{"id":"https://openalex.org/W2004693522","doi":"https://doi.org/10.1177/1744259114546282","title":"Experimental study of the cooling performance of a ventilated wall","display_name":"Experimental study of the cooling performance of a ventilated wall","publication_year":2014,"publication_date":"2014-08-12","ids":{"openalex":"https://openalex.org/W2004693522","doi":"https://doi.org/10.1177/1744259114546282","mag":"2004693522"},"language":"en","primary_location":{"id":"doi:10.1177/1744259114546282","doi":"https://doi.org/10.1177/1744259114546282","is_oa":false,"landing_page_url":"https://doi.org/10.1177/1744259114546282","pdf_url":null,"source":{"id":"https://openalex.org/S140027543","display_name":"Journal of Building Physics","issn_l":"1097-1963","issn":["1097-1963","1530-8073","1744-2583","1744-2591"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["anvur-class-a","anvur-scientific","cwts-core","dongbi-c","jufo-2","norway-1","norway-2","poland-100","russia-white-list-1","vabb-shw"],"host_organization":"https://openalex.org/P4310320017","host_organization_name":"SAGE Publishing","host_organization_lineage":["https://openalex.org/P4310320017"],"host_organization_lineage_names":["SAGE Publishing"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Journal of Building Physics","raw_type":"journal-article"},"volume":null,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5090987938","display_name":"A. Dimoudi","orcid":"https://orcid.org/0000-0002-0074-7951","observed_orcids":["https://orcid.org/0000-0002-0074-7951"]},"institutions":[{"id":"https://openalex.org/I147962203","display_name":"Democritus University of Thrace","ror":"https://ror.org/03bfqnx40","country_code":"GR","type":"education","lineage":["https://openalex.org/I147962203"]}],"countries":["GR"],"is_corresponding":false,"raw_author_name":"Argiro C Dimoudi","raw_affiliation_strings":["Department of Environmental Engineering, Democritus University of Thrace, Xanthi, Greece","1Department of Environmental Engineering, Democritus University of Thrace, Xanthi, Greece"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Environmental Engineering, Democritus University of Thrace, Xanthi, Greece","institution_ids":["https://openalex.org/I147962203"]},{"raw_affiliation_string":"1Department of Environmental Engineering, Democritus University of Thrace, Xanthi, Greece","institution_ids":["https://openalex.org/I147962203"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5031793174","display_name":"Andreas Androutsopoulos","orcid":"https://orcid.org/0009-0005-1537-1386","observed_orcids":["https://orcid.org/0009-0005-1537-1386"]},"institutions":[{"id":"https://openalex.org/I4210130196","display_name":"Center for Renewable Energy Sources and Saving","ror":"https://ror.org/02ev1p206","country_code":"GR","type":"government","lineage":["https://openalex.org/I4210130196"]}],"countries":["GR"],"is_corresponding":false,"raw_author_name":"Andreas V Androutsopoulos","raw_affiliation_strings":["Buildings Department, Centre for Renewable Energy Sources and Saving (CRES), Pikermi, Greece","2Buildings Department, Centre for Renewable Energy Sources and Saving (CRES), Pikermi, Greece"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Buildings Department, Centre for Renewable Energy Sources and Saving (CRES), Pikermi, Greece","institution_ids":["https://openalex.org/I4210130196"]},{"raw_affiliation_string":"2Buildings Department, Centre for Renewable Energy Sources and Saving (CRES), Pikermi, Greece","institution_ids":["https://openalex.org/I4210130196"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5073777258","display_name":"Spyridon P. Lykoudis","orcid":"https://orcid.org/0000-0002-6473-2548","observed_orcids":["https://orcid.org/0000-0002-6473-2548"]},"institutions":[{"id":"https://openalex.org/I4210118731","display_name":"National Observatory of Athens","ror":"https://ror.org/03dtebk39","country_code":"GR","type":"facility","lineage":["https://openalex.org/I4210118731"]}],"countries":["GR"],"is_corresponding":false,"raw_author_name":"Spyros P Lykoudis","raw_affiliation_strings":["Institute for Environmental Research and Sustainable Development, National Observatory of Athens, Athens, Greece","3Institute for Environmental Research and Sustainable Development, National Observatory of Athens, Athens, Greece"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Institute for Environmental Research and Sustainable Development, National Observatory of Athens, Athens, Greece","institution_ids":["https://openalex.org/I4210118731"]},{"raw_affiliation_string":"3Institute for Environmental Research and Sustainable Development, National Observatory of Athens, Athens, Greece","institution_ids":["https://openalex.org/I4210118731"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":{"value":4150,"currency":"USD","value_usd":4150},"apc_paid":null,"fwci":1.0522,"has_fulltext":false,"cited_by_count":11,"citation_normalized_percentile":{"value":0.81160042,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":88,"max":97},"biblio":{"volume":"39","issue":"4","first_page":"297","last_page":"320"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.492900013923645,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.492900013923645,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13298","display_name":"Solar Energy Systems and Technologies","score":0.3677000105381012,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13263","display_name":"Building energy efficiency and sustainability","score":0.0843999981880188,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/ventilated-facade","display_name":"ventilated facade","score":0.8610000014305115},{"id":"https://openalex.org/keywords/cooling-load-reduction","display_name":"cooling load reduction","score":0.5870000123977661},{"id":"https://openalex.org/keywords/radiant-barrier","display_name":"radiant barrier","score":0.8289999961853027},{"id":"https://openalex.org/keywords/mechanical-ventilation","display_name":"mechanical ventilation","score":0.7990000247955322},{"id":"https://openalex.org/keywords/natural-ventilation","display_name":"natural ventilation","score":0.984000027179718},{"id":"https://openalex.org/keywords/building-energy-conservation","display_name":"building energy conservation","score":0.7670000195503235}],"concepts":[{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.5570293664932251},{"id":"https://openalex.org/C204530211","wikidata":"https://www.wikidata.org/wiki/Q752823","display_name":"Thermal","level":2,"score":0.5386289358139038},{"id":"https://openalex.org/C200457457","wikidata":"https://www.wikidata.org/wiki/Q584049","display_name":"Ventilation (architecture)","level":2,"score":0.5247535705566406},{"id":"https://openalex.org/C201289731","wikidata":"https://www.wikidata.org/wiki/Q1172599","display_name":"Inlet","level":2,"score":0.5173489451408386},{"id":"https://openalex.org/C79795727","wikidata":"https://www.wikidata.org/wiki/Q3068508","display_name":"Passive cooling","level":3,"score":0.5088999271392822},{"id":"https://openalex.org/C2781099182","wikidata":"https://www.wikidata.org/wiki/Q24963825","display_name":"Cooling load","level":3,"score":0.49036669731140137},{"id":"https://openalex.org/C133913538","wikidata":"https://www.wikidata.org/wiki/Q774514","display_name":"Thermal comfort","level":2,"score":0.48836442828178406},{"id":"https://openalex.org/C206018219","wikidata":"https://www.wikidata.org/wiki/Q1427418","display_name":"Natural ventilation","level":3,"score":0.4850589334964752},{"id":"https://openalex.org/C20564796","wikidata":"https://www.wikidata.org/wiki/Q1428108","display_name":"Room air distribution","level":2,"score":0.42187440395355225},{"id":"https://openalex.org/C2777087718","wikidata":"https://www.wikidata.org/wiki/Q17155651","display_name":"Radiant cooling","level":2,"score":0.41250842809677124},{"id":"https://openalex.org/C116915560","wikidata":"https://www.wikidata.org/wiki/Q83504","display_name":"Nuclear engineering","level":1,"score":0.38869258761405945},{"id":"https://openalex.org/C66938386","wikidata":"https://www.wikidata.org/wiki/Q633538","display_name":"Structural engineering","level":1,"score":0.3745536208152771},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.3558739423751831},{"id":"https://openalex.org/C103742991","wikidata":"https://www.wikidata.org/wiki/Q173725","display_name":"Air conditioning","level":2,"score":0.305749773979187},{"id":"https://openalex.org/C153294291","wikidata":"https://www.wikidata.org/wiki/Q25261","display_name":"Meteorology","level":1,"score":0.28653037548065186},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.2597614526748657},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.24844852089881897},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1177/1744259114546282","doi":"https://doi.org/10.1177/1744259114546282","is_oa":false,"landing_page_url":"https://doi.org/10.1177/1744259114546282","pdf_url":null,"source":{"id":"https://openalex.org/S140027543","display_name":"Journal of Building Physics","issn_l":"1097-1963","issn":["1097-1963","1530-8073","1744-2583","1744-2591"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["anvur-class-a","anvur-scientific","cwts-core","dongbi-c","jufo-2","norway-1","norway-2","poland-100","russia-white-list-1","vabb-shw"],"host_organization":"https://openalex.org/P4310320017","host_organization_name":"SAGE Publishing","host_organization_lineage":["https://openalex.org/P4310320017"],"host_organization_lineage_names":["SAGE Publishing"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Journal of Building Physics","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","score":0.5690000057220459,"id":"https://metadata.un.org/sdg/7"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":22,"referenced_works":["https://openalex.org/W119942276","https://openalex.org/W190539976","https://openalex.org/W1970710674","https://openalex.org/W2003875343","https://openalex.org/W2004719437","https://openalex.org/W2008890738","https://openalex.org/W2031589988","https://openalex.org/W2039066378","https://openalex.org/W2045829824","https://openalex.org/W2046918554","https://openalex.org/W2048162023","https://openalex.org/W2053221497","https://openalex.org/W2056833868","https://openalex.org/W2067840050","https://openalex.org/W2079902836","https://openalex.org/W2082041457","https://openalex.org/W2092326226","https://openalex.org/W2094075347","https://openalex.org/W2094364099","https://openalex.org/W2142854925","https://openalex.org/W2167920229","https://openalex.org/W3149443718"],"related_works":["https://openalex.org/W4321349183","https://openalex.org/W2751475936","https://openalex.org/W4313788042","https://openalex.org/W4200431951","https://openalex.org/W2048779469","https://openalex.org/W2361784494","https://openalex.org/W2365976913","https://openalex.org/W2359822302","https://openalex.org/W7097039932","https://openalex.org/W4406938391"],"abstract_inverted_index":{"Ventilated":[0],"wall":[1,24,28,60,132],"structures":[2],"can":[3],"contribute":[4],"to":[5],"energy":[6],"saving":[7],"in":[8,32,42,77],"the":[9,18,51,54,58,69,78,91,99,103,117,123,146],"building":[10],"sector.":[11],"This":[12],"article":[13],"presents":[14],"a":[15,22,62,72,127,130,135,139],"study":[16],"of":[17,21,53,57,71,93,105,119,126],"cooling":[19,124],"performance":[20],"ventilated":[23,27,59,131,141],"component.":[25],"The":[26,47,113],"component":[29],"was":[30],"constructed":[31],"actual":[33],"scale":[34],"and":[35,67,88,95,102,107,138],"tested":[36],"under":[37],"real":[38],"weather":[39],"conditions":[40],"(summer)":[41],"an":[43],"outdoor":[44],"test":[45],"cell.":[46],"testing":[48],"configuration":[49,80],"comprised":[50],"recording":[52],"thermal":[55],"behaviour":[56],"with":[61,68,134,145],"fixed":[63],"air":[64,86,100,110,142],"gap":[65,101,143],"width":[66],"addition":[70],"radiant":[73,136],"barrier.":[74],"Several":[75],"variations":[76],"basic":[79],"were":[81],"also":[82],"tested,":[83],"namely,":[84],"different":[85],"inlet":[87],"outlet":[89],"areas,":[90],"use":[92,104],"natural":[94],"mechanical":[96],"ventilation":[97],"on":[98],"floating":[106],"controlled":[108],"room":[109],"temperature":[111],"regimes.":[112],"results":[114],"demonstrated":[115],"that":[116],"application":[118],"this":[120],"technique":[121],"reduces":[122],"load":[125],"building.":[128],"Especially,":[129],"equipped":[133],"barrier":[137],"mechanically":[140],"provided":[144],"most":[147],"beneficial":[148],"results.":[149]},"counts_by_year":[{"year":2026,"cited_by_count":2},{"year":2024,"cited_by_count":1},{"year":2022,"cited_by_count":1},{"year":2021,"cited_by_count":4},{"year":2019,"cited_by_count":1},{"year":2017,"cited_by_count":2}],"updated_date":"2026-10-08T09:06:37.294493","created_date":"2016-06-24T00:00:00"}
