{"id":"https://openalex.org/W2002129731","doi":"https://doi.org/10.1109/tpas.1979.319475","title":"Generator Insulation Diagnostic Testing","display_name":"Generator Insulation Diagnostic Testing","publication_year":1979,"publication_date":"1979-09-01","ids":{"openalex":"https://openalex.org/W2002129731","doi":"https://doi.org/10.1109/tpas.1979.319475","mag":"2002129731"},"language":"en","primary_location":{"id":"doi:10.1109/tpas.1979.319475","doi":"https://doi.org/10.1109/tpas.1979.319475","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tpas.1979.319475","pdf_url":null,"source":{"id":"https://openalex.org/S35391503","display_name":"IEEE Transactions on Power Apparatus and Systems","issn_l":"0018-9510","issn":["0018-9510"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Power Apparatus and Systems","raw_type":"journal-article"},"volume":null,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5111645058","display_name":"M. Kurtz","orcid":"https://orcid.org/0009-0009-3665-3103","observed_orcids":["https://orcid.org/0009-0009-3665-3103"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"M. Kurtz","raw_affiliation_strings":["Ontario Hydro Research Division, Toronto, Canada","Ontario, Hydro"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Ontario Hydro Research Division, Toronto, Canada","institution_ids":[]},{"raw_affiliation_string":"Ontario, Hydro","institution_ids":[]}]},{"author_position":"last","author":{"id":null,"display_name":"J. Lyles","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"J. Lyles","raw_affiliation_strings":["Ontario Hydro Research Division, Toronto, Canada","Ontario, Hydro"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Ontario Hydro Research Division, Toronto, Canada","institution_ids":[]},{"raw_affiliation_string":"Ontario, Hydro","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":1.723,"has_fulltext":false,"cited_by_count":74,"citation_normalized_percentile":{"value":0.83076282,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":88,"max":95},"biblio":{"volume":"PAS-98","issue":"5","first_page":"1596","last_page":"1603"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10511","display_name":"High voltage insulation and dielectric phenomena","score":0.8925999999046326,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10511","display_name":"High voltage insulation and dielectric phenomena","score":0.8925999999046326,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11343","display_name":"Power Transformer Diagnostics and Insulation","score":0.09560000151395798,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10220","display_name":"Machine Fault Diagnosis Techniques","score":0.00279999990016222,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/partial-discharge-testing","display_name":"partial discharge testing","score":0.7440000176429749},{"id":"https://openalex.org/keywords/generator-insulation","display_name":"generator insulation","score":0.7210000157356262},{"id":"https://openalex.org/keywords/hydraulic-generator","display_name":"hydraulic generator","score":0.8349999785423279},{"id":"https://openalex.org/keywords/insulation-diagnostics","display_name":"insulation diagnosis","score":0.47200000286102295},{"id":"https://openalex.org/keywords/ontario-hydro","display_name":"Ontario Hydro","score":0.7360000014305115}],"concepts":[{"id":"https://openalex.org/C130143024","wikidata":"https://www.wikidata.org/wiki/Q1929972","display_name":"Partial discharge","level":3,"score":0.7193248867988586},{"id":"https://openalex.org/C2776529397","wikidata":"https://www.wikidata.org/wiki/Q190312","display_name":"Stator","level":2,"score":0.6846880912780762},{"id":"https://openalex.org/C2780992000","wikidata":"https://www.wikidata.org/wiki/Q17016113","display_name":"Generator (circuit theory)","level":3,"score":0.5767645239830017},{"id":"https://openalex.org/C133118237","wikidata":"https://www.wikidata.org/wiki/Q131502","display_name":"Electric generator","level":3,"score":0.5011918544769287},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.48256200551986694},{"id":"https://openalex.org/C151201525","wikidata":"https://www.wikidata.org/wiki/Q177239","display_name":"Limit (mathematics)","level":2,"score":0.4689003527164459},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.4539206027984619},{"id":"https://openalex.org/C82157600","wikidata":"https://www.wikidata.org/wiki/Q2671652","display_name":"Diagnostic test","level":2,"score":0.4509231746196747},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.41907137632369995},{"id":"https://openalex.org/C77595967","wikidata":"https://www.wikidata.org/wiki/Q3151013","display_name":"Forensic engineering","level":1,"score":0.3880782127380371},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.37317776679992676},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.35986799001693726},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.2688025236129761},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.19029119610786438},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.11114257574081421},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.1100856363773346},{"id":"https://openalex.org/C134306372","wikidata":"https://www.wikidata.org/wiki/Q7754","display_name":"Mathematical analysis","level":1,"score":0.0},{"id":"https://openalex.org/C194828623","wikidata":"https://www.wikidata.org/wiki/Q2861470","display_name":"Emergency medicine","level":1,"score":0.0},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tpas.1979.319475","doi":"https://doi.org/10.1109/tpas.1979.319475","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tpas.1979.319475","pdf_url":null,"source":{"id":"https://openalex.org/S35391503","display_name":"IEEE Transactions on Power Apparatus and Systems","issn_l":"0018-9510","issn":["0018-9510"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Power Apparatus and Systems","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy","score":0.571399986743927}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":4,"referenced_works":["https://openalex.org/W2092336492","https://openalex.org/W2118221486","https://openalex.org/W2163208524","https://openalex.org/W2548403860"],"related_works":["https://openalex.org/W2552850330","https://openalex.org/W2126254871","https://openalex.org/W7147287459","https://openalex.org/W2142883024","https://openalex.org/W2186014605","https://openalex.org/W4301462821","https://openalex.org/W2165175029","https://openalex.org/W4414591771","https://openalex.org/W4406825947","https://openalex.org/W2105085459"],"abstract_inverted_index":{"Ontario":[0],"Hydro's":[1],"experience":[2],"with":[3],"diagnostic":[4],"partial":[5],"discharge":[6],"tests":[7],"on":[8],"hydraulic":[9],"generators":[10],"over":[11],"a":[12,19],"period":[13],"of":[14,22],"five":[15],"years":[16],"shows":[17],"that":[18],"reliable":[20],"prediction":[21],"stator":[23],"insulation":[24],"condition":[25],"can":[26],"be":[27],"made":[28],"prior":[29],"to":[30,39],"physical":[31],"examination.":[32],"\"Action":[33],"limit":[34],"values\"":[35],"have":[36],"been":[37],"established":[38],"this":[40],"end.":[41]},"counts_by_year":[{"year":2022,"cited_by_count":2},{"year":2018,"cited_by_count":1},{"year":2016,"cited_by_count":1},{"year":2013,"cited_by_count":1},{"year":2012,"cited_by_count":1}],"updated_date":"2026-09-29T14:09:16.559479","created_date":"2016-06-24T00:00:00"}
