{"id":"https://openalex.org/W1995604395","doi":"https://doi.org/10.1016/j.engfailanal.2010.11.007","title":"Failure analysis of shear columns to seismic events","display_name":"Failure analysis of shear columns to seismic events","publication_year":2010,"publication_date":"2010-12-14","ids":{"openalex":"https://openalex.org/W1995604395","doi":"https://doi.org/10.1016/j.engfailanal.2010.11.007","mag":"1995604395"},"language":"en","primary_location":{"id":"doi:10.1016/j.engfailanal.2010.11.007","doi":"https://doi.org/10.1016/j.engfailanal.2010.11.007","is_oa":false,"landing_page_url":"https://doi.org/10.1016/j.engfailanal.2010.11.007","pdf_url":null,"source":{"id":"https://openalex.org/S152303250","display_name":"Engineering Failure Analysis","issn_l":"1350-6307","issn":["1350-6307","1873-1961"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["anvur-scientific","cwts-core","dongbi-b","jufo-1","ki-jl-1","norway-1","poland-100","russia-white-list-1","vabb-shw"],"host_organization":"https://openalex.org/P4310320990","host_organization_name":"Elsevier BV","host_organization_lineage":["https://openalex.org/P4310320990"],"host_organization_lineage_names":["Elsevier BV"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Engineering Failure Analysis","raw_type":"journal-article"},"volume":null,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5111685938","display_name":"Mizam Do\u011fan","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I51209816","display_name":"Eski\u015fehir Osmangazi University","ror":"https://ror.org/01dzjez04","country_code":"TR","type":"education","lineage":["https://openalex.org/I51209816"]}],"countries":["TR"],"is_corresponding":true,"raw_author_name":"Mizam Dogan","raw_affiliation_strings":["Eskisehir Osmangazi University, Civil Engineering Dept., 26480 Eskisehir, Turkey"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Eskisehir Osmangazi University, Civil Engineering Dept., 26480 Eskisehir, Turkey","institution_ids":["https://openalex.org/I51209816"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":["https://openalex.org/A5111685938"],"corresponding_institution_ids":["https://openalex.org/I51209816"],"apc_list":{"value":3820,"currency":"USD","value_usd":3820},"apc_paid":null,"fwci":2.9161,"has_fulltext":false,"cited_by_count":11,"citation_normalized_percentile":{"value":0.89760923,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":88,"max":97},"biblio":{"volume":"18","issue":"2","first_page":"682","last_page":"693"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10160","display_name":"Seismic Performance and Analysis","score":0.5702999830245972,"subfield":{"id":"https://openalex.org/subfields/2205","display_name":"Civil and Structural Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10160","display_name":"Seismic Performance and Analysis","score":0.5702999830245972,"subfield":{"id":"https://openalex.org/subfields/2205","display_name":"Civil and Structural Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10479","display_name":"Structural Behavior of Reinforced Concrete","score":0.3149000108242035,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13852","display_name":"Seismic and Structural Analysis of Tall Buildings","score":0.0706000030040741,"subfield":{"id":"https://openalex.org/subfields/2205","display_name":"Civil and Structural Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/short-columns","display_name":"short columns","score":0.968999981880188},{"id":"https://openalex.org/keywords/seismic-failure","display_name":"seismic failure","score":0.7509999871253967},{"id":"https://openalex.org/keywords/earthquake-damage","display_name":"earthquake damage","score":0.7799999713897705},{"id":"https://openalex.org/keywords/column-height","display_name":"column height","score":0.5450000166893005},{"id":"https://openalex.org/keywords/stirrup-spacing","display_name":"stirrup spacing","score":0.6110000014305115},{"id":"https://openalex.org/keywords/shear-stress","display_name":"shear stress","score":0.6990000009536743},{"id":"https://openalex.org/keywords/floor-height","display_name":"floor height","score":0.3959999978542328},{"id":"https://openalex.org/keywords/building-regulations","display_name":"building regulations","score":0.5889999866485596}],"concepts":[{"id":"https://openalex.org/C2776021025","wikidata":"https://www.wikidata.org/wiki/Q191657","display_name":"Stirrup","level":2,"score":0.8610318899154663},{"id":"https://openalex.org/C2780551164","wikidata":"https://www.wikidata.org/wiki/Q2306599","display_name":"Column (typography)","level":3,"score":0.6770151853561401},{"id":"https://openalex.org/C66938386","wikidata":"https://www.wikidata.org/wiki/Q633538","display_name":"Structural engineering","level":1,"score":0.655463695526123},{"id":"https://openalex.org/C96035792","wikidata":"https://www.wikidata.org/wiki/Q43606218","display_name":"Shear (geology)","level":2,"score":0.595106303691864},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.5492916703224182},{"id":"https://openalex.org/C187320778","wikidata":"https://www.wikidata.org/wiki/Q1349130","display_name":"Geotechnical engineering","level":1,"score":0.49105000495910645},{"id":"https://openalex.org/C22140971","wikidata":"https://www.wikidata.org/wiki/Q7492174","display_name":"Shear force","level":2,"score":0.4730460047721863},{"id":"https://openalex.org/C179254644","wikidata":"https://www.wikidata.org/wiki/Q13222844","display_name":"Moment (physics)","level":2,"score":0.46635615825653076},{"id":"https://openalex.org/C123060433","wikidata":"https://www.wikidata.org/wiki/Q2026731","display_name":"Seismic loading","level":2,"score":0.42169415950775146},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2612127661705017},{"id":"https://openalex.org/C13355873","wikidata":"https://www.wikidata.org/wiki/Q2920850","display_name":"Connection (principal bundle)","level":2,"score":0.10144570469856262},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.05754157900810242},{"id":"https://openalex.org/C5900021","wikidata":"https://www.wikidata.org/wiki/Q163082","display_name":"Petrology","level":1,"score":0.0},{"id":"https://openalex.org/C74650414","wikidata":"https://www.wikidata.org/wiki/Q11397","display_name":"Classical mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1016/j.engfailanal.2010.11.007","doi":"https://doi.org/10.1016/j.engfailanal.2010.11.007","is_oa":false,"landing_page_url":"https://doi.org/10.1016/j.engfailanal.2010.11.007","pdf_url":null,"source":{"id":"https://openalex.org/S152303250","display_name":"Engineering Failure Analysis","issn_l":"1350-6307","issn":["1350-6307","1873-1961"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["anvur-scientific","cwts-core","dongbi-b","jufo-1","ki-jl-1","norway-1","poland-100","russia-white-list-1","vabb-shw"],"host_organization":"https://openalex.org/P4310320990","host_organization_name":"Elsevier BV","host_organization_lineage":["https://openalex.org/P4310320990"],"host_organization_lineage_names":["Elsevier BV"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Engineering Failure Analysis","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.7250000238418579,"id":"https://metadata.un.org/sdg/11","display_name":"Sustainable cities and communities"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":6,"referenced_works":["https://openalex.org/W1969760883","https://openalex.org/W2025407404","https://openalex.org/W2068208639","https://openalex.org/W2090330885","https://openalex.org/W2100568570","https://openalex.org/W2915625080"],"related_works":["https://openalex.org/W7117480612","https://openalex.org/W2381435179","https://openalex.org/W4324057000","https://openalex.org/W1822526270","https://openalex.org/W2015391136","https://openalex.org/W2095396312","https://openalex.org/W2381760887","https://openalex.org/W2376844590","https://openalex.org/W2388537391","https://openalex.org/W4412755634"],"abstract_inverted_index":null,"counts_by_year":[{"year":2026,"cited_by_count":3},{"year":2019,"cited_by_count":1},{"year":2018,"cited_by_count":1},{"year":2016,"cited_by_count":1},{"year":2015,"cited_by_count":2},{"year":2013,"cited_by_count":2},{"year":2012,"cited_by_count":1}],"updated_date":"2026-11-10T11:39:43.021295","created_date":"2016-06-24T00:00:00"}
