{"id":"https://openalex.org/W2014258745","doi":"https://doi.org/10.3139/124.110332","title":"On-site power system reliability of a nuclear power plant after the earthquake","display_name":"On-site power system reliability of a nuclear power plant after the earthquake","publication_year":2013,"publication_date":"2013-05-03","ids":{"openalex":"https://openalex.org/W2014258745","doi":"https://doi.org/10.3139/124.110332","mag":"2014258745"},"language":"en","primary_location":{"id":"doi:10.3139/124.110332","doi":"https://doi.org/10.3139/124.110332","is_oa":false,"landing_page_url":"https://doi.org/10.3139/124.110332","pdf_url":null,"source":{"id":"https://openalex.org/S191522244","display_name":"Kerntechnik","issn_l":"0932-3902","issn":["0932-3902","2195-8580"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-d","jufo-1","norway-1","poland-40","russia-white-list-4"],"host_organization":"https://openalex.org/P4310313990","host_organization_name":"De Gruyter","host_organization_lineage":["https://openalex.org/P4310313990"],"host_organization_lineage_names":["De Gruyter"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Kerntechnik","raw_type":"journal-article"},"volume":null,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5005400811","display_name":"Andrija Volkanovski","orcid":"https://orcid.org/0000-0002-7777-0893","observed_orcids":["https://orcid.org/0000-0002-7777-0893"]},"institutions":[{"id":"https://openalex.org/I3006985408","display_name":"Jo\u017eef Stefan Institute","ror":"https://ror.org/05060sz93","country_code":"SI","type":"facility","lineage":["https://openalex.org/I3006985408"]}],"countries":["SI"],"is_corresponding":true,"raw_author_name":"A. Volkanovski","raw_affiliation_strings":["Reactor Engineering Division, \u201cJo\u017eef Stefan\u201d Institute, Jamova 39, 1000, Ljubljana, Slovenia, E-mail:"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Reactor Engineering Division, \u201cJo\u017eef Stefan\u201d Institute, Jamova 39, 1000, Ljubljana, Slovenia, E-mail:","institution_ids":["https://openalex.org/I3006985408"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":["https://openalex.org/A5005400811"],"corresponding_institution_ids":["https://openalex.org/I3006985408"],"apc_list":{"value":2400,"currency":"EUR","value_usd":2712},"apc_paid":null,"fwci":4.1977,"has_fulltext":false,"cited_by_count":14,"citation_normalized_percentile":{"value":0.92803253,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":88,"max":97},"biblio":{"volume":"78","issue":"2","first_page":"99","last_page":"112"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11357","display_name":"Risk and Safety Analysis","score":0.44429999589920044,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11357","display_name":"Risk and Safety Analysis","score":0.44429999589920044,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11807","display_name":"Infrastructure Resilience and Vulnerability Analysis","score":0.17550000548362732,"subfield":{"id":"https://openalex.org/subfields/2205","display_name":"Civil and Structural Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11941","display_name":"Power System Reliability and Maintenance","score":0.09870000183582306,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/power-system-reliability","display_name":"power system reliability","score":0.8550000190734863},{"id":"https://openalex.org/keywords/earthquakes","display_name":"earthquakes","score":0.6190000176429749},{"id":"https://openalex.org/keywords/station-blackout","display_name":"station blackout","score":0.640999972820282},{"id":"https://openalex.org/keywords/safe-shutdown-earthquake","display_name":"safe shutdown earthquake","score":0.8809999823570251},{"id":"https://openalex.org/keywords/peak-ground-acceleration","display_name":"peak ground acceleration","score":0.7839999794960022},{"id":"https://openalex.org/keywords/fukushima-daiichi-nuclear-power-plant","display_name":"Fukushima Daiichi Nuclear Power Plant","score":0.8700000047683716}],"concepts":[{"id":"https://openalex.org/C2779979336","wikidata":"https://www.wikidata.org/wiki/Q134447","display_name":"Nuclear power plant","level":2,"score":0.7647924423217773},{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.694466769695282},{"id":"https://openalex.org/C2777693866","wikidata":"https://www.wikidata.org/wiki/Q359099","display_name":"Blackout","level":4,"score":0.6831912398338318},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.6463706493377686},{"id":"https://openalex.org/C513653683","wikidata":"https://www.wikidata.org/wiki/Q12739","display_name":"Nuclear power","level":2,"score":0.6125640869140625},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.49724605679512024},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.4361240863800049},{"id":"https://openalex.org/C2780263472","wikidata":"https://www.wikidata.org/wiki/Q331902","display_name":"Shutdown","level":2,"score":0.4195011854171753},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4179237186908722},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.4019172787666321},{"id":"https://openalex.org/C116915560","wikidata":"https://www.wikidata.org/wiki/Q83504","display_name":"Nuclear engineering","level":1,"score":0.3940800428390503},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2404935359954834},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.13275423645973206},{"id":"https://openalex.org/C185544564","wikidata":"https://www.wikidata.org/wiki/Q81197","display_name":"Nuclear physics","level":1,"score":0.07533785700798035},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.3139/124.110332","doi":"https://doi.org/10.3139/124.110332","is_oa":false,"landing_page_url":"https://doi.org/10.3139/124.110332","pdf_url":null,"source":{"id":"https://openalex.org/S191522244","display_name":"Kerntechnik","issn_l":"0932-3902","issn":["0932-3902","2195-8580"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-d","jufo-1","norway-1","poland-40","russia-white-list-4"],"host_organization":"https://openalex.org/P4310313990","host_organization_name":"De Gruyter","host_organization_lineage":["https://openalex.org/P4310313990"],"host_organization_lineage_names":["De Gruyter"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Kerntechnik","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","score":0.5690000057220459,"id":"https://metadata.un.org/sdg/7"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":14,"referenced_works":["https://openalex.org/W1502298436","https://openalex.org/W1966330908","https://openalex.org/W2005777289","https://openalex.org/W2007838308","https://openalex.org/W2025223104","https://openalex.org/W2040990812","https://openalex.org/W2075689173","https://openalex.org/W2089377495","https://openalex.org/W2092633340","https://openalex.org/W2092834718","https://openalex.org/W2132449394","https://openalex.org/W2134833517","https://openalex.org/W2153277459","https://openalex.org/W4229994475"],"related_works":["https://openalex.org/W2954705472","https://openalex.org/W7131615551","https://openalex.org/W2399087922","https://openalex.org/W7170467403","https://openalex.org/W2043467507","https://openalex.org/W2029993627","https://openalex.org/W1999543206","https://openalex.org/W172840943","https://openalex.org/W2548015967","https://openalex.org/W3165742416"],"abstract_inverted_index":{"Abstract":[0],"Continuous":[1],"and":[2,67,88,118,125,185],"reliable":[3],"sources":[4],"of":[5,13,15,26,36,50,80,92,103,110,134,136,164,170,182],"electrical":[6,30],"energy":[7,31],"are":[8],"required":[9],"during":[10,64,122],"all":[11],"modes":[12],"operation":[14,66,124],"a":[16,137],"nuclear":[17,38,57,105,158],"power":[18,39,46,58,61,83,96,106,120,140,159],"plant":[19,40,59],"in":[20,86,98,188],"order":[21],"to":[22,32,54,150],"assure":[23],"the":[24,27,33,37,44,56,69,78,81,93,101,104,115,143,151,155,165,171,180,183,189],"safety":[25,34,102],"plant.":[28,107,160],"The":[29,48,74],"systems":[35],"is":[41,53,112,177],"provided":[42],"from":[43],"on-site":[45,60,82],"system.":[47],"objective":[49],"this":[51],"paper":[52],"analyze":[55],"system":[62,84,97,121,141],"reliability":[63,85,111,135],"normal":[65,123],"after":[68,142],"earthquakes":[70],"with":[71,145],"given":[72],"intensity.":[73],"obtained":[75,113],"results":[76,130,181],"show":[77,131],"importance":[79],"general":[87],"battery":[89],"supported":[90],"section":[91],"Class":[94,116,138],"1E":[95,117,139],"particular":[99],"for":[100,114,162,168],"High":[108],"level":[109,133],"Non-1E":[119],"safe":[126],"shutdown":[127],"earthquake.":[128],"Obtained":[129],"high":[132],"earthquake":[144],"peak":[146],"ground":[147],"acceleration":[148],"equal":[149],"one":[152],"measured":[153],"at":[154],"Fukushima":[156],"Daiichi":[157],"Recommendation":[161],"revision":[163],"current":[166,190],"guideline":[167],"assessment":[169],"acceptable":[172],"station":[173],"blackout":[174],"duration":[175],"capability":[176],"recommended":[178],"considering":[179],"analysis":[184],"identified":[186],"deficiencies":[187],"guideline.":[191]},"counts_by_year":[{"year":2025,"cited_by_count":1},{"year":2024,"cited_by_count":2},{"year":2023,"cited_by_count":1},{"year":2022,"cited_by_count":2},{"year":2018,"cited_by_count":3},{"year":2016,"cited_by_count":2},{"year":2015,"cited_by_count":3}],"updated_date":"2026-08-21T09:56:20.448147","created_date":"2016-06-24T00:00:00"}
