{"id":"https://openalex.org/W2016603337","doi":"https://doi.org/10.1016/j.egypro.2012.11.123","title":"Office Buildings Cooling Need in the Italian Climatic Context: Assessing the Performances of Typical Envelopes","display_name":"Office Buildings Cooling Need in the Italian Climatic Context: Assessing the Performances of Typical Envelopes","alternate_titles":[],"publication_year":2012,"publication_date":"2012-01-01","ids":{"openalex":"https://openalex.org/W2016603337","doi":"https://doi.org/10.1016/j.egypro.2012.11.123","mag":"2016603337"},"language":"en","primary_location":{"id":"doi:10.1016/j.egypro.2012.11.123","doi":"https://doi.org/10.1016/j.egypro.2012.11.123","is_oa":true,"landing_page_url":"https://doi.org/10.1016/j.egypro.2012.11.123","pdf_url":null,"source":{"id":"https://openalex.org/S75069817","display_name":"Energy Procedia","issn_l":"1876-6102","issn":["1876-6102"],"is_oa":true,"is_in_doaj":false,"is_core":true,"listed_in":["anvur-scientific","cwts-core","jufo-1"],"host_organization":"https://openalex.org/P4310320990","host_organization_name":"Elsevier BV","host_organization_lineage":["https://openalex.org/P4310320990"],"host_organization_lineage_names":["Elsevier BV"],"type":"conference"},"license":"cc-by-nc-nd","license_id":"https://openalex.org/licenses/cc-by-nc-nd","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Energy Procedia","raw_type":"journal-article"},"parent_works":[],"lineage":["https://openalex.org/W2016603337"],"child_works_count":0,"pull_notice_works":[],"type":"conference-paper","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"diamond","oa_url":"https://doi.org/10.1016/j.egypro.2012.11.123","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5064560221","display_name":"Simone Ferrari","type":null,"orcid":"https://orcid.org/0000-0001-5175-9445","observed_orcids":["https://orcid.org/0000-0001-5175-9445"]},"acted_on_behalf_of":[],"institutions":[{"id":"https://openalex.org/I93860229","display_name":"Politecnico di Milano","ror":"https://ror.org/01nffqt88","country_code":"IT","type":"education","lineage":["https://openalex.org/I93860229"]}],"countries":["IT"],"is_corresponding":true,"contributor_roles":[],"raw_author_name":"Simone Ferrari","raw_affiliation_strings":["Department of Building Environment Science and Technology (BEST), Politecnico di Milano, Via Bonardi 3, 20133 Milano, Italy","Department of Building Environment Science & Technology (BEST), Politecnico di Milano, Via Bonardi 3, 20133 Milano, Italy"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Building Environment Science and Technology (BEST), Politecnico di Milano, Via Bonardi 3, 20133 Milano, Italy","institution_ids":["https://openalex.org/I93860229"]},{"raw_affiliation_string":"Department of Building Environment Science & Technology (BEST), Politecnico di Milano, Via Bonardi 3, 20133 Milano, Italy","institution_ids":["https://openalex.org/I93860229"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5002320864","display_name":"Valentina Zanotto","type":null,"orcid":null,"observed_orcids":[]},"acted_on_behalf_of":[],"institutions":[{"id":"https://openalex.org/I93860229","display_name":"Politecnico di Milano","ror":"https://ror.org/01nffqt88","country_code":"IT","type":"education","lineage":["https://openalex.org/I93860229"]}],"countries":["IT"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"Valentina Zanotto","raw_affiliation_strings":["Department of Building Environment Science and Technology (BEST), Politecnico di Milano, Via Bonardi 3, 20133 Milano, Italy","Department of Building Environment Science & Technology (BEST), Politecnico di Milano, Via Bonardi 3, 20133 Milano, Italy"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Building Environment Science and Technology (BEST), Politecnico di Milano, Via Bonardi 3, 20133 Milano, Italy","institution_ids":["https://openalex.org/I93860229"]},{"raw_affiliation_string":"Department of Building Environment Science & Technology (BEST), Politecnico di Milano, Via Bonardi 3, 20133 Milano, Italy","institution_ids":["https://openalex.org/I93860229"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":["https://openalex.org/A5064560221"],"corresponding_institution_ids":["https://openalex.org/I93860229"],"apc_list":null,"apc_paid":null,"fwci":4.473,"has_fulltext":true,"cited_by_count":24,"reviewed_by_count":0,"citation_normalized_percentile":{"value":0.92252082,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":86,"max":98},"biblio":{"volume":"30","issue":null,"first_page":"1099","last_page":"1109"},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.9955999851226807,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.9955999851226807,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13263","display_name":"Building energy efficiency and sustainability","score":0.003100000089034438,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10766","display_name":"Urban Heat Island Mitigation","score":9.999999747378752e-05,"subfield":{"id":"https://openalex.org/subfields/2305","display_name":"Environmental Engineering"},"field":{"id":"https://openalex.org/fields/23","display_name":"Environmental Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/office-buildings","display_name":"office buildings","score":0.996999979019165},{"id":"https://openalex.org/keywords/cooling-demand","display_name":"cooling demand","score":0.7429999709129333},{"id":"https://openalex.org/keywords/building-envelope","display_name":"building envelope","score":0.7910000085830688},{"id":"https://openalex.org/keywords/thermal-performance","display_name":"thermal performance","score":0.6579999923706055},{"id":"https://openalex.org/keywords/italian-climate","display_name":"Italian climate","score":0.6650000214576721},{"id":"https://openalex.org/keywords/glazing","display_name":"glazing","score":0.5120000243186951},{"id":"https://openalex.org/keywords/thermal-insulation","display_name":"thermal insulation","score":0.6729999780654907},{"id":"https://openalex.org/keywords/building-age","display_name":"building age","score":0.39500001072883606},{"id":"https://openalex.org/keywords/thermal-energy-storage","display_name":"thermal energy storage","score":0.546999990940094},{"id":"https://openalex.org/keywords/internal-mass","display_name":"internal mass","score":0.3319999873638153},{"id":"https://openalex.org/keywords/building-energy-control","display_name":"building energy standards","score":0.46299999952316284}],"concepts":[{"id":"https://openalex.org/C196803488","wikidata":"https://www.wikidata.org/wiki/Q4986592","display_name":"Building envelope","level":3,"score":0.8412281274795532},{"id":"https://openalex.org/C65155139","wikidata":"https://www.wikidata.org/wiki/Q5380912","display_name":"Envelope (radar)","level":3,"score":0.84022057056427},{"id":"https://openalex.org/C2779343474","wikidata":"https://www.wikidata.org/wiki/Q3109175","display_name":"Context (archaeology)","level":2,"score":0.7515811920166016},{"id":"https://openalex.org/C170154142","wikidata":"https://www.wikidata.org/wiki/Q150737","display_name":"Architectural engineering","level":1,"score":0.6093763709068298},{"id":"https://openalex.org/C79795727","wikidata":"https://www.wikidata.org/wiki/Q3068508","display_name":"Passive cooling","level":3,"score":0.5399615168571472},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.4321354627609253},{"id":"https://openalex.org/C204530211","wikidata":"https://www.wikidata.org/wiki/Q752823","display_name":"Thermal","level":2,"score":0.43051066994667053},{"id":"https://openalex.org/C147176958","wikidata":"https://www.wikidata.org/wiki/Q77590","display_name":"Civil engineering","level":1,"score":0.4246489405632019},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.39554932713508606},{"id":"https://openalex.org/C153294291","wikidata":"https://www.wikidata.org/wiki/Q25261","display_name":"Meteorology","level":1,"score":0.15617889165878296},{"id":"https://openalex.org/C146978453","wikidata":"https://www.wikidata.org/wiki/Q3798668","display_name":"Aerospace engineering","level":1,"score":0.13299670815467834},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.12075060606002808},{"id":"https://openalex.org/C205649164","wikidata":"https://www.wikidata.org/wiki/Q1071","display_name":"Geography","level":0,"score":0.09244245290756226},{"id":"https://openalex.org/C554190296","wikidata":"https://www.wikidata.org/wiki/Q47528","display_name":"Radar","level":2,"score":0.0},{"id":"https://openalex.org/C151730666","wikidata":"https://www.wikidata.org/wiki/Q7205","display_name":"Paleontology","level":1,"score":0.0}],"mesh":[],"locations_count":3,"locations":[{"id":"doi:10.1016/j.egypro.2012.11.123","doi":"https://doi.org/10.1016/j.egypro.2012.11.123","is_oa":true,"landing_page_url":"https://doi.org/10.1016/j.egypro.2012.11.123","pdf_url":null,"source":{"id":"https://openalex.org/S75069817","display_name":"Energy Procedia","issn_l":"1876-6102","issn":["1876-6102"],"is_oa":true,"is_in_doaj":false,"is_core":true,"listed_in":["anvur-scientific","cwts-core","jufo-1"],"host_organization":"https://openalex.org/P4310320990","host_organization_name":"Elsevier BV","host_organization_lineage":["https://openalex.org/P4310320990"],"host_organization_lineage_names":["Elsevier BV"],"type":"conference"},"license":"cc-by-nc-nd","license_id":"https://openalex.org/licenses/cc-by-nc-nd","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Energy Procedia","raw_type":"journal-article"},{"id":"pmh:oai:re.public.polimi.it:11311/710141","doi":null,"is_oa":false,"landing_page_url":"http://hdl.handle.net/11311/710141","pdf_url":null,"source":{"id":"https://openalex.org/S4306400312","display_name":"Virtual Community of Pathological Anatomy (University of Castilla La Mancha)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I79189158","host_organization_name":"University of Castilla-La Mancha","host_organization_lineage":["https://openalex.org/I79189158"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"info:eu-repo/semantics/article"},{"id":"pmh:oai:zenodo.org:33806","doi":null,"is_oa":true,"landing_page_url":"https://www.openaccessrepository.it/record/33806","pdf_url":null,"source":{"id":"https://openalex.org/S4306402478","display_name":"INFM-OAR (INFN Catania)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I4210116497","host_organization_name":"Istituto Nazionale di Fisica Nucleare, Sezione di Catania","host_organization_lineage":["https://openalex.org/I4210116497"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by-nc-nd","license_id":"https://openalex.org/licenses/cc-by-nc-nd","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"","raw_type":"info:eu-repo/semantics/article"}],"best_oa_location":{"id":"doi:10.1016/j.egypro.2012.11.123","doi":"https://doi.org/10.1016/j.egypro.2012.11.123","is_oa":true,"landing_page_url":"https://doi.org/10.1016/j.egypro.2012.11.123","pdf_url":null,"source":{"id":"https://openalex.org/S75069817","display_name":"Energy Procedia","issn_l":"1876-6102","issn":["1876-6102"],"is_oa":true,"is_in_doaj":false,"is_core":true,"listed_in":["anvur-scientific","cwts-core","jufo-1"],"host_organization":"https://openalex.org/P4310320990","host_organization_name":"Elsevier BV","host_organization_lineage":["https://openalex.org/P4310320990"],"host_organization_lineage_names":["Elsevier BV"],"type":"conference"},"license":"cc-by-nc-nd","license_id":"https://openalex.org/licenses/cc-by-nc-nd","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Energy Procedia","raw_type":"journal-article"},"sustainable_development_goals":[{"score":0.821399986743927,"display_name":"Climate action","id":"https://metadata.un.org/sdg/13"},{"score":0.5142999887466431,"display_name":"Sustainable cities and communities","id":"https://metadata.un.org/sdg/11"},{"score":0.4000000059604645,"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":true,"pdf":true},"content_urls":{"pdf":"https://content.openalex.org/works/W2016603337.pdf","grobid_xml":"https://content.openalex.org/works/W2016603337.grobid-xml"},"referenced_works_count":9,"referenced_works":["https://openalex.org/W111007040","https://openalex.org/W218675440","https://openalex.org/W1968590548","https://openalex.org/W2023477350","https://openalex.org/W2050108708","https://openalex.org/W2063806086","https://openalex.org/W2593305974","https://openalex.org/W2607407650","https://openalex.org/W7164616994"],"related_works":["https://openalex.org/W2731548761","https://openalex.org/W7036982440","https://openalex.org/W4396678597","https://openalex.org/W2395637740","https://openalex.org/W2406570212","https://openalex.org/W4417046260","https://openalex.org/W787967244","https://openalex.org/W2553205113","https://openalex.org/W3120338958","https://openalex.org/W3157823180"],"abstract_inverted_index":{"This":[0],"study":[1],"assesses":[2],"the":[3,17,24,39,43,51,61,65,69,73,77,88,92,117,121],"cooling":[4,97],"thermal":[5,45],"energy":[6],"need":[7],"of":[8],"office":[9],"buildings":[10,70],"that":[11,27,37,50],"can":[12],"represent":[13],"typical":[14],"cases":[15],"within":[16],"Italian":[18],"context,":[19],"in":[20],"particular":[21],"defined":[22],"by":[23,72,101,120],"envelope":[25,44,93],"solutions":[26,36,55],"belong":[28],"to":[29,115],"three":[30],"main":[31],"construction":[32],"ages,":[33],"including":[34],"new":[35],"meet":[38],"current":[40],"requirements":[41,90],"for":[42,91],"properties.":[46],"The":[47,95],"results":[48],"show":[49],"large-glazed":[52],"and":[53],"lighter":[54],"(also":[56],"newly":[57,102],"built,":[58],"consistent":[59],"with":[60,87],"recent":[62,89],"standards)":[63],"reveal":[64],"worst":[66],"behavior,":[67],"while":[68],"characterized":[71],"lowest":[74],"needs":[75],"are":[76,99,108],"old":[78],"conventional":[79],"ones,":[80],"even":[81],"though":[82],"they":[83,107],"do":[84],"not":[85],"comply":[86],"components.":[94],"same":[96],"performances":[98],"achieved":[100],"built":[103],"insulated":[104],"envelopes":[105],"if":[106],"\u201cconventionally-glazed\u201d,":[109],"but":[110],"only":[111],"when":[112],"a":[113],"strategy":[114],"loose":[116],"heat":[118],"stored":[119],"massive":[122],"internal":[123],"surfaces":[124],"is":[125],"adopted.":[126]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W2016603337","counts_by_year":[{"year":2025,"cited_by_count":1},{"year":2024,"cited_by_count":2},{"year":2023,"cited_by_count":2},{"year":2022,"cited_by_count":1},{"year":2021,"cited_by_count":2},{"year":2020,"cited_by_count":2},{"year":2019,"cited_by_count":1},{"year":2018,"cited_by_count":6},{"year":2017,"cited_by_count":3},{"year":2015,"cited_by_count":3},{"year":2013,"cited_by_count":1}],"updated_date":"2026-11-23T12:01:36.302904","created_date":"2016-06-24T00:00:00"}
