{"id":"https://openalex.org/W2011980787","doi":"https://doi.org/10.1108/02632779910256533","title":"Problems of the retrofit installation of sprinkler systems in old high\u2010rise buildings: a case study","display_name":"Problems of the retrofit installation of sprinkler systems in old high\u2010rise buildings: a case study","publication_year":1999,"publication_date":"1999-03-01","ids":{"openalex":"https://openalex.org/W2011980787","doi":"https://doi.org/10.1108/02632779910256533","mag":"2011980787"},"language":"en","primary_location":{"id":"doi:10.1108/02632779910256533","doi":"https://doi.org/10.1108/02632779910256533","is_oa":false,"landing_page_url":"https://doi.org/10.1108/02632779910256533","pdf_url":null,"source":{"id":"https://openalex.org/S148874517","display_name":"Facilities","issn_l":"0263-2772","issn":["0263-2772","1758-7131"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["abdc-b","anvur-class-a","anvur-scientific","cwts-core","fnege-4","jufo-2","norway-1","poland-70","russia-white-list-1"],"host_organization":"https://openalex.org/P4310319811","host_organization_name":"Emerald Publishing Limited","host_organization_lineage":["https://openalex.org/P4310319811"],"host_organization_lineage_names":["Emerald Publishing Limited"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Facilities","raw_type":"journal-article"},"volume":null,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5050796957","display_name":"W. K. Chow","orcid":"https://orcid.org/0000-0001-8398-3126","observed_orcids":["https://orcid.org/0000-0001-8398-3126"]},"institutions":[{"id":"https://openalex.org/I14243506","display_name":"Hong Kong Polytechnic University","ror":"https://ror.org/0030zas98","country_code":"HK","type":"education","lineage":["https://openalex.org/I14243506"]}],"countries":["HK"],"is_corresponding":false,"raw_author_name":"W.K. Chow","raw_affiliation_strings":["The Department of Building Services Engineering at the Hong Kong Polytechnic University, Hong Kong, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"The Department of Building Services Engineering at the Hong Kong Polytechnic University, Hong Kong, China","institution_ids":["https://openalex.org/I14243506"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5082362471","display_name":"Hoishing Chong","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I14243506","display_name":"Hong Kong Polytechnic University","ror":"https://ror.org/0030zas98","country_code":"HK","type":"education","lineage":["https://openalex.org/I14243506"]}],"countries":["HK"],"is_corresponding":false,"raw_author_name":"H.W. Chong","raw_affiliation_strings":["The Department of Building Services Engineering at the Hong Kong Polytechnic University, Hong Kong, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"The Department of Building Services Engineering at the Hong Kong Polytechnic University, Hong Kong, China","institution_ids":["https://openalex.org/I14243506"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5073233094","display_name":"L.T. Wong","orcid":"https://orcid.org/0000-0001-8449-4973","observed_orcids":["https://orcid.org/0000-0001-8449-4973"]},"institutions":[{"id":"https://openalex.org/I14243506","display_name":"Hong Kong Polytechnic University","ror":"https://ror.org/0030zas98","country_code":"HK","type":"education","lineage":["https://openalex.org/I14243506"]}],"countries":["HK"],"is_corresponding":false,"raw_author_name":"L.T. Wong","raw_affiliation_strings":["The Department of Building Services Engineering at the Hong Kong Polytechnic University, Hong Kong, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"The Department of Building Services Engineering at the Hong Kong Polytechnic University, Hong Kong, China","institution_ids":["https://openalex.org/I14243506"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I14243506"],"apc_list":null,"apc_paid":null,"fwci":2.0643,"has_fulltext":false,"cited_by_count":4,"citation_normalized_percentile":{"value":0.86604742,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":94},"biblio":{"volume":"17","issue":"3/4","first_page":"112","last_page":"119"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11317","display_name":"Fire dynamics and safety research","score":0.9595000147819519,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11317","display_name":"Fire dynamics and safety research","score":0.9595000147819519,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12597","display_name":"Fire Detection and Safety Systems","score":0.031599998474121094,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12102","display_name":"Fire effects on concrete materials","score":0.00279999990016222,"subfield":{"id":"https://openalex.org/subfields/2205","display_name":"Civil and Structural Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/sprinkler-systems","display_name":"sprinkler systems","score":0.9470000267028809},{"id":"https://openalex.org/keywords/high-rise-buildings","display_name":"high-rise buildings","score":0.8930000066757202},{"id":"https://openalex.org/keywords/fire-protection","display_name":"fire protection","score":0.7120000123977661},{"id":"https://openalex.org/keywords/hong-kong-buildings","display_name":"Hong Kong buildings","score":0.4690000116825104}],"concepts":[{"id":"https://openalex.org/C146778888","wikidata":"https://www.wikidata.org/wiki/Q836862","display_name":"Installation","level":2,"score":0.8691580295562744},{"id":"https://openalex.org/C160331591","wikidata":"https://www.wikidata.org/wiki/Q7075743","display_name":"Occupancy","level":2,"score":0.7404319643974304},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.6597467064857483},{"id":"https://openalex.org/C147176958","wikidata":"https://www.wikidata.org/wiki/Q77590","display_name":"Civil engineering","level":1,"score":0.5719807147979736},{"id":"https://openalex.org/C2778368411","wikidata":"https://www.wikidata.org/wiki/Q24662","display_name":"Retrofitting","level":2,"score":0.5674970746040344},{"id":"https://openalex.org/C170154142","wikidata":"https://www.wikidata.org/wiki/Q150737","display_name":"Architectural engineering","level":1,"score":0.5387400984764099},{"id":"https://openalex.org/C2776505523","wikidata":"https://www.wikidata.org/wiki/Q4785468","display_name":"Plan (archaeology)","level":2,"score":0.5317690968513489},{"id":"https://openalex.org/C2987755307","wikidata":"https://www.wikidata.org/wiki/Q2997557","display_name":"Fire hazard","level":2,"score":0.4809826612472534},{"id":"https://openalex.org/C2992120199","wikidata":"https://www.wikidata.org/wiki/Q18142","display_name":"High rise","level":2,"score":0.4494681656360626},{"id":"https://openalex.org/C122156500","wikidata":"https://www.wikidata.org/wiki/Q41399","display_name":"Fire protection","level":2,"score":0.43805214762687683},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.2763006091117859},{"id":"https://openalex.org/C205649164","wikidata":"https://www.wikidata.org/wiki/Q1071","display_name":"Geography","level":0,"score":0.11980068683624268},{"id":"https://openalex.org/C526734887","wikidata":"https://www.wikidata.org/wiki/Q832237","display_name":"Environmental protection","level":1,"score":0.10153946280479431},{"id":"https://openalex.org/C66938386","wikidata":"https://www.wikidata.org/wiki/Q633538","display_name":"Structural engineering","level":1,"score":0.07220810651779175},{"id":"https://openalex.org/C166957645","wikidata":"https://www.wikidata.org/wiki/Q23498","display_name":"Archaeology","level":1,"score":0.0},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1108/02632779910256533","doi":"https://doi.org/10.1108/02632779910256533","is_oa":false,"landing_page_url":"https://doi.org/10.1108/02632779910256533","pdf_url":null,"source":{"id":"https://openalex.org/S148874517","display_name":"Facilities","issn_l":"0263-2772","issn":["0263-2772","1758-7131"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["abdc-b","anvur-class-a","anvur-scientific","cwts-core","fnege-4","jufo-2","norway-1","poland-70","russia-white-list-1"],"host_organization":"https://openalex.org/P4310319811","host_organization_name":"Emerald Publishing Limited","host_organization_lineage":["https://openalex.org/P4310319811"],"host_organization_lineage_names":["Emerald Publishing Limited"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Facilities","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.8787999749183655,"id":"https://metadata.un.org/sdg/11","display_name":"Sustainable cities and communities"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":1,"referenced_works":["https://openalex.org/W183066137"],"related_works":["https://openalex.org/W2493334039","https://openalex.org/W2070496543","https://openalex.org/W7203760569","https://openalex.org/W2358973839","https://openalex.org/W7029173656","https://openalex.org/W2515498592","https://openalex.org/W7008873108","https://openalex.org/W2352868777","https://openalex.org/W2529176329","https://openalex.org/W3429730"],"abstract_inverted_index":{"A":[0,71],"field":[1],"survey":[2],"on":[3],"36":[4],"old":[5,79,129,175],"high\u2010rise":[6,80,130,176],"buildings":[7,69,131],"in":[8,32,77,99,128,149,174],"the":[9,23,26,56,65,68,91,109,113,146,150,156,168,179],"Hong":[10,17],"Kong":[11],"Special":[12],"Administrative":[13],"Region":[14],"(HKSAR,":[15],"formerly":[16],"Kong)":[18],"was":[19,74,88,117,137],"conducted":[20],"to":[21,51,142],"study":[22],"problems":[24,140],"of":[25,29,41,49,58,67,101,124,170],"retrofit":[27,92,182],"installation":[28,184],"sprinkler":[30,59,84,93,114,126,157,172,183],"systems":[31,94,127,173],"those":[33],"buildings.":[34,177],"The":[35],"floor":[36],"plan,":[37],"occupancy":[38,151],"type,":[39],"number":[40,48,57],"occupants,":[42],"fire":[43],"load":[44],"distribution,":[45],"hazard":[46],"class,":[47],"sprinklers":[50],"protection":[52],"area":[53],"ratio":[54],"and":[55,121,165],"heads":[60],"were":[61,132],"studied":[62],"along":[63],"with":[64,83],"characteristics":[66],"identified.":[70],"detailed":[72],"investigation":[73],"carried":[75],"out":[76],"an":[78],"non\u2010residential":[81],"building":[82],"system":[85,158],"installed.":[86],"It":[87],"observed":[89],"that":[90,139],"might":[95,106],"not":[96,107,118],"perform":[97],"satisfactorily":[98],"case":[100],"fire.":[102],"Further,":[103],"water":[104,162],"discharged":[105],"reach":[108],"ground":[110],"level":[111],"because":[112],"sprays":[115],"pattern":[116],"considered.":[119],"Technical":[120],"financial":[122],"difficulties":[123],"installing":[125,171],"studied.":[133],"In":[134],"addition,":[135],"it":[136],"ascertained":[138],"related":[141],"structural":[143],"loading":[144],"for":[145,155,181],"system,":[147],"variation":[148],"level,":[152],"allocating":[153],"spaces":[154],"components":[159],"such":[160],"as":[161],"tank,":[163],"pumps":[164],"pipes":[166],"compound":[167],"complexity":[169],"Finally,":[178],"cost":[180],"has":[185],"been":[186],"estimated.":[187]},"counts_by_year":[{"year":2016,"cited_by_count":1}],"updated_date":"2026-10-30T12:39:25.321706","created_date":"2016-06-24T00:00:00"}
