{"id":"https://openalex.org/W2000813433","doi":"https://doi.org/10.1109/t-pas.1975.31967","title":"Experience with part-winding resonance in EHV auto-transformers: Diagnosis and corrective measures","display_name":"Experience with part-winding resonance in EHV auto-transformers: Diagnosis and corrective measures","alternate_titles":[],"publication_year":1975,"publication_date":"1975-07-01","ids":{"openalex":"https://openalex.org/W2000813433","doi":"https://doi.org/10.1109/t-pas.1975.31967","mag":"2000813433"},"language":"en","primary_location":{"id":"doi:10.1109/t-pas.1975.31967","doi":"https://doi.org/10.1109/t-pas.1975.31967","is_oa":false,"landing_page_url":"https://doi.org/10.1109/t-pas.1975.31967","pdf_url":null,"source":{"id":"https://openalex.org/S35391503","display_name":"IEEE Transactions on Power Apparatus and Systems","issn_l":"0018-9510","issn":["0018-9510"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Power Apparatus and Systems","raw_type":"journal-article"},"parent_works":[],"lineage":["https://openalex.org/W2000813433"],"child_works_count":0,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":null,"display_name":"H.B. Margolis","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"H.B. Margolis","raw_affiliation_strings":["American Electric Power Service Corporation, New York, New York"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"American Electric Power Service Corporation, New York, New York","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5005181476","display_name":"J. D. M. Phelps","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"J.D.M. Phelps","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5052975617","display_name":"A.A. Carlomagno","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"A.A. Carlomagno","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"last","author":{"id":"https://openalex.org/A5049239545","display_name":"A. J. McElroy","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4401726924","display_name":"American Electric Power (United States)","ror":"https://ror.org/040asb018","country_code":"US","type":"company","lineage":["https://openalex.org/I4401726924"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"A.J. McElroy","raw_affiliation_strings":["[American Electric Power, Service Corporation, NY, USA]"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"[American Electric Power, Service Corporation, NY, USA]","institution_ids":["https://openalex.org/I4401726924"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":1.1961,"has_fulltext":false,"cited_by_count":47,"citation_normalized_percentile":{"value":0.75742017,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":87,"max":96},"biblio":{"volume":"94","issue":"4","first_page":"1294","last_page":"1300"},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11343","display_name":"Power Transformer Diagnostics and Insulation","score":0.9628999829292297,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11343","display_name":"Power Transformer Diagnostics and Insulation","score":0.9628999829292297,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14502","display_name":"High-Voltage Power Transmission Systems","score":0.020600000396370888,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10573","display_name":"Power Quality and Harmonics","score":0.00419999985024333,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/flashover","display_name":"flashover","score":0.7760000228881836},{"id":"https://openalex.org/keywords/transformer-failure","display_name":"transformer failure","score":0.6690000295639038},{"id":"https://openalex.org/keywords/system-faults","display_name":"system faults","score":0.6859999895095825},{"id":"https://openalex.org/keywords/system-transients","display_name":"system transients","score":0.7039999961853027},{"id":"https://openalex.org/keywords/dielectric-testing","display_name":"dielectric testing","score":0.7099999785423279},{"id":"https://openalex.org/keywords/arrester","display_name":"arrester","score":0.7599999904632568},{"id":"https://openalex.org/keywords/capacitor-bank","display_name":"capacitor bank","score":0.906000018119812}],"concepts":[{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.7412831783294678},{"id":"https://openalex.org/C66322947","wikidata":"https://www.wikidata.org/wiki/Q11658","display_name":"Transformer","level":3,"score":0.6014947891235352},{"id":"https://openalex.org/C30403606","wikidata":"https://www.wikidata.org/wiki/Q2981904","display_name":"Electromagnetic coil","level":2,"score":0.5623825788497925},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.5481404066085815},{"id":"https://openalex.org/C52192207","wikidata":"https://www.wikidata.org/wiki/Q5322","display_name":"Capacitor","level":3,"score":0.4455071687698364},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.411063551902771},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.324105441570282},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.3016446530818939},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.07285118103027344},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/t-pas.1975.31967","doi":"https://doi.org/10.1109/t-pas.1975.31967","is_oa":false,"landing_page_url":"https://doi.org/10.1109/t-pas.1975.31967","pdf_url":null,"source":{"id":"https://openalex.org/S35391503","display_name":"IEEE Transactions on Power Apparatus and Systems","issn_l":"0018-9510","issn":["0018-9510"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Power Apparatus and Systems","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.7207000255584717,"id":"https://metadata.un.org/sdg/9","display_name":"Industry, innovation and infrastructure"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":2,"referenced_works":["https://openalex.org/W2022364012","https://openalex.org/W2058901394"],"related_works":["https://openalex.org/W2123363816","https://openalex.org/W2543268391","https://openalex.org/W2057440020","https://openalex.org/W2526993825","https://openalex.org/W2015490354","https://openalex.org/W2333853173","https://openalex.org/W2067161430","https://openalex.org/W2074453750","https://openalex.org/W2540149202","https://openalex.org/W2049322870"],"abstract_inverted_index":{"Four":[0],"failures":[1,13],"of":[2,53],"large":[3],"EHV":[4],"auto-transformers":[5],"on":[6],"the":[7,19,30,81],"AEP":[8],"system":[9,24,48],"are":[10],"described.":[11],"The":[12,51],"were":[14],"initiated":[15],"by":[16],"flashovers":[17,31],"in":[18],"no-load":[20],"tap":[21],"changer":[22],"during":[23],"faults.":[25],"Investigations":[26],"and":[27,43,76],"tests":[28,55,60],"attribute":[29],"to":[32,47,56,71,80],"part-winding":[33],"resonance.":[34],"Test":[35],"data":[36],"is":[37,61],"presented":[38],"for":[39,65],"various":[40],"terminal":[41],"conditions":[42],"wave":[44],"shapes":[45],"corresponding":[46],"transient":[49],"conditions.":[50],"relationship":[52],"these":[54],"ANSI":[57],"standard":[58],"dielectric":[59],"discussed.":[62],"Corrective":[63],"measures":[64],"existing":[66],"transformers":[67],"include":[68],"arresters":[69],"tied":[70],"an":[72],"internal":[73],"crossover":[74],"connection":[75],"capacitor":[77],"banks":[78],"connected":[79],"delta":[82],"tertiary":[83],"windings.":[84]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W2000813433","counts_by_year":[{"year":2025,"cited_by_count":1},{"year":2022,"cited_by_count":2},{"year":2020,"cited_by_count":3},{"year":2018,"cited_by_count":1},{"year":2017,"cited_by_count":3},{"year":2015,"cited_by_count":1},{"year":2014,"cited_by_count":1},{"year":2013,"cited_by_count":3},{"year":2012,"cited_by_count":2}],"updated_date":"2026-11-16T12:05:36.265796","created_date":"2016-06-24T00:00:00"}