{"id":"https://openalex.org/W2014917409","doi":"https://doi.org/10.1109/tpwrd.2014.2327074","title":"Analysis of Temporary Overvoltages During Open-Phase Faults in Distribution Networks With Resonant Grounding","display_name":"Analysis of Temporary Overvoltages During Open-Phase Faults in Distribution Networks With Resonant Grounding","publication_year":2014,"publication_date":"2014-06-19","ids":{"openalex":"https://openalex.org/W2014917409","doi":"https://doi.org/10.1109/tpwrd.2014.2327074","mag":"2014917409"},"language":"en","primary_location":{"id":"doi:10.1109/tpwrd.2014.2327074","doi":"https://doi.org/10.1109/tpwrd.2014.2327074","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tpwrd.2014.2327074","pdf_url":null,"source":{"id":"https://openalex.org/S203966947","display_name":"IEEE Transactions on Power Delivery","issn_l":"0885-8977","issn":["0885-8977","1937-4208"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["anvur-scientific","cwts-core","dongbi-b","jufo-2","norway-2","poland-140","russia-white-list-1"],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Power Delivery","raw_type":"journal-article"},"volume":null,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5109384059","display_name":"A. Kalyuzhny","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I80687555","display_name":"Israel Electric (Israel)","ror":"https://ror.org/01p8dnv11","country_code":"IL","type":"company","lineage":["https://openalex.org/I80687555"]}],"countries":["IL"],"is_corresponding":true,"raw_author_name":"A. Kalyuzhny","raw_affiliation_strings":["Planning, Development & Technology Division, The Israel Electric Corporation LTD, Haifa, Israel"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Planning, Development & Technology Division, The Israel Electric Corporation LTD, Haifa, Israel","institution_ids":["https://openalex.org/I80687555"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":["https://openalex.org/A5109384059"],"corresponding_institution_ids":["https://openalex.org/I80687555"],"apc_list":{"value":2645,"currency":"USD","value_usd":2645},"apc_paid":null,"fwci":1.7599,"has_fulltext":false,"cited_by_count":48,"citation_normalized_percentile":{"value":0.85839767,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":88,"max":99},"biblio":{"volume":"30","issue":"1","first_page":"420","last_page":"427"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.5112000107765198,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.5112000107765198,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10573","display_name":"Power Quality and Harmonics","score":0.39500001072883606,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.036400001496076584,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/temporary-overvoltage","display_name":"temporary overvoltage","score":0.9929999709129333},{"id":"https://openalex.org/keywords/open-phase-fault","display_name":"open-phase fault","score":0.9919999837875366},{"id":"https://openalex.org/keywords/resonant-grounding","display_name":"resonant grounding","score":0.9139999747276306},{"id":"https://openalex.org/keywords/petersen-coil","display_name":"Petersen coil","score":0.8759999871253967},{"id":"https://openalex.org/keywords/distribution-networks","display_name":"distribution networks","score":0.8889999985694885},{"id":"https://openalex.org/keywords/neutral-voltage","display_name":"neutral voltage","score":0.9380000233650208},{"id":"https://openalex.org/keywords/damping-factor","display_name":"damping factor","score":0.6909999847412109},{"id":"https://openalex.org/keywords/overvoltage-suppression","display_name":"overvoltage suppression","score":0.6769999861717224}],"concepts":[{"id":"https://openalex.org/C168993435","wikidata":"https://www.wikidata.org/wiki/Q6501125","display_name":"Ground","level":2,"score":0.7905206680297852},{"id":"https://openalex.org/C15703209","wikidata":"https://www.wikidata.org/wiki/Q333883","display_name":"Overvoltage","level":3,"score":0.6996838450431824},{"id":"https://openalex.org/C30403606","wikidata":"https://www.wikidata.org/wiki/Q2981904","display_name":"Electromagnetic coil","level":2,"score":0.6345654129981995},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.6008706092834473},{"id":"https://openalex.org/C66322947","wikidata":"https://www.wikidata.org/wiki/Q11658","display_name":"Transformer","level":3,"score":0.5593655109405518},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.5161260366439819},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.5108701586723328},{"id":"https://openalex.org/C101382669","wikidata":"https://www.wikidata.org/wiki/Q1616769","display_name":"Ferroresonance in electricity networks","level":4,"score":0.42676153779029846}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tpwrd.2014.2327074","doi":"https://doi.org/10.1109/tpwrd.2014.2327074","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tpwrd.2014.2327074","pdf_url":null,"source":{"id":"https://openalex.org/S203966947","display_name":"IEEE Transactions on Power Delivery","issn_l":"0885-8977","issn":["0885-8977","1937-4208"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["anvur-scientific","cwts-core","dongbi-b","jufo-2","norway-2","poland-140","russia-white-list-1"],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Power Delivery","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/9","score":0.5378999710083008,"display_name":"Industry, innovation and infrastructure"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":17,"referenced_works":["https://openalex.org/W590351265","https://openalex.org/W1967595484","https://openalex.org/W1971835890","https://openalex.org/W2016556407","https://openalex.org/W2030035095","https://openalex.org/W2030829191","https://openalex.org/W2042029803","https://openalex.org/W2047991837","https://openalex.org/W2056042489","https://openalex.org/W2060078910","https://openalex.org/W2097544686","https://openalex.org/W2105803755","https://openalex.org/W2152242414","https://openalex.org/W2211752624","https://openalex.org/W2602330298","https://openalex.org/W3048564922","https://openalex.org/W3216876513"],"related_works":["https://openalex.org/W2171139767","https://openalex.org/W4387039408","https://openalex.org/W1971835890","https://openalex.org/W1998111543","https://openalex.org/W3216560592","https://openalex.org/W2527522525","https://openalex.org/W2121745721","https://openalex.org/W2017537598","https://openalex.org/W4252170439","https://openalex.org/W2347680293"],"abstract_inverted_index":{"This":[0],"paper":[1],"analyzes":[2],"the":[3,24,28,32,40,49,69,80,83,89,96,104,107,114,122,128,132,138],"temporary":[4,41],"overvoltages":[5,21,29,42,59],"(TOVs)":[6],"that":[7],"may":[8],"appear":[9],"in":[10,13,68,135],"open-phase":[11,25,66],"states":[12,26],"distribution":[14,73,86],"networks":[15],"with":[16,127],"resonant":[17],"grounding.":[18],"The":[19,35,45,54,62,77],"high":[20],"recorded":[22],"during":[23],"exceed":[27],"corresponding":[30],"to":[31,137],"existing":[33],"theory.":[34],"detailed":[36],"analytical":[37],"study":[38,64],"of":[39,48,79,85,106,116,121,131],"is":[43,52,75,125],"performed.":[44],"closed-form":[46],"expression":[47],"neutral":[50],"voltage":[51,108],"derived.":[53],"conditions":[55],"for":[56,65,113],"maximum":[57],"phase-to-earth":[58],"are":[60,110,118],"obtained.":[61],"case":[63],"faults":[67],"33-kV":[70],"resonantly":[71],"grounded":[72],"network":[74],"described.":[76],"dependence":[78],"TOVs":[81,117],"on":[82,88,92,95,103],"number":[84],"feeders,":[87],"feeder":[90],"loading,":[91],"detuning":[93],"factor,":[94,99],"additional":[97],"damping":[98],"as":[100,102],"well":[101],"saturation":[105],"transformers":[109],"analyzed.":[111],"Remedies":[112],"reduction":[115],"considered.":[119],"Detuning":[120],"Petersen":[123,139],"coil":[124],"compared":[126],"permanent":[129],"connection":[130],"wattmetric":[133],"resistance":[134],"parallel":[136],"coil.":[140]},"counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2025,"cited_by_count":7},{"year":2024,"cited_by_count":1},{"year":2023,"cited_by_count":6},{"year":2022,"cited_by_count":4},{"year":2021,"cited_by_count":6},{"year":2020,"cited_by_count":7},{"year":2019,"cited_by_count":8},{"year":2018,"cited_by_count":2},{"year":2017,"cited_by_count":2},{"year":2016,"cited_by_count":4}],"updated_date":"2026-09-27T08:07:27.782135","created_date":"2016-06-24T00:00:00"}
