{"id":"https://openalex.org/W1984115409","doi":"https://doi.org/10.1109/pes.2010.5589774","title":"Regulation and frequency response service capability of modern wind power plants","display_name":"Regulation and frequency response service capability of modern wind power plants","publication_year":2010,"publication_date":"2010-07-01","ids":{"openalex":"https://openalex.org/W1984115409","doi":"https://doi.org/10.1109/pes.2010.5589774","mag":"1984115409"},"language":"en","primary_location":{"id":"doi:10.1109/pes.2010.5589774","doi":"https://doi.org/10.1109/pes.2010.5589774","is_oa":false,"landing_page_url":"https://doi.org/10.1109/pes.2010.5589774","pdf_url":null,"source":{"id":"https://openalex.org/S4210212590","display_name":"IEEE Power Engineering Society General Meeting","issn_l":"1932-5517","issn":["1932-5517","2693-7891"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core"],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE PES General Meeting","raw_type":"proceedings-article"},"volume":null,"type":"conference-paper","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5019561260","display_name":"Germ\u00e1n Claudio Tarnowski","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I43275575","display_name":"Vestas (Denmark)","ror":"https://ror.org/003pdcw24","country_code":"DK","type":"company","lineage":["https://openalex.org/I43275575"]},{"id":"https://openalex.org/I96673099","display_name":"Technical University of Denmark","ror":"https://ror.org/04qtj9h94","country_code":"DK","type":"education","lineage":["https://openalex.org/I96673099"]}],"countries":["DK"],"is_corresponding":false,"raw_author_name":"German Claudio Tarnowski","raw_affiliation_strings":["Centre for Electric Technology, Technical University of Denmark, Denmark","Vestas Wind Systems A/S, Denmark"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Centre for Electric Technology, Technical University of Denmark, Denmark","institution_ids":["https://openalex.org/I96673099"]},{"raw_affiliation_string":"Vestas Wind Systems A/S, Denmark","institution_ids":["https://openalex.org/I43275575"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5108647927","display_name":"Philip Carne Kj\u00e6r","orcid":"https://orcid.org/0000-0002-7398-160X","observed_orcids":["https://orcid.org/0000-0002-7398-160X"]},"institutions":[{"id":"https://openalex.org/I43275575","display_name":"Vestas (Denmark)","ror":"https://ror.org/003pdcw24","country_code":"DK","type":"company","lineage":["https://openalex.org/I43275575"]}],"countries":["DK"],"is_corresponding":false,"raw_author_name":"Philip Carne Kj\u00e6r","raw_affiliation_strings":["Vestas Wind Systems A/S, Denmark"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Vestas Wind Systems A/S, Denmark","institution_ids":["https://openalex.org/I43275575"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5047550068","display_name":"S\u00f8ren Dalsgaard","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I43275575","display_name":"Vestas (Denmark)","ror":"https://ror.org/003pdcw24","country_code":"DK","type":"company","lineage":["https://openalex.org/I43275575"]}],"countries":["DK"],"is_corresponding":false,"raw_author_name":"S\u00f8ren Dalsgaard","raw_affiliation_strings":["Vestas Wind Systems A/S, Denmark"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Vestas Wind Systems A/S, Denmark","institution_ids":["https://openalex.org/I43275575"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5058948281","display_name":"Anders Nyborg","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I43275575","display_name":"Vestas (Denmark)","ror":"https://ror.org/003pdcw24","country_code":"DK","type":"company","lineage":["https://openalex.org/I43275575"]}],"countries":["DK"],"is_corresponding":false,"raw_author_name":"Anders Nyborg","raw_affiliation_strings":["Vestas Wind Systems A/S, Denmark"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Vestas Wind Systems A/S, Denmark","institution_ids":["https://openalex.org/I43275575"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":7.2724,"has_fulltext":false,"cited_by_count":46,"citation_normalized_percentile":{"value":0.98141073,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":88,"max":99},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"8"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10740","display_name":"Wind Turbine Control Systems","score":0.9848999977111816,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10740","display_name":"Wind Turbine Control Systems","score":0.9848999977111816,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14444","display_name":"Power Systems and Renewable Energy","score":0.013399999588727951,"subfield":{"id":"https://openalex.org/subfields/2102","display_name":"Energy Engineering and Power Technology"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.0008999999845400453,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/wind-farms","display_name":"wind farms","score":0.996999979019165},{"id":"https://openalex.org/keywords/frequency-response","display_name":"frequency response","score":0.8679999709129333},{"id":"https://openalex.org/keywords/grid-support","display_name":"grid support","score":0.7269999980926514},{"id":"https://openalex.org/keywords/variable-speed-wind-turbine","display_name":"variable speed wind turbine","score":0.8119999766349792},{"id":"https://openalex.org/keywords/wind-speed-variability","display_name":"wind speed variation","score":0.7300000190734863},{"id":"https://openalex.org/keywords/grid-integration-of-wind-power","display_name":"grid integration of wind power","score":0.9350000023841858}],"concepts":[{"id":"https://openalex.org/C78600449","wikidata":"https://www.wikidata.org/wiki/Q43302","display_name":"Wind power","level":2,"score":0.8108359575271606},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.5542697310447693},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.5396192073822021},{"id":"https://openalex.org/C123153844","wikidata":"https://www.wikidata.org/wiki/Q360897","display_name":"Base load power plant","level":4,"score":0.4793032705783844},{"id":"https://openalex.org/C25915539","wikidata":"https://www.wikidata.org/wiki/Q220786","display_name":"Automatic frequency control","level":2,"score":0.46444183588027954},{"id":"https://openalex.org/C140311924","wikidata":"https://www.wikidata.org/wiki/Q200928","display_name":"Electric power transmission","level":2,"score":0.4259827435016632},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.4223603904247284},{"id":"https://openalex.org/C56685638","wikidata":"https://www.wikidata.org/wiki/Q2300474","display_name":"Power control","level":3,"score":0.41514891386032104},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.3979087173938751},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.39628469944000244},{"id":"https://openalex.org/C188573790","wikidata":"https://www.wikidata.org/wiki/Q12705","display_name":"Renewable energy","level":2,"score":0.38537535071372986},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.3762074410915375},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.34928345680236816},{"id":"https://openalex.org/C544738498","wikidata":"https://www.wikidata.org/wiki/Q861135","display_name":"Distributed generation","level":3,"score":0.29066067934036255},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/pes.2010.5589774","doi":"https://doi.org/10.1109/pes.2010.5589774","is_oa":false,"landing_page_url":"https://doi.org/10.1109/pes.2010.5589774","pdf_url":null,"source":{"id":"https://openalex.org/S4210212590","display_name":"IEEE Power Engineering Society General Meeting","issn_l":"1932-5517","issn":["1932-5517","2693-7891"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core"],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE PES General Meeting","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy","score":0.9090999960899353},{"id":"https://metadata.un.org/sdg/9","display_name":"Industry, innovation and infrastructure","score":0.8970999717712402},{"id":"https://metadata.un.org/sdg/13","display_name":"Climate action","score":0.46149998903274536}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":8,"referenced_works":["https://openalex.org/W1986086550","https://openalex.org/W1996797074","https://openalex.org/W2057377982","https://openalex.org/W2104652695","https://openalex.org/W2296241746","https://openalex.org/W2343886600","https://openalex.org/W2621631437","https://openalex.org/W3139890546"],"related_works":["https://openalex.org/W2121264465","https://openalex.org/W2012939503","https://openalex.org/W2758263901","https://openalex.org/W2037096025","https://openalex.org/W4294375604","https://openalex.org/W2765810981","https://openalex.org/W2181719584","https://openalex.org/W2062767063","https://openalex.org/W2596565137","https://openalex.org/W2380682602"],"abstract_inverted_index":{"Wind":[0],"speed":[1],"variability":[2],"generates":[3],"the":[4,19,24,70,77,88],"main":[5],"challenges":[6],"for":[7,56,69,105],"grid":[8,21,43,110],"integration":[9],"of":[10,80,90],"wind":[11,33,36,57,62,83,92],"power.":[12],"Worldwide,":[13],"requirements":[14],"governing":[15],"generator":[16],"connection":[17],"to":[18,29,41,49,95,109],"transmission":[20,71],"evolve":[22],"as":[23],"modern":[25,82,91],"energy":[26],"industry":[27],"continues":[28],"develop.":[30],"With":[31],"increased":[32],"power":[34,37,51,58,84,93],"penetration,":[35],"plants":[38,59,94],"are":[39,112],"required":[40],"provide":[42,65],"support":[44],"and":[45,99,107],"control":[46,54,67,78],"actions":[47],"similar":[48],"conventional":[50],"plants.":[52],"Dedicated":[53],"systems":[55],"employing":[60],"variable-speed":[61],"turbines":[63],"can":[64],"advanced":[66],"features":[68],"network":[72],"operator.":[73],"The":[74],"paper":[75],"summarizes":[76],"characteristics":[79],"a":[81],"plant.":[85],"It":[86],"identifies":[87],"capability":[89],"offer":[96],"fast":[97],"regulation":[98,106],"frequency":[100],"response":[101,108],"services.":[102],"Advanced":[103],"functionalities":[104],"disturbances":[111],"also":[113],"addressed.":[114]},"counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2024,"cited_by_count":2},{"year":2023,"cited_by_count":2},{"year":2021,"cited_by_count":6},{"year":2020,"cited_by_count":2},{"year":2018,"cited_by_count":1},{"year":2017,"cited_by_count":3},{"year":2016,"cited_by_count":2},{"year":2015,"cited_by_count":2},{"year":2014,"cited_by_count":8},{"year":2013,"cited_by_count":8},{"year":2012,"cited_by_count":6}],"updated_date":"2026-11-07T11:25:07.637180","created_date":"2016-06-24T00:00:00"}
