{"id":"https://openalex.org/W2004373585","doi":"https://doi.org/10.1109/iicpe.2012.6450453","title":"PMSG based isolated wind energy conversion system (WECS) for variable load","display_name":"PMSG based isolated wind energy conversion system (WECS) for variable load","alternate_titles":[],"publication_year":2012,"publication_date":"2012-12-01","ids":{"openalex":"https://openalex.org/W2004373585","doi":"https://doi.org/10.1109/iicpe.2012.6450453","mag":"2004373585"},"language":"en","primary_location":{"id":"doi:10.1109/iicpe.2012.6450453","doi":"https://doi.org/10.1109/iicpe.2012.6450453","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iicpe.2012.6450453","pdf_url":null,"source":{"id":"https://openalex.org/S4306418635","display_name":"IEEE India International Conference on Power Electronics","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2012 IEEE 5th India International Conference on Power Electronics (IICPE)","raw_type":"proceedings-article"},"parent_works":[],"lineage":["https://openalex.org/W2004373585"],"child_works_count":0,"type":"conference-paper","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5112863382","display_name":"Ruchika","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Ruchika","raw_affiliation_strings":["Hindu College of Engineering, Sonipat, Haryana, India","EE Deptt., Hindu College of Engineering., Sonipat, Haryana, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Hindu College of Engineering, Sonipat, Haryana, India","institution_ids":[]},{"raw_affiliation_string":"EE Deptt., Hindu College of Engineering., Sonipat, Haryana, India","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5086320259","display_name":"Ritika Gour","orcid":"https://orcid.org/0000-0003-1088-7699","observed_orcids":["https://orcid.org/0000-0003-1088-7699"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Ritika Gour","raw_affiliation_strings":["Maharaja Agrasen Institute of Technology, New Delhi, India","EEE Deptt., Maharaja Agrasen Institute of Tech., Sec-22, Rohini, Delhi, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Maharaja Agrasen Institute of Technology, New Delhi, India","institution_ids":[]},{"raw_affiliation_string":"EEE Deptt., Maharaja Agrasen Institute of Tech., Sec-22, Rohini, Delhi, India","institution_ids":[]}]},{"author_position":"middle","author":{"id":null,"display_name":"Pulkit Jain","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Pulkit Jain","raw_affiliation_strings":["Maharaja Agrasen Institute of Technology, New Delhi, India","EEE Deptt., Maharaja Agrasen Institute of Tech., Sec-22, Rohini, Delhi, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Maharaja Agrasen Institute of Technology, New Delhi, India","institution_ids":[]},{"raw_affiliation_string":"EEE Deptt., Maharaja Agrasen Institute of Tech., Sec-22, Rohini, Delhi, India","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5032840450","display_name":"M. R. Rashmi","orcid":"https://orcid.org/0000-0001-8047-5097","observed_orcids":["https://orcid.org/0000-0001-8047-5097"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Rashmi","raw_affiliation_strings":["Maharaja Agrasen Institute of Technology, New Delhi, India","EEE Deptt., Maharaja Agrasen Institute of Tech., Sec-22, Rohini, Delhi, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Maharaja Agrasen Institute of Technology, New Delhi, India","institution_ids":[]},{"raw_affiliation_string":"EEE Deptt., Maharaja Agrasen Institute of Tech., Sec-22, Rohini, Delhi, India","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5022699161","display_name":"Rajveer Mittal","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Rajveer Mittal","raw_affiliation_strings":["Maharaja Agrasen Institute of Technology, New Delhi, India","EEE Deptt., Maharaja Agrasen Institute of Tech., Sec-22, Rohini, Delhi, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Maharaja Agrasen Institute of Technology, New Delhi, India","institution_ids":[]},{"raw_affiliation_string":"EEE Deptt., Maharaja Agrasen Institute of Tech., Sec-22, Rohini, Delhi, India","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5064922473","display_name":"S. S. Deswal","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"S.S. Deswal","raw_affiliation_strings":["Maharaja Agrasen Institute of Technology, New Delhi, India","EEE Deptt., Maharaja Agrasen Institute of Tech., Sec-22, Rohini, Delhi, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Maharaja Agrasen Institute of Technology, New Delhi, India","institution_ids":[]},{"raw_affiliation_string":"EEE Deptt., Maharaja Agrasen Institute of Tech., Sec-22, Rohini, Delhi, India","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":1.2155,"has_fulltext":false,"cited_by_count":4,"citation_normalized_percentile":{"value":0.72507635,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":97},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"6"},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10740","display_name":"Wind Turbine Control Systems","score":0.9878000020980835,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10740","display_name":"Wind Turbine Control Systems","score":0.9878000020980835,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14444","display_name":"Power Systems and Renewable Energy","score":0.007499999832361937,"subfield":{"id":"https://openalex.org/subfields/2102","display_name":"Energy Engineering and Power Technology"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.0007999999797903001,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/wind-energy-conversion-system","display_name":"wind energy conversion system","score":0.9660000205039978},{"id":"https://openalex.org/keywords/permanent-magnet-synchronous-generator","display_name":"permanent magnet synchronous generator","score":0.9700000286102295},{"id":"https://openalex.org/keywords/variable-speed-generator","display_name":"variable speed generator","score":0.8349999785423279},{"id":"https://openalex.org/keywords/isolated-load","display_name":"isolated load","score":0.7429999709129333},{"id":"https://openalex.org/keywords/battery-energy-storage","display_name":"battery energy storage","score":0.8790000081062317},{"id":"https://openalex.org/keywords/ac-dc-ac-conversion","display_name":"AC-DC-AC conversion","score":0.7870000004768372},{"id":"https://openalex.org/keywords/renewable-energy","display_name":"renewable energy","score":0.5239999890327454}],"concepts":[{"id":"https://openalex.org/C78600449","wikidata":"https://www.wikidata.org/wiki/Q43302","display_name":"Wind power","level":2,"score":0.7480520606040955},{"id":"https://openalex.org/C201320609","wikidata":"https://www.wikidata.org/wiki/Q3274420","display_name":"Permanent magnet synchronous generator","level":3,"score":0.7050580978393555},{"id":"https://openalex.org/C188573790","wikidata":"https://www.wikidata.org/wiki/Q12705","display_name":"Renewable energy","level":2,"score":0.5772929191589355},{"id":"https://openalex.org/C2780789856","wikidata":"https://www.wikidata.org/wiki/Q7915732","display_name":"Variable renewable energy","level":4,"score":0.5297832489013672},{"id":"https://openalex.org/C161067210","wikidata":"https://www.wikidata.org/wiki/Q1464943","display_name":"Wind speed","level":2,"score":0.5271846055984497},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.4981698989868164},{"id":"https://openalex.org/C73916439","wikidata":"https://www.wikidata.org/wiki/Q837718","display_name":"Energy storage","level":3,"score":0.48177430033683777},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4769634008407593},{"id":"https://openalex.org/C2780992000","wikidata":"https://www.wikidata.org/wiki/Q17016113","display_name":"Generator (circuit theory)","level":3,"score":0.4741104245185852},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.4607689380645752},{"id":"https://openalex.org/C182365436","wikidata":"https://www.wikidata.org/wiki/Q50701","display_name":"Variable (mathematics)","level":2,"score":0.4501396119594574},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.42780613899230957},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.38582631945610046},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.3701115846633911},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.29346975684165955},{"id":"https://openalex.org/C153294291","wikidata":"https://www.wikidata.org/wiki/Q25261","display_name":"Meteorology","level":1,"score":0.11546662449836731},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.10964107513427734},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C134306372","wikidata":"https://www.wikidata.org/wiki/Q7754","display_name":"Mathematical analysis","level":1,"score":0.0},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/iicpe.2012.6450453","doi":"https://doi.org/10.1109/iicpe.2012.6450453","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iicpe.2012.6450453","pdf_url":null,"source":{"id":"https://openalex.org/S4306418635","display_name":"IEEE India International Conference on Power Electronics","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2012 IEEE 5th India International Conference on Power Electronics (IICPE)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7","score":1.0},{"display_name":"Industry, innovation and infrastructure","id":"https://metadata.un.org/sdg/9","score":0.7207000255584717},{"display_name":"Climate action","id":"https://metadata.un.org/sdg/13","score":0.5351999998092651}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":13,"referenced_works":["https://openalex.org/W65252926","https://openalex.org/W101527653","https://openalex.org/W2010706280","https://openalex.org/W2048646826","https://openalex.org/W2145004257","https://openalex.org/W2156177943","https://openalex.org/W2167288578","https://openalex.org/W2169297157","https://openalex.org/W2182643338","https://openalex.org/W2319507305","https://openalex.org/W2414431741","https://openalex.org/W2532921589","https://openalex.org/W6728639595"],"related_works":["https://openalex.org/W2532921589","https://openalex.org/W7100650859","https://openalex.org/W4285250251","https://openalex.org/W2311298522","https://openalex.org/W2792526200","https://openalex.org/W2792235059","https://openalex.org/W2538178419","https://openalex.org/W2131774658","https://openalex.org/W6903497071","https://openalex.org/W4297030822"],"abstract_inverted_index":{"Wind":[0,13],"energy,":[1],"being":[2],"a":[3,81,90],"clean":[4],"and":[5,18,64],"renewable":[6],"source,":[7],"is":[8,15,24,54,73],"becoming":[9],"more":[10],"popular":[11],"day-by-day.":[12],"energy":[14,51,85,102],"also":[16],"economical":[17],"feasible":[19],"in":[20,46,61],"areas":[21],"where":[22],"electricity":[23],"not":[25],"available":[26],"due":[27],"to":[28,109],"high":[29],"cost":[30],"of":[31,36,58,83],"distribution.":[32],"The":[33],"main":[34],"disadvantage":[35],"wind":[37,59,84],"power":[38],"has":[39],"been":[40],"its":[41],"unreliable":[42],"nature":[43,57],"which":[44],"results":[45,60],"load":[47,108,111],"mismatching.":[48,112],"So":[49,69],"an":[50,70,101,106],"storage":[52,103],"device":[53,104],"needed.":[55],"Variable":[56],"variable":[62,65,91],"voltage":[63],"frequency":[66],"at":[67],"generator.":[68],"AC-DC-AC":[71],"link":[72],"required.":[74],"In":[75],"this":[76],"paper,":[77],"we":[78],"have":[79],"proposed":[80],"simulation":[82],"conversion":[86],"system":[87],"(WECS)":[88],"using":[89],"speed":[92],"permanent":[93],"magnet":[94],"synchronous":[95],"generator":[96],"(PMSG)":[97],"with":[98],"battery":[99],"as":[100],"for":[105],"isolated":[107],"prevent":[110]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W2004373585","counts_by_year":[{"year":2017,"cited_by_count":1},{"year":2014,"cited_by_count":3}],"updated_date":"2026-11-17T12:49:18.490984","created_date":"2016-06-24T00:00:00"}
