{"id":"https://openalex.org/W2015342575","doi":"https://doi.org/10.1061/(asce)cc.1943-5614.0000338","title":"Fire Endurance and Residual Strength of Insulated Concrete Beams Strengthened with Near-Surface Mounted Reinforcement","display_name":"Fire Endurance and Residual Strength of Insulated Concrete Beams Strengthened with Near-Surface Mounted Reinforcement","alternate_titles":[],"publication_year":2012,"publication_date":"2012-10-13","ids":{"openalex":"https://openalex.org/W2015342575","doi":"https://doi.org/10.1061/(asce)cc.1943-5614.0000338","mag":"2015342575"},"language":"en","primary_location":{"id":"doi:10.1061/(asce)cc.1943-5614.0000338","doi":"https://doi.org/10.1061/(asce)cc.1943-5614.0000338","is_oa":true,"landing_page_url":"https://doi.org/10.1061/(asce)cc.1943-5614.0000338","pdf_url":"https://ascelibrary.org/doi/pdf/10.1061/%28ASCE%29CC.1943-5614.0000338","source":{"id":"https://openalex.org/S33209994","display_name":"Journal of Composites for Construction","issn_l":"1090-0268","issn":["1090-0268","1943-5614"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-a","jufo-2","norway-1","poland-140","russia-white-list-1"],"host_organization":"https://openalex.org/P4310315747","host_organization_name":"American Society of Civil Engineers","host_organization_lineage":["https://openalex.org/P4310315747"],"host_organization_lineage_names":["American Society of Civil Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Journal of Composites for Construction","raw_type":"journal-article"},"parent_works":[],"lineage":["https://openalex.org/W2015342575"],"child_works_count":0,"pull_notice_works":[],"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"bronze","oa_url":"https://ascelibrary.org/doi/pdf/10.1061/%28ASCE%29CC.1943-5614.0000338","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5112198657","display_name":"Aniello Palmieri","type":null,"orcid":null,"observed_orcids":[]},"acted_on_behalf_of":[],"institutions":[{"id":"https://openalex.org/I32597200","display_name":"Ghent University","ror":"https://ror.org/00cv9y106","country_code":"BE","type":"education","lineage":["https://openalex.org/I32597200"]}],"countries":["BE"],"is_corresponding":true,"contributor_roles":[],"raw_author_name":"Aniello Palmieri","raw_affiliation_strings":["Ph.D. Student, Magnel Laboratory for Concrete Research, Dept. of Structural Engineering, Ghent Univ., 9052 Gent, Belgium (corresponding author)"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Ph.D. Student, Magnel Laboratory for Concrete Research, Dept. of Structural Engineering, Ghent Univ., 9052 Gent, Belgium (corresponding author)","institution_ids":["https://openalex.org/I32597200"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5075009727","display_name":"Stijn Matthys","type":null,"orcid":"https://orcid.org/0000-0002-9588-8561","observed_orcids":["https://orcid.org/0000-0002-9588-8561"]},"acted_on_behalf_of":[],"institutions":[{"id":"https://openalex.org/I32597200","display_name":"Ghent University","ror":"https://ror.org/00cv9y106","country_code":"BE","type":"education","lineage":["https://openalex.org/I32597200"]}],"countries":["BE"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"Stijn Matthys","raw_affiliation_strings":["Professor, Magnel Laboratory for Concrete Research, Dept. of Structural Engineering, Ghent Univ., 9052 Gent, Belgium; and Technology Development Manager, Ghent Univ., 9052 Gent, Belgium","Technology Development Manager, Ghent Univ., 9052 Gent, Belgium. E-mail:"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Professor, Magnel Laboratory for Concrete Research, Dept. of Structural Engineering, Ghent Univ., 9052 Gent, Belgium; and Technology Development Manager, Ghent Univ., 9052 Gent, Belgium","institution_ids":["https://openalex.org/I32597200"]},{"raw_affiliation_string":"Technology Development Manager, Ghent Univ., 9052 Gent, Belgium. E-mail:","institution_ids":["https://openalex.org/I32597200"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5113796805","display_name":"Luc R. Taerwe","type":null,"orcid":null,"observed_orcids":[]},"acted_on_behalf_of":[],"institutions":[{"id":"https://openalex.org/I32597200","display_name":"Ghent University","ror":"https://ror.org/00cv9y106","country_code":"BE","type":"education","lineage":["https://openalex.org/I32597200"]}],"countries":["BE"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"Luc Taerwe","raw_affiliation_strings":["Professor, Magnel Laboratory for Concrete Research, Dept. of Structural Engineering, Ghent Univ., 9052 Gent, Belgium; Head, Dept. of Structural Engineering, Ghent Univ., 9052 Gent, Belgium; and Dean, Faculty of Engineering, Ghent Univ., 9052 Gent, Belgium","Dean, Faculty of Engineering, Ghent Univ., 9052 Gent, Belgium. E-mail:","Head, Dept. of Structural Engineering, Ghent Univ., 9052 Gent, Belgium"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Professor, Magnel Laboratory for Concrete Research, Dept. of Structural Engineering, Ghent Univ., 9052 Gent, Belgium; Head, Dept. of Structural Engineering, Ghent Univ., 9052 Gent, Belgium; and Dean, Faculty of Engineering, Ghent Univ., 9052 Gent, Belgium","institution_ids":["https://openalex.org/I32597200"]},{"raw_affiliation_string":"Dean, Faculty of Engineering, Ghent Univ., 9052 Gent, Belgium. E-mail:","institution_ids":["https://openalex.org/I32597200"]},{"raw_affiliation_string":"Head, Dept. of Structural Engineering, Ghent Univ., 9052 Gent, Belgium","institution_ids":["https://openalex.org/I32597200"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":["https://openalex.org/A5112198657"],"corresponding_institution_ids":["https://openalex.org/I32597200"],"apc_list":null,"apc_paid":null,"fwci":4.097,"has_fulltext":true,"cited_by_count":47,"reviewed_by_count":0,"citation_normalized_percentile":{"value":0.92753389,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":86,"max":98},"biblio":{"volume":"17","issue":"4","first_page":"454","last_page":"462"},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10479","display_name":"Structural Behavior of Reinforced Concrete","score":0.4966000020503998,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10479","display_name":"Structural Behavior of Reinforced Concrete","score":0.4966000020503998,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12102","display_name":"Fire effects on concrete materials","score":0.492900013923645,"subfield":{"id":"https://openalex.org/subfields/2205","display_name":"Civil and Structural Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11352","display_name":"Masonry and Concrete Structural Analysis","score":0.00279999990016222,"subfield":{"id":"https://openalex.org/subfields/2205","display_name":"Civil and Structural Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/fire-endurance","display_name":"fire endurance","score":0.7609999775886536},{"id":"https://openalex.org/keywords/residual-strength","display_name":"residual strength","score":0.8899999856948853},{"id":"https://openalex.org/keywords/near-surface-mounted-reinforcement","display_name":"near-surface mounted reinforcement","score":0.9629999995231628},{"id":"https://openalex.org/keywords/frp-strengthening","display_name":"FRP strengthening","score":0.8610000014305115},{"id":"https://openalex.org/keywords/fire-resistance","display_name":"fire resistance","score":0.6269999742507935},{"id":"https://openalex.org/keywords/full-scale-beam-testing","display_name":"full-scale beam testing","score":0.546999990940094}],"concepts":[{"id":"https://openalex.org/C76344452","wikidata":"https://www.wikidata.org/wiki/Q263125","display_name":"Fibre-reinforced plastic","level":2,"score":0.9419509172439575},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.7636904716491699},{"id":"https://openalex.org/C168834538","wikidata":"https://www.wikidata.org/wiki/Q3705329","display_name":"Beam (structure)","level":2,"score":0.6749480962753296},{"id":"https://openalex.org/C20965850","wikidata":"https://www.wikidata.org/wiki/Q7315516","display_name":"Residual strength","level":2,"score":0.6187334060668945},{"id":"https://openalex.org/C66938386","wikidata":"https://www.wikidata.org/wiki/Q633538","display_name":"Structural engineering","level":1,"score":0.612658679485321},{"id":"https://openalex.org/C159985019","wikidata":"https://www.wikidata.org/wiki/Q181790","display_name":"Composite material","level":1,"score":0.5835229754447937},{"id":"https://openalex.org/C2987912017","wikidata":"https://www.wikidata.org/wiki/Q27787358","display_name":"Fire resistance","level":2,"score":0.46170714497566223},{"id":"https://openalex.org/C67203356","wikidata":"https://www.wikidata.org/wiki/Q1321905","display_name":"Reinforcement","level":2,"score":0.4405193328857422},{"id":"https://openalex.org/C68928338","wikidata":"https://www.wikidata.org/wiki/Q131790","display_name":"Adhesive","level":3,"score":0.4391842484474182},{"id":"https://openalex.org/C2779227376","wikidata":"https://www.wikidata.org/wiki/Q6505497","display_name":"Layer (electronics)","level":2,"score":0.14032411575317383},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.11985036730766296}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1061/(asce)cc.1943-5614.0000338","doi":"https://doi.org/10.1061/(asce)cc.1943-5614.0000338","is_oa":true,"landing_page_url":"https://doi.org/10.1061/(asce)cc.1943-5614.0000338","pdf_url":"https://ascelibrary.org/doi/pdf/10.1061/%28ASCE%29CC.1943-5614.0000338","source":{"id":"https://openalex.org/S33209994","display_name":"Journal of Composites for Construction","issn_l":"1090-0268","issn":["1090-0268","1943-5614"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-a","jufo-2","norway-1","poland-140","russia-white-list-1"],"host_organization":"https://openalex.org/P4310315747","host_organization_name":"American Society of Civil Engineers","host_organization_lineage":["https://openalex.org/P4310315747"],"host_organization_lineage_names":["American Society of Civil Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Journal of Composites for Construction","raw_type":"journal-article"},{"id":"pmh:oai:archive.ugent.be:3238162","doi":null,"is_oa":true,"landing_page_url":"http://hdl.handle.net/1854/LU-3238162","pdf_url":"https://biblio.ugent.be/publication/3238162/file/3238167.pdf","source":{"id":"https://openalex.org/S4306400478","display_name":"Ghent University Academic Bibliography (Ghent University)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I32597200","host_organization_name":"Ghent University","host_organization_lineage":["https://openalex.org/I32597200"],"host_organization_lineage_names":[],"type":"repository"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"ISSN: 1090-0268","raw_type":"info:eu-repo/semantics/article"}],"best_oa_location":{"id":"doi:10.1061/(asce)cc.1943-5614.0000338","doi":"https://doi.org/10.1061/(asce)cc.1943-5614.0000338","is_oa":true,"landing_page_url":"https://doi.org/10.1061/(asce)cc.1943-5614.0000338","pdf_url":"https://ascelibrary.org/doi/pdf/10.1061/%28ASCE%29CC.1943-5614.0000338","source":{"id":"https://openalex.org/S33209994","display_name":"Journal of Composites for Construction","issn_l":"1090-0268","issn":["1090-0268","1943-5614"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-a","jufo-2","norway-1","poland-140","russia-white-list-1"],"host_organization":"https://openalex.org/P4310315747","host_organization_name":"American Society of Civil Engineers","host_organization_lineage":["https://openalex.org/P4310315747"],"host_organization_lineage_names":["American Society of Civil Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Journal of Composites for Construction","raw_type":"journal-article"},"sustainable_development_goals":[],"study_designs":[],"awards":[],"funders":[{"id":"https://openalex.org/F4320321730","display_name":"Fonds Wetenschappelijk Onderzoek","ror":"https://ror.org/03qtxy027"}],"has_content":{"pdf":true,"grobid_xml":true},"content_urls":{"pdf":"https://content.openalex.org/works/W2015342575.pdf","grobid_xml":"https://content.openalex.org/works/W2015342575.grobid-xml"},"referenced_works_count":28,"referenced_works":["https://openalex.org/W1497873341","https://openalex.org/W1591560645","https://openalex.org/W1949719639","https://openalex.org/W1963794989","https://openalex.org/W1967816155","https://openalex.org/W1970859321","https://openalex.org/W1997065837","https://openalex.org/W1998034205","https://openalex.org/W2003634404","https://openalex.org/W2010595593","https://openalex.org/W2020736884","https://openalex.org/W2026934458","https://openalex.org/W2028714678","https://openalex.org/W2029499281","https://openalex.org/W2032658817","https://openalex.org/W2035068541","https://openalex.org/W2041115421","https://openalex.org/W2137857930","https://openalex.org/W2145143220","https://openalex.org/W2147459408","https://openalex.org/W2162803908","https://openalex.org/W2185779093","https://openalex.org/W2291139898","https://openalex.org/W2295399634","https://openalex.org/W2300389190","https://openalex.org/W2329649220","https://openalex.org/W2737180026","https://openalex.org/W2963584185"],"related_works":["https://openalex.org/W1997065837","https://openalex.org/W2301056596","https://openalex.org/W2489544982","https://openalex.org/W2111442649","https://openalex.org/W2245439250","https://openalex.org/W2079745126","https://openalex.org/W1973906351","https://openalex.org/W3146952630","https://openalex.org/W3204422493","https://openalex.org/W2300389190"],"abstract_inverted_index":{"The":[0],"comparatively":[1],"weak":[2],"performance":[3,59,124],"of":[4,20,34,42,60,73,84,105,125,129,183],"fiber-reinforced":[5],"polymer":[6],"(FRP)":[7],"strengthened":[8,86],"members":[9],"under":[10,46,163],"fire":[11,27,47,103,110,164],"exposure":[12],"is":[13,29,138,165],"a":[14,35,101,119,173],"primary":[15],"factor":[16],"hindering":[17],"the":[18,40,58,76,81,85,95,122,135,142,151,158,168],"application":[19],"FRP":[21,43,159],"strengthening":[22,44],"in":[23,25,154,179],"buildings":[24],"which":[26],"risk":[28],"not":[30],"negligible.":[31],"As":[32],"part":[33,175],"larger":[36],"ongoing":[37],"study":[38,120,131],"investigating":[39],"behavior":[41],"systems":[45],"exposure,":[48],"an":[49],"investigation":[50],"was":[51],"set":[52],"up":[53],"to":[54,70,80,140,177],"examine":[55],"and":[56,167],"document":[57],"six":[61],"full-scale":[62],"near-surface":[63],"mounted":[64],"(NSM)":[65],"FRP-reinforced":[66],"concrete":[67,160],"beams":[68,98],"exposed":[69],"1":[71,106],"h":[72,107],"fire.":[74],"All":[75],"specimens":[77],"were":[78],"preloaded":[79],"service":[82],"load":[83],"member.":[87],"Tests":[88],"results":[89],"indicated":[90],"that,":[91],"if":[92,134],"appropriately":[93],"insulated,":[94],"NSM":[96],"FRP-strengthened":[97,169],"can":[99,171],"achieve":[100],"satisfactory":[102],"endurance":[104],"as":[108],"per":[109],"resistance":[111],"test":[112,156,181],"specifications.":[113],"Moreover,":[114],"this":[115,130,155,180],"paper":[116],"also":[117],"presents":[118],"on":[121],"residual":[123],"fire-tested":[126],"beams.":[127],"Results":[128],"suggest":[132],"that":[133],"insulation":[136],"system":[137],"able":[139],"maintain":[141],"adhesive":[143],"temperature":[144],"at":[145],"relatively":[146],"low":[147],"value":[148],"(tadhesive\u22641.6tg":[149],"for":[150],"beam":[152,170],"configuration":[153],"program),":[157],"bond":[161],"degradation":[162],"limited,":[166],"retain":[172],"large":[174],"(up":[176],"92%":[178],"program)":[182],"its":[184],"original":[185],"strength.":[186]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W2015342575","counts_by_year":[{"year":2026,"cited_by_count":2},{"year":2025,"cited_by_count":1},{"year":2024,"cited_by_count":3},{"year":2023,"cited_by_count":2},{"year":2022,"cited_by_count":4},{"year":2021,"cited_by_count":5},{"year":2020,"cited_by_count":3},{"year":2019,"cited_by_count":4},{"year":2018,"cited_by_count":6},{"year":2017,"cited_by_count":3},{"year":2016,"cited_by_count":6},{"year":2015,"cited_by_count":5},{"year":2014,"cited_by_count":2},{"year":2013,"cited_by_count":1}],"updated_date":"2026-11-21T10:27:49.728292","created_date":"2016-06-24T00:00:00"}
