{"id":"https://openalex.org/W1997254576","doi":"https://doi.org/10.1252/jcej.17.286","title":"Effect of maldistributed fluid on the performance of crossflow dry-cooling towers.","display_name":"Effect of maldistributed fluid on the performance of crossflow dry-cooling towers.","publication_year":1984,"publication_date":"1984-01-01","ids":{"openalex":"https://openalex.org/W1997254576","doi":"https://doi.org/10.1252/jcej.17.286","mag":"1997254576"},"language":"en","primary_location":{"id":"doi:10.1252/jcej.17.286","doi":"https://doi.org/10.1252/jcej.17.286","is_oa":true,"landing_page_url":"https://doi.org/10.1252/jcej.17.286","pdf_url":"https://www.jstage.jst.go.jp/article/jcej1968/17/3/17_3_286/_pdf","source":{"id":"https://openalex.org/S35924701","display_name":"JOURNAL OF CHEMICAL ENGINEERING OF JAPAN","issn_l":"0021-9592","issn":["0021-9592","1881-1299"],"is_oa":false,"is_in_doaj":true,"is_core":true,"listed_in":["cwts-core","doaj","dongbi-c","jufo-1","norway-1","oarl","poland-40","russia-white-list-3"],"host_organization":"https://openalex.org/P4320800608","host_organization_name":"Society of Chemical Engineers, Japan","host_organization_lineage":["https://openalex.org/P4320800608"],"host_organization_lineage_names":["Society of Chemical Engineers, Japan"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"JOURNAL OF CHEMICAL ENGINEERING OF JAPAN","raw_type":"journal-article"},"volume":null,"type":"article","indexed_in":["crossref","doaj"],"open_access":{"is_oa":true,"oa_status":"bronze","oa_url":"https://www.jstage.jst.go.jp/article/jcej1968/17/3/17_3_286/_pdf","any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5106222852","display_name":"Yoshishige Hayashi","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I10091056","display_name":"Kanazawa University","ror":"https://ror.org/02hwp6a56","country_code":"JP","type":"education","lineage":["https://openalex.org/I10091056"]}],"countries":["JP"],"is_corresponding":false,"raw_author_name":"YOSHISHIGE HAYASHI","raw_affiliation_strings":["Department of Chemical Engineering, Kanazawa University"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Chemical Engineering, Kanazawa University","institution_ids":["https://openalex.org/I10091056"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5111769419","display_name":"Eiji Hirai","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I10091056","display_name":"Kanazawa University","ror":"https://ror.org/02hwp6a56","country_code":"JP","type":"education","lineage":["https://openalex.org/I10091056"]}],"countries":["JP"],"is_corresponding":false,"raw_author_name":"EIJI HIRAI","raw_affiliation_strings":["Department of Chemical Engineering, Kanazawa University"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Chemical Engineering, Kanazawa University","institution_ids":["https://openalex.org/I10091056"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I10091056"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":true,"cited_by_count":4,"citation_normalized_percentile":{"value":0.30400083,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"17","issue":"3","first_page":"286","last_page":"292"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10998","display_name":"Heat Transfer and Optimization","score":0.9990000128746033,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10998","display_name":"Heat Transfer and Optimization","score":0.9990000128746033,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12063","display_name":"Heat and Mass Transfer in Porous Media","score":0.00019999999494757503,"subfield":{"id":"https://openalex.org/subfields/2206","display_name":"Computational Mechanics"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12560","display_name":"Nuclear Engineering Thermal-Hydraulics","score":9.999999747378752e-05,"subfield":{"id":"https://openalex.org/subfields/2202","display_name":"Aerospace Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/heat-transfer-rate","display_name":"heat transfer rate","score":0.7229999899864197},{"id":"https://openalex.org/keywords/heat-exchanger-design","display_name":"heat exchanger design","score":0.48399999737739563}],"concepts":[{"id":"https://openalex.org/C2778547687","wikidata":"https://www.wikidata.org/wiki/Q193886","display_name":"Cooling tower","level":3,"score":0.7923336029052734},{"id":"https://openalex.org/C57879066","wikidata":"https://www.wikidata.org/wiki/Q41217","display_name":"Mechanics","level":1,"score":0.7053256034851074},{"id":"https://openalex.org/C50517652","wikidata":"https://www.wikidata.org/wiki/Q179635","display_name":"Heat transfer","level":2,"score":0.6834809184074402},{"id":"https://openalex.org/C97355855","wikidata":"https://www.wikidata.org/wiki/Q11473","display_name":"Thermodynamics","level":1,"score":0.539277970790863},{"id":"https://openalex.org/C2777551473","wikidata":"https://www.wikidata.org/wiki/Q2093072","display_name":"Tube (container)","level":2,"score":0.5345990061759949},{"id":"https://openalex.org/C38349280","wikidata":"https://www.wikidata.org/wiki/Q1434290","display_name":"Flow (mathematics)","level":2,"score":0.4935086965560913},{"id":"https://openalex.org/C107706546","wikidata":"https://www.wikidata.org/wiki/Q189124","display_name":"Heat exchanger","level":2,"score":0.4375873804092407},{"id":"https://openalex.org/C2777831296","wikidata":"https://www.wikidata.org/wiki/Q12518","display_name":"Tower","level":2,"score":0.43325281143188477},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.4174530804157257},{"id":"https://openalex.org/C90278072","wikidata":"https://www.wikidata.org/wiki/Q216320","display_name":"Fluid dynamics","level":2,"score":0.41702455282211304},{"id":"https://openalex.org/C7694927","wikidata":"https://www.wikidata.org/wiki/Q7667810","display_name":"Water cooling","level":2,"score":0.317003458738327},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.26674842834472656},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.1847403645515442},{"id":"https://openalex.org/C66938386","wikidata":"https://www.wikidata.org/wiki/Q633538","display_name":"Structural engineering","level":1,"score":0.1311689019203186},{"id":"https://openalex.org/C159985019","wikidata":"https://www.wikidata.org/wiki/Q181790","display_name":"Composite material","level":1,"score":0.09503403306007385}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1252/jcej.17.286","doi":"https://doi.org/10.1252/jcej.17.286","is_oa":true,"landing_page_url":"https://doi.org/10.1252/jcej.17.286","pdf_url":"https://www.jstage.jst.go.jp/article/jcej1968/17/3/17_3_286/_pdf","source":{"id":"https://openalex.org/S35924701","display_name":"JOURNAL OF CHEMICAL ENGINEERING OF JAPAN","issn_l":"0021-9592","issn":["0021-9592","1881-1299"],"is_oa":false,"is_in_doaj":true,"is_core":true,"listed_in":["cwts-core","doaj","dongbi-c","jufo-1","norway-1","oarl","poland-40","russia-white-list-3"],"host_organization":"https://openalex.org/P4320800608","host_organization_name":"Society of Chemical Engineers, Japan","host_organization_lineage":["https://openalex.org/P4320800608"],"host_organization_lineage_names":["Society of Chemical Engineers, Japan"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"JOURNAL OF CHEMICAL ENGINEERING OF JAPAN","raw_type":"journal-article"}],"best_oa_location":{"id":"doi:10.1252/jcej.17.286","doi":"https://doi.org/10.1252/jcej.17.286","is_oa":true,"landing_page_url":"https://doi.org/10.1252/jcej.17.286","pdf_url":"https://www.jstage.jst.go.jp/article/jcej1968/17/3/17_3_286/_pdf","source":{"id":"https://openalex.org/S35924701","display_name":"JOURNAL OF CHEMICAL ENGINEERING OF JAPAN","issn_l":"0021-9592","issn":["0021-9592","1881-1299"],"is_oa":false,"is_in_doaj":true,"is_core":true,"listed_in":["cwts-core","doaj","dongbi-c","jufo-1","norway-1","oarl","poland-40","russia-white-list-3"],"host_organization":"https://openalex.org/P4320800608","host_organization_name":"Society of Chemical Engineers, Japan","host_organization_lineage":["https://openalex.org/P4320800608"],"host_organization_lineage_names":["Society of Chemical Engineers, Japan"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"JOURNAL OF CHEMICAL ENGINEERING OF JAPAN","raw_type":"journal-article"},"sustainable_development_goals":[{"score":0.4000000059604645,"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":true,"grobid_xml":true},"content_urls":{"pdf":"https://content.openalex.org/works/W1997254576.pdf","grobid_xml":"https://content.openalex.org/works/W1997254576.grobid-xml"},"referenced_works_count":1,"referenced_works":["https://openalex.org/W3133668973"],"related_works":["https://openalex.org/W2021922818","https://openalex.org/W7056209272","https://openalex.org/W2041338722","https://openalex.org/W4365454103","https://openalex.org/W2953978445","https://openalex.org/W1984240715","https://openalex.org/W3026797125","https://openalex.org/W2019568765","https://openalex.org/W575761780","https://openalex.org/W781802882"],"abstract_inverted_index":{"For":[0],"the":[1,13,24,29,32,41,45,57,71,77,81,84,88,94,98],"design":[2],"calculation":[3],"of":[4,16,40,47,73],"crossflow":[5],"dry-cooling":[6],"towers,":[7],"it":[8],"is":[9,22,26,43,53,68,91],"important":[10],"to":[11],"know":[12],"net":[14],"amount":[15],"heat":[17,50,59],"transfer.":[18],"The":[19],"usual":[20],"assumption":[21],"that":[23,63],"flow":[25,67,75],"uniform":[27,66],"through":[28],"tower,":[30],"particularly":[31],"tube":[33],"side.":[34],"In":[35],"this":[36],"study,":[37],"when":[38,56],"one":[39],"fluids":[42],"maldistributed,":[44],"effect":[46,101],"maldistribution":[48,100],"on":[49],"transfer":[51],"rates":[52],"investigated":[54],"and":[55],"same":[58,78],"arrival":[60],"factor":[61],"as":[62],"obtained":[64],"by":[65],"required":[69],"for":[70],"case":[72],"maldistributed":[74],"under":[76,93],"operating":[79],"conditions,":[80],"deviation":[82],"in":[83,96],"overall":[85],"conductance":[86],"between":[87],"two":[89],"cases":[90],"discussed":[92],"conditions":[95],"which":[97],"maximum":[99],"occurs.":[102]},"counts_by_year":[],"updated_date":"2026-10-01T08:54:57.152042","created_date":"2016-06-24T00:00:00"}
