{"id":"https://openalex.org/W1997082284","doi":"https://doi.org/10.1049/piee.1973.0121","title":"Overhead-line parameters for circuit-breaker application","display_name":"Overhead-line parameters for circuit-breaker application","alternate_titles":[],"publication_year":1973,"publication_date":"1973-01-01","ids":{"openalex":"https://openalex.org/W1997082284","doi":"https://doi.org/10.1049/piee.1973.0121","mag":"1997082284"},"language":"en","primary_location":{"id":"doi:10.1049/piee.1973.0121","doi":"https://doi.org/10.1049/piee.1973.0121","is_oa":false,"landing_page_url":"https://doi.org/10.1049/piee.1973.0121","pdf_url":null,"source":{"id":"https://openalex.org/S4210235475","display_name":"Proceedings of the Institution of Electrical Engineers","issn_l":"0020-3270","issn":["0020-3270","2053-7891"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/P4320800662","host_organization_name":"Institution of Electrical Engineers","host_organization_lineage":["https://openalex.org/P4320800662"],"host_organization_lineage_names":["Institution of Electrical Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the Institution of Electrical Engineers","raw_type":"journal-article"},"parent_works":[],"lineage":["https://openalex.org/W1997082284"],"child_works_count":0,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5063162589","display_name":"Edward L. Bolton","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I197610006","display_name":"University of Lagos","ror":"https://ror.org/05rk03822","country_code":"NG","type":"education","lineage":["https://openalex.org/I197610006"]}],"countries":["NG"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"E. Bolton","raw_affiliation_strings":["Faculty of Engineering, University of Lagos, Lagos, Nigeria","University of Lagos, Faculty of Engineering, Lagos, Nigeria"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Faculty of Engineering, University of Lagos, Lagos, Nigeria","institution_ids":["https://openalex.org/I197610006"]},{"raw_affiliation_string":"University of Lagos, Faculty of Engineering, Lagos, Nigeria","institution_ids":["https://openalex.org/I197610006"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5030731788","display_name":"D. Birtwhistle","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I160993911","display_name":"Queensland University of Technology","ror":"https://ror.org/03pnv4752","country_code":"AU","type":"education","lineage":["https://openalex.org/I160993911"]}],"countries":["AU"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"D. Birtwhistle","raw_affiliation_strings":["Queensland Institute of Technology, Brisbane, Australia"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Queensland Institute of Technology, Brisbane, Australia","institution_ids":["https://openalex.org/I160993911"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5001825931","display_name":"P. Bownes","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"P. Bownes","raw_affiliation_strings":[", Hebburn, UK"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":", Hebburn, UK","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5062022257","display_name":"M.G. Dwek","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I56030857","display_name":"Central Electricity Generating Board","ror":"https://ror.org/01a4t3393","country_code":"GB","type":"government","lineage":["https://openalex.org/I56030857"]}],"countries":["GB"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"M.G. Dwek","raw_affiliation_strings":["Planning Department, System Technical Branch, Central Electricity Generating Board, London, UK","Central Electricity Generating Board, Planning Department, System Technical Branch, London, UK"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Planning Department, System Technical Branch, Central Electricity Generating Board, London, UK","institution_ids":["https://openalex.org/I56030857"]},{"raw_affiliation_string":"Central Electricity Generating Board, Planning Department, System Technical Branch, London, UK","institution_ids":["https://openalex.org/I56030857"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5000453415","display_name":"G.W. Routledge","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"G.W. Routledge","raw_affiliation_strings":["Switchgear Division, Research Department, A. Reyrolle & Co., Hebburn, UK","A. Reyrolle & Co., Switchgear Division, Research Department, Hebburn, UK"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Switchgear Division, Research Department, A. Reyrolle & Co., Hebburn, UK","institution_ids":[]},{"raw_affiliation_string":"A. Reyrolle & Co., Switchgear Division, Research Department, Hebburn, UK","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":3,"institutions_distinct_count":3,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.5699,"has_fulltext":false,"cited_by_count":3,"reviewed_by_count":0,"citation_normalized_percentile":{"value":0.62198258,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":87,"max":93},"biblio":{"volume":"120","issue":"5","first_page":"561","last_page":"561"},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T14502","display_name":"High-Voltage Power Transmission Systems","score":0.9940999746322632,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T14502","display_name":"High-Voltage Power Transmission Systems","score":0.9940999746322632,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12804","display_name":"Thermal Analysis in Power Transmission","score":0.0013000000035390258,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10511","display_name":"High voltage insulation and dielectric phenomena","score":0.0010000000474974513,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/overhead-transmission-lines","display_name":"overhead transmission lines","score":0.9269999861717224},{"id":"https://openalex.org/keywords/circuit-breakers","display_name":"circuit breakers","score":0.8410000205039978},{"id":"https://openalex.org/keywords/surge-impedance","display_name":"surge impedance","score":0.8650000095367432},{"id":"https://openalex.org/keywords/line-model","display_name":"line model","score":0.5139999985694885},{"id":"https://openalex.org/keywords/tower-grounding-resistance","display_name":"tower grounding resistance","score":0.8410000205039978},{"id":"https://openalex.org/keywords/soil-resistivity","display_name":"soil resistivity","score":0.9380000233650208},{"id":"https://openalex.org/keywords/rate-of-rise-of-recovery-voltage","display_name":"rate of rise of recovery voltage","score":0.9549999833106995},{"id":"https://openalex.org/keywords/short-circuit","display_name":"short circuit","score":0.5870000123977661},{"id":"https://openalex.org/keywords/line-height","display_name":"line height","score":0.44699999690055847}],"concepts":[{"id":"https://openalex.org/C61352017","wikidata":"https://www.wikidata.org/wiki/Q211058","display_name":"Circuit breaker","level":2,"score":0.7906193733215332},{"id":"https://openalex.org/C29210110","wikidata":"https://www.wikidata.org/wiki/Q177897","display_name":"Inductance","level":3,"score":0.6953551769256592},{"id":"https://openalex.org/C198352243","wikidata":"https://www.wikidata.org/wiki/Q37105","display_name":"Line (geometry)","level":2,"score":0.6160470247268677},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.5864694118499756},{"id":"https://openalex.org/C17829176","wikidata":"https://www.wikidata.org/wiki/Q179043","display_name":"Electrical impedance","level":2,"score":0.5634809136390686},{"id":"https://openalex.org/C154108245","wikidata":"https://www.wikidata.org/wiki/Q287381","display_name":"Surge","level":2,"score":0.5369991660118103},{"id":"https://openalex.org/C2779960059","wikidata":"https://www.wikidata.org/wiki/Q7113681","display_name":"Overhead (engineering)","level":2,"score":0.529930055141449},{"id":"https://openalex.org/C2775861652","wikidata":"https://www.wikidata.org/wiki/Q110701","display_name":"Overhead line","level":2,"score":0.5032212138175964},{"id":"https://openalex.org/C68583231","wikidata":"https://www.wikidata.org/wiki/Q206907","display_name":"Short circuit","level":3,"score":0.49864888191223145},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.47977739572525024},{"id":"https://openalex.org/C2780799671","wikidata":"https://www.wikidata.org/wiki/Q17087362","display_name":"Transient (computer programming)","level":2,"score":0.44318053126335144},{"id":"https://openalex.org/C141490761","wikidata":"https://www.wikidata.org/wiki/Q5384728","display_name":"Equivalent series inductance","level":4,"score":0.4367738366127014},{"id":"https://openalex.org/C23572009","wikidata":"https://www.wikidata.org/wiki/Q964981","display_name":"Equivalent circuit","level":3,"score":0.43610742688179016},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.4040864408016205},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.21271267533302307},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.17442002892494202},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1049/piee.1973.0121","doi":"https://doi.org/10.1049/piee.1973.0121","is_oa":false,"landing_page_url":"https://doi.org/10.1049/piee.1973.0121","pdf_url":null,"source":{"id":"https://openalex.org/S4210235475","display_name":"Proceedings of the Institution of Electrical Engineers","issn_l":"0020-3270","issn":["0020-3270","2053-7891"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/P4320800662","host_organization_name":"Institution of Electrical Engineers","host_organization_lineage":["https://openalex.org/P4320800662"],"host_organization_lineage_names":["Institution of Electrical Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the Institution of Electrical Engineers","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/9","display_name":"Industry, innovation and infrastructure","score":0.7207000255584717}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":8,"referenced_works":["https://openalex.org/W1966944447","https://openalex.org/W2021631117","https://openalex.org/W2033906776","https://openalex.org/W2046207498","https://openalex.org/W2057332524","https://openalex.org/W2069998161","https://openalex.org/W2072701345","https://openalex.org/W2134996887"],"related_works":["https://openalex.org/W4403464257","https://openalex.org/W2130858475","https://openalex.org/W4254063954","https://openalex.org/W4401621720","https://openalex.org/W2093549563","https://openalex.org/W4402052851","https://openalex.org/W2137214057","https://openalex.org/W2012220168","https://openalex.org/W2091127609","https://openalex.org/W2084331388"],"abstract_inverted_index":{"The":[0],"paper":[1],"presents":[2],"the":[3,38,47,50,67,84,97,116,127,135,143,162,181],"results":[4,68],"of":[5,9,21,58,69,99,115,118,142,153,164,183,185],"a":[6,14,55,159],"comprehensive":[7],"series":[8],"measurements":[10,78],"and":[11,66,72,76,89,107],"calculations":[12,39],"by":[13],"collaborative":[15],"committee":[16],"aimed":[17],"at":[18],"determining":[19],"values":[20,81],"overhead-line":[22],"parameters":[23,101],"(particularly":[24],"for":[25,83,134],"lines":[26,92],"1\u20138":[27],"km":[28],"long),":[29],"significant":[30],"in":[31,37,156],"circuit-breaker":[32,160],"application.":[33],"Line":[34],"models":[35,48],"used":[36],"are":[40,43,64,93],"discussed,":[41],"as":[42,49,103],"refinements":[44],"made":[45,114],"to":[46,53,125,168,175],"work":[51],"progressed":[52],"give":[54],"final":[56],"accuracy":[57],"calculation":[59],"within":[60],"\u00b15%.":[61],"Measurement":[62],"techniques":[63],"described,":[65],"surge":[70,148],"impedance":[71],"50":[73,128],"Hz":[74,129],"inductance":[75,130],"resistance":[77,141],"presented.":[79],"Typical":[80],"calculated":[82],"CEGB":[85],"standard":[86],"275":[87],"kV":[88,91],"400":[90],"given,":[94],"together":[95],"with":[96],"effect":[98,117,163],"varying":[100],"such":[102],"frequency,":[104],"line":[105,137],"height":[106],"earth":[108],"resistivity.":[109],"A":[110],"particular":[111],"study":[112],"was":[113,123],"high":[119],"tower-footing":[120],"resistance,":[121],"which":[122],"found":[124],"increase":[126],"per":[131],"unit":[132],"length":[133],"shorter":[136],"lengths.":[138],"High":[139],"footing":[140],"sending-end":[144],"tower":[145],"also":[146],"increases":[147,180],"impedance,":[149],"but":[150],"this":[151],"is":[152,173],"no":[154],"importance":[155],"practice.":[157],"From":[158],"viewpoint,":[161],"subconductors":[165],"touching":[166],"due":[167],"attraction":[169],"under":[170],"short":[171],"circuit":[172],"shown":[174],"be":[176],"significant,":[177],"since":[178],"it":[179],"rate":[182],"rise":[184],"transient":[186],"recovery":[187],"voltage.":[188]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W1997082284","counts_by_year":[{"year":2017,"cited_by_count":1}],"updated_date":"2026-11-07T11:25:07.637180","created_date":"2016-06-24T00:00:00"}
