{"id":"https://openalex.org/W2012120201","doi":"https://doi.org/10.1109/tpel.2010.2094208","title":"Bus Selection in Multibus DC Microgrids","display_name":"Bus Selection in Multibus DC Microgrids","alternate_titles":[],"publication_year":2010,"publication_date":"2010-11-30","ids":{"openalex":"https://openalex.org/W2012120201","doi":"https://doi.org/10.1109/tpel.2010.2094208","mag":"2012120201"},"language":"en","primary_location":{"id":"doi:10.1109/tpel.2010.2094208","doi":"https://doi.org/10.1109/tpel.2010.2094208","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tpel.2010.2094208","pdf_url":null,"source":{"id":"https://openalex.org/S29875816","display_name":"IEEE Transactions on Power Electronics","issn_l":"0885-8993","issn":["0885-8993","1941-0107"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-a","jufo-3","norway-2","poland-200","russia-white-list-1"],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Power Electronics","raw_type":"journal-article"},"parent_works":[],"lineage":["https://openalex.org/W2012120201"],"child_works_count":0,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5067847564","display_name":"Robert S. Balog","orcid":"https://orcid.org/0000-0002-0090-4259","observed_orcids":["https://orcid.org/0000-0002-0090-4259"]},"institutions":[{"id":"https://openalex.org/I91045830","display_name":"Texas A&M University","ror":"https://ror.org/01f5ytq51","country_code":"US","type":"education","lineage":["https://openalex.org/I91045830"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Robert S. Balog","raw_affiliation_strings":["Department of Electrical and Computer Engineering, 216P Zachry Engineering Center, Texas A and M University, College Station, TX, USA","Dept. of Electr. & Comput. Eng, Texas A&M Univ., College Station, TX, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical and Computer Engineering, 216P Zachry Engineering Center, Texas A and M University, College Station, TX, USA","institution_ids":["https://openalex.org/I91045830"]},{"raw_affiliation_string":"Dept. of Electr. & Comput. Eng, Texas A&M Univ., College Station, TX, USA","institution_ids":["https://openalex.org/I91045830"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5025821826","display_name":"Philip T. Krein","orcid":"https://orcid.org/0000-0001-8048-6968","observed_orcids":["https://orcid.org/0000-0001-8048-6968"]},"institutions":[{"id":"https://openalex.org/I157725225","display_name":"University of Illinois Urbana-Champaign","ror":"https://ror.org/047426m28","country_code":"US","type":"education","lineage":["https://openalex.org/I157725225"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Philip T. Krein","raw_affiliation_strings":["Department of Electrical and Computer Engineering, 341 Everitt Laboratory, University of Illinois, Urbana-Champaign, Urbana, IL, USA","Dept of Electr. & Comput. Engg, Univ. of Illinois at Urbana-Champaign, Urbana, IL, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical and Computer Engineering, 341 Everitt Laboratory, University of Illinois, Urbana-Champaign, Urbana, IL, USA","institution_ids":["https://openalex.org/I157725225"]},{"raw_affiliation_string":"Dept of Electr. & Comput. Engg, Univ. of Illinois at Urbana-Champaign, Urbana, IL, USA","institution_ids":["https://openalex.org/I157725225"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":{"value":2645,"currency":"USD","value_usd":2645},"apc_paid":null,"fwci":8.1997,"has_fulltext":false,"cited_by_count":123,"citation_normalized_percentile":{"value":0.97141566,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":96,"max":99},"biblio":{"volume":"26","issue":"3","first_page":"860","last_page":"867"},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9384999871253967,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9384999871253967,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":0.03959999978542328,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":0.008899999782443047,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/bus-selection","display_name":"bus selection","score":0.7229999899864197},{"id":"https://openalex.org/keywords/redundancy","display_name":"redundancy","score":0.6449999809265137},{"id":"https://openalex.org/keywords/dwell-time","display_name":"dwell time","score":0.6639999747276306},{"id":"https://openalex.org/keywords/state-dependent-switching","display_name":"state-dependent switching","score":0.8159999847412109},{"id":"https://openalex.org/keywords/fault-tolerance","display_name":"fault tolerance","score":0.6159999966621399},{"id":"https://openalex.org/keywords/distributed-control","display_name":"distributed control","score":0.6230000257492065},{"id":"https://openalex.org/keywords/dc-power-systems","display_name":"DC power systems","score":0.6349999904632568}],"concepts":[{"id":"https://openalex.org/C152124472","wikidata":"https://www.wikidata.org/wiki/Q1204361","display_name":"Redundancy (engineering)","level":2,"score":0.6559754610061646},{"id":"https://openalex.org/C2778422915","wikidata":"https://www.wikidata.org/wiki/Q10302051","display_name":"Converters","level":3,"score":0.6266504526138306},{"id":"https://openalex.org/C136321198","wikidata":"https://www.wikidata.org/wiki/Q2377054","display_name":"System bus","level":2,"score":0.548163115978241},{"id":"https://openalex.org/C78434282","wikidata":"https://www.wikidata.org/wiki/Q11656","display_name":"Diode","level":2,"score":0.5088849067687988},{"id":"https://openalex.org/C203315745","wikidata":"https://www.wikidata.org/wiki/Q2235486","display_name":"Control bus","level":3,"score":0.49881505966186523},{"id":"https://openalex.org/C202015219","wikidata":"https://www.wikidata.org/wiki/Q6664300","display_name":"Local bus","level":4,"score":0.4968858063220978},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.4905247092247009},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.475965678691864},{"id":"https://openalex.org/C115314053","wikidata":"https://www.wikidata.org/wiki/Q7538399","display_name":"Slack bus","level":5,"score":0.45874103903770447},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4435109794139862},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.42993441224098206},{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.42655065655708313},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.41312891244888306},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.37867605686187744},{"id":"https://openalex.org/C108755667","wikidata":"https://www.wikidata.org/wiki/Q1930258","display_name":"AC power","level":3,"score":0.2804974317550659},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.1716964840888977},{"id":"https://openalex.org/C9390403","wikidata":"https://www.wikidata.org/wiki/Q3966","display_name":"Computer hardware","level":1,"score":0.16642138361930847},{"id":"https://openalex.org/C181361822","wikidata":"https://www.wikidata.org/wiki/Q556030","display_name":"Power-flow study","level":4,"score":0.13873684406280518},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tpel.2010.2094208","doi":"https://doi.org/10.1109/tpel.2010.2094208","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tpel.2010.2094208","pdf_url":null,"source":{"id":"https://openalex.org/S29875816","display_name":"IEEE Transactions on Power Electronics","issn_l":"0885-8993","issn":["0885-8993","1941-0107"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-a","jufo-3","norway-2","poland-200","russia-white-list-1"],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Power Electronics","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","score":0.75,"id":"https://metadata.un.org/sdg/7"},{"display_name":"Industry, innovation and infrastructure","score":0.7207000255584717,"id":"https://metadata.un.org/sdg/9"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":39,"referenced_works":["https://openalex.org/W1495424053","https://openalex.org/W1504052325","https://openalex.org/W1552094772","https://openalex.org/W1680138613","https://openalex.org/W1685082053","https://openalex.org/W1796445824","https://openalex.org/W1860451341","https://openalex.org/W1895861116","https://openalex.org/W1918246996","https://openalex.org/W1928173439","https://openalex.org/W1956806770","https://openalex.org/W1968909530","https://openalex.org/W1971394149","https://openalex.org/W1995063858","https://openalex.org/W2017330833","https://openalex.org/W2036782525","https://openalex.org/W2066242867","https://openalex.org/W2099211093","https://openalex.org/W2105303942","https://openalex.org/W2111919291","https://openalex.org/W2113229722","https://openalex.org/W2120627602","https://openalex.org/W2121005287","https://openalex.org/W2122168196","https://openalex.org/W2123834662","https://openalex.org/W2124332712","https://openalex.org/W2134648597","https://openalex.org/W2139033201","https://openalex.org/W2139608023","https://openalex.org/W2139652177","https://openalex.org/W2147223581","https://openalex.org/W2151206372","https://openalex.org/W2154381415","https://openalex.org/W2158017035","https://openalex.org/W2162661160","https://openalex.org/W2178386635","https://openalex.org/W2540338209","https://openalex.org/W4232628115","https://openalex.org/W6677774092"],"related_works":["https://openalex.org/W2146405091","https://openalex.org/W2109325722","https://openalex.org/W2995468915","https://openalex.org/W2526995180","https://openalex.org/W2019002871","https://openalex.org/W2050973969","https://openalex.org/W2069092873","https://openalex.org/W2773832052","https://openalex.org/W4207034178","https://openalex.org/W1510574183"],"abstract_inverted_index":{"DC":[0],"power":[1,22],"systems":[2],"can":[3],"be":[4],"made":[5],"more":[6],"reliable":[7],"by":[8,100],"using":[9],"multiple":[10,17,42],"buses":[11,15],"for":[12,20,67],"redundancy.":[13],"Multiple":[14],"provide":[16],"configuration":[18],"options":[19],"supplying":[21],"to":[23,37,41,139],"the":[24,33,45,59,65,105,113,116,141,145],"load.":[25],"Diode":[26],"OR'ing":[27],"with":[28,90],"auctioneering":[29,83,91],"diodes":[30,92],"is":[31,48,134],"perhaps":[32],"most":[34],"common":[35],"method":[36],"connect":[38],"a":[39,71,80,125,137],"load":[40],"buses.":[43],"Although":[44],"diode":[46],"action":[47],"automatic":[49],"and":[50,64,87],"fault-tolerant,":[51],"it":[52],"results":[53],"in":[54,70,79,112,144],"ill-defined":[55],"bus":[56,60,88,106,117,146],"currents":[57],"when":[58],"voltages":[61],"are":[62,93],"similar":[63],"potential":[66],"uncontrolled":[68],"switching":[69,86,143],"faulted":[72],"high-impedance":[73],"system-operating":[74],"scenarios":[75],"not":[76,122],"often":[77],"included":[78],"discussion":[81],"on":[82,124],"diodes.":[84],"Active":[85],"converters":[89],"control":[94,103],"techniques":[95,120],"that":[96],"overcome":[97],"these":[98,119],"limitations":[99],"providing":[101],"full":[102],"over":[104],"selection":[107],"process.":[108],"Using":[109],"local":[110],"information":[111],"form":[114],"of":[115],"voltage,":[118],"do":[121],"rely":[123],"centralized":[126],"controller,":[127],"which":[128],"improves":[129],"system":[130],"reliability.":[131],"Dwell":[132],"time":[133],"proposed":[135],"as":[136],"technique":[138],"stabilize":[140],"state-dependent":[142],"selector.":[147]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W2012120201","counts_by_year":[{"year":2026,"cited_by_count":3},{"year":2025,"cited_by_count":8},{"year":2024,"cited_by_count":6},{"year":2023,"cited_by_count":9},{"year":2022,"cited_by_count":6},{"year":2021,"cited_by_count":5},{"year":2020,"cited_by_count":5},{"year":2019,"cited_by_count":13},{"year":2018,"cited_by_count":10},{"year":2017,"cited_by_count":10},{"year":2016,"cited_by_count":13},{"year":2015,"cited_by_count":6},{"year":2014,"cited_by_count":9},{"year":2013,"cited_by_count":10},{"year":2012,"cited_by_count":8}],"updated_date":"2026-11-16T12:05:36.265796","created_date":"2016-06-24T00:00:00"}
