BRE, Garston, Watford WD25 9XX, UK"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"BRE, Garston, Watford WD25 9XX, UK","institution_ids":["https://openalex.org/I2800994460"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5011071371","display_name":"Gary J. Raw","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I2800994460","display_name":"Building Research Establishment","ror":"https://ror.org/02fmkev06","country_code":"GB","type":"facility","lineage":["https://openalex.org/I2800994460"]}],"countries":["GB"],"is_corresponding":false,"raw_author_name":"G. J. Raw","raw_affiliation_strings":["BRE, Garston, Watford WD25 9XX, UK"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"BRE, Garston, Watford WD25 9XX, UK","institution_ids":["https://openalex.org/I2800994460"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I2800994460"],"apc_list":{"value":4400,"currency":"USD","value_usd":4400},"apc_paid":null,"fwci":1.9207,"has_fulltext":true,"cited_by_count":26,"citation_normalized_percentile":{"value":0.82466202,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":88,"max":95},"biblio":{"volume":"12","issue":"3","first_page":"139","last_page":"149"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11002","display_name":"Indoor Air Quality and Microbial Exposure","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2307","display_name":"Health, Toxicology and Mutagenesis"},"field":{"id":"https://openalex.org/fields/23","display_name":"Environmental Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11002","display_name":"Indoor Air Quality and Microbial Exposure","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2307","display_name":"Health, Toxicology and Mutagenesis"},"field":{"id":"https://openalex.org/fields/23","display_name":"Environmental Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":9.999999747378752e-05,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10990","display_name":"Infection Control and Ventilation","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2740","display_name":"Pulmonary and Respiratory Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/indoor-air-quality","display_name":"indoor air quality","score":0.9390000104904175},{"id":"https://openalex.org/keywords/indoor-air-pollutants","display_name":"indoor air pollutants","score":0.7289999723434448},{"id":"https://openalex.org/keywords/residential-homes","display_name":"residential homes","score":0.4480000138282776},{"id":"https://openalex.org/keywords/office-buildings","display_name":"office buildings","score":1.0},{"id":"https://openalex.org/keywords/occupant-exposure","display_name":"occupant exposure","score":0.5820000171661377},{"id":"https://openalex.org/keywords/air-quality-guidelines","display_name":"air quality guidelines","score":0.7450000047683716},{"id":"https://openalex.org/keywords/measurement-strategy","display_name":"measurement strategy","score":0.5329999923706055}],"concepts":[{"id":"https://openalex.org/C65469","wikidata":"https://www.wikidata.org/wiki/Q905504","display_name":"Indoor air quality","level":2,"score":0.8908790349960327},{"id":"https://openalex.org/C2780385302","wikidata":"https://www.wikidata.org/wiki/Q367158","display_name":"Protocol (science)","level":3,"score":0.7472935318946838},{"id":"https://openalex.org/C170154142","wikidata":"https://www.wikidata.org/wiki/Q150737","display_name":"Architectural engineering","level":1,"score":0.4842228889465332},{"id":"https://openalex.org/C2779530757","wikidata":"https://www.wikidata.org/wiki/Q1207505","display_name":"Quality (philosophy)","level":2,"score":0.450040727853775},{"id":"https://openalex.org/C2993878198","wikidata":"https://www.wikidata.org/wiki/Q905504","display_name":"Indoor air","level":2,"score":0.43220919370651245},{"id":"https://openalex.org/C200457457","wikidata":"https://www.wikidata.org/wiki/Q584049","display_name":"Ventilation (architecture)","level":2,"score":0.42223894596099854},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.42058658599853516},{"id":"https://openalex.org/C126314574","wikidata":"https://www.wikidata.org/wiki/Q2364111","display_name":"Air quality index","level":2,"score":0.41137802600860596},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.27072417736053467},{"id":"https://openalex.org/C87717796","wikidata":"https://www.wikidata.org/wiki/Q146326","display_name":"Environmental engineering","level":1,"score":0.21683278679847717},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.12459206581115723},{"id":"https://openalex.org/C142724271","wikidata":"https://www.wikidata.org/wiki/Q7208","display_name":"Pathology","level":1,"score":0.0},{"id":"https://openalex.org/C138885662","wikidata":"https://www.wikidata.org/wiki/Q5891","display_name":"Philosophy","level":0,"score":0.0},{"id":"https://openalex.org/C204787440","wikidata":"https://www.wikidata.org/wiki/Q188504","display_name":"Alternative medicine","level":2,"score":0.0},{"id":"https://openalex.org/C153294291","wikidata":"https://www.wikidata.org/wiki/Q25261","display_name":"Meteorology","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.0},{"id":"https://openalex.org/C111472728","wikidata":"https://www.wikidata.org/wiki/Q9471","display_name":"Epistemology","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1177/1420326x03012003001","doi":"https://doi.org/10.1177/1420326x03012003001","is_oa":true,"landing_page_url":"https://doi.org/10.1177/1420326x03012003001","pdf_url":"https://journals.sagepub.com/doi/pdf/10.1177/1420326X03012003001?download=true","source":{"id":"https://openalex.org/S163818028","display_name":"Indoor and Built Environment","issn_l":"1420-326X","issn":["1420-326X","1423-0070"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["anvur-scientific","cwts-core","dongbi-c","jufo-1","ki-jl-1","norway-1","poland-70","russia-white-list-1","vabb-shw"],"host_organization":"https://openalex.org/P4310320017","host_organization_name":"SAGE Publishing","host_organization_lineage":["https://openalex.org/P4310320017"],"host_organization_lineage_names":["SAGE Publishing"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Indoor and Built Environment","raw_type":"journal-article"}],"best_oa_location":{"id":"doi:10.1177/1420326x03012003001","doi":"https://doi.org/10.1177/1420326x03012003001","is_oa":true,"landing_page_url":"https://doi.org/10.1177/1420326x03012003001","pdf_url":"https://journals.sagepub.com/doi/pdf/10.1177/1420326X03012003001?download=true","source":{"id":"https://openalex.org/S163818028","display_name":"Indoor and Built Environment","issn_l":"1420-326X","issn":["1420-326X","1423-0070"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["anvur-scientific","cwts-core","dongbi-c","jufo-1","ki-jl-1","norway-1","poland-70","russia-white-list-1","vabb-shw"],"host_organization":"https://openalex.org/P4310320017","host_organization_name":"SAGE Publishing","host_organization_lineage":["https://openalex.org/P4310320017"],"host_organization_lineage_names":["SAGE Publishing"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Indoor and Built Environment","raw_type":"journal-article"},"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/3","display_name":"Good health and well-being","score":0.8048999905586243}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":true,"grobid_xml":true},"content_urls":{"pdf":"https://content.openalex.org/works/W2016734896.pdf","grobid_xml":"https://content.openalex.org/works/W2016734896.grobid-xml"},"referenced_works_count":4,"referenced_works":["https://openalex.org/W1976577765","https://openalex.org/W2036225380","https://openalex.org/W2049460977","https://openalex.org/W2165625566"],"related_works":["https://openalex.org/W4387681685","https://openalex.org/W2033744384","https://openalex.org/W4256042729","https://openalex.org/W2013783846","https://openalex.org/W4256304313","https://openalex.org/W4390952097","https://openalex.org/W43698960","https://openalex.org/W2083820404","https://openalex.org/W6987677077","https://openalex.org/W2946686503"],"abstract_inverted_index":{"The":[0,50,94,134],"main":[1],"exposure":[2],"to":[3,42],"air":[4,46,122],"pollutants":[5],"for":[6,36],"most":[7],"people":[8],"occurs":[9],"in":[10,70,132],"indoor":[11,45],"environments":[12],"and":[13,23,25,57,80,90,125,148],"this":[14],"can":[15,137],"have":[16],"an":[17,44,62,66,145],"important":[18,67],"influence":[19],"on":[20],"their":[21],"health":[22],"well-being":[24],"affect":[26],"productivity":[27],"at":[28],"the":[29,37,55,59,77,108,111],"workplace.":[30],"BRE":[31,135],"has":[32],"prepared":[33],"a":[34,85,118],"protocol":[35,79,96,136],"measurement":[38],"of":[39,61,87,110,113,117,120],"key":[40],"parameters":[41,115],"undertake":[43],"quality":[47,123],"(IAQ)":[48],"assessment.":[49,73],"measurements":[51,112],"required":[52],"depend":[53],"upon":[54],"objectives":[56],"therefore":[58],"design":[60],"appropriate":[63],"strategy":[64],"is":[65],"first":[68],"stage":[69],"any":[71],"IAQ":[72,95,146],"This":[74],"paper":[75],"summarises":[76],"recommended":[78],"reports":[81],"its":[82],"evaluation":[83],"by":[84,101,142,149],"study":[86],"10":[88,91],"homes":[89],"office":[92],"buildings.":[93,133],"was":[97],"generally":[98],"well":[99],"accepted":[100],"occupants.":[102],"There":[103],"are":[104],"problems":[105],"with":[106],"evaluating":[107],"significance":[109],"some":[114],"because":[116],"lack":[119],"relevant":[121],"guidelines":[124],"data":[126],"about":[127,153],"concentrations":[128],"that":[129],"normally":[130],"occur":[131],"be":[138],"used":[139],"as":[140],"guidance":[141],"specialists":[143],"undertaking":[144],"assessment":[147],"building":[150],"owners/managers":[151],"concerned":[152],"IAQ.":[154]},"counts_by_year":[{"year":2025,"cited_by_count":2},{"year":2023,"cited_by_count":1},{"year":2020,"cited_by_count":1},{"year":2016,"cited_by_count":1},{"year":2013,"cited_by_count":2},{"year":2012,"cited_by_count":1}],"updated_date":"2026-11-04T10:54:05.112534","created_date":"2016-06-24T00:00:00"}
