{"id":"https://openalex.org/W2003570781","doi":"https://doi.org/10.1177/073490419501300302","title":"Computerized Fire Risk Assessment Models: A Regulatory Effectiveness Analysis","display_name":"Computerized Fire Risk Assessment Models: A Regulatory Effectiveness Analysis","publication_year":1995,"publication_date":"1995-05-01","ids":{"openalex":"https://openalex.org/W2003570781","doi":"https://doi.org/10.1177/073490419501300302","mag":"2003570781"},"language":"en","primary_location":{"id":"doi:10.1177/073490419501300302","doi":"https://doi.org/10.1177/073490419501300302","is_oa":false,"landing_page_url":"https://doi.org/10.1177/073490419501300302","pdf_url":null,"source":{"id":"https://openalex.org/S68590195","display_name":"Journal of Fire Sciences","issn_l":"0734-9041","issn":["0734-9041","1530-8049"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-b","jufo-1","norway-1","poland-100","russia-white-list-2"],"host_organization":"https://openalex.org/P4310320017","host_organization_name":"SAGE Publishing","host_organization_lineage":["https://openalex.org/P4310320017"],"host_organization_lineage_names":["SAGE Publishing"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Journal of Fire Sciences","raw_type":"journal-article"},"volume":null,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5109999601","display_name":"Vincent M. Brannigan","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I66946132","display_name":"University of Maryland, College Park","ror":"https://ror.org/047s2c258","country_code":"US","type":"education","lineage":["https://openalex.org/I66946132"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Vincent Brannigan","raw_affiliation_strings":["Department of Fire Protection Engineering University of Maryland College Park College Park, MD 20741"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Fire Protection Engineering University of Maryland College Park College Park, MD 20741","institution_ids":["https://openalex.org/I66946132"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5010355976","display_name":"Carol B. Meeks","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I165733156","display_name":"University of Georgia","ror":"https://ror.org/00te3t702","country_code":"US","type":"education","lineage":["https://openalex.org/I165733156"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Carol Meeks","raw_affiliation_strings":["Department of Housing and Consumer Economics University of Georgia Athens, Georgia 30602-3622"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Housing and Consumer Economics University of Georgia Athens, Georgia 30602-3622","institution_ids":["https://openalex.org/I165733156"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":{"value":4150,"currency":"USD","value_usd":4150},"apc_paid":null,"fwci":4.2511,"has_fulltext":false,"cited_by_count":8,"citation_normalized_percentile":{"value":0.9264309,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":88,"max":93},"biblio":{"volume":"13","issue":"3","first_page":"177","last_page":"196"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11357","display_name":"Risk and Safety Analysis","score":0.7788000106811523,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11357","display_name":"Risk and Safety Analysis","score":0.7788000106811523,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11317","display_name":"Fire dynamics and safety research","score":0.11420000344514847,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12185","display_name":"Regulation and Compliance Studies","score":0.020800000056624413,"subfield":{"id":"https://openalex.org/subfields/3321","display_name":"Public Administration"},"field":{"id":"https://openalex.org/fields/33","display_name":"Social Sciences"},"domain":{"id":"https://openalex.org/domains/2","display_name":"Social Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/fire-safety-regulations","display_name":"fire safety regulations","score":0.7360000014305115},{"id":"https://openalex.org/keywords/model-validation","display_name":"model validation","score":0.4819999933242798},{"id":"https://openalex.org/keywords/model-verification","display_name":"model verification","score":0.9169999957084656}],"concepts":[{"id":"https://openalex.org/C2780069185","wikidata":"https://www.wikidata.org/wiki/Q7977945","display_name":"Equivalence (formal languages)","level":2,"score":0.7414842844009399},{"id":"https://openalex.org/C3017944768","wikidata":"https://www.wikidata.org/wiki/Q1450463","display_name":"Poison control","level":2,"score":0.48095932602882385},{"id":"https://openalex.org/C12174686","wikidata":"https://www.wikidata.org/wiki/Q1058438","display_name":"Risk assessment","level":2,"score":0.4550796449184418},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.44517287611961365},{"id":"https://openalex.org/C112930515","wikidata":"https://www.wikidata.org/wiki/Q4389547","display_name":"Risk analysis (engineering)","level":1,"score":0.43698474764823914},{"id":"https://openalex.org/C117222624","wikidata":"https://www.wikidata.org/wiki/Q7575010","display_name":"Specification","level":2,"score":0.41604992747306824},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3896075487136841},{"id":"https://openalex.org/C42475967","wikidata":"https://www.wikidata.org/wiki/Q194292","display_name":"Operations research","level":1,"score":0.3310914635658264},{"id":"https://openalex.org/C38652104","wikidata":"https://www.wikidata.org/wiki/Q3510521","display_name":"Computer security","level":1,"score":0.20480388402938843},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.18289580941200256},{"id":"https://openalex.org/C119857082","wikidata":"https://www.wikidata.org/wiki/Q2539","display_name":"Machine learning","level":1,"score":0.14037606120109558},{"id":"https://openalex.org/C144133560","wikidata":"https://www.wikidata.org/wiki/Q4830453","display_name":"Business","level":0,"score":0.09554347395896912},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.07931241393089294},{"id":"https://openalex.org/C99454951","wikidata":"https://www.wikidata.org/wiki/Q932068","display_name":"Environmental health","level":1,"score":0.07902657985687256},{"id":"https://openalex.org/C118615104","wikidata":"https://www.wikidata.org/wiki/Q121416","display_name":"Discrete mathematics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1177/073490419501300302","doi":"https://doi.org/10.1177/073490419501300302","is_oa":false,"landing_page_url":"https://doi.org/10.1177/073490419501300302","pdf_url":null,"source":{"id":"https://openalex.org/S68590195","display_name":"Journal of Fire Sciences","issn_l":"0734-9041","issn":["0734-9041","1530-8049"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-b","jufo-1","norway-1","poland-100","russia-white-list-2"],"host_organization":"https://openalex.org/P4310320017","host_organization_name":"SAGE Publishing","host_organization_lineage":["https://openalex.org/P4310320017"],"host_organization_lineage_names":["SAGE Publishing"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Journal of Fire Sciences","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":13,"referenced_works":["https://openalex.org/W1521703185","https://openalex.org/W1539179360","https://openalex.org/W1800641985","https://openalex.org/W1879184031","https://openalex.org/W1965572848","https://openalex.org/W2008774342","https://openalex.org/W2041148343","https://openalex.org/W2056170407","https://openalex.org/W2083435509","https://openalex.org/W2097614924","https://openalex.org/W2580989708","https://openalex.org/W3124228313","https://openalex.org/W4241724657"],"related_works":["https://openalex.org/W2113350894","https://openalex.org/W2051818275","https://openalex.org/W1985600477","https://openalex.org/W7043250943","https://openalex.org/W7132311828","https://openalex.org/W1486980987","https://openalex.org/W7151700780","https://openalex.org/W2079081726","https://openalex.org/W2227173500","https://openalex.org/W4206280529"],"abstract_inverted_index":{"Computerized":[0],"Fire":[1],"Risk":[2],"Assessment":[3],"Models":[4],"have":[5],"been":[6],"proposed":[7],"for":[8],"regulatory":[9],"use.":[10],"The":[11],"models":[12],"normally":[13],"are":[14,24,53],"used":[15,49,66,100],"to":[16,20,26,67,83,107],"examine":[17],"alternative":[18],"designs":[19],"determine":[21,68],"whether":[22,69,78],"they":[23],"equivalent":[25],"standard":[27],"code":[28],"approved":[29],"Structures.":[30],"However,":[31],"mathematical":[32],"equivalence":[33],"in":[34,50,101],"a":[35,61],"model":[36,52,71,115],"may":[37],"not":[38,54],"constitute":[39],"social":[40],"or":[41],"technical":[42],"equivalence,":[43],"if":[44],"the":[45,51,70,73,96,102,114],"assumptions":[46],"and":[47,77,98,104,111],"methods":[48],"property":[55],"specified.":[56],"Regulatory":[57],"Effectiveness":[58],"Analysis":[59],"is":[60,80],"tool":[62],"which":[63],"can":[64],"be":[65,105],"satisfies":[72],"regulator's":[74],"legal":[75],"requirements,":[76],"it":[79],"properly":[81],"responsive":[82],"public":[84],"judgments":[85],"of":[86,95,113],"fire":[87],"safety.":[88],"Model":[89],"builders":[90],"should":[91],"expect":[92],"detailed":[93],"examination":[94],"specifications":[97],"data":[99],"model,":[103],"prepared":[106],"show":[108],"competent":[109],"verification":[110],"validation":[112],"results.":[116]},"counts_by_year":[{"year":2020,"cited_by_count":1},{"year":2014,"cited_by_count":1},{"year":2012,"cited_by_count":1}],"updated_date":"2026-09-22T06:50:58.402377","created_date":"2016-06-24T00:00:00"}
