{"id":"https://openalex.org/W1997598796","doi":"https://doi.org/10.1109/tbme.1984.325237","title":"From Holter Monitors to Automatic Defibrillators: Developments in Ambulatory Arrhythmia Monitoring","display_name":"From Holter Monitors to Automatic Defibrillators: Developments in Ambulatory Arrhythmia Monitoring","publication_year":1984,"publication_date":"1984-12-01","ids":{"openalex":"https://openalex.org/W1997598796","doi":"https://doi.org/10.1109/tbme.1984.325237","mag":"1997598796","pmid":"https://pubmed.ncbi.nlm.nih.gov/6396202"},"language":"en","primary_location":{"id":"doi:10.1109/tbme.1984.325237","doi":"https://doi.org/10.1109/tbme.1984.325237","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tbme.1984.325237","pdf_url":null,"source":{"id":"https://openalex.org/S5240358","display_name":"IEEE Transactions on Biomedical Engineering","issn_l":"0018-9294","issn":["0018-9294","1558-2531"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["anvur-scientific","cwts-core","dongbi-b","jufo-2","ki-jl-1","medline","norway-1","poland-200","russia-white-list-1","vabb-shw"],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Biomedical Engineering","raw_type":"journal-article"},"volume":null,"type":"review","indexed_in":["crossref","pubmed"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5088964967","display_name":"Nitish V. Thakor","orcid":"https://orcid.org/0000-0002-9981-9395","observed_orcids":["https://orcid.org/0000-0002-9981-9395"]},"institutions":[{"id":"https://openalex.org/I145311948","display_name":"Johns Hopkins University","ror":"https://ror.org/00za53h95","country_code":"US","type":"education","lineage":["https://openalex.org/I145311948"]}],"countries":["US"],"is_corresponding":true,"raw_author_name":"Nitish V. Thakor","raw_affiliation_strings":["Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD, USA","[Department of Biomedical Engineering, Johns Hopkins University]"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD, USA","institution_ids":["https://openalex.org/I145311948"]},{"raw_affiliation_string":"[Department of Biomedical Engineering, Johns Hopkins University]","institution_ids":["https://openalex.org/I145311948"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":["https://openalex.org/A5088964967"],"corresponding_institution_ids":["https://openalex.org/I145311948"],"apc_list":{"value":2645,"currency":"USD","value_usd":2645},"apc_paid":null,"fwci":0.7343,"has_fulltext":false,"cited_by_count":65,"citation_normalized_percentile":{"value":0.57142857,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":97},"biblio":{"volume":"BME-31","issue":"12","first_page":"770","last_page":"778"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11021","display_name":"ECG Monitoring and Analysis","score":0.9955999851226807,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},"topics":[{"id":"https://openalex.org/T11021","display_name":"ECG Monitoring and Analysis","score":0.9955999851226807,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T10598","display_name":"Cardiac pacing and defibrillation studies","score":0.0020000000949949026,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.0010999999940395355,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/holter-monitor","display_name":"Holter monitor","score":0.7940000295639038},{"id":"https://openalex.org/keywords/holter-monitoring","display_name":"Holter monitoring","score":0.8579999804496765},{"id":"https://openalex.org/keywords/automatic-arrhythmia-detection","display_name":"automatic arrhythmia detection","score":0.7649999856948853},{"id":"https://openalex.org/keywords/implantable-cardioverter-defibrillator","display_name":"implantable cardioverter-defibrillator","score":0.7310000061988831},{"id":"https://openalex.org/keywords/ventricular-fibrillation-detection","display_name":"ventricular fibrillation detection","score":0.8519999980926514},{"id":"https://openalex.org/keywords/implantable-pacemaker","display_name":"implantable pacemaker","score":0.7940000295639038},{"id":"https://openalex.org/keywords/ecg-acquisition","display_name":"ECG signal acquisition","score":0.7429999709129333}],"concepts":[{"id":"https://openalex.org/C2909021529","wikidata":"https://www.wikidata.org/wiki/Q11490631","display_name":"Ambulatory ECG","level":3,"score":0.6724224090576172},{"id":"https://openalex.org/C132090242","wikidata":"https://www.wikidata.org/wiki/Q32738","display_name":"Microcomputer","level":3,"score":0.5318557620048523},{"id":"https://openalex.org/C35785553","wikidata":"https://www.wikidata.org/wiki/Q756720","display_name":"Ambulatory","level":2,"score":0.5221827030181885},{"id":"https://openalex.org/C2988455589","wikidata":"https://www.wikidata.org/wiki/Q189331","display_name":"Cardiac arrhythmia","level":3,"score":0.5069518089294434},{"id":"https://openalex.org/C2781005686","wikidata":"https://www.wikidata.org/wiki/Q848662","display_name":"Ventricular fibrillation","level":2,"score":0.5030815005302429},{"id":"https://openalex.org/C2780040984","wikidata":"https://www.wikidata.org/wiki/Q79785","display_name":"Electrocardiography","level":2,"score":0.4688830077648163},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.4644283056259155},{"id":"https://openalex.org/C2779843651","wikidata":"https://www.wikidata.org/wiki/Q7390335","display_name":"SIGNAL (programming language)","level":2,"score":0.4244520664215088},{"id":"https://openalex.org/C175079658","wikidata":"https://www.wikidata.org/wiki/Q7312165","display_name":"Remote patient monitoring","level":2,"score":0.4156174063682556},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.3526693284511566},{"id":"https://openalex.org/C164705383","wikidata":"https://www.wikidata.org/wiki/Q10379","display_name":"Cardiology","level":1,"score":0.309368371963501},{"id":"https://openalex.org/C2779161974","wikidata":"https://www.wikidata.org/wiki/Q815819","display_name":"Atrial fibrillation","level":2,"score":0.25578582286834717},{"id":"https://openalex.org/C126322002","wikidata":"https://www.wikidata.org/wiki/Q11180","display_name":"Internal medicine","level":1,"score":0.2318008542060852},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.14080369472503662},{"id":"https://openalex.org/C199360897","wikidata":"https://www.wikidata.org/wiki/Q9143","display_name":"Programming language","level":1,"score":0.0},{"id":"https://openalex.org/C126838900","wikidata":"https://www.wikidata.org/wiki/Q77604","display_name":"Radiology","level":1,"score":0.0},{"id":"https://openalex.org/C165005293","wikidata":"https://www.wikidata.org/wiki/Q1074500","display_name":"Chip","level":2,"score":0.0}],"mesh":[{"descriptor_ui":"D000553","descriptor_name":"Ambulatory Care","qualifier_ui":"Q000639","qualifier_name":"trends","is_major_topic":true},{"descriptor_ui":"D001145","descriptor_name":"Arrhythmias, Cardiac","qualifier_ui":"Q000175","qualifier_name":"diagnosis","is_major_topic":true},{"descriptor_ui":"D001145","descriptor_name":"Arrhythmias, Cardiac","qualifier_ui":"Q000628","qualifier_name":"therapy","is_major_topic":false},{"descriptor_ui":"D004554","descriptor_name":"Electric Countershock","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":true},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D008991","descriptor_name":"Monitoring, Physiologic","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":true}],"locations_count":2,"locations":[{"id":"doi:10.1109/tbme.1984.325237","doi":"https://doi.org/10.1109/tbme.1984.325237","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tbme.1984.325237","pdf_url":null,"source":{"id":"https://openalex.org/S5240358","display_name":"IEEE Transactions on Biomedical Engineering","issn_l":"0018-9294","issn":["0018-9294","1558-2531"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["anvur-scientific","cwts-core","dongbi-b","jufo-2","ki-jl-1","medline","norway-1","poland-200","russia-white-list-1","vabb-shw"],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Biomedical Engineering","raw_type":"journal-article"},{"id":"pmid:6396202","doi":null,"is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/6396202","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE transactions on bio-medical engineering","raw_type":"Journal Article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Good health and well-being","id":"https://metadata.un.org/sdg/3","score":0.8199999928474426}],"sustainable_development_goals_aurora":[{"display_name":"Good health and well-being","id":"https://metadata.un.org/sdg/3","score":0.5400000214576721}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":33,"referenced_works":["https://openalex.org/W186322017","https://openalex.org/W378654553","https://openalex.org/W1482688465","https://openalex.org/W1514868647","https://openalex.org/W1923684516","https://openalex.org/W1964081270","https://openalex.org/W1981964073","https://openalex.org/W1985095498","https://openalex.org/W1992280101","https://openalex.org/W1992556963","https://openalex.org/W2001823399","https://openalex.org/W2003109807","https://openalex.org/W2003584793","https://openalex.org/W2004726965","https://openalex.org/W2012868641","https://openalex.org/W2022784467","https://openalex.org/W2057818256","https://openalex.org/W2061599552","https://openalex.org/W2075226977","https://openalex.org/W2076718469","https://openalex.org/W2081419782","https://openalex.org/W2094908948","https://openalex.org/W2101475877","https://openalex.org/W2161999077","https://openalex.org/W2242679214","https://openalex.org/W2397420507","https://openalex.org/W2401234732","https://openalex.org/W2409326512","https://openalex.org/W2466461387","https://openalex.org/W2468338839","https://openalex.org/W2606608426","https://openalex.org/W4243393180","https://openalex.org/W6665743647"],"related_works":["https://openalex.org/W2135491405","https://openalex.org/W2466461387","https://openalex.org/W4240855181","https://openalex.org/W921491331","https://openalex.org/W588135495","https://openalex.org/W2416393902","https://openalex.org/W1991071650","https://openalex.org/W2254861656","https://openalex.org/W2494932091","https://openalex.org/W3186977824"],"abstract_inverted_index":{"In":[0,86],"1961,":[1],"Holter":[2,75],"reported":[3],"a":[4,7],"design":[5],"of":[6,24,34,42,72,92,100,111],"tape":[8],"recorder":[9],"that":[10],"acquired":[11],"and":[12,81,108],"stored":[13],"electrocardiographic":[14],"(ECG)":[15],"signals":[16],"from":[17],"ambulatory":[18,101],"patients.":[19],"This":[20],"made":[21],"long-term":[22],"monitoring":[23],"patients":[25],"in":[26],"their":[27],"day-to-day":[28],"environments":[29],"possible.":[30],"The":[31],"next":[32],"generation":[33],"devices":[35],"employ":[36],"microcomputer":[37],"circuits":[38],"for":[39],"automatic":[40,58,83],"interpretation":[41,51],"cardiac":[43],"arrhythmias.":[44],"Implantable":[45],"pacemaker":[46],"also":[47],"show":[48],"some":[49],"arrhythmia":[50,79,106,113],"capability.":[52],"A":[53],"special":[54],"case":[55],"is":[56],"the":[57,63,70,73,77,82,89,97],"implantable":[59,84],"defibrillator":[60],"which":[61],"recognizes":[62],"ventricular":[64],"fibrillation":[65],"signal.":[66],"We":[67],"present":[68,96],"here":[69],"details":[71],"original":[74],"recorder,":[76],"microcomputer-based":[78],"monitor,":[80],"defibrillator.":[85],"conjunction":[87],"with":[88],"historic":[90],"account":[91],"these":[93],"developments,":[94],"we":[95],"current":[98],"techniques":[99],"ECG":[102],"signal":[103],"acquisition,":[104],"processing,":[105],"detection,":[107],"performance":[109],"evaluation":[110],"automated":[112],"detectors.":[114]},"counts_by_year":[{"year":2026,"cited_by_count":2},{"year":2024,"cited_by_count":1},{"year":2022,"cited_by_count":1},{"year":2021,"cited_by_count":2},{"year":2020,"cited_by_count":4},{"year":2019,"cited_by_count":2},{"year":2018,"cited_by_count":3},{"year":2015,"cited_by_count":3},{"year":2014,"cited_by_count":3},{"year":2013,"cited_by_count":2}],"updated_date":"2026-10-31T12:09:11.096373","created_date":"2016-06-24T00:00:00"}
