{"id":"https://openalex.org/W1978960303","doi":"https://doi.org/10.1109/icpec.2013.6527656","title":"Travelling wave based fault location for teed circuits using unsynchronised measurements","display_name":"Travelling wave based fault location for teed circuits using unsynchronised measurements","publication_year":2013,"publication_date":"2013-02-01","ids":{"openalex":"https://openalex.org/W1978960303","doi":"https://doi.org/10.1109/icpec.2013.6527656","mag":"1978960303"},"language":"en","primary_location":{"id":"doi:10.1109/icpec.2013.6527656","doi":"https://doi.org/10.1109/icpec.2013.6527656","is_oa":false,"landing_page_url":"https://doi.org/10.1109/icpec.2013.6527656","pdf_url":null,"source":{"id":"https://openalex.org/S4306424047","display_name":"International Conference on Power, Energy and Control","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2013 International Conference on Power, Energy and Control (ICPEC)","raw_type":"proceedings-article"},"volume":null,"type":"conference-paper","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5038908785","display_name":"Kumarraja Andanapalli","orcid":"https://orcid.org/0000-0001-8643-4405","observed_orcids":["https://orcid.org/0000-0001-8643-4405"]},"institutions":[{"id":"https://openalex.org/I4400009046","display_name":"SRKR Engineering College","ror":"https://ror.org/038qac964","country_code":"IN","type":"education","lineage":["https://openalex.org/I4400009046"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"K. Andanapalli","raw_affiliation_strings":["Department of Electrical & Electronics Engineering, S.R.K.R. Engineering College, Bhimavaram, India","Dept. of Electr. & Electron. Eng., S.R.K.R. Eng. Coll., Bhimavaram, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical & Electronics Engineering, S.R.K.R. Engineering College, Bhimavaram, India","institution_ids":["https://openalex.org/I4400009046"]},{"raw_affiliation_string":"Dept. of Electr. & Electron. Eng., S.R.K.R. Eng. Coll., Bhimavaram, India","institution_ids":["https://openalex.org/I4400009046"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5110457360","display_name":"Bh. R. K. Varma","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4400009046","display_name":"SRKR Engineering College","ror":"https://ror.org/038qac964","country_code":"IN","type":"education","lineage":["https://openalex.org/I4400009046"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"B. R. K. Varma","raw_affiliation_strings":["Dept. of Electr. & Electron. Eng., S.R.K.R. Eng. Coll., Bhimavaram, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Dept. of Electr. & Electron. Eng., S.R.K.R. Eng. Coll., Bhimavaram, India","institution_ids":["https://openalex.org/I4400009046"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I4400009046"],"apc_list":null,"apc_paid":null,"fwci":0.4,"has_fulltext":false,"cited_by_count":13,"citation_normalized_percentile":{"value":0.42074042,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":88,"max":97},"biblio":{"volume":null,"issue":null,"first_page":"227","last_page":"232"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.9990000128746033,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.9990000128746033,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.0006000000284984708,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12737","display_name":"Electrical Fault Detection and Protection","score":9.999999747378752e-05,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/traveling-wave-fault-location","display_name":"traveling wave fault location","score":0.8360000252723694},{"id":"https://openalex.org/keywords/unsynchronized-measurements","display_name":"unsynchronized measurements","score":0.9509999752044678},{"id":"https://openalex.org/keywords/wavelet-transform","display_name":"wavelet transform","score":0.9129999876022339},{"id":"https://openalex.org/keywords/fault-transients","display_name":"fault transients","score":0.8330000042915344},{"id":"https://openalex.org/keywords/signal-synchronization","display_name":"signal synchronization","score":0.5580000281333923},{"id":"https://openalex.org/keywords/three-terminal-transmission-lines","display_name":"three-terminal transmission lines","score":0.7459999918937683},{"id":"https://openalex.org/keywords/power-system-protection","display_name":"power system protection","score":0.7910000085830688}],"concepts":[{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.7617950439453125},{"id":"https://openalex.org/C2778562939","wikidata":"https://www.wikidata.org/wiki/Q1298791","display_name":"Synchronization (alternating current)","level":3,"score":0.6320934295654297},{"id":"https://openalex.org/C196216189","wikidata":"https://www.wikidata.org/wiki/Q2867","display_name":"Wavelet transform","level":3,"score":0.5915939807891846},{"id":"https://openalex.org/C2780365114","wikidata":"https://www.wikidata.org/wiki/Q169478","display_name":"MATLAB","level":2,"score":0.5703446269035339},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5233144760131836},{"id":"https://openalex.org/C28719098","wikidata":"https://www.wikidata.org/wiki/Q44946","display_name":"Point (geometry)","level":2,"score":0.44372424483299255},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.41973692178726196},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.41169190406799316},{"id":"https://openalex.org/C11413529","wikidata":"https://www.wikidata.org/wiki/Q8366","display_name":"Algorithm","level":1,"score":0.38123127818107605},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.3781771659851074},{"id":"https://openalex.org/C47432892","wikidata":"https://www.wikidata.org/wiki/Q831390","display_name":"Wavelet","level":2,"score":0.3739680349826813},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.32033276557922363},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3084583282470703},{"id":"https://openalex.org/C127162648","wikidata":"https://www.wikidata.org/wiki/Q16858953","display_name":"Channel (broadcasting)","level":2,"score":0.16112345457077026},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.11777204275131226},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.10857674479484558},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.08365368843078613},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/icpec.2013.6527656","doi":"https://doi.org/10.1109/icpec.2013.6527656","is_oa":false,"landing_page_url":"https://doi.org/10.1109/icpec.2013.6527656","pdf_url":null,"source":{"id":"https://openalex.org/S4306424047","display_name":"International Conference on Power, Energy and Control","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2013 International Conference on Power, Energy and Control (ICPEC)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":11,"referenced_works":["https://openalex.org/W1965481914","https://openalex.org/W2017137360","https://openalex.org/W2024940752","https://openalex.org/W2028896432","https://openalex.org/W2089339315","https://openalex.org/W2110850909","https://openalex.org/W2149444871","https://openalex.org/W2154935517","https://openalex.org/W2157826977","https://openalex.org/W2167908884","https://openalex.org/W2547831517"],"related_works":["https://openalex.org/W2553105356","https://openalex.org/W2157826977","https://openalex.org/W4391495591","https://openalex.org/W2897067635","https://openalex.org/W2136753983","https://openalex.org/W2123057200","https://openalex.org/W2026463651","https://openalex.org/W2043065622","https://openalex.org/W2535675447","https://openalex.org/W2793363878"],"abstract_inverted_index":{"This":[0],"paper":[1],"presents":[2],"a":[3],"travelling":[4,75],"wave":[5],"based":[6,50],"fault":[7,24,42,60,101],"location":[8,61],"algorithm":[9,90,107],"for":[10,20,55,77,85,94],"teed":[11],"circuits":[12],"using":[13],"unsynchronized":[14],"measurements.":[15,79],"Wavelets":[16],"transform":[17],"is":[18,49,62,83,108],"used":[19],"analyzing":[21],"power":[22],"system":[23],"transients":[25,35],"in":[26,110],"order":[27],"to":[28],"capture":[29],"the":[30,34,37,41,71,95,106],"travel":[31],"time":[32,66],"of":[33,70,87,105],"along":[36],"monitored":[38],"lines":[39,98],"between":[40,68],"point":[43],"and":[44,73],"relays.":[45],"The":[46,59,89,103],"proposed":[47],"method":[48],"on":[51],"techniques":[52],"developed":[53],"earlier":[54],"two":[56],"terminal":[57,97],"lines.":[58],"determined":[63],"by":[64],"taking":[65],"difference":[67],"arrival":[69],"backward":[72],"forward":[74],"waves":[76],"synchronized":[78],"An":[80],"analytical":[81],"procedure":[82],"applied":[84],"synchronization":[86],"signals.":[88],"gives":[91],"accurate":[92],"results":[93],"three":[96],"under":[99],"different":[100],"conditions.":[102],"performance":[104],"tested":[109],"MATLAB":[111],"environment.":[112]},"counts_by_year":[{"year":2025,"cited_by_count":2},{"year":2024,"cited_by_count":1},{"year":2022,"cited_by_count":2},{"year":2021,"cited_by_count":2},{"year":2020,"cited_by_count":1},{"year":2018,"cited_by_count":1},{"year":2017,"cited_by_count":3},{"year":2015,"cited_by_count":1}],"updated_date":"2026-10-27T15:51:10.671819","created_date":"2016-06-24T00:00:00"}
