{"id":"https://openalex.org/W2015489731","doi":"https://doi.org/10.1080/15298660008984523","title":"Hazardous Peak Concentrations of Hydrogen Sulfide Gas Related to the Sewage Purification Process","display_name":"Hazardous Peak Concentrations of Hydrogen Sulfide Gas Related to the Sewage Purification Process","publication_year":2000,"publication_date":"2000-01-01","ids":{"openalex":"https://openalex.org/W2015489731","doi":"https://doi.org/10.1080/15298660008984523","mag":"2015489731","pmid":"https://pubmed.ncbi.nlm.nih.gov/10772623"},"language":"en","primary_location":{"id":"doi:10.1080/15298660008984523","doi":"https://doi.org/10.1080/15298660008984523","is_oa":false,"landing_page_url":"https://doi.org/10.1080/15298660008984523","pdf_url":null,"source":{"id":"https://openalex.org/S4210175721","display_name":"AIHAJ - American Industrial Hygiene Association","issn_l":"1529-8663","issn":["1529-8663","2163-3711"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core"],"host_organization":"https://openalex.org/P4310320547","host_organization_name":"Taylor & Francis","host_organization_lineage":["https://openalex.org/P4310320547","https://openalex.org/P4310320449"],"host_organization_lineage_names":["Taylor & Francis","Informa"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"AIHAJ - American Industrial Hygiene Association","raw_type":"journal-article"},"volume":null,"type":"article","indexed_in":["crossref","pubmed"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5051357471","display_name":"Per S\u2298strand","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I1332882736","display_name":"National Institute of Occupational Health","ror":"https://ror.org/04g3t6s80","country_code":"NO","type":"government","lineage":["https://openalex.org/I1332882736"]}],"countries":["NO"],"is_corresponding":false,"raw_author_name":"Per S\u2298strand","raw_affiliation_strings":["National Institute for Occupational Health, PB8149 Dep., 0033 Oslo, Norway; Current address: Center for Occupational and Environmental Medicine, The National Hospital, 0027 Oslo, Norway","Current address: Center for Occupational and Environmental Medicine, The National Hospital, 0027 Oslo, Norway","National Institute for Occupational Health, PB8149 Dep., 0033 Oslo, Norway"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"National Institute for Occupational Health, PB8149 Dep., 0033 Oslo, Norway; Current address: Center for Occupational and Environmental Medicine, The National Hospital, 0027 Oslo, Norway","institution_ids":["https://openalex.org/I1332882736"]},{"raw_affiliation_string":"Current address: Center for Occupational and Environmental Medicine, The National Hospital, 0027 Oslo, Norway","institution_ids":[]},{"raw_affiliation_string":"National Institute for Occupational Health, PB8149 Dep., 0033 Oslo, Norway","institution_ids":["https://openalex.org/I1332882736"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5109126898","display_name":"Bj\u2298rn Tvedt","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I1332882736","display_name":"National Institute of Occupational Health","ror":"https://ror.org/04g3t6s80","country_code":"NO","type":"government","lineage":["https://openalex.org/I1332882736"]}],"countries":["NO"],"is_corresponding":false,"raw_author_name":"Bj\u2298rn Tvedt","raw_affiliation_strings":["National Institute for Occupational Health, PB8149 Dep., 0033 Oslo, Norway"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"National Institute for Occupational Health, PB8149 Dep., 0033 Oslo, Norway","institution_ids":["https://openalex.org/I1332882736"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5005138074","display_name":"Wijnand Eduard","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I1332882736","display_name":"National Institute of Occupational Health","ror":"https://ror.org/04g3t6s80","country_code":"NO","type":"government","lineage":["https://openalex.org/I1332882736"]}],"countries":["NO"],"is_corresponding":false,"raw_author_name":"Wijnand Eduard","raw_affiliation_strings":["National Institute for Occupational Health, PB8149 Dep., 0033 Oslo, Norway"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"National Institute for Occupational Health, PB8149 Dep., 0033 Oslo, Norway","institution_ids":["https://openalex.org/I1332882736"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5072904054","display_name":"Erik Bye","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I1332882736","display_name":"National Institute of Occupational Health","ror":"https://ror.org/04g3t6s80","country_code":"NO","type":"government","lineage":["https://openalex.org/I1332882736"]}],"countries":["NO"],"is_corresponding":false,"raw_author_name":"Erik Bye","raw_affiliation_strings":["National Institute for Occupational Health, PB8149 Dep., 0033 Oslo, Norway"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"National Institute for Occupational Health, PB8149 Dep., 0033 Oslo, Norway","institution_ids":["https://openalex.org/I1332882736"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5112793018","display_name":"Kari Kulvik Heldal","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I1332882736","display_name":"National Institute of Occupational Health","ror":"https://ror.org/04g3t6s80","country_code":"NO","type":"government","lineage":["https://openalex.org/I1332882736"]}],"countries":["NO"],"is_corresponding":false,"raw_author_name":"Kari Heldal","raw_affiliation_strings":["National Institute for Occupational Health, PB8149 Dep., 0033 Oslo, Norway"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"National Institute for Occupational Health, PB8149 Dep., 0033 Oslo, Norway","institution_ids":["https://openalex.org/I1332882736"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I1332882736"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":16,"citation_normalized_percentile":{"value":0.2572759,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":88,"max":96},"biblio":{"volume":"61","issue":"1","first_page":"107","last_page":"110"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11821","display_name":"Odor and Emission Control Technologies","score":0.7602999806404114,"subfield":{"id":"https://openalex.org/subfields/1508","display_name":"Process Chemistry and Technology"},"field":{"id":"https://openalex.org/fields/15","display_name":"Chemical Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11821","display_name":"Odor and Emission Control Technologies","score":0.7602999806404114,"subfield":{"id":"https://openalex.org/subfields/1508","display_name":"Process Chemistry and Technology"},"field":{"id":"https://openalex.org/fields/15","display_name":"Chemical Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14091","display_name":"Industrial and Mining Safety","score":0.06589999794960022,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13315","display_name":"Occupational Health and Safety in Workplaces","score":0.05389999970793724,"subfield":{"id":"https://openalex.org/subfields/3609","display_name":"Occupational Therapy"},"field":{"id":"https://openalex.org/fields/36","display_name":"Health Professions"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/hydrogen-sulfide","display_name":"hydrogen sulfide","score":1.0},{"id":"https://openalex.org/keywords/peak-concentration","display_name":"peak concentration","score":0.7570000290870667},{"id":"https://openalex.org/keywords/wastewater-treatment-plants","display_name":"wastewater treatment plants","score":0.7829999923706055},{"id":"https://openalex.org/keywords/occupational-exposure","display_name":"occupational exposure","score":0.6209999918937683},{"id":"https://openalex.org/keywords/offensive-odor","display_name":"offensive odor","score":0.6629999876022339},{"id":"https://openalex.org/keywords/continuous-monitoring","display_name":"continuous monitoring","score":0.4569999873638153},{"id":"https://openalex.org/keywords/remedial-measures","display_name":"remedial measures","score":0.49399998784065247}],"concepts":[{"id":"https://openalex.org/C2780564542","wikidata":"https://www.wikidata.org/wiki/Q170591","display_name":"Hydrogen sulfide","level":3,"score":0.923464834690094},{"id":"https://openalex.org/C2780596425","wikidata":"https://www.wikidata.org/wiki/Q221205","display_name":"Sulfide","level":2,"score":0.5726714134216309},{"id":"https://openalex.org/C4725764","wikidata":"https://www.wikidata.org/wiki/Q844704","display_name":"Extraction (chemistry)","level":2,"score":0.5528348684310913},{"id":"https://openalex.org/C22507642","wikidata":"https://www.wikidata.org/wiki/Q1069369","display_name":"Hazardous waste","level":2,"score":0.5177513957023621},{"id":"https://openalex.org/C58790150","wikidata":"https://www.wikidata.org/wiki/Q10966166","display_name":"Sewage","level":2,"score":0.5147602558135986},{"id":"https://openalex.org/C512968161","wikidata":"https://www.wikidata.org/wiki/Q556","display_name":"Hydrogen","level":2,"score":0.5064789056777954},{"id":"https://openalex.org/C185592680","wikidata":"https://www.wikidata.org/wiki/Q2329","display_name":"Chemistry","level":0,"score":0.49903106689453125},{"id":"https://openalex.org/C107872376","wikidata":"https://www.wikidata.org/wiki/Q321355","display_name":"Environmental chemistry","level":1,"score":0.4903864860534668},{"id":"https://openalex.org/C5140985","wikidata":"https://www.wikidata.org/wiki/Q483866","display_name":"Anaerobic exercise","level":2,"score":0.43321534991264343},{"id":"https://openalex.org/C200457457","wikidata":"https://www.wikidata.org/wiki/Q584049","display_name":"Ventilation (architecture)","level":2,"score":0.4282303750514984},{"id":"https://openalex.org/C65440619","wikidata":"https://www.wikidata.org/wiki/Q177974","display_name":"Atmosphere (unit)","level":2,"score":0.42196860909461975},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.3388362526893616},{"id":"https://openalex.org/C548081761","wikidata":"https://www.wikidata.org/wiki/Q180388","display_name":"Waste management","level":1,"score":0.3132985234260559},{"id":"https://openalex.org/C87717796","wikidata":"https://www.wikidata.org/wiki/Q146326","display_name":"Environmental engineering","level":1,"score":0.27312999963760376},{"id":"https://openalex.org/C518881349","wikidata":"https://www.wikidata.org/wiki/Q682","display_name":"Sulfur","level":2,"score":0.2120944857597351},{"id":"https://openalex.org/C43617362","wikidata":"https://www.wikidata.org/wiki/Q170050","display_name":"Chromatography","level":1,"score":0.15574979782104492},{"id":"https://openalex.org/C86803240","wikidata":"https://www.wikidata.org/wiki/Q420","display_name":"Biology","level":0,"score":0.1479445993900299},{"id":"https://openalex.org/C153294291","wikidata":"https://www.wikidata.org/wiki/Q25261","display_name":"Meteorology","level":1,"score":0.07625356316566467},{"id":"https://openalex.org/C42407357","wikidata":"https://www.wikidata.org/wiki/Q521","display_name":"Physiology","level":1,"score":0.07140129804611206},{"id":"https://openalex.org/C178790620","wikidata":"https://www.wikidata.org/wiki/Q11351","display_name":"Organic chemistry","level":1,"score":0.06949511170387268},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0}],"mesh":[{"descriptor_ui":"D000395","descriptor_name":"Air Pollutants, Occupational","qualifier_ui":"Q000032","qualifier_name":"analysis","is_major_topic":true},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006862","descriptor_name":"Hydrogen Sulfide","qualifier_ui":"Q000032","qualifier_name":"analysis","is_major_topic":true},{"descriptor_ui":"D012722","descriptor_name":"Sewage","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D016273","descriptor_name":"Occupational Exposure","qualifier_ui":"Q000517","qualifier_name":"prevention & control","is_major_topic":true},{"descriptor_ui":"D017751","descriptor_name":"Safety Management","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":true},{"descriptor_ui":"D018505","descriptor_name":"Waste Management","qualifier_ui":"Q000592","qualifier_name":"standards","is_major_topic":true}],"locations_count":2,"locations":[{"id":"doi:10.1080/15298660008984523","doi":"https://doi.org/10.1080/15298660008984523","is_oa":false,"landing_page_url":"https://doi.org/10.1080/15298660008984523","pdf_url":null,"source":{"id":"https://openalex.org/S4210175721","display_name":"AIHAJ - American Industrial Hygiene Association","issn_l":"1529-8663","issn":["1529-8663","2163-3711"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core"],"host_organization":"https://openalex.org/P4310320547","host_organization_name":"Taylor & Francis","host_organization_lineage":["https://openalex.org/P4310320547","https://openalex.org/P4310320449"],"host_organization_lineage_names":["Taylor & Francis","Informa"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"AIHAJ - American Industrial Hygiene Association","raw_type":"journal-article"},{"id":"pmid:10772623","doi":null,"is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/10772623","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"AIHAJ : a journal for the science of occupational and environmental health and safety","raw_type":"Journal Article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.6618000268936157,"display_name":"Clean water and sanitation","id":"https://metadata.un.org/sdg/6"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W4390676514","https://openalex.org/W4296777455","https://openalex.org/W2792063110","https://openalex.org/W2467756081","https://openalex.org/W4205638036","https://openalex.org/W2002138997","https://openalex.org/W7131246897","https://openalex.org/W2087811540","https://openalex.org/W2090638780","https://openalex.org/W2119281226"],"abstract_inverted_index":{"The":[0,137],"concentration":[1,87],"of":[2,8,56,60,77,151],"hydrogen":[3,85,106],"sulfide":[4,86,107],"in":[5,13,115,155],"the":[6,25,57,73,78,84,116,149],"atmosphere":[7],"a":[9,67],"sewage":[10,117],"purification":[11],"plant":[12,65],"Norway":[14],"was":[15,70,92],"studied.":[16],"Continuous":[17],"measurements":[18],"over":[19,36],"several":[20],"3-week":[21],"periods":[22],"showed":[23],"that":[24],"concentrations":[26,35,126],"generally":[27],"were":[28,39],"lower":[29],"than":[30,100],"2":[31,101],"ppm,":[32],"but":[33],"peak":[34,47],"100":[37,96],"ppm":[38,97],"discovered.":[40],"Rapid":[41],"onset":[42],"and":[43,108,147],"decline":[44],"characterized":[45],"these":[46,61],"concentrations,":[48],"which":[49],"occurred":[50],"at":[51],"regular":[52],"intervals.":[53],"Through":[54,80],"evaluation":[55],"time":[58],"pattern":[59],"peaks":[62],"compared":[63],"with":[64,89,133,157],"operations,":[66],"specific":[68],"process":[69],"identified":[71],"as":[72],"likely":[74],"causative":[75],"factor":[76],"spikes.":[79],"simple":[81],"remedial":[82],"actions":[83],"associated":[88],"this":[90],"activity":[91],"reduced":[93,143],"from":[94,112],"above":[95],"to":[98,105],"less":[99],"ppm.":[102],"Olfactory":[103],"fatigue":[104],"strong":[109],"offensive":[110],"odors":[111],"other":[113],"compounds":[114],"makes":[118],"smell":[119],"ineffective":[120],"for":[121,139],"signaling":[122],"high":[123],"concentrations.":[124],"Peak":[125],"may":[127,141],"therefore":[128],"pass":[129],"unnoticed":[130],"unless":[131],"detected":[132],"continuous":[134],"measuring":[135],"equipment.":[136],"risk":[138],"exposure":[140],"be":[142],"by":[144],"enclosing":[145],"processes":[146],"through":[148],"use":[150],"spot":[152],"extraction":[153],"ventilation":[154],"areas":[156],"compacted":[158],"anaerobic":[159],"waste":[160],"material.":[161]},"counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2025,"cited_by_count":1},{"year":2021,"cited_by_count":1},{"year":2018,"cited_by_count":1},{"year":2015,"cited_by_count":1},{"year":2014,"cited_by_count":1},{"year":2013,"cited_by_count":1}],"updated_date":"2026-10-31T12:09:11.096373","created_date":"2016-06-24T00:00:00"}
