{"id":"https://openalex.org/W2005688635","doi":"https://doi.org/10.1109/tsg.2014.2380642","title":"Voltage Sensitivity Analysis of a Laboratory Distribution Grid With Incomplete Data","display_name":"Voltage Sensitivity Analysis of a Laboratory Distribution Grid With Incomplete Data","publication_year":2014,"publication_date":"2014-12-30","ids":{"openalex":"https://openalex.org/W2005688635","doi":"https://doi.org/10.1109/tsg.2014.2380642","mag":"2005688635"},"language":"en","primary_location":{"id":"doi:10.1109/tsg.2014.2380642","doi":"https://doi.org/10.1109/tsg.2014.2380642","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tsg.2014.2380642","pdf_url":null,"source":{"id":"https://openalex.org/S59604973","display_name":"IEEE Transactions on Smart Grid","issn_l":"1949-3053","issn":["1949-3053","1949-3061"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-b","jufo-3","norway-2","poland-200","russia-white-list-1","vabb-shw"],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Smart Grid","raw_type":"journal-article"},"volume":null,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"https://lirias.kuleuven.be/retrieve/3ae43b96-66d1-42ef-b8c2-5c49c5ace344","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5081550003","display_name":"Sam Weckx","orcid":"https://orcid.org/0000-0001-6983-495X","observed_orcids":["https://orcid.org/0000-0001-6983-495X"]},"institutions":[{"id":"https://openalex.org/I68522396","display_name":"Flemish Institute for Technological Research","ror":"https://ror.org/04gq0w522","country_code":"BE","type":"facility","lineage":["https://openalex.org/I68522396"]},{"id":"https://openalex.org/I99464096","display_name":"KU Leuven","ror":"https://ror.org/05f950310","country_code":"BE","type":"education","lineage":["https://openalex.org/I99464096"]}],"countries":["BE"],"is_corresponding":false,"raw_author_name":"Sam Weckx","raw_affiliation_strings":["Flemish Institute for Technological Research VITO, Mol, Belgium","Research Group ELECTA, Katholieke Universiteit Leuven, Leuven, Belgium"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Flemish Institute for Technological Research VITO, Mol, Belgium","institution_ids":["https://openalex.org/I68522396"]},{"raw_affiliation_string":"Research Group ELECTA, Katholieke Universiteit Leuven, Leuven, Belgium","institution_ids":["https://openalex.org/I99464096"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5081145804","display_name":"Reinhilde D\u2019hulst","orcid":"https://orcid.org/0000-0003-3444-6644","observed_orcids":["https://orcid.org/0000-0003-3444-6644"]},"institutions":[{"id":"https://openalex.org/I68522396","display_name":"Flemish Institute for Technological Research","ror":"https://ror.org/04gq0w522","country_code":"BE","type":"facility","lineage":["https://openalex.org/I68522396"]}],"countries":["BE"],"is_corresponding":false,"raw_author_name":"Reinhilde D'Hulst","raw_affiliation_strings":["Flemish Institute for VITO, Mol, Belgium"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Flemish Institute for VITO, Mol, Belgium","institution_ids":["https://openalex.org/I68522396"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5027002529","display_name":"Johan Driesen","orcid":"https://orcid.org/0000-0002-1025-0949","observed_orcids":["https://orcid.org/0000-0002-1025-0949"]},"institutions":[{"id":"https://openalex.org/I99464096","display_name":"KU Leuven","ror":"https://ror.org/05f950310","country_code":"BE","type":"education","lineage":["https://openalex.org/I99464096"]}],"countries":["BE"],"is_corresponding":false,"raw_author_name":"Johan Driesen","raw_affiliation_strings":["Research Group ELECTA, Katholieke Universiteit Leuven, Leuven, Belgium"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Research Group ELECTA, Katholieke Universiteit Leuven, Leuven, Belgium","institution_ids":["https://openalex.org/I99464096"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":{"value":2645,"currency":"USD","value_usd":2645},"apc_paid":null,"fwci":1.6216,"has_fulltext":true,"cited_by_count":67,"citation_normalized_percentile":{"value":0.83896597,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":88,"max":99},"biblio":{"volume":"6","issue":"3","first_page":"1271","last_page":"1280"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10454","display_name":"Optimal Power Flow Distribution","score":0.9848999977111816,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10454","display_name":"Optimal Power Flow Distribution","score":0.9848999977111816,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.004900000058114529,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12451","display_name":"Smart Grid and Power Systems","score":0.003599999938160181,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/voltage-sensitivity-analysis","display_name":"voltage sensitivity analysis","score":0.9139999747276306},{"id":"https://openalex.org/keywords/voltage-control","display_name":"voltage regulation","score":0.8180000185966492},{"id":"https://openalex.org/keywords/low-voltage-distribution-networks","display_name":"low-voltage distribution networks","score":0.7789999842643738},{"id":"https://openalex.org/keywords/smart-meter-data","display_name":"smart meter data","score":0.8809999823570251},{"id":"https://openalex.org/keywords/unbalanced-distribution-networks","display_name":"unbalanced distribution systems","score":0.7429999709129333},{"id":"https://openalex.org/keywords/voltage-management","display_name":"voltage management","score":0.5740000009536743},{"id":"https://openalex.org/keywords/distributed-generation","display_name":"distributed generation","score":0.9520000219345093},{"id":"https://openalex.org/keywords/electric-vehicles","display_name":"electric vehicles","score":0.9509999752044678},{"id":"https://openalex.org/keywords/reactive-power-consumption","display_name":"reactive power consumption","score":0.39399999380111694}],"concepts":[{"id":"https://openalex.org/C10558101","wikidata":"https://www.wikidata.org/wiki/Q689855","display_name":"Smart grid","level":2,"score":0.7299734354019165},{"id":"https://openalex.org/C2779510800","wikidata":"https://www.wikidata.org/wiki/Q1630602","display_name":"Smart meter","level":3,"score":0.6897745728492737},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.6505377292633057},{"id":"https://openalex.org/C21200559","wikidata":"https://www.wikidata.org/wiki/Q7451068","display_name":"Sensitivity (control systems)","level":2,"score":0.6303532123565674},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5824093818664551},{"id":"https://openalex.org/C199845137","wikidata":"https://www.wikidata.org/wiki/Q145490","display_name":"Network topology","level":2,"score":0.56122887134552},{"id":"https://openalex.org/C108755667","wikidata":"https://www.wikidata.org/wiki/Q1930258","display_name":"AC power","level":3,"score":0.5554439425468445},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.5399953722953796},{"id":"https://openalex.org/C184720557","wikidata":"https://www.wikidata.org/wiki/Q7825049","display_name":"Topology (electrical circuits)","level":2,"score":0.4955083131790161},{"id":"https://openalex.org/C128624480","wikidata":"https://www.wikidata.org/wiki/Q1504817","display_name":"Low voltage","level":3,"score":0.458842396736145},{"id":"https://openalex.org/C46529443","wikidata":"https://www.wikidata.org/wiki/Q7940750","display_name":"Voltage optimisation","level":4,"score":0.4474390745162964},{"id":"https://openalex.org/C196226539","wikidata":"https://www.wikidata.org/wiki/Q7940752","display_name":"Voltage regulation","level":3,"score":0.4247400462627411},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.3855644464492798},{"id":"https://openalex.org/C120314980","wikidata":"https://www.wikidata.org/wiki/Q180634","display_name":"Distributed computing","level":1,"score":0.3286883234977722},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2813207507133484},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.21481719613075256},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.12309637665748596},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/tsg.2014.2380642","doi":"https://doi.org/10.1109/tsg.2014.2380642","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tsg.2014.2380642","pdf_url":null,"source":{"id":"https://openalex.org/S59604973","display_name":"IEEE Transactions on Smart Grid","issn_l":"1949-3053","issn":["1949-3053","1949-3061"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-b","jufo-3","norway-2","poland-200","russia-white-list-1","vabb-shw"],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Smart Grid","raw_type":"journal-article"},{"id":"pmh:oai:lirias2repo.kuleuven.be:123456789/476297","doi":null,"is_oa":true,"landing_page_url":"https://lirias.kuleuven.be/handle/123456789/476297","pdf_url":"https://lirias.kuleuven.be/retrieve/3ae43b96-66d1-42ef-b8c2-5c49c5ace344","source":{"id":"https://openalex.org/S4306401954","display_name":"Lirias (KU Leuven)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I99464096","host_organization_name":"KU Leuven","host_organization_lineage":["https://openalex.org/I99464096"],"host_organization_lineage_names":[],"type":"repository"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"IEEE Transactions on Smart Grid, vol. 6 (3), Art.No. 3, (1271-1280)","raw_type":"info:eu-repo/semantics/article"}],"best_oa_location":{"id":"pmh:oai:lirias2repo.kuleuven.be:123456789/476297","doi":null,"is_oa":true,"landing_page_url":"https://lirias.kuleuven.be/handle/123456789/476297","pdf_url":"https://lirias.kuleuven.be/retrieve/3ae43b96-66d1-42ef-b8c2-5c49c5ace344","source":{"id":"https://openalex.org/S4306401954","display_name":"Lirias (KU Leuven)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I99464096","host_organization_name":"KU Leuven","host_organization_lineage":["https://openalex.org/I99464096"],"host_organization_lineage_names":[],"type":"repository"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"IEEE Transactions on Smart Grid, vol. 6 (3), Art.No. 3, (1271-1280)","raw_type":"info:eu-repo/semantics/article"},"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","score":0.9090999960899353,"display_name":"Affordable and clean energy"},{"id":"https://metadata.un.org/sdg/9","score":0.8970999717712402,"display_name":"Industry, innovation and infrastructure"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":true,"grobid_xml":true},"content_urls":{"pdf":"https://content.openalex.org/works/W2005688635.pdf","grobid_xml":"https://content.openalex.org/works/W2005688635.grobid-xml"},"referenced_works_count":50,"referenced_works":["https://openalex.org/W1482925075","https://openalex.org/W1604973446","https://openalex.org/W1651162638","https://openalex.org/W1967428359","https://openalex.org/W1982446626","https://openalex.org/W1991102187","https://openalex.org/W1991631960","https://openalex.org/W1992598142","https://openalex.org/W1993196546","https://openalex.org/W2010456034","https://openalex.org/W2014798826","https://openalex.org/W2017407034","https://openalex.org/W2017564465","https://openalex.org/W2036360413","https://openalex.org/W2036548349","https://openalex.org/W2039211700","https://openalex.org/W2040647733","https://openalex.org/W2047745354","https://openalex.org/W2052447206","https://openalex.org/W2053403930","https://openalex.org/W2067892551","https://openalex.org/W2077975625","https://openalex.org/W2087895221","https://openalex.org/W2098659406","https://openalex.org/W2100682478","https://openalex.org/W2104179704","https://openalex.org/W2104424294","https://openalex.org/W2105957522","https://openalex.org/W2107486937","https://openalex.org/W2108713391","https://openalex.org/W2116544781","https://openalex.org/W2117694563","https://openalex.org/W2121848262","https://openalex.org/W2133937059","https://openalex.org/W2135020035","https://openalex.org/W2136080507","https://openalex.org/W2136700349","https://openalex.org/W2143022361","https://openalex.org/W2149189103","https://openalex.org/W2153425690","https://openalex.org/W2165738459","https://openalex.org/W2165814981","https://openalex.org/W2291508159","https://openalex.org/W2296319761","https://openalex.org/W2310747195","https://openalex.org/W2526873285","https://openalex.org/W2551921903","https://openalex.org/W3118220005","https://openalex.org/W4285719527","https://openalex.org/W6696897760"],"related_works":["https://openalex.org/W3033024428","https://openalex.org/W2990137450","https://openalex.org/W4411233725","https://openalex.org/W2511772924","https://openalex.org/W7097913630","https://openalex.org/W7166653056","https://openalex.org/W2999154371","https://openalex.org/W2075816026","https://openalex.org/W4413125668","https://openalex.org/W2562922400"],"abstract_inverted_index":{"New":[0],"voltage":[1,26,36,68,151,155],"control":[2,27],"algorithms":[3,28],"are":[4,29,48],"necessary":[5],"to":[6,61,86,109,126,140],"cope":[7],"with":[8],"the":[9,23,35,39,62,101,110,115,142,149,161],"increasing":[10],"amount":[11],"of":[12,22,66,133],"distributed":[13],"generation":[14],"and":[15,38,41,123],"electric":[16],"vehicles":[17],"in":[18,114,145],"distribution":[19,70,130],"networks.":[20],"Many":[21],"newly":[24],"proposed":[25,143],"based":[30,91],"on":[31,55,92],"linearized":[32,46],"dependencies":[33,47,90],"between":[34],"magnitude,":[37],"active":[40],"reactive":[42],"power":[43],"consumption.":[44],"These":[45],"normally":[49],"obtained":[50,150],"by":[51],"algorithms,":[52],"which":[53],"rely":[54],"accurate":[56],"grid":[57,102],"topology":[58,103],"information.":[59],"Due":[60],"traditionally":[63],"passive":[64],"operation":[65],"low":[67,121],"(LV)":[69],"networks,":[71],"this":[72,81],"information":[73,99],"is":[74,104,124,138],"typically":[75],"missing,":[76],"incomplete,":[77],"or":[78],"inaccurate.":[79],"Therefore,":[80],"paper":[82],"introduces":[83],"a":[84,120,134,154],"method":[85,144],"extract":[87],"these":[88],"linear":[89],"historical":[93],"smart":[94],"meter":[95],"data":[96],"only.":[97],"No":[98],"about":[100],"required.":[105],"The":[106,117],"model":[107],"adapts":[108],"changing":[111],"load":[112],"conditions":[113],"network.":[116,131],"algorithm":[118],"has":[119],"complexity":[122],"applied":[125],"an":[127],"unbalanced":[128],"LV":[129],"Data":[132],"practical":[135],"laboratory":[136,162],"setup":[137],"used":[139],"validate":[141],"real-life":[146],"conditions.":[147],"With":[148],"sensitivity":[152],"factors":[153],"management":[156],"strategy":[157],"was":[158],"implemented":[159],"for":[160],"grid.":[163]},"counts_by_year":[{"year":2026,"cited_by_count":3},{"year":2025,"cited_by_count":7},{"year":2024,"cited_by_count":5},{"year":2023,"cited_by_count":7},{"year":2022,"cited_by_count":5},{"year":2021,"cited_by_count":7},{"year":2020,"cited_by_count":8},{"year":2019,"cited_by_count":6},{"year":2018,"cited_by_count":9},{"year":2017,"cited_by_count":5},{"year":2016,"cited_by_count":4},{"year":2015,"cited_by_count":1}],"updated_date":"2026-11-07T11:25:07.637180","created_date":"2016-06-24T00:00:00"}
