{"id":"https://openalex.org/W1995692653","doi":"https://doi.org/10.15554/pcij.11011999.42.67","title":"Preliminary Results and Conclusions From the PRESSS Five-Story Precast Concrete Test Building","display_name":"Preliminary Results and Conclusions From the PRESSS Five-Story Precast Concrete Test Building","publication_year":1999,"publication_date":"1999-11-01","ids":{"openalex":"https://openalex.org/W1995692653","doi":"https://doi.org/10.15554/pcij.11011999.42.67","mag":"1995692653"},"language":"en","primary_location":{"id":"doi:10.15554/pcij.11011999.42.67","doi":"https://doi.org/10.15554/pcij.11011999.42.67","is_oa":false,"landing_page_url":"https://doi.org/10.15554/pcij.11011999.42.67","pdf_url":null,"source":{"id":"https://openalex.org/S133991097","display_name":"PCI Journal","issn_l":"0887-9672","issn":["0887-9672"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":["dongbi-b","jufo-1","poland-40"],"host_organization":"https://openalex.org/P4360969233","host_organization_name":"Precast/Prestressed Concrete Institute","host_organization_lineage":["https://openalex.org/P4360969233"],"host_organization_lineage_names":["Precast/Prestressed Concrete Institute"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"PCI Journal","raw_type":"journal-article"},"volume":null,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5112198422","display_name":"M. J. N. Priestley","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"M. J. Nigel Priestley","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5055384120","display_name":"Sri Sritharan","orcid":"https://orcid.org/0000-0001-9941-8156","observed_orcids":["https://orcid.org/0000-0001-9941-8156"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"S. (Sri) Sritharan","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5020701604","display_name":"James R. Conley","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"James R. Conley","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"last","author":{"id":"https://openalex.org/A5036987203","display_name":"Stefano Pampanin","orcid":"https://orcid.org/0000-0002-2714-6697","observed_orcids":["https://orcid.org/0000-0002-2714-6697"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Stefano Stefano Pampanin","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":27.5379,"has_fulltext":false,"cited_by_count":875,"citation_normalized_percentile":{"value":0.99688522,"is_in_top_1_percent":true,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":99,"max":100},"biblio":{"volume":"44","issue":"6","first_page":"42","last_page":"67"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10160","display_name":"Seismic Performance and Analysis","score":0.9970999956130981,"subfield":{"id":"https://openalex.org/subfields/2205","display_name":"Civil and Structural Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10160","display_name":"Seismic Performance and Analysis","score":0.9970999956130981,"subfield":{"id":"https://openalex.org/subfields/2205","display_name":"Civil and Structural Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10479","display_name":"Structural Behavior of Reinforced Concrete","score":0.0007999999797903001,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11874","display_name":"Structural Response to Dynamic Loads","score":0.0005000000237487257,"subfield":{"id":"https://openalex.org/subfields/2205","display_name":"Civil and Structural Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/precast-concrete-buildings","display_name":"precast concrete buildings","score":0.8679999709129333},{"id":"https://openalex.org/keywords/seismic-testing","display_name":"seismic testing","score":0.6140000224113464},{"id":"https://openalex.org/keywords/displacement-based-design","display_name":"displacement-based design","score":0.6660000085830688},{"id":"https://openalex.org/keywords/shear-walls","display_name":"shear walls","score":0.671999990940094},{"id":"https://openalex.org/keywords/residual-drift","display_name":"residual drift","score":0.609000027179718},{"id":"https://openalex.org/keywords/strength-degradation","display_name":"strength degradation","score":0.46799999475479126}],"concepts":[{"id":"https://openalex.org/C125450124","wikidata":"https://www.wikidata.org/wiki/Q831541","display_name":"Precast concrete","level":2,"score":0.9903290271759033},{"id":"https://openalex.org/C2777267654","wikidata":"https://www.wikidata.org/wiki/Q3519023","display_name":"Test (biology)","level":2,"score":0.6078693866729736},{"id":"https://openalex.org/C66938386","wikidata":"https://www.wikidata.org/wiki/Q633538","display_name":"Structural engineering","level":1,"score":0.4392533004283905},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.36125779151916504},{"id":"https://openalex.org/C77595967","wikidata":"https://www.wikidata.org/wiki/Q3151013","display_name":"Forensic engineering","level":1,"score":0.3500494062900543},{"id":"https://openalex.org/C170154142","wikidata":"https://www.wikidata.org/wiki/Q150737","display_name":"Architectural engineering","level":1,"score":0.32764267921447754},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.27120286226272583},{"id":"https://openalex.org/C151730666","wikidata":"https://www.wikidata.org/wiki/Q7205","display_name":"Paleontology","level":1,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.15554/pcij.11011999.42.67","doi":"https://doi.org/10.15554/pcij.11011999.42.67","is_oa":false,"landing_page_url":"https://doi.org/10.15554/pcij.11011999.42.67","pdf_url":null,"source":{"id":"https://openalex.org/S133991097","display_name":"PCI Journal","issn_l":"0887-9672","issn":["0887-9672"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":["dongbi-b","jufo-1","poland-40"],"host_organization":"https://openalex.org/P4360969233","host_organization_name":"Precast/Prestressed Concrete Institute","host_organization_lineage":["https://openalex.org/P4360969233"],"host_organization_lineage_names":["Precast/Prestressed Concrete Institute"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"PCI Journal","raw_type":"journal-article"},{"id":"pmh:oai:iris.uniroma1.it:11573/1182958","doi":null,"is_oa":false,"landing_page_url":"http://hdl.handle.net/11573/1182958","pdf_url":null,"source":{"id":"https://openalex.org/S4377196107","display_name":"IRIS Research product catalog (Sapienza University of Rome)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"info:eu-repo/semantics/article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Industry, innovation and infrastructure","id":"https://metadata.un.org/sdg/9","score":0.651199996471405},{"display_name":"Sustainable cities and communities","id":"https://metadata.un.org/sdg/11","score":0.5142999887466431}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":6,"referenced_works":["https://openalex.org/W1504392525","https://openalex.org/W1560353342","https://openalex.org/W2020969540","https://openalex.org/W2087377136","https://openalex.org/W2156320181","https://openalex.org/W2328813472"],"related_works":["https://openalex.org/W2320654375","https://openalex.org/W2328813472","https://openalex.org/W1986236033","https://openalex.org/W2317745256","https://openalex.org/W94250696","https://openalex.org/W7115722012","https://openalex.org/W228980564","https://openalex.org/W4385613069","https://openalex.org/W2594410733","https://openalex.org/W4386695395"],"abstract_inverted_index":{"A":[0],"large-scale":[1],"five-story":[2],"precast":[3],"concrete":[4],"building":[5,31],"constructed":[6],"to":[7,59,64,110,114,136],"60":[8],"percent":[9,68,120],"scale":[10],"was":[11,57,86],"tested":[12],"under":[13],"simulated":[14],"seismic":[15,60],"loading":[16],"as":[17],"the":[18,21,51,84,94,104,123,130,138,143,152],"culmination":[19],"of":[20,42,83,151],"10-year":[22],"PRESSS":[23],"(Precast":[24],"Seismic":[25,78],"Structural":[26],"Systems)":[27],"research":[28],"program.":[29],"The":[30,54,81,127],"comprised":[32],"four":[33],"different":[34],"ductile":[35],"structural":[36,47],"frame":[37,105],"systems":[38],"in":[39,50,93,103],"one":[40],"direction":[41],"response":[43],"and":[44,98,141,146],"a":[45],"jointed":[46],"wall":[48,96],"system":[49],"orthogonal":[52],"direction.":[53],"test":[55,128],"structure":[56,85],"subjected":[58],"input":[61],"levels":[62,112],"equivalent":[63],"at":[65],"least":[66],"50":[67],"higher":[69,121],"than":[70,118,122],"those":[71],"required":[72,139],"for":[73],"UBC":[74],"(Uniform":[75],"Building":[76],"Code)":[77],"Zone":[79],"4.":[80],"behavior":[82],"extremely":[87],"satisfactory,":[88],"with":[89],"only":[90],"minimal":[91],"damage":[92,145],"shear":[95],"direction,":[97,106],"no":[99],"significant":[100],"strength":[101,140],"loss":[102],"despite":[107],"being":[108],"taken":[109],"drift":[111,125,149],"up":[113],"4.5":[115],"percent,":[116],"more":[117],"100":[119],"design":[124],"level.":[126],"validated":[129],"Displacement-Based":[131],"Design":[132],"(DBD)":[133],"approach":[134],"used":[135],"determine":[137],"confirmed":[142],"low":[144,147],"residual":[148],"expected":[150],"building.":[153]},"counts_by_year":[{"year":2026,"cited_by_count":60},{"year":2025,"cited_by_count":66},{"year":2024,"cited_by_count":72},{"year":2023,"cited_by_count":74},{"year":2022,"cited_by_count":64},{"year":2021,"cited_by_count":63},{"year":2020,"cited_by_count":59},{"year":2019,"cited_by_count":38},{"year":2018,"cited_by_count":44},{"year":2017,"cited_by_count":45},{"year":2016,"cited_by_count":35},{"year":2015,"cited_by_count":28},{"year":2014,"cited_by_count":25},{"year":2013,"cited_by_count":22},{"year":2012,"cited_by_count":24}],"updated_date":"2026-11-05T12:25:35.769452","created_date":"2016-06-24T00:00:00"}