{"id":"https://openalex.org/W2007459312","doi":"https://doi.org/10.3182/20050703-6-cz-1902.02193","title":"AUTOMATIC COMBUSTION CONTROL FOR A GASIFYING AND DIRECT MELTING FURNACE","display_name":"AUTOMATIC COMBUSTION CONTROL FOR A GASIFYING AND DIRECT MELTING FURNACE","alternate_titles":[],"publication_year":2005,"publication_date":"2005-01-01","ids":{"openalex":"https://openalex.org/W2007459312","doi":"https://doi.org/10.3182/20050703-6-cz-1902.02193","mag":"2007459312"},"language":"en","primary_location":{"id":"doi:10.3182/20050703-6-cz-1902.02193","doi":"https://doi.org/10.3182/20050703-6-cz-1902.02193","is_oa":false,"landing_page_url":"https://doi.org/10.3182/20050703-6-cz-1902.02193","pdf_url":null,"source":{"id":"https://openalex.org/S2898246533","display_name":"IFAC Proceedings Volumes","issn_l":"1474-6670","issn":["1474-6670","2589-3653"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/P4310320990","host_organization_name":"Elsevier BV","host_organization_lineage":["https://openalex.org/P4310320990"],"host_organization_lineage_names":["Elsevier BV"],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IFAC Proceedings Volumes","raw_type":"journal-article"},"parent_works":[],"lineage":["https://openalex.org/W2007459312"],"child_works_count":0,"pull_notice_works":[],"type":"conference-paper","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5049920955","display_name":"Kazuro Tsuda","type":null,"orcid":null,"observed_orcids":[]},"acted_on_behalf_of":[],"institutions":[],"countries":[],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"Kazuro Tsuda","raw_affiliation_strings":["JFE R&D Corp. 1-1 Minami-Watarida-cho, Kawasaki-ku, Kawasaki 210-0855 JAPAN"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"JFE R&D Corp. 1-1 Minami-Watarida-cho, Kawasaki-ku, Kawasaki 210-0855 JAPAN","institution_ids":[]}]},{"author_position":"middle","author":{"id":null,"display_name":"Minoru Tanabe","type":null,"orcid":null,"observed_orcids":[]},"acted_on_behalf_of":[],"institutions":[],"countries":[],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"Minoru Tanabe","raw_affiliation_strings":["JFE R&D Corp. 1-1 Minami-Watarida-cho, Kawasaki-ku, Kawasaki 210-0855 JAPAN"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"JFE R&D Corp. 1-1 Minami-Watarida-cho, Kawasaki-ku, Kawasaki 210-0855 JAPAN","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5034419885","display_name":"\u5cf6\u672c\u62d3\u5e78","type":null,"orcid":null,"observed_orcids":[]},"acted_on_behalf_of":[],"institutions":[],"countries":[],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"Hiroyuki Shimamoto","raw_affiliation_strings":["JFE R&D Corp. 1-1 Minami-Watarida-cho, Kawasaki-ku, Kawasaki 210-0855 JAPAN"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"JFE R&D Corp. 1-1 Minami-Watarida-cho, Kawasaki-ku, Kawasaki 210-0855 JAPAN","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":1,"reviewed_by_count":0,"citation_normalized_percentile":{"value":0.0,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":88,"max":93},"biblio":{"volume":"38","issue":"1","first_page":"133","last_page":"138"},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10791","display_name":"Advanced Control Systems Optimization","score":0.9961000084877014,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10791","display_name":"Advanced Control Systems Optimization","score":0.9961000084877014,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13344","display_name":"Industrial Automation and Control Systems","score":0.0006000000284984708,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11108","display_name":"Municipal Solid Waste Management","score":0.00039999998989515007,"subfield":{"id":"https://openalex.org/subfields/2311","display_name":"Waste Management and Disposal"},"field":{"id":"https://openalex.org/fields/23","display_name":"Environmental Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/automatic-combustion-control","display_name":"automatic combustion control","score":0.8849999904632568},{"id":"https://openalex.org/keywords/waste-treatment","display_name":"waste treatment","score":0.7329999804496765},{"id":"https://openalex.org/keywords/recycling","display_name":"recycling","score":0.41200000047683716},{"id":"https://openalex.org/keywords/rule-based-control","display_name":"rule-based control","score":0.9819999933242798},{"id":"https://openalex.org/keywords/high-temperature-furnace","display_name":"high-temperature furnace","score":0.5740000009536743}],"concepts":[{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.543731689453125},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.5402059555053711},{"id":"https://openalex.org/C17500928","wikidata":"https://www.wikidata.org/wiki/Q959968","display_name":"Control system","level":2,"score":0.5118300318717957},{"id":"https://openalex.org/C105923489","wikidata":"https://www.wikidata.org/wiki/Q133235","display_name":"Combustion","level":2,"score":0.5008060932159424},{"id":"https://openalex.org/C21880701","wikidata":"https://www.wikidata.org/wiki/Q2144042","display_name":"Process engineering","level":1,"score":0.4527861475944519},{"id":"https://openalex.org/C167123822","wikidata":"https://www.wikidata.org/wiki/Q184199","display_name":"Automatic control","level":2,"score":0.4318607449531555},{"id":"https://openalex.org/C548081761","wikidata":"https://www.wikidata.org/wiki/Q180388","display_name":"Waste management","level":1,"score":0.4187335968017578},{"id":"https://openalex.org/C536315585","wikidata":"https://www.wikidata.org/wiki/Q7698332","display_name":"Temperature control","level":2,"score":0.41868042945861816},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.4132900834083557},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.2489010989665985},{"id":"https://openalex.org/C185592680","wikidata":"https://www.wikidata.org/wiki/Q2329","display_name":"Chemistry","level":0,"score":0.1597389578819275},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C178790620","wikidata":"https://www.wikidata.org/wiki/Q11351","display_name":"Organic chemistry","level":1,"score":0.0},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.3182/20050703-6-cz-1902.02193","doi":"https://doi.org/10.3182/20050703-6-cz-1902.02193","is_oa":false,"landing_page_url":"https://doi.org/10.3182/20050703-6-cz-1902.02193","pdf_url":null,"source":{"id":"https://openalex.org/S2898246533","display_name":"IFAC Proceedings Volumes","issn_l":"1474-6670","issn":["1474-6670","2589-3653"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/P4310320990","host_organization_name":"Elsevier BV","host_organization_lineage":["https://openalex.org/P4310320990"],"host_organization_lineage_names":["Elsevier BV"],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IFAC Proceedings Volumes","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Responsible consumption and production","id":"https://metadata.un.org/sdg/12","score":0.6000000238418579}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":3,"referenced_works":["https://openalex.org/W1976325957","https://openalex.org/W2306823843","https://openalex.org/W2521257797"],"related_works":["https://openalex.org/W2329579134","https://openalex.org/W4249937409","https://openalex.org/W7155023941","https://openalex.org/W2367982113","https://openalex.org/W66195477","https://openalex.org/W2885710368","https://openalex.org/W2898051293","https://openalex.org/W4385324608","https://openalex.org/W7165735936","https://openalex.org/W2326031203"],"abstract_inverted_index":null,"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W2007459312","counts_by_year":[{"year":2024,"cited_by_count":1}],"updated_date":"2026-11-21T10:27:49.728292","created_date":"2016-06-24T00:00:00"}
