{"id":"https://openalex.org/W1994200212","doi":"https://doi.org/10.2118/57057-pa","title":"Reliability Analysis of Permanent Downhole Monitoring Systems","display_name":"Reliability Analysis of Permanent Downhole Monitoring Systems","alternate_titles":[],"publication_year":2001,"publication_date":"2001-03-01","ids":{"openalex":"https://openalex.org/W1994200212","doi":"https://doi.org/10.2118/57057-pa","mag":"1994200212"},"language":"en","primary_location":{"id":"doi:10.2118/57057-pa","doi":"https://doi.org/10.2118/57057-pa","is_oa":false,"landing_page_url":"https://doi.org/10.2118/57057-pa","pdf_url":null,"source":{"id":"https://openalex.org/S4210174741","display_name":"SPE Drilling & Completion","issn_l":"1064-6671","issn":["1064-6671","1930-0204"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","jufo-1","norway-1","poland-100","russia-white-list-1"],"host_organization":"https://openalex.org/P4322614974","host_organization_name":"Society of Petroleum Engineers","host_organization_lineage":["https://openalex.org/P4322614974"],"host_organization_lineage_names":["Society of Petroleum Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"SPE Drilling &amp; Completion","raw_type":"journal-article"},"parent_works":[],"lineage":["https://openalex.org/W1994200212"],"child_works_count":0,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5087009898","display_name":"S. J. C. H. M. van Gisbergen","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I7923278","display_name":"Shell (Netherlands)","ror":"https://ror.org/00b5m4j81","country_code":"NL","type":"company","lineage":["https://openalex.org/I7923278"]}],"countries":["NL"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"S. J. C. H. M. van Gisbergen","raw_affiliation_strings":["Shell Intl. Deepwater Services B.V"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Shell Intl. Deepwater Services B.V","institution_ids":["https://openalex.org/I7923278"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5062073358","display_name":"A. A. H. Vandeweijer","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I7923278","display_name":"Shell (Netherlands)","ror":"https://ror.org/00b5m4j81","country_code":"NL","type":"company","lineage":["https://openalex.org/I7923278"]}],"countries":["NL"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"A. A. H. Vandeweijer","raw_affiliation_strings":["Shell Intl. E&P B.V"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Shell Intl. E&P B.V","institution_ids":["https://openalex.org/I7923278"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I7923278"],"apc_list":null,"apc_paid":null,"fwci":3.6137,"has_fulltext":false,"cited_by_count":34,"reviewed_by_count":0,"citation_normalized_percentile":{"value":0.89719145,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":86,"max":97},"biblio":{"volume":"16","issue":"01","first_page":"60","last_page":"63"},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T13050","display_name":"Oil and Gas Production Techniques","score":0.6685000061988831,"subfield":{"id":"https://openalex.org/subfields/2103","display_name":"Fuel Technology"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T13050","display_name":"Oil and Gas Production Techniques","score":0.6685000061988831,"subfield":{"id":"https://openalex.org/subfields/2103","display_name":"Fuel Technology"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10780","display_name":"Reliability and Maintenance Optimization","score":0.2741999924182892,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10892","display_name":"Drilling and Well Engineering","score":0.03440000116825104,"subfield":{"id":"https://openalex.org/subfields/2103","display_name":"Fuel Technology"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/permanent-downhole-gauges","display_name":"permanent downhole gauges","score":0.9430000185966492},{"id":"https://openalex.org/keywords/system-reliability","display_name":"system reliability","score":0.8149999976158142},{"id":"https://openalex.org/keywords/survival-probability","display_name":"survival probability","score":0.7300000190734863},{"id":"https://openalex.org/keywords/failure-modes","display_name":"failure modes","score":0.8899999856948853},{"id":"https://openalex.org/keywords/downhole-gauges","display_name":"downhole gauges","score":0.6610000133514404},{"id":"https://openalex.org/keywords/cable-failure","display_name":"cable failure","score":0.5929999947547913},{"id":"https://openalex.org/keywords/smart-wells","display_name":"smart wells","score":0.9829999804496765},{"id":"https://openalex.org/keywords/temperature-and-pressure-monitoring","display_name":"temperature and pressure monitoring","score":0.8600000143051147},{"id":"https://openalex.org/keywords/oil-and-gas-wells","display_name":"oil and gas wells","score":0.8389999866485596},{"id":"https://openalex.org/keywords/reservoir-management","display_name":"reservoir management","score":0.7390000224113464}],"concepts":[{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.7741953134536743},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.6289920210838318},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.6135811805725098},{"id":"https://openalex.org/C78762247","wikidata":"https://www.wikidata.org/wiki/Q1273174","display_name":"Petroleum engineering","level":1,"score":0.39419665932655334},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.2118/57057-pa","doi":"https://doi.org/10.2118/57057-pa","is_oa":false,"landing_page_url":"https://doi.org/10.2118/57057-pa","pdf_url":null,"source":{"id":"https://openalex.org/S4210174741","display_name":"SPE Drilling & Completion","issn_l":"1064-6671","issn":["1064-6671","1930-0204"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","jufo-1","norway-1","poland-100","russia-white-list-1"],"host_organization":"https://openalex.org/P4322614974","host_organization_name":"Society of Petroleum Engineers","host_organization_lineage":["https://openalex.org/P4322614974"],"host_organization_lineage_names":["Society of Petroleum Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"SPE Drilling &amp; Completion","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":2,"referenced_works":["https://openalex.org/W2007913975","https://openalex.org/W2075762856"],"related_works":["https://openalex.org/W2006497312","https://openalex.org/W4393204668","https://openalex.org/W7142710744","https://openalex.org/W4313056538","https://openalex.org/W2999299469","https://openalex.org/W4415777336","https://openalex.org/W1520893967","https://openalex.org/W2002693090","https://openalex.org/W2322906099","https://openalex.org/W4404013966"],"abstract_inverted_index":{"Summary":[0],"Permanent":[1],"downhole":[2,26,118],"gauge":[3,119],"(PDG)":[4],"systems":[5,16,30,59,69,74],"have":[6,89,108,129],"been":[7,90,109,130],"installed":[8,33,60,75],"in":[9,34,76,95],"many":[10],"oil":[11],"and":[12,20,28,57,111,120],"gas":[13],"wells.":[14],"These":[15],"improve":[17],"reservoir":[18],"management":[19],"production":[21],"optimization.":[22],"Currently,":[23],"more":[24],"complex":[25],"monitoring":[27],"control":[29],"are":[31,36],"being":[32],"what":[35],"often":[37],"called":[38],"\"Intelligent":[39],"Wells.\"":[40],"Reliability":[41],"is":[42],"a":[43,96],"critical":[44],"aspect":[45],"for":[46,73,82,102],"all":[47],"these":[48,68,126],"systems.":[49],"We":[50],"evaluated":[51,110],"the":[52,77,83,103,117,122],"performance":[53],"of":[54,67,100],"952":[55],"pressure-":[56],"temperaturemonitoring":[58],"since":[61],"1987.":[62],"The":[63],"5-year":[64,97],"survival":[65,98],"probability":[66,99],"improved":[70],"from":[71,92],"40%":[72],"period":[78,84,104],"1987\u201388":[79],"to":[80,116,121,132],"75%":[81],"1991\u201392.":[85],"No":[86],"further":[87],"improvements":[88],"observed":[91],"1992,":[93],"resulting":[94],"69%":[101],"1993\u201398.":[105],"Failure":[106],"modes":[107],"could":[112],"be":[113],"attributed":[114],"primarily":[115],"cable.":[123],"Based":[124],"on":[125],"findings,":[127],"recommendations":[128],"made":[131],"achieve":[133],"reliability":[134],"improvements.":[135]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W1994200212","counts_by_year":[{"year":2026,"cited_by_count":3},{"year":2025,"cited_by_count":2},{"year":2024,"cited_by_count":1},{"year":2022,"cited_by_count":4},{"year":2017,"cited_by_count":1},{"year":2016,"cited_by_count":4},{"year":2015,"cited_by_count":1},{"year":2014,"cited_by_count":1},{"year":2013,"cited_by_count":2},{"year":2012,"cited_by_count":2}],"updated_date":"2026-11-16T12:05:36.265796","created_date":"2016-06-24T00:00:00"}
