{"id":"https://openalex.org/W2007268771","doi":"https://doi.org/10.1049/piee.1964.0137","title":"Developments in the design of large power transformers","display_name":"Developments in the design of large power transformers","alternate_titles":[],"publication_year":1964,"publication_date":"1964-01-01","ids":{"openalex":"https://openalex.org/W2007268771","doi":"https://doi.org/10.1049/piee.1964.0137","mag":"2007268771"},"language":"en","primary_location":{"id":"doi:10.1049/piee.1964.0137","doi":"https://doi.org/10.1049/piee.1964.0137","is_oa":false,"landing_page_url":"https://doi.org/10.1049/piee.1964.0137","pdf_url":null,"source":{"id":"https://openalex.org/S4210235475","display_name":"Proceedings of the Institution of Electrical Engineers","issn_l":"0020-3270","issn":["0020-3270","2053-7891"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/P4320800662","host_organization_name":"Institution of Electrical Engineers","host_organization_lineage":["https://openalex.org/P4320800662"],"host_organization_lineage_names":["Institution of Electrical Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the Institution of Electrical Engineers","raw_type":"journal-article"},"parent_works":[],"lineage":["https://openalex.org/W2007268771"],"child_works_count":0,"pull_notice_works":[],"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5049115687","display_name":"H.W. Kerr","type":null,"orcid":null,"observed_orcids":[]},"acted_on_behalf_of":[],"institutions":[],"countries":[],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"H.W. Kerr","raw_affiliation_strings":["Bruce Peebles and Co. Ltd., Croydon, UK"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Bruce Peebles and Co. Ltd., Croydon, UK","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5013257246","display_name":"Selwyn Palmer","type":null,"orcid":null,"observed_orcids":[]},"acted_on_behalf_of":[],"institutions":[],"countries":[],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"S. Palmer","raw_affiliation_strings":["Bruce Peebles and Co. Ltd., Croydon, UK"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Bruce Peebles and Co. Ltd., Croydon, UK","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":16,"reviewed_by_count":0,"citation_normalized_percentile":{"value":0.0,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":87,"max":96},"biblio":{"volume":"111","issue":"4","first_page":"823","last_page":"823"},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11222","display_name":"Magnetic Properties and Applications","score":0.8916000127792358,"subfield":{"id":"https://openalex.org/subfields/2504","display_name":"Electronic, Optical and Magnetic Materials"},"field":{"id":"https://openalex.org/fields/25","display_name":"Materials Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11222","display_name":"Magnetic Properties and Applications","score":0.8916000127792358,"subfield":{"id":"https://openalex.org/subfields/2504","display_name":"Electronic, Optical and Magnetic Materials"},"field":{"id":"https://openalex.org/fields/25","display_name":"Materials Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14502","display_name":"High-Voltage Power Transmission Systems","score":0.057999998331069946,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11343","display_name":"Power Transformer Diagnostics and Insulation","score":0.03819999843835831,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/large-power-transformers","display_name":"large power transformers","score":0.9580000042915344},{"id":"https://openalex.org/keywords/transformer-design","display_name":"transformer design","score":0.9639999866485596},{"id":"https://openalex.org/keywords/transformer-noise","display_name":"transformer noise","score":0.8949999809265137},{"id":"https://openalex.org/keywords/stray-load-losses","display_name":"stray load losses","score":0.8510000109672546},{"id":"https://openalex.org/keywords/transformer-rating","display_name":"transformer rating","score":0.34299999475479126}],"concepts":[{"id":"https://openalex.org/C66322947","wikidata":"https://www.wikidata.org/wiki/Q11658","display_name":"Transformer","level":3,"score":0.7447763681411743},{"id":"https://openalex.org/C9121194","wikidata":"https://www.wikidata.org/wiki/Q5377050","display_name":"Energy efficient transformer","level":5,"score":0.5643554925918579},{"id":"https://openalex.org/C117323899","wikidata":"https://www.wikidata.org/wiki/Q1907989","display_name":"Distribution transformer","level":4,"score":0.5045346021652222},{"id":"https://openalex.org/C47330980","wikidata":"https://www.wikidata.org/wiki/Q7834127","display_name":"Transformer types","level":5,"score":0.48813948035240173},{"id":"https://openalex.org/C138838965","wikidata":"https://www.wikidata.org/wiki/Q1258026","display_name":"Delta-wye transformer","level":5,"score":0.48163333535194397},{"id":"https://openalex.org/C180850520","wikidata":"https://www.wikidata.org/wiki/Q2166404","display_name":"Isolation transformer","level":4,"score":0.4692055583000183},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.4689827561378479},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.4447762668132782},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.37294113636016846},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.3559880554676056},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.35006260871887207},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.26415517926216125}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1049/piee.1964.0137","doi":"https://doi.org/10.1049/piee.1964.0137","is_oa":false,"landing_page_url":"https://doi.org/10.1049/piee.1964.0137","pdf_url":null,"source":{"id":"https://openalex.org/S4210235475","display_name":"Proceedings of the Institution of Electrical Engineers","issn_l":"0020-3270","issn":["0020-3270","2053-7891"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/P4320800662","host_organization_name":"Institution of Electrical Engineers","host_organization_lineage":["https://openalex.org/P4320800662"],"host_organization_lineage_names":["Institution of Electrical Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the Institution of Electrical Engineers","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Industry, innovation and infrastructure","id":"https://metadata.un.org/sdg/9","score":1.0}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":5,"referenced_works":["https://openalex.org/W1989466610","https://openalex.org/W1995177442","https://openalex.org/W2001132503","https://openalex.org/W2147184210","https://openalex.org/W7050706647"],"related_works":["https://openalex.org/W3107222530","https://openalex.org/W2050150428","https://openalex.org/W2011933587","https://openalex.org/W7046041907","https://openalex.org/W2049805886","https://openalex.org/W4226076772","https://openalex.org/W4414548284","https://openalex.org/W1538580185","https://openalex.org/W1823059811","https://openalex.org/W2020939119"],"abstract_inverted_index":{"Demands":[0],"for":[1,117,150,181],"greatly":[2],"increased":[3],"power":[4,145],"transformer":[5,16,64,98,173,184],"ratings":[6],"within":[7],"transport":[8,151],"limits":[9],"which":[10,24,142],"change":[11],"only":[12],"slowly":[13],"have":[14],"compelled":[15],"designers":[17,174],"to":[18,147,178],"devise":[19],"new":[20],"forms":[21],"of":[22,30,39,50,68,71,81,84,102,107,124,128,139],"construction":[23,54,141],"make":[25],"the":[26,69,97,126],"best":[27],"possible":[28],"use":[29,70],"materials.The":[31],"paper":[32],"illustrates":[33],"this":[34],"by":[35,169],"giving":[36],"an":[37,77],"account":[38,78,136],"some":[40,44],"design":[41],"problems":[42],"and":[43,55,66,76,105,120,152,162],"particular":[45],"solutions.":[46],"Details":[47],"are":[48,110,115,164],"given":[49,80,116],"a":[51,82,90,121,134,140,156],"boltless":[52],"core":[53],"its":[56],"effect":[57,127],"on":[58,63],"noise":[59],"level.":[60],"The":[61],"influence":[62],"size":[65],"losses":[67,95],"transposed-strip":[72],"conductor":[73],"is":[74,79,132,137,166],"discussed,":[75],"method":[83,123],"calculating":[85],"disc-winding":[86],"temperature":[87],"rise":[88],"with":[89],"digital":[91],"computer.":[92],"Stray":[93],"load":[94],"in":[96,154],"structure":[99],"can":[100],"be":[101,148,176],"considerable":[103],"magnitude,":[104],"methods":[106],"reducing":[108],"them":[109],"considered.":[111],"Some":[112],"test":[113],"results":[114],"core-clamp":[118],"losses,":[119],"simple":[122],"predicting":[125],"magnetic":[129],"tank":[130],"shields":[131],"described.Finally,":[133],"brief":[135],"included":[138],"allows":[143],"large":[144],"transformers":[146],"dismantled":[149],"reassembled":[153],"such":[155,171],"way":[157],"that":[158,168],"abnormal":[159],"site":[160],"testing":[161],"processing":[163],"avoided.It":[165],"concluded":[167],"all":[170],"means":[172],"will":[175],"able":[177],"meet":[179],"demands":[180],"still":[182],"greater":[183],"ratings.":[185]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W2007268771","counts_by_year":[{"year":2019,"cited_by_count":1},{"year":2015,"cited_by_count":1},{"year":2014,"cited_by_count":1},{"year":2013,"cited_by_count":3}],"updated_date":"2026-11-25T09:40:18.809321","created_date":"2016-06-24T00:00:00"}
