{"id":"https://openalex.org/W2007052002","doi":"https://doi.org/10.1109/amps.2010.5609323","title":"A fuzzy, metrology-sound approach for the identification of the sources injecting periodic disturbances in electric networks","display_name":"A fuzzy, metrology-sound approach for the identification of the sources injecting periodic disturbances in electric networks","publication_year":2010,"publication_date":"2010-09-01","ids":{"openalex":"https://openalex.org/W2007052002","doi":"https://doi.org/10.1109/amps.2010.5609323","mag":"2007052002"},"language":"en","primary_location":{"id":"doi:10.1109/amps.2010.5609323","doi":"https://doi.org/10.1109/amps.2010.5609323","is_oa":false,"landing_page_url":"https://doi.org/10.1109/amps.2010.5609323","pdf_url":null,"source":{"id":"https://openalex.org/S7407087192","display_name":"IEEE International Workshop on Applied Measurements for Power Systems (AMPS)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2010 IEEE International Workshop on Applied Measurements for Power Systems","raw_type":"proceedings-article"},"volume":null,"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5048123338","display_name":"Alessandro Ferrero","orcid":"https://orcid.org/0000-0002-6760-2925","observed_orcids":["https://orcid.org/0000-0002-6760-2925"]},"institutions":[{"id":"https://openalex.org/I93860229","display_name":"Politecnico di Milano","ror":"https://ror.org/01nffqt88","country_code":"IT","type":"education","lineage":["https://openalex.org/I93860229"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Alessandro Ferrero","raw_affiliation_strings":["Dipartimento di Elettrotecnica, Politecnico di Milano, Milan, Italy","Dipartimento di Elettrotecnica - Politecnico di Milano - Piazza Leonardo da Vinci 32 - 20133 - Italy"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Dipartimento di Elettrotecnica, Politecnico di Milano, Milan, Italy","institution_ids":["https://openalex.org/I93860229"]},{"raw_affiliation_string":"Dipartimento di Elettrotecnica - Politecnico di Milano - Piazza Leonardo da Vinci 32 - 20133 - Italy","institution_ids":["https://openalex.org/I93860229"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5011354690","display_name":"Marco Prioli","orcid":"https://orcid.org/0000-0003-4220-0812","observed_orcids":["https://orcid.org/0000-0003-4220-0812"]},"institutions":[{"id":"https://openalex.org/I93860229","display_name":"Politecnico di Milano","ror":"https://ror.org/01nffqt88","country_code":"IT","type":"education","lineage":["https://openalex.org/I93860229"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Marco Prioli","raw_affiliation_strings":["Dipartimento di Elettrotecnica, Politecnico di Milano, Milan, Italy","Dipartimento di Elettrotecnica - Politecnico di Milano - Piazza Leonardo da Vinci 32 - 20133 - Italy"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Dipartimento di Elettrotecnica, Politecnico di Milano, Milan, Italy","institution_ids":["https://openalex.org/I93860229"]},{"raw_affiliation_string":"Dipartimento di Elettrotecnica - Politecnico di Milano - Piazza Leonardo da Vinci 32 - 20133 - Italy","institution_ids":["https://openalex.org/I93860229"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5054803036","display_name":"Simona Salicone","orcid":"https://orcid.org/0000-0003-4683-7669","observed_orcids":["https://orcid.org/0000-0003-4683-7669"]},"institutions":[{"id":"https://openalex.org/I93860229","display_name":"Politecnico di Milano","ror":"https://ror.org/01nffqt88","country_code":"IT","type":"education","lineage":["https://openalex.org/I93860229"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Simona Salicone","raw_affiliation_strings":["Dipartimento di Elettrotecnica, Politecnico di Milano, Milan, Italy","Dipartimento di Elettrotecnica - Politecnico di Milano - Piazza Leonardo da Vinci 32 - 20133 - Italy"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Dipartimento di Elettrotecnica, Politecnico di Milano, Milan, Italy","institution_ids":["https://openalex.org/I93860229"]},{"raw_affiliation_string":"Dipartimento di Elettrotecnica - Politecnico di Milano - Piazza Leonardo da Vinci 32 - 20133 - Italy","institution_ids":["https://openalex.org/I93860229"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I93860229"],"apc_list":null,"apc_paid":null,"fwci":0.436,"has_fulltext":false,"cited_by_count":2,"citation_normalized_percentile":{"value":0.53304273,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":94},"biblio":{"volume":"2006","issue":null,"first_page":"64","last_page":"69"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10573","display_name":"Power Quality and Harmonics","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10573","display_name":"Power Quality and Harmonics","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12300","display_name":"Advanced Electrical Measurement Techniques","score":9.999999747378752e-05,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/power-quality","display_name":"power quality","score":0.6489999890327454},{"id":"https://openalex.org/keywords/harmonic-distortion","display_name":"harmonic distortion","score":0.8029999732971191},{"id":"https://openalex.org/keywords/periodic-disturbances","display_name":"periodic disturbances","score":0.7509999871253967},{"id":"https://openalex.org/keywords/source-identification","display_name":"source identification","score":0.7860000133514404},{"id":"https://openalex.org/keywords/fuzzy-inference-system","display_name":"fuzzy inference system","score":0.9869999885559082},{"id":"https://openalex.org/keywords/measurement-uncertainty","display_name":"measurement uncertainty","score":0.968999981880188},{"id":"https://openalex.org/keywords/metrology","display_name":"metrology","score":0.7540000081062317},{"id":"https://openalex.org/keywords/point-of-common-coupling","display_name":"point of common coupling","score":0.9589999914169312},{"id":"https://openalex.org/keywords/load-classification","display_name":"load classification","score":0.5149999856948853}],"concepts":[{"id":"https://openalex.org/C126780896","wikidata":"https://www.wikidata.org/wiki/Q899871","display_name":"Distortion (music)","level":4,"score":0.7431008219718933},{"id":"https://openalex.org/C58166","wikidata":"https://www.wikidata.org/wiki/Q224821","display_name":"Fuzzy logic","level":2,"score":0.6522970199584961},{"id":"https://openalex.org/C116834253","wikidata":"https://www.wikidata.org/wiki/Q2039217","display_name":"Identification (biology)","level":2,"score":0.6376733183860779},{"id":"https://openalex.org/C195766429","wikidata":"https://www.wikidata.org/wiki/Q394","display_name":"Metrology","level":2,"score":0.6098203063011169},{"id":"https://openalex.org/C173801870","wikidata":"https://www.wikidata.org/wiki/Q201413","display_name":"Heuristic","level":2,"score":0.6059966683387756},{"id":"https://openalex.org/C2987376176","wikidata":"https://www.wikidata.org/wiki/Q224821","display_name":"Fuzzy inference system","level":5,"score":0.5621856451034546},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5576655864715576},{"id":"https://openalex.org/C28719098","wikidata":"https://www.wikidata.org/wiki/Q44946","display_name":"Point (geometry)","level":2,"score":0.5127383470535278},{"id":"https://openalex.org/C2778160759","wikidata":"https://www.wikidata.org/wiki/Q1780079","display_name":"Electric power quality","level":4,"score":0.4977000057697296},{"id":"https://openalex.org/C137209882","wikidata":"https://www.wikidata.org/wiki/Q1403517","display_name":"Measurement uncertainty","level":2,"score":0.4578723907470703},{"id":"https://openalex.org/C2776214188","wikidata":"https://www.wikidata.org/wiki/Q408386","display_name":"Inference","level":2,"score":0.4347790777683258},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.38762468099594116},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.38715529441833496},{"id":"https://openalex.org/C195975749","wikidata":"https://www.wikidata.org/wiki/Q1475705","display_name":"Fuzzy control system","level":3,"score":0.3852495551109314},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.35855549573898315},{"id":"https://openalex.org/C186108316","wikidata":"https://www.wikidata.org/wiki/Q352530","display_name":"Adaptive neuro fuzzy inference system","level":4,"score":0.31014710664749146},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.2713744640350342},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.23518693447113037},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.09155938029289246},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.07313987612724304},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.06367817521095276},{"id":"https://openalex.org/C86803240","wikidata":"https://www.wikidata.org/wiki/Q420","display_name":"Biology","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C194257627","wikidata":"https://www.wikidata.org/wiki/Q211554","display_name":"Amplifier","level":3,"score":0.0},{"id":"https://openalex.org/C2776257435","wikidata":"https://www.wikidata.org/wiki/Q1576430","display_name":"Bandwidth (computing)","level":2,"score":0.0},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0},{"id":"https://openalex.org/C59822182","wikidata":"https://www.wikidata.org/wiki/Q441","display_name":"Botany","level":1,"score":0.0},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/amps.2010.5609323","doi":"https://doi.org/10.1109/amps.2010.5609323","is_oa":false,"landing_page_url":"https://doi.org/10.1109/amps.2010.5609323","pdf_url":null,"source":{"id":"https://openalex.org/S7407087192","display_name":"IEEE International Workshop on Applied Measurements for Power Systems (AMPS)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2010 IEEE International Workshop on Applied Measurements for Power Systems","raw_type":"proceedings-article"},{"id":"pmh:oai:re.public.polimi.it:11311/572396","doi":null,"is_oa":false,"landing_page_url":"http://hdl.handle.net/11311/572396","pdf_url":null,"source":{"id":"https://openalex.org/S4306400312","display_name":"Virtual Community of Pathological Anatomy (University of Castilla La Mancha)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I79189158","host_organization_name":"University of Castilla-La Mancha","host_organization_lineage":["https://openalex.org/I79189158"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"info:eu-repo/semantics/conferenceObject"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Industry, innovation and infrastructure","score":0.5378999710083008,"id":"https://metadata.un.org/sdg/9"}],"sustainable_development_goals_aurora":[],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":31,"referenced_works":["https://openalex.org/W50090256","https://openalex.org/W179611734","https://openalex.org/W564030374","https://openalex.org/W631056405","https://openalex.org/W1646783551","https://openalex.org/W1979074283","https://openalex.org/W1988041750","https://openalex.org/W1992176519","https://openalex.org/W2067967289","https://openalex.org/W2080056491","https://openalex.org/W2111357372","https://openalex.org/W2113535940","https://openalex.org/W2115886125","https://openalex.org/W2120052514","https://openalex.org/W2143184114","https://openalex.org/W2156406853","https://openalex.org/W2157882141","https://openalex.org/W2167935093","https://openalex.org/W2168736321","https://openalex.org/W2169543239","https://openalex.org/W2180159404","https://openalex.org/W2496338429","https://openalex.org/W2983127271","https://openalex.org/W2983338817","https://openalex.org/W2984092403","https://openalex.org/W2987011145","https://openalex.org/W4221050585","https://openalex.org/W4249749961","https://openalex.org/W4285719527","https://openalex.org/W7020613895","https://openalex.org/W7038519561"],"related_works":["https://openalex.org/W2181415496","https://openalex.org/W3199050383","https://openalex.org/W4322732584","https://openalex.org/W3015838480","https://openalex.org/W2477660228","https://openalex.org/W2922721683","https://openalex.org/W2943069943","https://openalex.org/W2382941854","https://openalex.org/W2889574165","https://openalex.org/W1980429525"],"abstract_inverted_index":{"The":[0,24,88],"identification":[1,78],"of":[2,19,79,106,110,124],"the":[3,9,17,20,77,80,113,122,125],"sources":[4,81],"injecting":[5,116],"periodic":[6,83],"disturbances":[7],"in":[8,16,64,85],"electric":[10,21],"systems":[11],"is":[12,115],"a":[13,29,48,65,71,104],"critical":[14],"point":[15],"assessment":[18],"Power":[22],"Quality.":[23],"available":[25],"methods,":[26],"based":[27,39,46],"on":[28,40,47],"deterministic":[30],"approach,":[31],"do":[32,56],"not":[33,57],"always":[34],"provide":[35,52],"correct":[36],"results.":[37],"Methods":[38],"heuristic":[41],"approaches,":[42],"such":[43],"as":[44],"those":[45],"Fuzzy":[49,73],"Inference":[50,74],"System,":[51],"better":[53],"results,":[54],"but":[55],"allow":[58],"measurement":[59,97],"uncertainty":[60],"to":[61,76,99,103],"be":[62],"evaluated":[63],"straightforward":[66],"way.":[67],"This":[68],"paper":[69],"applies":[70],"modified":[72],"System":[75],"producing":[82],"distortion":[84,119],"power":[86],"systems.":[87],"method":[89],"associates":[90],"an":[91],"index,":[92],"provided":[93],"together":[94],"with":[95],"its":[96],"uncertainty,":[98],"each":[100],"load":[101,114],"connected":[102],"Point":[105],"Common":[107],"Coupling,":[108],"capable":[109],"assessing":[111],"whether":[112],"or":[117,127],"suffering":[118],"and":[120],"quantifying":[121],"severity":[123],"injected":[126],"suffered":[128],"distortion.":[129]},"counts_by_year":[{"year":2019,"cited_by_count":1}],"updated_date":"2026-10-16T09:59:22.235173","created_date":"2025-10-10T00:00:00"}
