{"id":"https://openalex.org/W2016397167","doi":"https://doi.org/10.1109/icpadm.2006.284315","title":"Short Circuit Currents Due to Thermal Instability on TR-XLPE 12/20 kV Ground Cable","display_name":"Short Circuit Currents Due to Thermal Instability on TR-XLPE 12/20 kV Ground Cable","publication_year":2006,"publication_date":"2006-06-01","ids":{"openalex":"https://openalex.org/W2016397167","doi":"https://doi.org/10.1109/icpadm.2006.284315","mag":"2016397167"},"language":"en","primary_location":{"id":"doi:10.1109/icpadm.2006.284315","doi":"https://doi.org/10.1109/icpadm.2006.284315","is_oa":false,"landing_page_url":"https://doi.org/10.1109/icpadm.2006.284315","pdf_url":null,"source":{"id":"https://openalex.org/S7407089292","display_name":"International Conference on Properties and Applications of Dielectric Materials (ICPADM)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2006 IEEE 8th International Conference on Properties and applications of Dielectric Materials","raw_type":"proceedings-article"},"volume":null,"type":"conference-paper","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5057260606","display_name":"Syamsir Abduh","orcid":"https://orcid.org/0009-0000-7984-8511","observed_orcids":["https://orcid.org/0009-0000-7984-8511"]},"institutions":[{"id":"https://openalex.org/I147337026","display_name":"Universitas Trisakti","ror":"https://ror.org/019fnr381","country_code":"ID","type":"education","lineage":["https://openalex.org/I147337026"]}],"countries":["ID"],"is_corresponding":true,"raw_author_name":"Syamsir Abduh","raw_affiliation_strings":["Electrical Engineering Department, Trisakti University, Jakarta, Indonesia","Electrical Engineering Department, Trisakti University, Jl. Kyai Tapa No. 1 Grogol Jakarta 11440. E-mail: the-abduh@hotmail.com"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Electrical Engineering Department, Trisakti University, Jakarta, Indonesia","institution_ids":["https://openalex.org/I147337026"]},{"raw_affiliation_string":"Electrical Engineering Department, Trisakti University, Jl. Kyai Tapa No. 1 Grogol Jakarta 11440. E-mail: the-abduh@hotmail.com","institution_ids":["https://openalex.org/I147337026"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":["https://openalex.org/A5057260606"],"corresponding_institution_ids":["https://openalex.org/I147337026"],"apc_list":null,"apc_paid":null,"fwci":0.5286,"has_fulltext":false,"cited_by_count":3,"citation_normalized_percentile":{"value":0.51724854,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":88,"max":93},"biblio":{"volume":null,"issue":null,"first_page":"869","last_page":"872"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T12804","display_name":"Thermal Analysis in Power Transmission","score":0.9717000126838684,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12804","display_name":"Thermal Analysis in Power Transmission","score":0.9717000126838684,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10511","display_name":"High voltage insulation and dielectric phenomena","score":0.023099999874830246,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14502","display_name":"High-Voltage Power Transmission Systems","score":0.0010999999940395355,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/short-circuit-current","display_name":"short-circuit current","score":0.9580000042915344},{"id":"https://openalex.org/keywords/thermal-instability","display_name":"thermal instability","score":0.9150000214576721},{"id":"https://openalex.org/keywords/xlpe-cables","display_name":"XLPE cables","score":0.6620000004768372},{"id":"https://openalex.org/keywords/adiabatic-method","display_name":"adiabatic method","score":0.8939999938011169},{"id":"https://openalex.org/keywords/cable-burial-depth","display_name":"cable burial depth","score":0.9649999737739563},{"id":"https://openalex.org/keywords/cable-aging","display_name":"cable aging","score":0.5759999752044678},{"id":"https://openalex.org/keywords/cable-insulation-failure","display_name":"cable insulation failure","score":0.6380000114440918}],"concepts":[{"id":"https://openalex.org/C109663097","wikidata":"https://www.wikidata.org/wiki/Q182453","display_name":"Adiabatic process","level":2,"score":0.6586660146713257},{"id":"https://openalex.org/C202374169","wikidata":"https://www.wikidata.org/wiki/Q124291","display_name":"Electrical conductor","level":2,"score":0.5915524959564209},{"id":"https://openalex.org/C140311924","wikidata":"https://www.wikidata.org/wiki/Q200928","display_name":"Electric power transmission","level":2,"score":0.5713962316513062},{"id":"https://openalex.org/C68583231","wikidata":"https://www.wikidata.org/wiki/Q206907","display_name":"Short circuit","level":3,"score":0.5644508600234985},{"id":"https://openalex.org/C57879066","wikidata":"https://www.wikidata.org/wiki/Q41217","display_name":"Mechanics","level":1,"score":0.5597225427627563},{"id":"https://openalex.org/C33441834","wikidata":"https://www.wikidata.org/wiki/Q693004","display_name":"Transmission line","level":2,"score":0.5522326827049255},{"id":"https://openalex.org/C2777300110","wikidata":"https://www.wikidata.org/wiki/Q1577470","display_name":"High-voltage cable","level":3,"score":0.5514819622039795},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.5506030917167664},{"id":"https://openalex.org/C34800285","wikidata":"https://www.wikidata.org/wiki/Q5159395","display_name":"Conductor","level":2,"score":0.5231101512908936},{"id":"https://openalex.org/C72688512","wikidata":"https://www.wikidata.org/wiki/Q908282","display_name":"Thermal runaway","level":4,"score":0.5024755001068115},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.45304396748542786},{"id":"https://openalex.org/C168993435","wikidata":"https://www.wikidata.org/wiki/Q6501125","display_name":"Ground","level":2,"score":0.4435100555419922},{"id":"https://openalex.org/C117926987","wikidata":"https://www.wikidata.org/wiki/Q210009","display_name":"Joule heating","level":2,"score":0.4322183132171631},{"id":"https://openalex.org/C207821765","wikidata":"https://www.wikidata.org/wiki/Q405372","display_name":"Instability","level":2,"score":0.4233143925666809},{"id":"https://openalex.org/C7943809","wikidata":"https://www.wikidata.org/wiki/Q1977384","display_name":"Ampacity","level":3,"score":0.41178014874458313},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.3882874846458435},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.35915452241897583},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.2578763961791992},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.09246250987052917},{"id":"https://openalex.org/C97355855","wikidata":"https://www.wikidata.org/wiki/Q11473","display_name":"Thermodynamics","level":1,"score":0.08204039931297302},{"id":"https://openalex.org/C159985019","wikidata":"https://www.wikidata.org/wiki/Q181790","display_name":"Composite material","level":1,"score":0.07626625895500183},{"id":"https://openalex.org/C555008776","wikidata":"https://www.wikidata.org/wiki/Q267298","display_name":"Battery (electricity)","level":3,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/icpadm.2006.284315","doi":"https://doi.org/10.1109/icpadm.2006.284315","is_oa":false,"landing_page_url":"https://doi.org/10.1109/icpadm.2006.284315","pdf_url":null,"source":{"id":"https://openalex.org/S7407089292","display_name":"International Conference on Properties and Applications of Dielectric Materials (ICPADM)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2006 IEEE 8th International Conference on Properties and applications of Dielectric Materials","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.5378999710083008,"id":"https://metadata.un.org/sdg/9","display_name":"Industry, innovation and infrastructure"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W2153810854","https://openalex.org/W4244123658","https://openalex.org/W2902333413","https://openalex.org/W4414524044","https://openalex.org/W2552582205","https://openalex.org/W2365648944","https://openalex.org/W2115051227","https://openalex.org/W7160330370","https://openalex.org/W4410390983","https://openalex.org/W4402127892"],"abstract_inverted_index":{"Short":[0],"circuit":[1,25,115,151],"current":[2,26],"constitutes":[3],"one":[4],"of":[5,8,13,23,74,84,92,97,106,113,134,156,160],"the":[6,49,58,66,72,78,82,87,95,154,158],"forms":[7],"disturbance":[9,27],"on":[10,34,57,65,80,86],"transmission":[11,17],"system":[12,18],"electric":[14,76],"energy,":[15],"including":[16],"through":[19],"underground":[20],"cable.":[21,67,88],"Effects":[22],"short":[24,114,135,150],"are,":[28],"among":[29],"other":[30],"things:":[31],"mechanical":[32],"damage":[33],"cable":[35,162],"due":[36,53],"to":[37,54,139,148],"electromagnetic":[38],"force":[39],"from":[40],"repulsion":[41],"between":[42,45,166,170],"conductors":[43],"or":[44,77],"conductor":[46,59],"and":[47,60,103,124,168],"wrapper;":[48],"sharp":[50],"increased":[51],"temperature":[52],"joule":[55],"heat":[56],"wrapper":[61],"causing":[62],"thermal":[63],"instability":[64],"This":[68,89,108],"will":[69,144],"further":[70],"cause":[71],"occurrence":[73,83],"tree":[75],"failure":[79],"insulation;":[81],"aging":[85],"is":[90,105,129],"certainly":[91],"disadvantage":[93],"since":[94],"continuity":[96],"voltage":[98],"distribution":[99],"may":[100],"be":[101],"disturbed":[102],"investment":[104],"disadvantage.":[107],"paper":[109],"explains":[110],"calculation/":[111],"determination":[112],"currents":[116,152],"by":[117],"comparing":[118],"two":[119],"methods,":[120],"namely":[121],"adiabatic":[122,140],"method":[123,128,143],"non-adiabatic":[125,142],"method.":[126],"Non-adiabatic":[127],"applicable":[130],"for":[131],"all":[132],"durations":[133],"circuit.":[136],"If":[137],"compared":[138],"method,":[141],"give":[145],"significant":[146],"addition":[147],"permissible":[149],"in":[153],"case":[155],"choosing":[157],"type":[159],"backfill,":[161],"burying":[163],"depth,":[164],"distance":[165,169],"cables":[167],"lines":[171]},"counts_by_year":[{"year":2022,"cited_by_count":1},{"year":2020,"cited_by_count":1}],"updated_date":"2026-10-26T11:51:55.731654","created_date":"2016-06-24T00:00:00"}