{"id":"https://openalex.org/W2003176582","doi":"https://doi.org/10.1061/(asce)cf.1943-5509.0000619","title":"Maintenance Performance: Examination of the Computer-Aided Maintenance Data of a Large Commercial Building","display_name":"Maintenance Performance: Examination of the Computer-Aided Maintenance Data of a Large Commercial Building","alternate_titles":[],"publication_year":2014,"publication_date":"2014-09-03","ids":{"openalex":"https://openalex.org/W2003176582","doi":"https://doi.org/10.1061/(asce)cf.1943-5509.0000619","mag":"2003176582"},"language":"en","primary_location":{"id":"doi:10.1061/(asce)cf.1943-5509.0000619","doi":"https://doi.org/10.1061/(asce)cf.1943-5509.0000619","is_oa":false,"landing_page_url":"https://doi.org/10.1061/(asce)cf.1943-5509.0000619","pdf_url":null,"source":{"id":"https://openalex.org/S46775058","display_name":"Journal of Performance of Constructed Facilities","issn_l":"0887-3828","issn":["0887-3828","1943-5509"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["abdc-c","anvur-scientific","cwts-core","dongbi-b","jufo-1","norway-1","poland-70","russia-white-list-2","vabb-shw"],"host_organization":"https://openalex.org/P4310315747","host_organization_name":"American Society of Civil Engineers","host_organization_lineage":["https://openalex.org/P4310315747"],"host_organization_lineage_names":["American Society of Civil Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Journal of Performance of Constructed Facilities","raw_type":"journal-article"},"parent_works":[],"lineage":["https://openalex.org/W2003176582"],"child_works_count":0,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5024814429","display_name":"Joseph H.K. Lai","orcid":"https://orcid.org/0000-0003-0526-4331","observed_orcids":["https://orcid.org/0000-0003-0526-4331"]},"institutions":[{"id":"https://openalex.org/I14243506","display_name":"Hong Kong Polytechnic University","ror":"https://ror.org/0030zas98","country_code":"HK","type":"education","lineage":["https://openalex.org/I14243506"]}],"countries":["HK"],"is_corresponding":true,"raw_author_name":"Joseph H. K. Lai","raw_affiliation_strings":["Associate Professor, Dept. of Building Services Engineering, Hong Kong Polytechnic Univ., Hong Kong SAR, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Associate Professor, Dept. of Building Services Engineering, Hong Kong Polytechnic Univ., Hong Kong SAR, China","institution_ids":["https://openalex.org/I14243506"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":["https://openalex.org/A5024814429"],"corresponding_institution_ids":["https://openalex.org/I14243506"],"apc_list":null,"apc_paid":null,"fwci":1.2277,"has_fulltext":false,"cited_by_count":22,"citation_normalized_percentile":{"value":0.80508226,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":86,"max":98},"biblio":{"volume":"29","issue":"4","first_page":null,"last_page":null},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10780","display_name":"Reliability and Maintenance Optimization","score":0.9458000063896179,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10780","display_name":"Reliability and Maintenance Optimization","score":0.9458000063896179,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14138","display_name":"Life Cycle Costing Analysis","score":0.013100000098347664,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11006","display_name":"BIM and Construction Integration","score":0.011300000362098217,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/maintenance-performance","display_name":"maintenance performance","score":0.9240000247955322},{"id":"https://openalex.org/keywords/commercial-buildings","display_name":"commercial buildings","score":0.9070000052452087},{"id":"https://openalex.org/keywords/maintenance-data","display_name":"maintenance data","score":0.7730000019073486},{"id":"https://openalex.org/keywords/corrective-maintenance","display_name":"corrective maintenance","score":0.9779999852180481},{"id":"https://openalex.org/keywords/electrical-equipment-maintenance","display_name":"electrical maintenance","score":0.8169999718666077},{"id":"https://openalex.org/keywords/repair-time","display_name":"repair time","score":0.972000002861023},{"id":"https://openalex.org/keywords/downtime","display_name":"downtime","score":0.9639999866485596},{"id":"https://openalex.org/keywords/benchmarking","display_name":"benchmarking","score":0.7910000085830688},{"id":"https://openalex.org/keywords/building-facilities","display_name":"building facilities","score":0.5830000042915344}],"concepts":[{"id":"https://openalex.org/C180591934","wikidata":"https://www.wikidata.org/wiki/Q1253369","display_name":"Downtime","level":2,"score":0.8118910789489746},{"id":"https://openalex.org/C86251818","wikidata":"https://www.wikidata.org/wiki/Q816754","display_name":"Benchmarking","level":2,"score":0.6689450740814209},{"id":"https://openalex.org/C70452415","wikidata":"https://www.wikidata.org/wiki/Q3182448","display_name":"Predictive maintenance","level":2,"score":0.6594942212104797},{"id":"https://openalex.org/C105339364","wikidata":"https://www.wikidata.org/wiki/Q2297740","display_name":"Software deployment","level":2,"score":0.6559914350509644},{"id":"https://openalex.org/C115837547","wikidata":"https://www.wikidata.org/wiki/Q1122495","display_name":"Computerized maintenance management system","level":3,"score":0.6401249766349792},{"id":"https://openalex.org/C4402595","wikidata":"https://www.wikidata.org/wiki/Q1043452","display_name":"Planned maintenance","level":2,"score":0.5602188110351562},{"id":"https://openalex.org/C141417316","wikidata":"https://www.wikidata.org/wiki/Q3278390","display_name":"Proactive maintenance","level":3,"score":0.534388542175293},{"id":"https://openalex.org/C129529059","wikidata":"https://www.wikidata.org/wiki/Q2291518","display_name":"Corrective maintenance","level":3,"score":0.5088396668434143},{"id":"https://openalex.org/C14922295","wikidata":"https://www.wikidata.org/wiki/Q7097783","display_name":"Operational maintenance","level":4,"score":0.5079613327980042},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.4947302043437958},{"id":"https://openalex.org/C117009084","wikidata":"https://www.wikidata.org/wiki/Q837060","display_name":"Facility management","level":2,"score":0.48289942741394043},{"id":"https://openalex.org/C18762648","wikidata":"https://www.wikidata.org/wiki/Q42213","display_name":"Work (physics)","level":2,"score":0.4781666398048401},{"id":"https://openalex.org/C24090081","wikidata":"https://www.wikidata.org/wiki/Q1043452","display_name":"Preventive maintenance","level":2,"score":0.45001640915870667},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.4284493923187256},{"id":"https://openalex.org/C158066952","wikidata":"https://www.wikidata.org/wiki/Q960289","display_name":"Work order","level":2,"score":0.4155159592628479},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.3587035536766052},{"id":"https://openalex.org/C112930515","wikidata":"https://www.wikidata.org/wiki/Q4389547","display_name":"Risk analysis (engineering)","level":1,"score":0.3493441343307495},{"id":"https://openalex.org/C144133560","wikidata":"https://www.wikidata.org/wiki/Q4830453","display_name":"Business","level":0,"score":0.12264800071716309},{"id":"https://openalex.org/C162853370","wikidata":"https://www.wikidata.org/wiki/Q39809","display_name":"Marketing","level":1,"score":0.0},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.0},{"id":"https://openalex.org/C115903868","wikidata":"https://www.wikidata.org/wiki/Q80993","display_name":"Software engineering","level":1,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1061/(asce)cf.1943-5509.0000619","doi":"https://doi.org/10.1061/(asce)cf.1943-5509.0000619","is_oa":false,"landing_page_url":"https://doi.org/10.1061/(asce)cf.1943-5509.0000619","pdf_url":null,"source":{"id":"https://openalex.org/S46775058","display_name":"Journal of Performance of Constructed Facilities","issn_l":"0887-3828","issn":["0887-3828","1943-5509"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["abdc-c","anvur-scientific","cwts-core","dongbi-b","jufo-1","norway-1","poland-70","russia-white-list-2","vabb-shw"],"host_organization":"https://openalex.org/P4310315747","host_organization_name":"American Society of Civil Engineers","host_organization_lineage":["https://openalex.org/P4310315747"],"host_organization_lineage_names":["American Society of Civil Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Journal of Performance of Constructed Facilities","raw_type":"journal-article"},{"id":"pmh:oai:ira.lib.polyu.edu.hk:10397/36084","doi":null,"is_oa":false,"landing_page_url":"http://hdl.handle.net/10397/36084","pdf_url":null,"source":{"id":"https://openalex.org/S4306400205","display_name":"PolyU Institutional Research Archive (Hong Kong Polytechnic University)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I14243506","host_organization_name":"Hong Kong Polytechnic University","host_organization_lineage":["https://openalex.org/I14243506"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"Journal/Magazine Article"}],"best_oa_location":null,"sustainable_development_goals":[],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":20,"referenced_works":["https://openalex.org/W6930101","https://openalex.org/W20616563","https://openalex.org/W41976657","https://openalex.org/W590501646","https://openalex.org/W1973883853","https://openalex.org/W1978978192","https://openalex.org/W1988314038","https://openalex.org/W1996970478","https://openalex.org/W1997947634","https://openalex.org/W2004345762","https://openalex.org/W2012233226","https://openalex.org/W2057044234","https://openalex.org/W2072096054","https://openalex.org/W2074695241","https://openalex.org/W2086618373","https://openalex.org/W2087442202","https://openalex.org/W2120924512","https://openalex.org/W2144959717","https://openalex.org/W2580902205","https://openalex.org/W2792823297"],"related_works":["https://openalex.org/W41976657","https://openalex.org/W2074695241","https://openalex.org/W1996970478","https://openalex.org/W2271941319","https://openalex.org/W7034763658","https://openalex.org/W4406307946","https://openalex.org/W2013929247","https://openalex.org/W4388485246","https://openalex.org/W2794499642","https://openalex.org/W2234728797"],"abstract_inverted_index":{"Commercial":[0],"buildings,":[1,44],"which":[2,75],"are":[3,7,37,132],"ubiquitous":[4],"in":[5,27,42,60,93],"metropolises,":[6],"typically":[8],"equipped":[9],"with":[10],"a":[11,71,80],"wide":[12],"range":[13],"of":[14,18,23,47,66,70,111,116,146],"facilities.":[15],"Satisfactory":[16],"operation":[17,104],"the":[19,28,45,67,97,108,112,137,144],"facilities":[20,41],"necessitates":[21],"provision":[22],"effective":[24],"maintenance":[25,34,49,57,68,82,85,141,147],"works":[26,86,131],"long":[29],"run.":[30],"Since,":[31],"fully":[32],"computerized":[33],"management":[35],"systems":[36],"seldom":[38],"adopted":[39],"for":[40,125],"commercial":[43,73],"dearth":[46],"proper":[48],"data":[50,69],"makes":[51],"it":[52],"difficult":[53],"to":[54,89,107,134],"investigate":[55],"their":[56],"performance.":[58],"Reported":[59],"this":[61],"paper":[62],"is":[63],"an":[64],"examination":[65],"large":[72],"building,":[74],"were":[76,87,105,123],"recorded":[77],"semi-automatically":[78],"by":[79,96],"computer-aided":[81],"system.":[83],"The":[84],"found":[88],"be":[90],"mainly":[91],"corrective":[92],"nature,":[94],"dominated":[95],"electrical":[98],"trade.":[99],"Existing":[100],"occupancy":[101],"and":[102,121,127],"business":[103],"influential":[106],"issue":[109],"time":[110],"work":[113],"orders.":[114],"Benchmarks":[115],"response":[117],"time,":[118,120],"repair":[119],"downtime":[122],"established":[124],"evaluation":[126],"benchmarking":[128],"purposes.":[129],"Further":[130],"needed":[133],"probe":[135],"into":[136],"factors":[138],"that":[139],"affect":[140],"performance,":[142],"especially":[143],"effectiveness":[145],"manpower":[148],"deployment.":[149]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W2003176582","counts_by_year":[{"year":2026,"cited_by_count":7},{"year":2025,"cited_by_count":3},{"year":2024,"cited_by_count":1},{"year":2023,"cited_by_count":2},{"year":2022,"cited_by_count":1},{"year":2021,"cited_by_count":6},{"year":2017,"cited_by_count":2}],"updated_date":"2026-11-19T14:11:59.513116","created_date":"2016-06-24T00:00:00"}
