{"id":"https://openalex.org/W2012134864","doi":"https://doi.org/10.1016/j.engfailanal.2012.12.010","title":"Failure detection and optimization of sugar mill boiler using FMEA and Taguchi method","display_name":"Failure detection and optimization of sugar mill boiler using FMEA and Taguchi method","alternate_titles":[],"publication_year":2013,"publication_date":"2013-01-04","ids":{"openalex":"https://openalex.org/W2012134864","doi":"https://doi.org/10.1016/j.engfailanal.2012.12.010","mag":"2012134864"},"language":"en","primary_location":{"id":"doi:10.1016/j.engfailanal.2012.12.010","doi":"https://doi.org/10.1016/j.engfailanal.2012.12.010","is_oa":false,"landing_page_url":"https://doi.org/10.1016/j.engfailanal.2012.12.010","pdf_url":null,"source":{"id":"https://openalex.org/S152303250","display_name":"Engineering Failure Analysis","issn_l":"1350-6307","issn":["1350-6307","1873-1961"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["anvur-scientific","cwts-core","dongbi-b","jufo-1","ki-jl-1","norway-1","poland-100","russia-white-list-1","vabb-shw"],"host_organization":"https://openalex.org/P4310320990","host_organization_name":"Elsevier BV","host_organization_lineage":["https://openalex.org/P4310320990"],"host_organization_lineage_names":["Elsevier BV"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Engineering Failure Analysis","raw_type":"journal-article"},"parent_works":[],"lineage":["https://openalex.org/W2012134864"],"child_works_count":0,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5050680409","display_name":"A. Mariajayaprakash","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":true,"contributor_roles":[],"raw_author_name":"A. Mariajayaprakash","raw_affiliation_strings":["Department of Mechanical Engineering, Rajiv Gandhi College of Engineering and Technology, Puducherry, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Mechanical Engineering, Rajiv Gandhi College of Engineering and Technology, Puducherry, India","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5109888780","display_name":"Thiagarajan Senthilvelan","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4405254494","display_name":"Puducherry Technological University","ror":"https://ror.org/01w2xgk13","country_code":"IN","type":"education","lineage":["https://openalex.org/I4405254494"]}],"countries":["IN"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"T. Senthilvelan","raw_affiliation_strings":["Department of Mechanical Engineering, Pondicherry Engineering College, Puducherry, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Mechanical Engineering, Pondicherry Engineering College, Puducherry, India","institution_ids":["https://openalex.org/I4405254494"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":["https://openalex.org/A5050680409"],"corresponding_institution_ids":[],"apc_list":{"value":3820,"currency":"USD","value_usd":3820},"apc_paid":null,"fwci":6.9636,"has_fulltext":false,"cited_by_count":74,"reviewed_by_count":0,"citation_normalized_percentile":{"value":0.96597674,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":94,"max":98},"biblio":{"volume":"30","issue":null,"first_page":"17","last_page":"26"},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10876","display_name":"Fault Detection and Control Systems","score":0.3716000020503998,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10876","display_name":"Fault Detection and Control Systems","score":0.3716000020503998,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13213","display_name":"Mechanical Failure Analysis and Simulation","score":0.2409999966621399,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10780","display_name":"Reliability and Maintenance Optimization","score":0.18459999561309814,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/combined-heat-and-power","display_name":"combined heat and power","score":0.8130000233650208},{"id":"https://openalex.org/keywords/failure-mode-and-effects-analysis","display_name":"failure mode and effects analysis","score":0.8199999928474426},{"id":"https://openalex.org/keywords/taguchi-method","display_name":"Taguchi method","score":0.9900000095367432},{"id":"https://openalex.org/keywords/fishbone-diagram","display_name":"fishbone diagram","score":0.7369999885559082},{"id":"https://openalex.org/keywords/equipment-failure","display_name":"equipment failure","score":0.5709999799728394},{"id":"https://openalex.org/keywords/electrical-failure","display_name":"electrical failure","score":0.9129999876022339}],"concepts":[{"id":"https://openalex.org/C2776756539","wikidata":"https://www.wikidata.org/wiki/Q221620","display_name":"Cogeneration","level":4,"score":0.9107722043991089},{"id":"https://openalex.org/C2780013297","wikidata":"https://www.wikidata.org/wiki/Q19596153","display_name":"Boiler (water heating)","level":2,"score":0.795225977897644},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.6464076638221741},{"id":"https://openalex.org/C66283442","wikidata":"https://www.wikidata.org/wiki/Q1389268","display_name":"Failure mode and effects analysis","level":2,"score":0.612747848033905},{"id":"https://openalex.org/C16057445","wikidata":"https://www.wikidata.org/wiki/Q44494","display_name":"Mill","level":2,"score":0.5543983578681946},{"id":"https://openalex.org/C83469408","wikidata":"https://www.wikidata.org/wiki/Q2036525","display_name":"Taguchi methods","level":2,"score":0.5356494784355164},{"id":"https://openalex.org/C548081761","wikidata":"https://www.wikidata.org/wiki/Q180388","display_name":"Waste management","level":1,"score":0.517848551273346},{"id":"https://openalex.org/C21880701","wikidata":"https://www.wikidata.org/wiki/Q2144042","display_name":"Process engineering","level":1,"score":0.45133689045906067},{"id":"https://openalex.org/C2777108408","wikidata":"https://www.wikidata.org/wiki/Q11002","display_name":"Sugar","level":2,"score":0.4344823956489563},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.38745877146720886},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.2445680797100067},{"id":"https://openalex.org/C423512","wikidata":"https://www.wikidata.org/wiki/Q383973","display_name":"Electricity generation","level":3,"score":0.1802472472190857},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.13252750039100647},{"id":"https://openalex.org/C55493867","wikidata":"https://www.wikidata.org/wiki/Q7094","display_name":"Biochemistry","level":1,"score":0.0},{"id":"https://openalex.org/C185592680","wikidata":"https://www.wikidata.org/wiki/Q2329","display_name":"Chemistry","level":0,"score":0.0},{"id":"https://openalex.org/C119857082","wikidata":"https://www.wikidata.org/wiki/Q2539","display_name":"Machine learning","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1016/j.engfailanal.2012.12.010","doi":"https://doi.org/10.1016/j.engfailanal.2012.12.010","is_oa":false,"landing_page_url":"https://doi.org/10.1016/j.engfailanal.2012.12.010","pdf_url":null,"source":{"id":"https://openalex.org/S152303250","display_name":"Engineering Failure Analysis","issn_l":"1350-6307","issn":["1350-6307","1873-1961"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["anvur-scientific","cwts-core","dongbi-b","jufo-1","ki-jl-1","norway-1","poland-100","russia-white-list-1","vabb-shw"],"host_organization":"https://openalex.org/P4310320990","host_organization_name":"Elsevier BV","host_organization_lineage":["https://openalex.org/P4310320990"],"host_organization_lineage_names":["Elsevier BV"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Engineering Failure Analysis","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/9","display_name":"Industry, innovation and infrastructure","score":0.428600013256073}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":30,"referenced_works":["https://openalex.org/W1987505034","https://openalex.org/W1988343386","https://openalex.org/W2002717126","https://openalex.org/W2002780008","https://openalex.org/W2008368933","https://openalex.org/W2025343356","https://openalex.org/W2026097641","https://openalex.org/W2026189503","https://openalex.org/W2033212700","https://openalex.org/W2040630760","https://openalex.org/W2046734647","https://openalex.org/W2048828185","https://openalex.org/W2063213930","https://openalex.org/W2067701583","https://openalex.org/W2081570492","https://openalex.org/W2082498437","https://openalex.org/W2091649586","https://openalex.org/W2093498343","https://openalex.org/W2105192473","https://openalex.org/W2123798461","https://openalex.org/W2129967715","https://openalex.org/W2138232691","https://openalex.org/W2138502822","https://openalex.org/W2254677968","https://openalex.org/W2288373768","https://openalex.org/W2545026842","https://openalex.org/W3025102719","https://openalex.org/W3145165411","https://openalex.org/W3209858794","https://openalex.org/W6802698834"],"related_works":["https://openalex.org/W7098019689","https://openalex.org/W2891536200","https://openalex.org/W7221004672","https://openalex.org/W2951423649","https://openalex.org/W7007934491","https://openalex.org/W7097882297","https://openalex.org/W2077801568","https://openalex.org/W2186154426","https://openalex.org/W3047969063","https://openalex.org/W4406091723"],"abstract_inverted_index":null,"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W2012134864","counts_by_year":[{"year":2026,"cited_by_count":2},{"year":2025,"cited_by_count":3},{"year":2024,"cited_by_count":5},{"year":2023,"cited_by_count":4},{"year":2022,"cited_by_count":6},{"year":2021,"cited_by_count":8},{"year":2020,"cited_by_count":6},{"year":2019,"cited_by_count":7},{"year":2018,"cited_by_count":6},{"year":2017,"cited_by_count":5},{"year":2016,"cited_by_count":4},{"year":2015,"cited_by_count":6},{"year":2014,"cited_by_count":6},{"year":2013,"cited_by_count":6}],"updated_date":"2026-11-21T10:27:49.728292","created_date":"2016-06-24T00:00:00"}