{"id":"https://openalex.org/W1998016556","doi":"https://doi.org/10.1109/upec.2014.6934813","title":"Compact local system designed for power transformer monitoring \u2014 Type MONITRA control process","display_name":"Compact local system designed for power transformer monitoring \u2014 Type MONITRA control process","publication_year":2014,"publication_date":"2014-09-01","ids":{"openalex":"https://openalex.org/W1998016556","doi":"https://doi.org/10.1109/upec.2014.6934813","mag":"1998016556"},"language":"en","primary_location":{"id":"doi:10.1109/upec.2014.6934813","doi":"https://doi.org/10.1109/upec.2014.6934813","is_oa":false,"landing_page_url":"https://doi.org/10.1109/upec.2014.6934813","pdf_url":null,"source":{"id":"https://openalex.org/S4363608403","display_name":"International Universities Power Engineering Conference (UPEC)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2014 49th International Universities Power Engineering Conference (UPEC)","raw_type":"proceedings-article"},"volume":null,"type":"conference-paper","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5032000335","display_name":"Dumitru Sacerdo\u021bianu","orcid":"https://orcid.org/0000-0001-5946-2400","observed_orcids":["https://orcid.org/0000-0001-5946-2400"]},"institutions":[{"id":"https://openalex.org/I4405265937","display_name":"ICMET Craiova","ror":"https://ror.org/01w96zs40","country_code":"RO","type":"education","lineage":["https://openalex.org/I4405265937"]}],"countries":["RO"],"is_corresponding":false,"raw_author_name":"Sacerdotianu Dumitru","raw_affiliation_strings":["National Institute for Research, Development and Testing in Electrical Engineering","National Institute for Research, Development and Testing in Electrical Engineering, ICMET Craiova"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"National Institute for Research, Development and Testing in Electrical Engineering","institution_ids":["https://openalex.org/I4405265937"]},{"raw_affiliation_string":"National Institute for Research, Development and Testing in Electrical Engineering, ICMET Craiova","institution_ids":["https://openalex.org/I4405265937"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5040817065","display_name":"Iulian Hurezeanu","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4405265937","display_name":"ICMET Craiova","ror":"https://ror.org/01w96zs40","country_code":"RO","type":"education","lineage":["https://openalex.org/I4405265937"]}],"countries":["RO"],"is_corresponding":false,"raw_author_name":"Hurezeanu Iulian","raw_affiliation_strings":["SC VIGIMPEX CRAIOV A","National Institute for Research, Development and Testing in Electrical Engineering, ICMET Craiova"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"SC VIGIMPEX CRAIOV A","institution_ids":[]},{"raw_affiliation_string":"National Institute for Research, Development and Testing in Electrical Engineering, ICMET Craiova","institution_ids":["https://openalex.org/I4405265937"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5083245563","display_name":"Ion Purcaru","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4405265937","display_name":"ICMET Craiova","ror":"https://ror.org/01w96zs40","country_code":"RO","type":"education","lineage":["https://openalex.org/I4405265937"]}],"countries":["RO"],"is_corresponding":false,"raw_author_name":"Purcaru Ion","raw_affiliation_strings":["National Institute for Research, Development and Testing in Electrical Engineering","SC VIGIMPEX Craiova"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"National Institute for Research, Development and Testing in Electrical Engineering","institution_ids":["https://openalex.org/I4405265937"]},{"raw_affiliation_string":"SC VIGIMPEX Craiova","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I4405265937"],"apc_list":null,"apc_paid":null,"fwci":0.4011,"has_fulltext":false,"cited_by_count":1,"citation_normalized_percentile":{"value":0.42783091,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":94},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"6"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11343","display_name":"Power Transformer Diagnostics and Insulation","score":0.7240999937057495,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11343","display_name":"Power Transformer Diagnostics and Insulation","score":0.7240999937057495,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12941","display_name":"Embedded Systems and FPGA Design","score":0.1835000067949295,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14225","display_name":"Advanced Sensor and Control Systems","score":0.02459999918937683,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/power-transformer-monitoring","display_name":"power transformer monitoring","score":0.9980000257492065},{"id":"https://openalex.org/keywords/embedded-systems","display_name":"embedded systems","score":0.6629999876022339},{"id":"https://openalex.org/keywords/optical-fiber-communication","display_name":"optical fiber communication","score":0.6970000267028809},{"id":"https://openalex.org/keywords/can-bus","display_name":"CAN bus","score":0.9649999737739563},{"id":"https://openalex.org/keywords/predictive-maintenance","display_name":"predictive maintenance","score":0.8489999771118164},{"id":"https://openalex.org/keywords/flash-memory-data-storage","display_name":"flash memory data storage","score":0.7070000171661377},{"id":"https://openalex.org/keywords/sampling-rate","display_name":"sampling frequency","score":0.5929999947547913}],"concepts":[{"id":"https://openalex.org/C43364308","wikidata":"https://www.wikidata.org/wiki/Q8799","display_name":"Byte","level":2,"score":0.5500147342681885},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5381188988685608},{"id":"https://openalex.org/C66322947","wikidata":"https://www.wikidata.org/wiki/Q11658","display_name":"Transformer","level":3,"score":0.4929678440093994},{"id":"https://openalex.org/C163985040","wikidata":"https://www.wikidata.org/wiki/Q1172399","display_name":"Data acquisition","level":2,"score":0.4824129343032837},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.4517095983028412},{"id":"https://openalex.org/C9390403","wikidata":"https://www.wikidata.org/wiki/Q3966","display_name":"Computer hardware","level":1,"score":0.3902961015701294},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.33869248628616333},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.3305644989013672},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.28236138820648193},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/upec.2014.6934813","doi":"https://doi.org/10.1109/upec.2014.6934813","is_oa":false,"landing_page_url":"https://doi.org/10.1109/upec.2014.6934813","pdf_url":null,"source":{"id":"https://openalex.org/S4363608403","display_name":"International Universities Power Engineering Conference (UPEC)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2014 49th International Universities Power Engineering Conference (UPEC)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/9","display_name":"Industry, innovation and infrastructure","score":0.7207000255584717}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":2,"referenced_works":["https://openalex.org/W1542271625","https://openalex.org/W2151913583"],"related_works":["https://openalex.org/W2110885227","https://openalex.org/W1970507875","https://openalex.org/W2366179261","https://openalex.org/W3160271123","https://openalex.org/W2377992159","https://openalex.org/W865492489","https://openalex.org/W2387892572","https://openalex.org/W4401537914","https://openalex.org/W2375959136","https://openalex.org/W2064029167"],"abstract_inverted_index":{"The":[0,34,143,176,190],"reliability":[1],"of":[2,14,16,43,75,93,125,140,173,180],"transformer":[3,174,187],"units":[4,120],"and":[5,81,91,121,135,149],"extending":[6],"their":[7,17,32],"life":[8],"depend":[9],"greatly":[10],"on":[11,117,131,202],"the":[12,25,41,53,73,79,85,89,97,102,108,113,123,132,136,141,158,162,165,169],"degree":[13],"monitoring":[15,99,126,171,188],"functional":[18],"parameters":[19,134],"with":[20,69,152],"a":[21,146,185,194],"view":[22],"to":[23,31,101,168],"determining":[24],"proper":[26],"predictive":[27],"maintenance":[28],"measures,":[29],"according":[30],"interpretation.":[33],"achievements":[35],"presented":[36,177],"in":[37,59,164],"this":[38],"paper":[39,144],"are":[40],"result":[42],"continuous":[44],"upgrading":[45],"which":[46],"consisted":[47],"in:":[48],"increasing":[49,62,72,84,88,112],"calculation":[50,56,58,63,82],"accuracy,":[51],"replacing":[52,66],"fixed":[54],"point":[55],"by":[57,65,77,106],"floating":[60],"point,":[61],"accuracy":[64],"10-byte":[67],"CAN":[68],"16-byte":[70],"CAN,":[71],"speed":[74,90],"acquisition-calculation":[76],"allocating":[78],"acquisition":[80],"functions,":[83],"sampling":[86],"rate,":[87],"security":[92],"data":[94,114],"transmission":[95],"from":[96],"local":[98,150,170],"system":[100,127],"central":[103,191],"processing":[104,161],"unit":[105,192],"introducing":[107],"fiber":[109,153],"optic":[110,154],"support,":[111],"storage":[115],"space":[116],"flash":[118],"memory":[119],"providing":[122],"possibility":[124],"software":[128],"configuration,":[129],"depending":[130],"monitored":[133],"reference":[137],"specific":[138],"elements":[139],"application.":[142],"presents":[145],"compact":[147],"embedded":[148],"version":[151,178],"support":[155],"implementation":[156],"within":[157],"circuits":[159],"for":[160,184,199],"information":[163],"field":[166],"corresponding":[167],"equipment":[172,182],"units.":[175],"is":[179,193],"integrated":[181],"implemented":[183],"power":[186],"system.":[189],"single":[195],"casting":[196],"structure":[197],"adapted":[198],"easy":[200],"fastening":[201],"electric":[203],"panels,":[204],"overall":[205],"dimensions":[206],"approx.":[207],"280mm":[208],"\u00d7":[209,211],"230mm":[210],"100mm.":[212]},"counts_by_year":[{"year":2017,"cited_by_count":1}],"updated_date":"2026-10-16T09:59:22.235173","created_date":"2016-06-24T00:00:00"}
