{"id":"https://openalex.org/W2004178375","doi":"https://doi.org/10.1109/cpre.2012.6201238","title":"Validating transmission line impedances using known event data","display_name":"Validating transmission line impedances using known event data","alternate_titles":[],"publication_year":2012,"publication_date":"2012-04-01","ids":{"openalex":"https://openalex.org/W2004178375","doi":"https://doi.org/10.1109/cpre.2012.6201238","mag":"2004178375"},"language":"en","primary_location":{"id":"doi:10.1109/cpre.2012.6201238","doi":"https://doi.org/10.1109/cpre.2012.6201238","is_oa":false,"landing_page_url":"https://doi.org/10.1109/cpre.2012.6201238","pdf_url":null,"source":{"id":"https://openalex.org/S4306418003","display_name":"Conference for Protective Relay Engineers","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2012 65th Annual Conference for Protective Relay Engineers","raw_type":"proceedings-article"},"parent_works":[],"lineage":["https://openalex.org/W2004178375"],"child_works_count":0,"type":"conference-paper","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5004641253","display_name":"Ariana Amberg","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4405273072","display_name":"Schweitzer Engineering Laboratories (United States)","ror":"https://ror.org/057yrm276","country_code":"US","type":"company","lineage":["https://openalex.org/I4405273072"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Ariana Amberg","raw_affiliation_strings":["Schweitzer Engineering Laboratories, Inc., USA","SCHWEITZER ENGINEERING LABORATORIES, INC"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Schweitzer Engineering Laboratories, Inc., USA","institution_ids":["https://openalex.org/I4405273072"]},{"raw_affiliation_string":"SCHWEITZER ENGINEERING LABORATORIES, INC","institution_ids":["https://openalex.org/I4405273072"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5113946124","display_name":"Alex Rangel","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4405273072","display_name":"Schweitzer Engineering Laboratories (United States)","ror":"https://ror.org/057yrm276","country_code":"US","type":"company","lineage":["https://openalex.org/I4405273072"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Alex Rangel","raw_affiliation_strings":["Schweitzer Engineering Laboratories, Inc., USA","SCHWEITZER ENGINEERING LABORATORIES, INC"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Schweitzer Engineering Laboratories, Inc., USA","institution_ids":["https://openalex.org/I4405273072"]},{"raw_affiliation_string":"SCHWEITZER ENGINEERING LABORATORIES, INC","institution_ids":["https://openalex.org/I4405273072"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5028417419","display_name":"Greg Smelich","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4405273072","display_name":"Schweitzer Engineering Laboratories (United States)","ror":"https://ror.org/057yrm276","country_code":"US","type":"company","lineage":["https://openalex.org/I4405273072"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Greg Smelich","raw_affiliation_strings":["Schweitzer Engineering Laboratories, Inc., USA","SCHWEITZER ENGINEERING LABORATORIES, INC"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Schweitzer Engineering Laboratories, Inc., USA","institution_ids":["https://openalex.org/I4405273072"]},{"raw_affiliation_string":"SCHWEITZER ENGINEERING LABORATORIES, INC","institution_ids":["https://openalex.org/I4405273072"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I4405273072"],"apc_list":null,"apc_paid":null,"fwci":1.2029,"has_fulltext":false,"cited_by_count":21,"citation_normalized_percentile":{"value":0.7118592,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":86,"max":98},"biblio":{"volume":null,"issue":null,"first_page":"269","last_page":"280"},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.9970999956130981,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.9970999956130981,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.002400000113993883,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14502","display_name":"High-Voltage Power Transmission Systems","score":0.00039999998989515007,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/transmission-line-impedance","display_name":"transmission line impedance","score":0.9259999990463257},{"id":"https://openalex.org/keywords/sequence-impedance","display_name":"sequence impedance","score":0.6790000200271606},{"id":"https://openalex.org/keywords/fault-localization","display_name":"fault location","score":0.8640000224113464},{"id":"https://openalex.org/keywords/power-system-protection","display_name":"power system protection","score":0.6449999809265137}],"concepts":[{"id":"https://openalex.org/C17829176","wikidata":"https://www.wikidata.org/wiki/Q179043","display_name":"Electrical impedance","level":2,"score":0.755948007106781},{"id":"https://openalex.org/C33441834","wikidata":"https://www.wikidata.org/wiki/Q693004","display_name":"Transmission line","level":2,"score":0.7195191383361816},{"id":"https://openalex.org/C2778156585","wikidata":"https://www.wikidata.org/wiki/Q174053","display_name":"Relay","level":3,"score":0.6336573362350464},{"id":"https://openalex.org/C198352243","wikidata":"https://www.wikidata.org/wiki/Q37105","display_name":"Line (geometry)","level":2,"score":0.6165949702262878},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.5597230195999146},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.5533593893051147},{"id":"https://openalex.org/C2779662365","wikidata":"https://www.wikidata.org/wiki/Q5416694","display_name":"Event (particle physics)","level":2,"score":0.5377618670463562},{"id":"https://openalex.org/C140311924","wikidata":"https://www.wikidata.org/wiki/Q200928","display_name":"Electric power transmission","level":2,"score":0.5283691883087158},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4911770522594452},{"id":"https://openalex.org/C172066009","wikidata":"https://www.wikidata.org/wiki/Q5463955","display_name":"Focused Impedance Measurement","level":3,"score":0.4845503866672516},{"id":"https://openalex.org/C2412688","wikidata":"https://www.wikidata.org/wiki/Q503732","display_name":"Protective relay","level":4,"score":0.48154810070991516},{"id":"https://openalex.org/C761482","wikidata":"https://www.wikidata.org/wiki/Q118093","display_name":"Transmission (telecommunications)","level":2,"score":0.4363013803958893},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.43323901295661926},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.4111332893371582},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2500120997428894},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.22213539481163025},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.09481212496757507},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.07310393452644348},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/cpre.2012.6201238","doi":"https://doi.org/10.1109/cpre.2012.6201238","is_oa":false,"landing_page_url":"https://doi.org/10.1109/cpre.2012.6201238","pdf_url":null,"source":{"id":"https://openalex.org/S4306418003","display_name":"Conference for Protective Relay Engineers","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2012 65th Annual Conference for Protective Relay Engineers","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.5378999710083008,"display_name":"Industry, innovation and infrastructure","id":"https://metadata.un.org/sdg/9"}],"study_designs":[],"awards":[],"funders":[{"id":"https://openalex.org/F4320321091","display_name":"Coordena\u00e7\u00e3o de Aperfei\u00e7oamento de Pessoal de N\u00edvel Superior","ror":"https://ror.org/00x0ma614"}],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":10,"referenced_works":["https://openalex.org/W239153407","https://openalex.org/W605663379","https://openalex.org/W1561087287","https://openalex.org/W1600868767","https://openalex.org/W1983624355","https://openalex.org/W2066184070","https://openalex.org/W2074816966","https://openalex.org/W2127134315","https://openalex.org/W4205348634","https://openalex.org/W7006162351"],"related_works":["https://openalex.org/W2768177017","https://openalex.org/W2900215375","https://openalex.org/W2001754704","https://openalex.org/W2166588689","https://openalex.org/W4231700278","https://openalex.org/W2924175597","https://openalex.org/W3119269868","https://openalex.org/W2270664391","https://openalex.org/W2170345304","https://openalex.org/W631339358"],"abstract_inverted_index":{"This":[0],"paper":[1],"discusses":[2],"how":[3],"to":[4,22,39],"use":[5],"event":[6,34],"data":[7,35],"(voltages,":[8],"currents,":[9],"and":[10,26,43],"fault":[11],"location)":[12],"from":[13,32],"relays":[14],"at":[15],"two":[16],"ends":[17],"of":[18],"a":[19],"transmission":[20],"line":[21,28],"calculate":[23],"positive-,":[24],"negative-,":[25],"zero-sequence":[27],"impedances.":[29],"Impedances":[30],"calculated":[31],"real":[33],"can":[36],"be":[37],"used":[38],"validate":[40],"relay":[41],"settings":[42],"short-circuit":[44],"models.":[45]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W2004178375","counts_by_year":[{"year":2025,"cited_by_count":1},{"year":2023,"cited_by_count":3},{"year":2022,"cited_by_count":1},{"year":2021,"cited_by_count":2},{"year":2020,"cited_by_count":2},{"year":2019,"cited_by_count":1},{"year":2018,"cited_by_count":6},{"year":2017,"cited_by_count":2},{"year":2015,"cited_by_count":1},{"year":2014,"cited_by_count":2}],"updated_date":"2026-11-18T13:11:19.462570","created_date":"2016-06-24T00:00:00"}
