{"id":"https://openalex.org/W1980438850","doi":"https://doi.org/10.1109/upec.2006.367567","title":"Analysis of Air Gap Flux to Detect Induction Motor Faults","display_name":"Analysis of Air Gap Flux to Detect Induction Motor Faults","publication_year":2006,"publication_date":"2006-09-01","ids":{"openalex":"https://openalex.org/W1980438850","doi":"https://doi.org/10.1109/upec.2006.367567","mag":"1980438850"},"language":"en","primary_location":{"id":"doi:10.1109/upec.2006.367567","doi":"https://doi.org/10.1109/upec.2006.367567","is_oa":false,"landing_page_url":"https://doi.org/10.1109/upec.2006.367567","pdf_url":null,"source":{"id":"https://openalex.org/S4363608403","display_name":"International Universities Power Engineering Conference (UPEC)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the 41st International Universities Power Engineering Conference","raw_type":"proceedings-article"},"volume":null,"type":"conference-paper","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":null,"display_name":"Irahis Rodriguez","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I68740497","display_name":"Universidad de Carabobo","ror":"https://ror.org/05sj7yp62","country_code":"VE","type":"education","lineage":["https://openalex.org/I68740497"]}],"countries":["VE"],"is_corresponding":false,"raw_author_name":"Irahis Rodriguez","raw_affiliation_strings":["Facultad de Ingenieria Electrica, Universidad de Carabobo, Naguanagua Estado, Carabobo, Venezuela","Univ. de Carabobo"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Facultad de Ingenieria Electrica, Universidad de Carabobo, Naguanagua Estado, Carabobo, Venezuela","institution_ids":["https://openalex.org/I68740497"]},{"raw_affiliation_string":"Univ. de Carabobo","institution_ids":["https://openalex.org/I68740497"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5101819289","display_name":"Roberto Alves","orcid":"https://orcid.org/0000-0002-4320-7154","observed_orcids":["https://orcid.org/0000-0002-4320-7154"]},"institutions":[{"id":"https://openalex.org/I629287","display_name":"Universidad Sim\u00f3n Bol\u00edvar","ror":"https://ror.org/01ak5cj98","country_code":"VE","type":"education","lineage":["https://openalex.org/I629287"]}],"countries":["VE"],"is_corresponding":false,"raw_author_name":"Roberto Alves","raw_affiliation_strings":["Universidad Sim\u00f3n Bol\u00edvar, Venezuela"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Universidad Sim\u00f3n Bol\u00edvar, Venezuela","institution_ids":["https://openalex.org/I629287"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5001770010","display_name":"Victor Manuel Hern\u00e1ndez-Guzm\u00e1n","orcid":"https://orcid.org/0000-0002-7016-2561","observed_orcids":["https://orcid.org/0000-0002-7016-2561"]},"institutions":[{"id":"https://openalex.org/I629287","display_name":"Universidad Sim\u00f3n Bol\u00edvar","ror":"https://ror.org/01ak5cj98","country_code":"VE","type":"education","lineage":["https://openalex.org/I629287"]}],"countries":["VE"],"is_corresponding":false,"raw_author_name":"Victor Guzman","raw_affiliation_strings":["Universidad Sim\u00f3n Bol\u00edvar, Venezuela"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Universidad Sim\u00f3n Bol\u00edvar, Venezuela","institution_ids":["https://openalex.org/I629287"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.4309,"has_fulltext":false,"cited_by_count":18,"citation_normalized_percentile":{"value":0.51661797,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":88,"max":98},"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10220","display_name":"Machine Fault Diagnosis Techniques","score":0.9810000061988831,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10220","display_name":"Machine Fault Diagnosis Techniques","score":0.9810000061988831,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10278","display_name":"Electric Motor Design and Analysis","score":0.010999999940395355,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10504","display_name":"Sensorless Control of Electric Motors","score":0.00430000014603138,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/induction-motor-fault-detection","display_name":"induction motor fault detection","score":0.7519999742507935},{"id":"https://openalex.org/keywords/air-gap-flux","display_name":"air gap flux","score":0.902999997138977},{"id":"https://openalex.org/keywords/broken-rotor-bar-fault","display_name":"broken rotor bars","score":0.8370000123977661},{"id":"https://openalex.org/keywords/condition-monitoring","display_name":"condition monitoring","score":0.7329999804496765},{"id":"https://openalex.org/keywords/real-time-data-acquisition","display_name":"real-time data acquisition","score":0.6769999861717224},{"id":"https://openalex.org/keywords/labview","display_name":"LabVIEW","score":0.5830000042915344},{"id":"https://openalex.org/keywords/fault-indicators","display_name":"fault indicators","score":0.6970000267028809}],"concepts":[{"id":"https://openalex.org/C80962145","wikidata":"https://www.wikidata.org/wiki/Q207450","display_name":"Induction motor","level":3,"score":0.8723732829093933},{"id":"https://openalex.org/C2776529397","wikidata":"https://www.wikidata.org/wiki/Q190312","display_name":"Stator","level":2,"score":0.7724496722221375},{"id":"https://openalex.org/C17281054","wikidata":"https://www.wikidata.org/wiki/Q193466","display_name":"Rotor (electric)","level":2,"score":0.6609340310096741},{"id":"https://openalex.org/C50587689","wikidata":"https://www.wikidata.org/wiki/Q4698328","display_name":"Air gap (plumbing)","level":2,"score":0.5723897218704224},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.5506061911582947},{"id":"https://openalex.org/C2775846686","wikidata":"https://www.wikidata.org/wiki/Q643012","display_name":"Condition monitoring","level":2,"score":0.5267959237098694},{"id":"https://openalex.org/C152745839","wikidata":"https://www.wikidata.org/wiki/Q5438153","display_name":"Fault detection and isolation","level":3,"score":0.5242298245429993},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.509748637676239},{"id":"https://openalex.org/C188721877","wikidata":"https://www.wikidata.org/wiki/Q103510","display_name":"Bar (unit)","level":2,"score":0.45713600516319275},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.36439865827560425},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.3263735771179199},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.2128339409828186},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.1284904181957245},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.08847418427467346},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.08004727959632874},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.062416523694992065},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0},{"id":"https://openalex.org/C172707124","wikidata":"https://www.wikidata.org/wiki/Q423488","display_name":"Actuator","level":2,"score":0.0},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.0},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.0},{"id":"https://openalex.org/C153294291","wikidata":"https://www.wikidata.org/wiki/Q25261","display_name":"Meteorology","level":1,"score":0.0},{"id":"https://openalex.org/C159985019","wikidata":"https://www.wikidata.org/wiki/Q181790","display_name":"Composite material","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/upec.2006.367567","doi":"https://doi.org/10.1109/upec.2006.367567","is_oa":false,"landing_page_url":"https://doi.org/10.1109/upec.2006.367567","pdf_url":null,"source":{"id":"https://openalex.org/S4363608403","display_name":"International Universities Power Engineering Conference (UPEC)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the 41st International Universities Power Engineering Conference","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":9,"referenced_works":["https://openalex.org/W613155140","https://openalex.org/W1989616043","https://openalex.org/W2098626917","https://openalex.org/W2109725353","https://openalex.org/W2137014941","https://openalex.org/W2156091126","https://openalex.org/W2182835439","https://openalex.org/W2625440109","https://openalex.org/W4232447824"],"related_works":["https://openalex.org/W2550107599","https://openalex.org/W2331155930","https://openalex.org/W2139607034","https://openalex.org/W2056373822","https://openalex.org/W2805252169","https://openalex.org/W4409642373","https://openalex.org/W2552503686","https://openalex.org/W2030175268","https://openalex.org/W4285210209","https://openalex.org/W2122418036"],"abstract_inverted_index":{"This":[0],"paper":[1],"presents":[2],"the":[3,11,49,75,80,121],"application":[4],"of":[5,13],"motor":[6,44],"flux":[7,29,50],"signature":[8],"analysis":[9,30,65],"to":[10,38,60,99],"detection":[12],"stator":[14,96],"winding":[15,97],"failures,":[16],"broken":[17],"rotor":[18,88,91],"bars":[19],"and":[20,64,79,95,110,128],"end":[21,92],"ring":[22,93],"faults":[23,40],"in":[24,41,48,58,71,120],"induction":[25,43,77],"motors.":[26],"Air":[27],"gap":[28],"is":[31,66,69,136],"a":[32,55,129],"non-invasive,":[33],"on":[34],"line":[35],"monitoring":[36],"technique":[37],"diagnose":[39],"three-phase":[42],"drives,":[45],"detecting":[46],"differences":[47],"spectrum.":[51],"In":[52],"this":[53],"work":[54],"programme":[56],"developed":[57,138],"LabVIEW":[59],"perform":[61],"data":[62],"acquisition":[63],"presented.":[67],"Data":[68],"read":[70],"real":[72],"time":[73],"form":[74],"working":[76],"motor,":[78],"program":[81],"provides":[82],"three":[83,105],"fault":[84],"indicators":[85,106],"were":[86],"found:":[87],"bar":[89],"failure,":[90],"failure":[94,107],"turn":[98,100],"short":[101],"circuit.":[102],"With":[103],"these":[104],"location,":[108],"state":[109],"cause":[111],"can":[112],"be":[113],"determined.":[114],"The":[115],"system":[116],"has":[117],"being":[118,137],"validated":[119],"laboratory":[122],"with":[123,125],"motors":[124],"known":[126],"faults,":[127],"portable":[130],"version":[131],"for":[132],"industrial":[133],"workshop":[134],"tests":[135]},"counts_by_year":[{"year":2023,"cited_by_count":2},{"year":2022,"cited_by_count":1},{"year":2018,"cited_by_count":3},{"year":2017,"cited_by_count":1},{"year":2014,"cited_by_count":5},{"year":2013,"cited_by_count":2},{"year":2012,"cited_by_count":2}],"updated_date":"2026-10-30T12:39:25.321706","created_date":"2016-06-24T00:00:00"}
