{"id":"https://openalex.org/W2016288599","doi":"https://doi.org/10.1016/j.medengphy.2003.09.002","title":"Interface pressure sensor for IVRA and other biomedical applications","display_name":"Interface pressure sensor for IVRA and other biomedical applications","alternate_titles":[],"publication_year":2003,"publication_date":"2003-11-14","ids":{"openalex":"https://openalex.org/W2016288599","doi":"https://doi.org/10.1016/j.medengphy.2003.09.002","mag":"2016288599","pmid":"https://pubmed.ncbi.nlm.nih.gov/15036185"},"language":"en","primary_location":{"id":"doi:10.1016/j.medengphy.2003.09.002","doi":"https://doi.org/10.1016/j.medengphy.2003.09.002","is_oa":false,"landing_page_url":"https://doi.org/10.1016/j.medengphy.2003.09.002","pdf_url":null,"source":{"id":"https://openalex.org/S52939411","display_name":"Medical Engineering & Physics","issn_l":"1350-4533","issn":["1350-4533","1873-4030"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["anvur-scientific","cwts-core","dongbi-c","jufo-1","ki-jl-1","medline","norway-1","poland-70","russia-white-list-2","vabb-shw"],"host_organization":"https://openalex.org/P4310320083","host_organization_name":"IOP Publishing","host_organization_lineage":["https://openalex.org/P4310320083","https://openalex.org/P4310311669"],"host_organization_lineage_names":["IOP Publishing","Institute of Physics"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Medical Engineering &amp; Physics","raw_type":"journal-article"},"parent_works":[],"lineage":["https://openalex.org/W2016288599"],"child_works_count":0,"pull_notice_works":[],"type":"article","is_traditional":true,"indexed_in":["crossref","pubmed"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5083540972","display_name":"Vincent Casey","type":null,"orcid":"https://orcid.org/0000-0002-0701-526X","observed_orcids":["https://orcid.org/0000-0002-0701-526X"]},"acted_on_behalf_of":[],"institutions":[{"id":"https://openalex.org/I230495080","display_name":"University of Limerick","ror":"https://ror.org/00a0n9e72","country_code":"IE","type":"education","lineage":["https://openalex.org/I230495080"]}],"countries":["IE"],"is_corresponding":true,"contributor_roles":[],"raw_author_name":"V. Casey","raw_affiliation_strings":["Physics Department, University of Limerick, Limerick, Ireland. vincent.casey@ul.ie","Physics Department, University of Limerick, Limerick, Ireland"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Physics Department, University of Limerick, Limerick, Ireland. vincent.casey@ul.ie","institution_ids":["https://openalex.org/I230495080"]},{"raw_affiliation_string":"Physics Department, University of Limerick, Limerick, Ireland","institution_ids":["https://openalex.org/I230495080"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5076527179","display_name":"Samantha O'Sullivan","type":null,"orcid":"https://orcid.org/0000-0003-1171-815X","observed_orcids":["https://orcid.org/0000-0003-1171-815X"]},"acted_on_behalf_of":[],"institutions":[],"countries":[],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"S. O\u2019Sullivan","raw_affiliation_strings":["Boston Scientific, Galway, Ireland"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Boston Scientific, Galway, Ireland","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5038896862","display_name":"James A. McEwen","type":null,"orcid":"https://orcid.org/0000-0002-1459-1046","observed_orcids":["https://orcid.org/0000-0002-1459-1046"]},"acted_on_behalf_of":[],"institutions":[],"countries":[],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"J.A. McEwen","raw_affiliation_strings":["Western Clinical Engineering Ltd., 544-2660 Oak Street, Vancouver, BC, Canada V6H 3Z6"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Western Clinical Engineering Ltd., 544-2660 Oak Street, Vancouver, BC, Canada V6H 3Z6","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":["https://openalex.org/A5083540972"],"corresponding_institution_ids":["https://openalex.org/I230495080"],"apc_list":{"value":3170,"currency":"USD","value_usd":3170},"apc_paid":null,"fwci":0.621,"has_fulltext":false,"cited_by_count":6,"reviewed_by_count":0,"citation_normalized_percentile":{"value":0.74731423,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":86,"max":93},"biblio":{"volume":"26","issue":"2","first_page":"177","last_page":"182"},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T12564","display_name":"Sensor Technology and Measurement Systems","score":0.3978999853134155,"subfield":{"id":"https://openalex.org/subfields/3105","display_name":"Instrumentation"},"field":{"id":"https://openalex.org/fields/31","display_name":"Physics and Astronomy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12564","display_name":"Sensor Technology and Measurement Systems","score":0.3978999853134155,"subfield":{"id":"https://openalex.org/subfields/3105","display_name":"Instrumentation"},"field":{"id":"https://openalex.org/fields/31","display_name":"Physics and Astronomy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.2190999984741211,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14189","display_name":"Intravenous Infusion Technology and Safety","score":0.08179999887943268,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/pressure-sensors","display_name":"pressure sensors","score":0.7739999890327454},{"id":"https://openalex.org/keywords/intravenous-regional-anesthesia","display_name":"intravenous regional anesthesia","score":0.9850000143051147},{"id":"https://openalex.org/keywords/cuff-pressure-monitoring","display_name":"cuff pressure monitoring","score":0.492000013589859},{"id":"https://openalex.org/keywords/parallel-plate-capacitor","display_name":"parallel plate capacitor","score":0.925000011920929},{"id":"https://openalex.org/keywords/sensor-calibration","display_name":"sensor calibration","score":0.6489999890327454},{"id":"https://openalex.org/keywords/medical-device-safety","display_name":"medical device safety","score":0.4259999990463257}],"concepts":[{"id":"https://openalex.org/C2780017030","wikidata":"https://www.wikidata.org/wiki/Q368366","display_name":"Cuff","level":2,"score":0.6084025502204895},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.5103656649589539},{"id":"https://openalex.org/C136229726","wikidata":"https://www.wikidata.org/wiki/Q327092","display_name":"Biomedical engineering","level":1,"score":0.48006758093833923},{"id":"https://openalex.org/C2781355719","wikidata":"https://www.wikidata.org/wiki/Q2080698","display_name":"Deflection (physics)","level":2,"score":0.47465234994888306},{"id":"https://openalex.org/C113843644","wikidata":"https://www.wikidata.org/wiki/Q901882","display_name":"Interface (matter)","level":4,"score":0.4390637278556824},{"id":"https://openalex.org/C38052585","wikidata":"https://www.wikidata.org/wiki/Q252266","display_name":"Elastomer","level":2,"score":0.4110247492790222},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.3714115619659424},{"id":"https://openalex.org/C159985019","wikidata":"https://www.wikidata.org/wiki/Q181790","display_name":"Composite material","level":1,"score":0.18995872139930725},{"id":"https://openalex.org/C141071460","wikidata":"https://www.wikidata.org/wiki/Q40821","display_name":"Surgery","level":1,"score":0.15687784552574158},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.14132016897201538},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.08058434724807739},{"id":"https://openalex.org/C120665830","wikidata":"https://www.wikidata.org/wiki/Q14620","display_name":"Optics","level":1,"score":0.07780924439430237},{"id":"https://openalex.org/C196806460","wikidata":"https://www.wikidata.org/wiki/Q188603","display_name":"Capillary action","level":2,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C28413391","wikidata":"https://www.wikidata.org/wiki/Q785542","display_name":"Capillary number","level":3,"score":0.0}],"mesh":[{"descriptor_ui":"D000771","descriptor_name":"Anesthesia, Intravenous","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":true},{"descriptor_ui":"D001698","descriptor_name":"Biomedical Engineering","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D001698","descriptor_name":"Biomedical Engineering","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D002138","descriptor_name":"Calibration","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004581","descriptor_name":"Electronics","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012680","descriptor_name":"Sensitivity and Specificity","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D014111","descriptor_name":"Tourniquets","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D014160","descriptor_name":"Transducers, Pressure","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D015203","descriptor_name":"Reproducibility of Results","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D019544","descriptor_name":"Equipment Failure Analysis","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true}],"locations_count":2,"locations":[{"id":"doi:10.1016/j.medengphy.2003.09.002","doi":"https://doi.org/10.1016/j.medengphy.2003.09.002","is_oa":false,"landing_page_url":"https://doi.org/10.1016/j.medengphy.2003.09.002","pdf_url":null,"source":{"id":"https://openalex.org/S52939411","display_name":"Medical Engineering & Physics","issn_l":"1350-4533","issn":["1350-4533","1873-4030"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["anvur-scientific","cwts-core","dongbi-c","jufo-1","ki-jl-1","medline","norway-1","poland-70","russia-white-list-2","vabb-shw"],"host_organization":"https://openalex.org/P4310320083","host_organization_name":"IOP Publishing","host_organization_lineage":["https://openalex.org/P4310320083","https://openalex.org/P4310311669"],"host_organization_lineage_names":["IOP Publishing","Institute of Physics"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Medical Engineering &amp; Physics","raw_type":"journal-article"},{"id":"pmid:15036185","doi":null,"is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/15036185","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Medical engineering & physics","raw_type":"Evaluation Study"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/3","display_name":"Good health and well-being","score":0.6240000128746033}],"study_designs":[],"awards":[],"funders":[{"id":"https://openalex.org/F4320320834","display_name":"Enterprise Ireland","ror":"https://ror.org/023z51242"}],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":7,"referenced_works":["https://openalex.org/W1999029216","https://openalex.org/W2019665163","https://openalex.org/W2044882656","https://openalex.org/W2052343473","https://openalex.org/W2053501250","https://openalex.org/W2064638115","https://openalex.org/W2155579866"],"related_works":["https://openalex.org/W2096628175","https://openalex.org/W1965602700","https://openalex.org/W3041471100","https://openalex.org/W4400272406","https://openalex.org/W3005220049","https://openalex.org/W2005905354","https://openalex.org/W2018324201","https://openalex.org/W2107854013","https://openalex.org/W2003200291","https://openalex.org/W7170183770"],"abstract_inverted_index":{"The":[0,42,71,83,97],"fabrication":[1],"and":[2,67,111,150],"testing":[3],"of":[4,27,35,56,113,137],"a":[5,45,49,57,76,90],"minimally":[6],"intrusive":[7],"(2":[8],"mm":[9,12],"high,":[10],"10":[11],"diameter)":[13],"biomedical":[14],"interface":[15],"pressure":[16],"sensor":[17,43,72],"are":[18,22],"described.":[19],"Such":[20],"sensors":[21],"needed":[23],"for":[24,122],"the":[25,32,54,114,135],"implementation":[26],"improved":[28],"safety":[29],"features":[30],"in":[31,75,108],"next":[33],"generation":[34],"automated":[36],"intravenous":[37],"regional":[38],"anaesthesia":[39],"(IVRA)":[40],"systems.":[41],"utilizes":[44],"structured":[46],"elastomer":[47],"as":[48],"deflection":[50],"element":[51],"sandwiched":[52],"between":[53],"plates":[55],"parallel":[58],"plate":[59],"capacitor":[60],"device.":[61],"Simple":[62],"mechanical":[63],"modifications":[64],"allow":[65],"sensitivity":[66],"zero":[68],"offset":[69],"adjustment.":[70],"is":[73,85,99],"housed":[74],"package":[77],"machined":[78],"from":[79,106],"an":[80,93],"engineering":[81],"polymer.":[82],"device":[84,98],"easily":[86],"calibrated":[87],"using":[88],"either":[89],"bench-top":[91],"or":[92],"on-body":[94],"calibration":[95],"procedure.":[96],"particularly":[100],"sensitive":[101],"to":[102,155],"cuff":[103],"artefacts":[104],"arising":[105],"variations":[107],"cuff-wrap":[109],"tightness":[110],"folding":[112],"cuff.":[115],"As":[116],"such,":[117],"it":[118],"offers":[119],"some":[120],"promise":[121],"detecting":[123],"potential":[124],"hazard":[125],"conditions":[126],"which":[127],"can":[128],"occur":[129],"during":[130],"conventional":[131],"IVRA":[132],"procedures.":[133],"For":[134],"purpose":[136],"unit":[138],"conversion,":[139],"1":[140,143,145,148],"Pa":[141],"=":[142,147],"N/m2,":[144],"MPA":[146],"N/mm2":[149],"40":[151],"kPa":[152],"approximately":[153],"equal":[154],"300":[156],"mmHg.":[157]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W2016288599","counts_by_year":[{"year":2022,"cited_by_count":1},{"year":2021,"cited_by_count":1},{"year":2015,"cited_by_count":1},{"year":2012,"cited_by_count":1}],"updated_date":"2026-11-25T09:40:18.809321","created_date":"2016-06-24T00:00:00"}
