{"id":"https://openalex.org/W2005284859","doi":"https://doi.org/10.1115/1.4002861","title":"Research and Application of Risk Assessment Methodology for Power Station Boiler Superheaters","display_name":"Research and Application of Risk Assessment Methodology for Power Station Boiler Superheaters","publication_year":2011,"publication_date":"2011-05-18","ids":{"openalex":"https://openalex.org/W2005284859","doi":"https://doi.org/10.1115/1.4002861","mag":"2005284859"},"language":"en","primary_location":{"id":"doi:10.1115/1.4002861","doi":"https://doi.org/10.1115/1.4002861","is_oa":false,"landing_page_url":"https://doi.org/10.1115/1.4002861","pdf_url":null,"source":{"id":"https://openalex.org/S166541267","display_name":"Journal of Pressure Vessel Technology","issn_l":"0094-9930","issn":["0094-9930","1528-8978"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-c","jufo-1","norway-1","poland-70","russia-white-list-3"],"host_organization":"https://openalex.org/P4310316053","host_organization_name":"ASM International","host_organization_lineage":["https://openalex.org/P4310316053"],"host_organization_lineage_names":["ASM International"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Journal of Pressure Vessel Technology","raw_type":"journal-article"},"volume":null,"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5100641993","display_name":"Fujun Liu","orcid":"https://orcid.org/0009-0008-7930-1071","observed_orcids":["https://orcid.org/0009-0008-7930-1071"]},"institutions":[{"id":"https://openalex.org/I4210115152","display_name":"Zhejiang Institute of Special Equipment Inspection","ror":"https://ror.org/01jb3sz14","country_code":"CN","type":"facility","lineage":["https://openalex.org/I4210115152"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Fujun Liu","raw_affiliation_strings":["Zhejiang Provincial Special Equipment Inspection and Research Institute, No. 211 Kaixuan Road, Hangzhou, Zhejiang 310020, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Zhejiang Provincial Special Equipment Inspection and Research Institute, No. 211 Kaixuan Road, Hangzhou, Zhejiang 310020, China","institution_ids":["https://openalex.org/I4210115152"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5008780253","display_name":"Shuai Kong","orcid":"https://orcid.org/0009-0001-2610-0590","observed_orcids":["https://orcid.org/0009-0001-2610-0590"]},"institutions":[{"id":"https://openalex.org/I4210115152","display_name":"Zhejiang Institute of Special Equipment Inspection","ror":"https://ror.org/01jb3sz14","country_code":"CN","type":"facility","lineage":["https://openalex.org/I4210115152"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Shuai Kong","raw_affiliation_strings":["Zhejiang Provincial Special Equipment Inspection and Research Institute, No. 211 Kaixuan Road, Hangzhou, Zhejiang 310020, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Zhejiang Provincial Special Equipment Inspection and Research Institute, No. 211 Kaixuan Road, Hangzhou, Zhejiang 310020, China","institution_ids":["https://openalex.org/I4210115152"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5066080850","display_name":"Zhangwei Ling","orcid":"https://orcid.org/0009-0006-0625-8362","observed_orcids":["https://orcid.org/0009-0006-0625-8362"]},"institutions":[{"id":"https://openalex.org/I4210115152","display_name":"Zhejiang Institute of Special Equipment Inspection","ror":"https://ror.org/01jb3sz14","country_code":"CN","type":"facility","lineage":["https://openalex.org/I4210115152"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Zhangwei Ling","raw_affiliation_strings":["Zhejiang Provincial Special Equipment Inspection and Research Institute, No. 211 Kaixuan Road, Hangzhou, Zhejiang 310020, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Zhejiang Provincial Special Equipment Inspection and Research Institute, No. 211 Kaixuan Road, Hangzhou, Zhejiang 310020, China","institution_ids":["https://openalex.org/I4210115152"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100429941","display_name":"Qiang Li","orcid":"https://orcid.org/0000-0002-1484-7611","observed_orcids":["https://orcid.org/0000-0002-1484-7611"]},"institutions":[{"id":"https://openalex.org/I4210115152","display_name":"Zhejiang Institute of Special Equipment Inspection","ror":"https://ror.org/01jb3sz14","country_code":"CN","type":"facility","lineage":["https://openalex.org/I4210115152"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Qiang Li","raw_affiliation_strings":["Zhejiang Provincial Special Equipment Inspection and Research Institute, No. 211 Kaixuan Road, Hangzhou, Zhejiang 310020, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Zhejiang Provincial Special Equipment Inspection and Research Institute, No. 211 Kaixuan Road, Hangzhou, Zhejiang 310020, China","institution_ids":["https://openalex.org/I4210115152"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5075594712","display_name":"Yueqiang Qian","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4210115152","display_name":"Zhejiang Institute of Special Equipment Inspection","ror":"https://ror.org/01jb3sz14","country_code":"CN","type":"facility","lineage":["https://openalex.org/I4210115152"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Yueqiang Qian","raw_affiliation_strings":["Zhejiang Provincial Special Equipment Inspection and Research Institute, No. 211 Kaixuan Road, Hangzhou, Zhejiang 310020, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Zhejiang Provincial Special Equipment Inspection and Research Institute, No. 211 Kaixuan Road, Hangzhou, Zhejiang 310020, China","institution_ids":["https://openalex.org/I4210115152"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5109137633","display_name":"Mulin Zheng","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4210115152","display_name":"Zhejiang Institute of Special Equipment Inspection","ror":"https://ror.org/01jb3sz14","country_code":"CN","type":"facility","lineage":["https://openalex.org/I4210115152"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Mulin Zheng","raw_affiliation_strings":["Zhejiang Provincial Special Equipment Inspection and Research Institute, No. 211 Kaixuan Road, Hangzhou, Zhejiang 310020, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Zhejiang Provincial Special Equipment Inspection and Research Institute, No. 211 Kaixuan Road, Hangzhou, Zhejiang 310020, China","institution_ids":["https://openalex.org/I4210115152"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I4210115152"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":2,"citation_normalized_percentile":{"value":0.18213681,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":94},"biblio":{"volume":"133","issue":"4","first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T12086","display_name":"Structural Integrity and Reliability Analysis","score":0.8666999936103821,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12086","display_name":"Structural Integrity and Reliability Analysis","score":0.8666999936103821,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10780","display_name":"Reliability and Maintenance Optimization","score":0.04520000144839287,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13891","display_name":"Engineering Diagnostics and Reliability","score":0.022600000724196434,"subfield":{"id":"https://openalex.org/subfields/2211","display_name":"Mechanics of Materials"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/risk-based-inspection","display_name":"risk-based inspection","score":0.9959999918937683},{"id":"https://openalex.org/keywords/power-plant-boilers","display_name":"power plant boilers","score":0.9660000205039978},{"id":"https://openalex.org/keywords/superheater","display_name":"superheater","score":0.753000020980835},{"id":"https://openalex.org/keywords/boiler-tube-failure","display_name":"boiler tube failure","score":0.6359999775886536},{"id":"https://openalex.org/keywords/api-581","display_name":"API 581","score":0.800000011920929},{"id":"https://openalex.org/keywords/high-temperature-creep","display_name":"high-temperature creep","score":0.9309999942779541},{"id":"https://openalex.org/keywords/remaining-life","display_name":"remaining life","score":0.734000027179718},{"id":"https://openalex.org/keywords/risk-assessment","display_name":"risk assessment","score":0.6019999980926514},{"id":"https://openalex.org/keywords/economizer","display_name":"economizer","score":0.6650000214576721},{"id":"https://openalex.org/keywords/reheater","display_name":"reheater","score":0.871999979019165},{"id":"https://openalex.org/keywords/unplanned-shutdowns","display_name":"unplanned shutdowns","score":0.796999990940094}],"concepts":[{"id":"https://openalex.org/C47561241","wikidata":"https://www.wikidata.org/wiki/Q332512","display_name":"Superheater","level":3,"score":0.8446210622787476},{"id":"https://openalex.org/C2780013297","wikidata":"https://www.wikidata.org/wiki/Q19596153","display_name":"Boiler (water heating)","level":2,"score":0.6325616836547852},{"id":"https://openalex.org/C41004858","wikidata":"https://www.wikidata.org/wiki/Q1389702","display_name":"Economizer","level":3,"score":0.5730088949203491},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.517173707485199},{"id":"https://openalex.org/C4311470","wikidata":"https://www.wikidata.org/wiki/Q159719","display_name":"Power station","level":2,"score":0.4899410605430603},{"id":"https://openalex.org/C2780263472","wikidata":"https://www.wikidata.org/wiki/Q331902","display_name":"Shutdown","level":2,"score":0.4605201482772827},{"id":"https://openalex.org/C77595967","wikidata":"https://www.wikidata.org/wiki/Q3151013","display_name":"Forensic engineering","level":1,"score":0.45315787196159363},{"id":"https://openalex.org/C170573351","wikidata":"https://www.wikidata.org/wiki/Q1364904","display_name":"Petrochemical","level":2,"score":0.4343739151954651},{"id":"https://openalex.org/C12174686","wikidata":"https://www.wikidata.org/wiki/Q1058438","display_name":"Risk assessment","level":2,"score":0.4217323064804077},{"id":"https://openalex.org/C2039551","wikidata":"https://www.wikidata.org/wiki/Q200297","display_name":"Thermal power station","level":2,"score":0.41706860065460205},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.3874157667160034},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.37182313203811646},{"id":"https://openalex.org/C548081761","wikidata":"https://www.wikidata.org/wiki/Q180388","display_name":"Waste management","level":1,"score":0.33862990140914917},{"id":"https://openalex.org/C116915560","wikidata":"https://www.wikidata.org/wiki/Q83504","display_name":"Nuclear engineering","level":1,"score":0.21713659167289734},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.17197468876838684},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.15474626421928406},{"id":"https://openalex.org/C107706546","wikidata":"https://www.wikidata.org/wiki/Q189124","display_name":"Heat exchanger","level":2,"score":0.1155133843421936},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.0},{"id":"https://openalex.org/C38652104","wikidata":"https://www.wikidata.org/wiki/Q3510521","display_name":"Computer security","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1115/1.4002861","doi":"https://doi.org/10.1115/1.4002861","is_oa":false,"landing_page_url":"https://doi.org/10.1115/1.4002861","pdf_url":null,"source":{"id":"https://openalex.org/S166541267","display_name":"Journal of Pressure Vessel Technology","issn_l":"0094-9930","issn":["0094-9930","1528-8978"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-c","jufo-1","norway-1","poland-70","russia-white-list-3"],"host_organization":"https://openalex.org/P4310316053","host_organization_name":"ASM International","host_organization_lineage":["https://openalex.org/P4310316053"],"host_organization_lineage_names":["ASM International"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Journal of Pressure Vessel Technology","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.7207000255584717,"display_name":"Industry, innovation and infrastructure","id":"https://metadata.un.org/sdg/9"},{"score":0.5690000057220459,"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":26,"referenced_works":["https://openalex.org/W1592176596","https://openalex.org/W1975976184","https://openalex.org/W1979437798","https://openalex.org/W1983630076","https://openalex.org/W1986278291","https://openalex.org/W1988734994","https://openalex.org/W1991760179","https://openalex.org/W1998734695","https://openalex.org/W2000231775","https://openalex.org/W2002215740","https://openalex.org/W2003519080","https://openalex.org/W2011138748","https://openalex.org/W2018045193","https://openalex.org/W2031755860","https://openalex.org/W2031768921","https://openalex.org/W2032325160","https://openalex.org/W2036946266","https://openalex.org/W2038806514","https://openalex.org/W2055135675","https://openalex.org/W2064120615","https://openalex.org/W2075570053","https://openalex.org/W2097861361","https://openalex.org/W2128249585","https://openalex.org/W2168977587","https://openalex.org/W4240635358","https://openalex.org/W7046434522"],"related_works":["https://openalex.org/W1963896135","https://openalex.org/W2358753978","https://openalex.org/W4320029928","https://openalex.org/W2371245975","https://openalex.org/W3112321131","https://openalex.org/W238057944","https://openalex.org/W655428591","https://openalex.org/W1965256594","https://openalex.org/W3015205521","https://openalex.org/W2775280191"],"abstract_inverted_index":{"Risk-based":[0],"inspection":[1],"(RBI)":[2],"has":[3,36,76,134],"been":[4,39,98,111,135,143,158],"applied":[5],"to":[6,11,23,32,61,64,173],"good":[7],"effect":[8],"in":[9,17,117],"relation":[10],"pieces":[12],"of":[13,26,30,43,93,151,171],"equipment":[14],"and":[15,56,75,100,106,123],"pipelines":[16],"the":[18,24,44,49,51,54,57,82,90,101,148,152,169],"petrochemical":[19],"industry":[20],"worldwide,":[21],"but":[22],"best":[25],"our":[27],"knowledge":[28],"application":[29,170],"RBI":[31,172],"power":[33,94,174],"station":[34,95,175],"boilers":[35,96],"not":[37],"hitherto":[38],"reported.":[40],"The":[41,160],"tubes":[42],"four":[45],"key":[46],"components,":[47],"namely,":[48],"economizer,":[50],"water-cooling":[52],"wall,":[53],"superheater,":[55],"reheater,":[58],"are":[59],"prone":[60],"blast":[62,70],"due":[63],"direct":[65],"fire":[66],"heating.":[67],"Such":[68],"a":[69,126],"always":[71],"causes":[72],"unplanned":[73],"shutdown":[74],"severe":[77],"safety":[78],"implications.":[79],"Based":[80],"on":[81,131],"\u201cAPI":[83],"581-2000\u201d":[84],"code":[85],"(Risk-Based":[86],"Inspection":[87],"Base":[88],"Resource),":[89],"failure":[91,127],"mechanisms":[92],"have":[97,110,142,157],"studied,":[99],"high-temperature":[102,107],"smoke":[103],"erosion":[104],"factor":[105,109,129],"creep":[108],"calculated.":[112],"Then,":[113],"considering":[114],"specific":[115],"situations":[116],"China,":[118],"such":[119],"as":[120],"material":[121],"quality":[122],"extended":[124],"service,":[125],"modification":[128],"based":[130],"remaining":[132],"life":[133],"proposed.":[136,159],"Finally,":[137],"two":[138],"risk":[139,149],"assessment":[140],"projects":[141],"carried":[144],"out;":[145],"after":[146],"delineating":[147],"levels":[150],"tubes,":[153],"appropriate":[154],"management":[155],"suggestions":[156],"obtained":[161],"data":[162],"should":[163],"provide":[164],"some":[165],"technical":[166],"support":[167],"for":[168],"boilers.":[176]},"counts_by_year":[{"year":2017,"cited_by_count":1},{"year":2016,"cited_by_count":1}],"updated_date":"2026-10-19T09:35:57.686232","created_date":"2016-06-24T00:00:00"}
