{"id":"https://openalex.org/W2012481254","doi":"https://doi.org/10.3801/iafss.fss.11-517","title":"A New Method for Quantifying Fire Growth Rates Using Statistical and Empirical Data \u2013 Applied to Determine the Effect of Arson","display_name":"A New Method for Quantifying Fire Growth Rates Using Statistical and Empirical Data \u2013 Applied to Determine the Effect of Arson","publication_year":2014,"publication_date":"2014-01-01","ids":{"openalex":"https://openalex.org/W2012481254","doi":"https://doi.org/10.3801/iafss.fss.11-517","mag":"2012481254"},"language":"en","primary_location":{"id":"doi:10.3801/iafss.fss.11-517","doi":"https://doi.org/10.3801/iafss.fss.11-517","is_oa":true,"landing_page_url":"https://doi.org/10.3801/iafss.fss.11-517","pdf_url":"http://www.iafss.org/publications/fss/11/517/view/fss_11-517.pdf","source":{"id":"https://openalex.org/S21917004","display_name":"Fire Safety Science","issn_l":"1817-4299","issn":["1817-4299","1817-4302"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","jufo-1","norway-1"],"host_organization":"https://openalex.org/P4323999588","host_organization_name":"International Association of Fire Safety Science","host_organization_lineage":["https://openalex.org/P4323999588"],"host_organization_lineage_names":["International Association of Fire Safety Science"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Fire Safety Science","raw_type":"journal-article"},"volume":null,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"bronze","oa_url":"http://www.iafss.org/publications/fss/11/517/view/fss_11-517.pdf","any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5049335861","display_name":"Martin Nilsson","orcid":"https://orcid.org/0000-0002-7419-6750","observed_orcids":["https://orcid.org/0000-0002-7419-6750"]},"institutions":[{"id":"https://openalex.org/I187531555","display_name":"Lund University","ror":"https://ror.org/012a77v79","country_code":"SE","type":"education","lineage":["https://openalex.org/I187531555"]}],"countries":["SE"],"is_corresponding":false,"raw_author_name":"M. Nilsson","raw_affiliation_strings":["Department of Fire Safety Engineering and Systems Safety Lund University, P.O. Box 118, SE-221 00 Lund, Sweden,"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Fire Safety Engineering and Systems Safety Lund University, P.O. Box 118, SE-221 00 Lund, Sweden,","institution_ids":["https://openalex.org/I187531555"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5079745374","display_name":"Nils Johansson","orcid":"https://orcid.org/0000-0001-9861-936X","observed_orcids":["https://orcid.org/0000-0001-9861-936X"]},"institutions":[{"id":"https://openalex.org/I187531555","display_name":"Lund University","ror":"https://ror.org/012a77v79","country_code":"SE","type":"education","lineage":["https://openalex.org/I187531555"]}],"countries":["SE"],"is_corresponding":false,"raw_author_name":"N. Johansson","raw_affiliation_strings":["Department of Fire Safety Engineering and Systems Safety Lund University , P.O. Box 118 , SE-221 00 Lund , Sweden,","Division of Fire Safety Engineering"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Fire Safety Engineering and Systems Safety Lund University , P.O. Box 118 , SE-221 00 Lund , Sweden,","institution_ids":["https://openalex.org/I187531555"]},{"raw_affiliation_string":"Division of Fire Safety Engineering","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5079485862","display_name":"Patrick Van Hees","orcid":"https://orcid.org/0000-0002-7405-607X","observed_orcids":["https://orcid.org/0000-0002-7405-607X"]},"institutions":[{"id":"https://openalex.org/I187531555","display_name":"Lund University","ror":"https://ror.org/012a77v79","country_code":"SE","type":"education","lineage":["https://openalex.org/I187531555"]}],"countries":["SE"],"is_corresponding":false,"raw_author_name":"P. Van Hees","raw_affiliation_strings":["Department of Fire Safety Engineering and Systems Safety Lund University , P.O. Box 118 , SE-221 00 Lund , Sweden,","Division of Fire Safety Engineering"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Fire Safety Engineering and Systems Safety Lund University , P.O. Box 118 , SE-221 00 Lund , Sweden,","institution_ids":["https://openalex.org/I187531555"]},{"raw_affiliation_string":"Division of Fire Safety Engineering","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I187531555"],"apc_list":null,"apc_paid":null,"fwci":0.7054,"has_fulltext":true,"cited_by_count":9,"citation_normalized_percentile":{"value":0.7478315,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":88,"max":95},"biblio":{"volume":"11","issue":null,"first_page":"517","last_page":"530"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11317","display_name":"Fire dynamics and safety research","score":0.9984999895095825,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11317","display_name":"Fire dynamics and safety research","score":0.9984999895095825,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12102","display_name":"Fire effects on concrete materials","score":0.000699999975040555,"subfield":{"id":"https://openalex.org/subfields/2205","display_name":"Civil and Structural Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12597","display_name":"Fire Detection and Safety Systems","score":9.999999747378752e-05,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/fire-growth-rate","display_name":"fire growth rate","score":0.9929999709129333},{"id":"https://openalex.org/keywords/arson-fires","display_name":"arson fires","score":0.8830000162124634},{"id":"https://openalex.org/keywords/fire-safety-engineering","display_name":"fire safety engineering","score":0.6840000152587891},{"id":"https://openalex.org/keywords/fire-statistics","display_name":"fire statistics","score":0.628000020980835},{"id":"https://openalex.org/keywords/commercial-buildings","display_name":"commercial buildings","score":0.984000027179718}],"concepts":[{"id":"https://openalex.org/C2780309315","wikidata":"https://www.wikidata.org/wiki/Q327541","display_name":"Arson","level":2,"score":0.9933770895004272},{"id":"https://openalex.org/C2989191132","wikidata":"https://www.wikidata.org/wiki/Q2997557","display_name":"Fire safety","level":2,"score":0.4870064854621887},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.4773038625717163},{"id":"https://openalex.org/C77595967","wikidata":"https://www.wikidata.org/wiki/Q3151013","display_name":"Forensic engineering","level":1,"score":0.37079524993896484},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3585802912712097},{"id":"https://openalex.org/C147176958","wikidata":"https://www.wikidata.org/wiki/Q77590","display_name":"Civil engineering","level":1,"score":0.1690947711467743},{"id":"https://openalex.org/C205649164","wikidata":"https://www.wikidata.org/wiki/Q1071","display_name":"Geography","level":0,"score":0.12340575456619263},{"id":"https://openalex.org/C166957645","wikidata":"https://www.wikidata.org/wiki/Q23498","display_name":"Archaeology","level":1,"score":0.0}],"mesh":[],"locations_count":4,"locations":[{"id":"doi:10.3801/iafss.fss.11-517","doi":"https://doi.org/10.3801/iafss.fss.11-517","is_oa":true,"landing_page_url":"https://doi.org/10.3801/iafss.fss.11-517","pdf_url":"http://www.iafss.org/publications/fss/11/517/view/fss_11-517.pdf","source":{"id":"https://openalex.org/S21917004","display_name":"Fire Safety Science","issn_l":"1817-4299","issn":["1817-4299","1817-4302"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","jufo-1","norway-1"],"host_organization":"https://openalex.org/P4323999588","host_organization_name":"International Association of Fire Safety Science","host_organization_lineage":["https://openalex.org/P4323999588"],"host_organization_lineage_names":["International Association of Fire Safety Science"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Fire Safety Science","raw_type":"journal-article"},{"id":"pmh:oai:CiteSeerX.psu:10.1.1.908.2156","doi":null,"is_oa":false,"landing_page_url":"http://citeseerx.ist.psu.edu/viewdoc/summary?doi=10.1.1.908.2156","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"http://www.iafss.org/publications/fss/11/517/view/fss_11-517.pdf","raw_type":"text"},{"id":"pmh:oai:lup.lub.lu.se:d6d415ec-5487-40a8-a6b7-15bd6df9b462","doi":null,"is_oa":false,"landing_page_url":"https://lup.lub.lu.se/record/4301137","pdf_url":null,"source":{"id":"https://openalex.org/S4306400536","display_name":"Lund University Publications (Lund University)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I187531555","host_organization_name":"Lund University","host_organization_lineage":["https://openalex.org/I187531555"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"info:eu-repo/semantics/conferencePaper"},{"id":"mag:2922795288","doi":null,"is_oa":false,"landing_page_url":"https://www.lunduniversity.lu.se/lup/publication/d6d415ec-5487-40a8-a6b7-15bd6df9b462","pdf_url":null,"source":null,"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":null}],"best_oa_location":{"id":"doi:10.3801/iafss.fss.11-517","doi":"https://doi.org/10.3801/iafss.fss.11-517","is_oa":true,"landing_page_url":"https://doi.org/10.3801/iafss.fss.11-517","pdf_url":"http://www.iafss.org/publications/fss/11/517/view/fss_11-517.pdf","source":{"id":"https://openalex.org/S21917004","display_name":"Fire Safety Science","issn_l":"1817-4299","issn":["1817-4299","1817-4302"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","jufo-1","norway-1"],"host_organization":"https://openalex.org/P4323999588","host_organization_name":"International Association of Fire Safety Science","host_organization_lineage":["https://openalex.org/P4323999588"],"host_organization_lineage_names":["International Association of Fire Safety Science"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Fire Safety Science","raw_type":"journal-article"},"sustainable_development_goals":[],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":true,"pdf":true},"content_urls":{"pdf":"https://content.openalex.org/works/W2012481254.pdf","grobid_xml":"https://content.openalex.org/works/W2012481254.grobid-xml"},"referenced_works_count":14,"referenced_works":["https://openalex.org/W9685012","https://openalex.org/W649140406","https://openalex.org/W1520498891","https://openalex.org/W1866975942","https://openalex.org/W1978904760","https://openalex.org/W2023581224","https://openalex.org/W2058548668","https://openalex.org/W2153657316","https://openalex.org/W2168161855","https://openalex.org/W2249649347","https://openalex.org/W2415319661","https://openalex.org/W3194351842","https://openalex.org/W4281249639","https://openalex.org/W6693398229"],"related_works":["https://openalex.org/W1842215268","https://openalex.org/W2359152389","https://openalex.org/W7117878351","https://openalex.org/W1980311382","https://openalex.org/W2025612378","https://openalex.org/W2209196172","https://openalex.org/W2057734500","https://openalex.org/W2567027093","https://openalex.org/W3011934471","https://openalex.org/W2883630681"],"abstract_inverted_index":{"When":[0],"designing":[1,167],"fire":[2,7,19,27,53,67,70,93,119,132,185,194],"safety":[3,20,186,195],"of":[4,44,52,135,141,149,172],"buildings":[5,100,168],"the":[6,17,23,33,36,81,91,170,192],"growth":[8,28,54,71,94,120,133],"rate":[9,29,95,121,134],"is":[10,30,96,115,158,174],"an":[11],"important":[12],"parameter,":[13],"in":[14,56,184],"large":[15],"affecting":[16],"overall":[18,92],"level":[21,43],"within":[22],"building.Generally,":[24],"a":[25,41,86,116,130,159],"deterministic":[26],"used":[31],"raising":[32],"question":[34],"whether":[35,90],"resulting":[37],"design":[38],"arrives":[39],"at":[40],"reasonable":[42],"safety.A":[45],"method":[46,61,82,177],"was":[47,83],"developed":[48,176],"to":[49,161,180,189],"obtain":[50],"distributions":[51],"rates":[55,72],"specific":[57],"building":[58],"types.The":[59],"new":[60],"uses":[62],"data":[63],"from":[64],"two":[65],"sources:":[66],"statistics,":[68],"and":[69,188],"on":[73],"single":[74],"objects":[75],"obtained":[76],"by":[77,85],"calorimetry":[78],"experiments.In":[79],"addition,":[80],"demonstrated":[84],"case":[87],"study":[88],"investigating":[89],"faster":[97],"for":[98,129,163,182],"commercial":[99],"if":[101,107],"arson":[102,123,164,173,183],"fires":[103,124,143,151,165],"are":[104,109,125],"included":[105],"than":[106],"they":[108],"not.The":[110],"results":[111,154],"show":[112],"that":[113,156],"there":[114,157],"considerably":[117],"higher":[118],"when":[122,166,169],"accounted":[126],"for,":[127],"e.g.designing":[128],"fast":[131],"0.047":[136],"kW/s":[137],"2":[138],"covers":[139],"97%":[140],"accidental":[142],"(arson":[144,152],"excluded)":[145],"but":[146],"only":[147],"91%":[148],"all":[150],"included).The":[153],"indicate":[155],"need":[160],"account":[162,181],"probability":[171],"high.The":[175],"provides":[178],"means":[179],"engineering,":[187],"further":[190],"quantify":[191],"achieved":[193],"level.":[196]},"counts_by_year":[{"year":2025,"cited_by_count":2},{"year":2024,"cited_by_count":1},{"year":2021,"cited_by_count":2},{"year":2020,"cited_by_count":1},{"year":2019,"cited_by_count":1},{"year":2018,"cited_by_count":1},{"year":2016,"cited_by_count":1}],"updated_date":"2026-10-30T12:39:25.321706","created_date":"2016-06-24T00:00:00"}
