{"id":"https://openalex.org/W2007887591","doi":"https://doi.org/10.1109/cloud.2010.25","title":"Performance and Power Management for Cloud Infrastructures","display_name":"Performance and Power Management for Cloud Infrastructures","publication_year":2010,"publication_date":"2010-07-01","ids":{"openalex":"https://openalex.org/W2007887591","doi":"https://doi.org/10.1109/cloud.2010.25","mag":"2007887591"},"language":"en","primary_location":{"id":"doi:10.1109/cloud.2010.25","doi":"https://doi.org/10.1109/cloud.2010.25","is_oa":false,"landing_page_url":"https://doi.org/10.1109/cloud.2010.25","pdf_url":null,"source":{"id":"https://openalex.org/S4393918219","display_name":"IEEE ... International Conference on Cloud Computing","issn_l":"2159-6190","issn":["2159-6190"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":["jufo-1","norway-1"],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2010 IEEE 3rd International Conference on Cloud Computing","raw_type":"proceedings-article"},"volume":null,"type":"conference-paper","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5088807482","display_name":"Hien Nguyen Van","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I19370010","display_name":"Orange (France)","ror":"https://ror.org/035j0tq82","country_code":"FR","type":"company","lineage":["https://openalex.org/I19370010"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"Hien Nguyen Van","raw_affiliation_strings":["Orange Laboratories, Issy-les-Moulineaux, France","ASCOLA - Aspect and composition languages (France)","Orange Labs R&D [Rennes] (4 rue du Clos Courtel, 35112 Cesson-S\u00e9vign\u00e9 Cedex, France - France)"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Orange Laboratories, Issy-les-Moulineaux, France","institution_ids":["https://openalex.org/I19370010"]},{"raw_affiliation_string":"ASCOLA - Aspect and composition languages (France)","institution_ids":[]},{"raw_affiliation_string":"Orange Labs R&D [Rennes] (4 rue du Clos Courtel, 35112 Cesson-S\u00e9vign\u00e9 Cedex, France - France)","institution_ids":["https://openalex.org/I19370010"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5111967579","display_name":"Fr\u00e9d\u00e9ric Dang Tran","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I19370010","display_name":"Orange (France)","ror":"https://ror.org/035j0tq82","country_code":"FR","type":"company","lineage":["https://openalex.org/I19370010"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"Fr\u00e9d\u00e9ric Dang Tran","raw_affiliation_strings":["Orange Laboratories, Issy-les-Moulineaux, France","Orange Labs R&D [Rennes] (4 rue du Clos Courtel, 35112 Cesson-S\u00e9vign\u00e9 Cedex, France - France)"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Orange Laboratories, Issy-les-Moulineaux, France","institution_ids":["https://openalex.org/I19370010"]},{"raw_affiliation_string":"Orange Labs R&D [Rennes] (4 rue du Clos Courtel, 35112 Cesson-S\u00e9vign\u00e9 Cedex, France - France)","institution_ids":["https://openalex.org/I19370010"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5089583902","display_name":"Jean-Marc Menaud","orcid":"https://orcid.org/0000-0003-1804-3722","observed_orcids":["https://orcid.org/0000-0003-1804-3722"]},"institutions":[{"id":"https://openalex.org/I1326498283","display_name":"Institut national de recherche en sciences et technologies du num\u00e9rique","ror":"https://ror.org/02kvxyf05","country_code":"FR","type":"government","lineage":["https://openalex.org/I1326498283"]},{"id":"https://openalex.org/I4210165258","display_name":"Laboratoire d'informatique de Nantes Atlantique","ror":"https://ror.org/05487pd16","country_code":"FR","type":"facility","lineage":["https://openalex.org/I1294671590","https://openalex.org/I1326498283","https://openalex.org/I205703379","https://openalex.org/I4210127572","https://openalex.org/I4210159245","https://openalex.org/I4210165258","https://openalex.org/I97188460"]},{"id":"https://openalex.org/I4405265706","display_name":"\u00c9cole nationale sup\u00e9rieure des Mines de Nantes","ror":"https://ror.org/05gzmxp80","country_code":"FR","type":"education","lineage":["https://openalex.org/I205703379","https://openalex.org/I4210127572","https://openalex.org/I4405265706"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"Jean-Marc Menaud","raw_affiliation_strings":["LINA, Mines de Nantes-INRIA, Nantes, France","ASCOLA - Aspect and composition languages (France)","LINA - Laboratoire d'Informatique de Nantes Atlantique (LINA - Facult\u00e9 des Sciences 2 rue de la Houssini\u00e8re - BP 92208 44322 NANTES CEDEX 3 - France)"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"LINA, Mines de Nantes-INRIA, Nantes, France","institution_ids":["https://openalex.org/I1326498283","https://openalex.org/I4210165258","https://openalex.org/I4405265706"]},{"raw_affiliation_string":"ASCOLA - Aspect and composition languages (France)","institution_ids":[]},{"raw_affiliation_string":"LINA - Laboratoire d'Informatique de Nantes Atlantique (LINA - Facult\u00e9 des Sciences 2 rue de la Houssini\u00e8re - BP 92208 44322 NANTES CEDEX 3 - France)","institution_ids":["https://openalex.org/I4210165258"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":4,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":9.1138,"has_fulltext":false,"cited_by_count":169,"citation_normalized_percentile":{"value":0.98509477,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":88,"max":100},"biblio":{"volume":null,"issue":null,"first_page":"329","last_page":"336"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10101","display_name":"Cloud Computing and Resource Management","score":1.0,"subfield":{"id":"https://openalex.org/subfields/1710","display_name":"Information Systems"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10101","display_name":"Cloud Computing and Resource Management","score":1.0,"subfield":{"id":"https://openalex.org/subfields/1710","display_name":"Information Systems"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14098","display_name":"Energy Efficiency in Computing","score":0.00019999999494757503,"subfield":{"id":"https://openalex.org/subfields/1708","display_name":"Hardware and Architecture"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10715","display_name":"Distributed and Parallel Computing Systems","score":0.0,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/cloud-computing","display_name":"cloud computing","score":0.7239999771118164},{"id":"https://openalex.org/keywords/power-management","display_name":"power management","score":0.7319999933242798},{"id":"https://openalex.org/keywords/energy-consumption","display_name":"energy consumption","score":0.6520000100135803},{"id":"https://openalex.org/keywords/virtual-machine-provisioning","display_name":"virtual machine provisioning","score":0.8899999856948853},{"id":"https://openalex.org/keywords/virtual-machine-placement","display_name":"virtual machine placement","score":0.8550000190734863},{"id":"https://openalex.org/keywords/resource-management","display_name":"resource management","score":0.6660000085830688},{"id":"https://openalex.org/keywords/constraint-satisfaction","display_name":"constraint satisfaction","score":0.671999990940094},{"id":"https://openalex.org/keywords/utility-based-resource-allocation","display_name":"utility-based resource allocation","score":0.6669999957084656},{"id":"https://openalex.org/keywords/service-level-agreements","display_name":"service level agreements","score":0.8169999718666077},{"id":"https://openalex.org/keywords/application-performance","display_name":"application performance","score":0.6859999895095825},{"id":"https://openalex.org/keywords/data-centers","display_name":"data centers","score":0.6809999942779541},{"id":"https://openalex.org/keywords/resource-contention","display_name":"resource contention","score":0.6919999718666077}],"concepts":[{"id":"https://openalex.org/C172191483","wikidata":"https://www.wikidata.org/wiki/Q1071806","display_name":"Provisioning","level":2,"score":0.914218008518219},{"id":"https://openalex.org/C79974875","wikidata":"https://www.wikidata.org/wiki/Q483639","display_name":"Cloud computing","level":2,"score":0.8733679056167603},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.7834608554840088},{"id":"https://openalex.org/C25344961","wikidata":"https://www.wikidata.org/wiki/Q192726","display_name":"Virtual machine","level":2,"score":0.6718769073486328},{"id":"https://openalex.org/C120314980","wikidata":"https://www.wikidata.org/wiki/Q180634","display_name":"Distributed computing","level":1,"score":0.6296131610870361},{"id":"https://openalex.org/C2780165032","wikidata":"https://www.wikidata.org/wiki/Q16869822","display_name":"Energy consumption","level":2,"score":0.5479587912559509},{"id":"https://openalex.org/C2780609101","wikidata":"https://www.wikidata.org/wiki/Q17156588","display_name":"Resource management (computing)","level":2,"score":0.49542486667633057},{"id":"https://openalex.org/C98045186","wikidata":"https://www.wikidata.org/wiki/Q205663","display_name":"Process (computing)","level":2,"score":0.4851577877998352},{"id":"https://openalex.org/C26517878","wikidata":"https://www.wikidata.org/wiki/Q228039","display_name":"Key (lock)","level":2,"score":0.4440983235836029},{"id":"https://openalex.org/C2778160497","wikidata":"https://www.wikidata.org/wiki/Q869830","display_name":"Service-level agreement","level":3,"score":0.43678203225135803},{"id":"https://openalex.org/C2984118289","wikidata":"https://www.wikidata.org/wiki/Q29954","display_name":"Power consumption","level":3,"score":0.4363682270050049},{"id":"https://openalex.org/C2776036281","wikidata":"https://www.wikidata.org/wiki/Q48769818","display_name":"Constraint (computer-aided design)","level":2,"score":0.41887378692626953},{"id":"https://openalex.org/C206345919","wikidata":"https://www.wikidata.org/wiki/Q20380951","display_name":"Resource (disambiguation)","level":2,"score":0.4173257350921631},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.2866836190223694},{"id":"https://openalex.org/C31258907","wikidata":"https://www.wikidata.org/wiki/Q1301371","display_name":"Computer network","level":1,"score":0.2436804175376892},{"id":"https://openalex.org/C38652104","wikidata":"https://www.wikidata.org/wiki/Q3510521","display_name":"Computer security","level":1,"score":0.22965818643569946},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.21546825766563416},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.08445718884468079},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/cloud.2010.25","doi":"https://doi.org/10.1109/cloud.2010.25","is_oa":false,"landing_page_url":"https://doi.org/10.1109/cloud.2010.25","pdf_url":null,"source":{"id":"https://openalex.org/S4393918219","display_name":"IEEE ... International Conference on Cloud Computing","issn_l":"2159-6190","issn":["2159-6190"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":["jufo-1","norway-1"],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2010 IEEE 3rd International Conference on Cloud Computing","raw_type":"proceedings-article"},{"id":"pmh:oai:HAL:hal-00481701v1","doi":null,"is_oa":false,"landing_page_url":"https://hal.science/hal-00481701","pdf_url":null,"source":{"id":"https://openalex.org/S4306402512","display_name":"HAL","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I4405252976","host_organization_name":"Centre pour la Communication Scientifique Directe","host_organization_lineage":["https://openalex.org/I4405252976"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Cloud 2010, Jul 2010, Miami - Florida, United States. pp.329-336, &#x27E8;10.1109/CLOUD.2010.25&#x27E9;","raw_type":"info:eu-repo/semantics/conferenceObject"}],"best_oa_location":null,"sustainable_development_goals":[],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":18,"referenced_works":["https://openalex.org/W1530196379","https://openalex.org/W1815612875","https://openalex.org/W1982290754","https://openalex.org/W2028603278","https://openalex.org/W2102071147","https://openalex.org/W2103375760","https://openalex.org/W2109239225","https://openalex.org/W2125614502","https://openalex.org/W2131726714","https://openalex.org/W2135323989","https://openalex.org/W2137240782","https://openalex.org/W2139177908","https://openalex.org/W2141450509","https://openalex.org/W2154289341","https://openalex.org/W2160756722","https://openalex.org/W2163065828","https://openalex.org/W4243947286","https://openalex.org/W4254259326"],"related_works":["https://openalex.org/W7053465599","https://openalex.org/W2366041351","https://openalex.org/W31866323","https://openalex.org/W6964237660","https://openalex.org/W2117990756","https://openalex.org/W1989965761","https://openalex.org/W2784123117","https://openalex.org/W2946896627","https://openalex.org/W2986811080","https://openalex.org/W2908089272"],"abstract_inverted_index":{"A":[0],"key":[1],"issue":[2],"for":[3],"Cloud":[4],"Computing":[5],"data-centers":[6],"is":[7],"to":[8,73,100,111],"maximize":[9],"their":[10,74],"profits":[11],"by":[12],"minimizing":[13],"power":[14],"consumption":[15,109],"and":[16,39,76,107],"SLA":[17],"violations":[18],"of":[19,67,81,117],"hosted":[20,69],"applications.":[21],"In":[22],"this":[23],"paper,":[24],"we":[25],"propose":[26],"a":[27,32,40,60],"resource":[28,113],"management":[29],"framework":[30],"combining":[31],"utility-based":[33],"dynamic":[34,41],"Virtual":[35],"Machine":[36],"provisioning":[37,55],"manager":[38],"VM":[42,54],"placement":[43],"manager.":[44],"Both":[45],"problems":[46],"are":[47],"modeled":[48],"as":[49],"constraint":[50],"satisfaction":[51],"problems.":[52],"The":[53],"process":[56],"aims":[57],"at":[58],"maximizing":[59],"global":[61],"utility":[62],"capturing":[63],"both":[64],"the":[65,68,77,82],"performance":[66,106],"applications":[70],"with":[71],"regard":[72],"SLAs":[75],"energy-related":[78],"operational":[79],"cost":[80],"cloud":[83],"computing":[84],"infrastructure.":[85],"We":[86],"show":[87],"several":[88],"experiments":[89],"how":[90],"our":[91],"system":[92],"can":[93],"be":[94],"controlled":[95],"through":[96],"high":[97],"level":[98],"handles":[99],"make":[101],"different":[102],"trade-off":[103],"between":[104],"application":[105],"energy":[108],"or":[110],"arbitrate":[112],"allocations":[114],"in":[115],"case":[116],"contention.":[118]},"counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2024,"cited_by_count":1},{"year":2023,"cited_by_count":4},{"year":2022,"cited_by_count":6},{"year":2021,"cited_by_count":6},{"year":2020,"cited_by_count":10},{"year":2019,"cited_by_count":4},{"year":2018,"cited_by_count":17},{"year":2017,"cited_by_count":19},{"year":2016,"cited_by_count":18},{"year":2015,"cited_by_count":28},{"year":2014,"cited_by_count":9},{"year":2013,"cited_by_count":25},{"year":2012,"cited_by_count":13}],"updated_date":"2026-11-07T11:25:07.637180","created_date":"2016-06-24T00:00:00"}
