{"id":"https://openalex.org/W1978694672","doi":"https://doi.org/10.1115/imece2003-42172","title":"Thermal Performance Analysis of Fan-Heat Sinks for CPU Cooling","display_name":"Thermal Performance Analysis of Fan-Heat Sinks for CPU Cooling","publication_year":2003,"publication_date":"2003-01-01","ids":{"openalex":"https://openalex.org/W1978694672","doi":"https://doi.org/10.1115/imece2003-42172","mag":"1978694672"},"language":"en","primary_location":{"id":"doi:10.1115/imece2003-42172","doi":"https://doi.org/10.1115/imece2003-42172","is_oa":false,"landing_page_url":"https://doi.org/10.1115/imece2003-42172","pdf_url":null,"source":{"id":"https://openalex.org/S4363606942","display_name":"ASME International Mechanical Engineering Congress and Exposition (IMECE)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Heat Transfer, Volume 2","raw_type":"proceedings-article"},"volume":null,"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5100615887","display_name":"Seoyoung C. Kim","orcid":"https://orcid.org/0000-0002-2517-3579","observed_orcids":["https://orcid.org/0000-0002-2517-3579"]},"institutions":[{"id":"https://openalex.org/I4210140519","display_name":"Korean Association Of Science and Technology Studies","ror":"https://ror.org/04qh86j58","country_code":"KR","type":"other","lineage":["https://openalex.org/I4210140519"]},{"id":"https://openalex.org/I58716616","display_name":"Korea Institute of Science and Technology","ror":"https://ror.org/05kzfa883","country_code":"KR","type":"facility","lineage":["https://openalex.org/I27494661","https://openalex.org/I2801339556","https://openalex.org/I4210144908","https://openalex.org/I4387152098","https://openalex.org/I58716616"]}],"countries":["KR"],"is_corresponding":false,"raw_author_name":"Seo Young Kim","raw_affiliation_strings":["Korea Institute of Science and Technology, Seoul, Korea"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Korea Institute of Science and Technology, Seoul, Korea","institution_ids":["https://openalex.org/I4210140519","https://openalex.org/I58716616"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5058804592","display_name":"Ralph L. Webb","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I130769515","display_name":"Pennsylvania State University","ror":"https://ror.org/04p491231","country_code":"US","type":"education","lineage":["https://openalex.org/I130769515"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Ralph L. Webb","raw_affiliation_strings":["Pennsylvania State University, University Park, PA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Pennsylvania State University, University Park, PA","institution_ids":["https://openalex.org/I130769515"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":3,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":1.6751,"has_fulltext":false,"cited_by_count":12,"citation_normalized_percentile":{"value":0.82324132,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":95},"biblio":{"volume":null,"issue":null,"first_page":"235","last_page":"243"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10998","display_name":"Heat Transfer and Optimization","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10998","display_name":"Heat Transfer and Optimization","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11945","display_name":"Heat Transfer Mechanisms","score":0.00019999999494757503,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13116","display_name":"Heat Transfer and Numerical Methods","score":0.00019999999494757503,"subfield":{"id":"https://openalex.org/subfields/2206","display_name":"Computational Mechanics"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/cpu-cooling","display_name":"CPU cooling","score":0.9879999756813049},{"id":"https://openalex.org/keywords/plate-fin-heat-sink","display_name":"plate-fin heat sink","score":0.7850000262260437},{"id":"https://openalex.org/keywords/nusselt-number-correlation","display_name":"Nusselt number correlation","score":0.7940000295639038},{"id":"https://openalex.org/keywords/friction-factor","display_name":"friction factor","score":0.6869999766349792},{"id":"https://openalex.org/keywords/operating-point","display_name":"operating point","score":0.6119999885559082}],"concepts":[{"id":"https://openalex.org/C186937647","wikidata":"https://www.wikidata.org/wiki/Q1796959","display_name":"Heat sink","level":2,"score":0.8987947702407837},{"id":"https://openalex.org/C137693562","wikidata":"https://www.wikidata.org/wiki/Q899628","display_name":"Thermal resistance","level":3,"score":0.7755913734436035},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.6167852878570557},{"id":"https://openalex.org/C57879066","wikidata":"https://www.wikidata.org/wiki/Q41217","display_name":"Mechanics","level":1,"score":0.6162378191947937},{"id":"https://openalex.org/C91721477","wikidata":"https://www.wikidata.org/wiki/Q778612","display_name":"Fin","level":2,"score":0.5857076048851013},{"id":"https://openalex.org/C50517652","wikidata":"https://www.wikidata.org/wiki/Q179635","display_name":"Heat transfer","level":2,"score":0.4985816478729248},{"id":"https://openalex.org/C29700514","wikidata":"https://www.wikidata.org/wiki/Q634340","display_name":"Heat transfer coefficient","level":3,"score":0.42941373586654663},{"id":"https://openalex.org/C130230704","wikidata":"https://www.wikidata.org/wiki/Q898280","display_name":"Nusselt number","level":4,"score":0.42125511169433594},{"id":"https://openalex.org/C48632124","wikidata":"https://www.wikidata.org/wiki/Q617088","display_name":"Heat spreader","level":3,"score":0.4113450050354004},{"id":"https://openalex.org/C97355855","wikidata":"https://www.wikidata.org/wiki/Q11473","display_name":"Thermodynamics","level":1,"score":0.3551722764968872},{"id":"https://openalex.org/C159985019","wikidata":"https://www.wikidata.org/wiki/Q181790","display_name":"Composite material","level":1,"score":0.2456241250038147},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.13727307319641113},{"id":"https://openalex.org/C182748727","wikidata":"https://www.wikidata.org/wiki/Q178932","display_name":"Reynolds number","level":3,"score":0.0},{"id":"https://openalex.org/C196558001","wikidata":"https://www.wikidata.org/wiki/Q190132","display_name":"Turbulence","level":2,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1115/imece2003-42172","doi":"https://doi.org/10.1115/imece2003-42172","is_oa":false,"landing_page_url":"https://doi.org/10.1115/imece2003-42172","pdf_url":null,"source":{"id":"https://openalex.org/S4363606942","display_name":"ASME International Mechanical Engineering Congress and Exposition (IMECE)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Heat Transfer, Volume 2","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"study_designs":[],"awards":[],"funders":[{"id":"https://openalex.org/F4320322348","display_name":"Korea Science and Engineering Foundation","ror":"https://ror.org/013aysd81"}],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W2122324070","https://openalex.org/W1593601441","https://openalex.org/W2000987199","https://openalex.org/W1983912335","https://openalex.org/W2139127579","https://openalex.org/W4238413993","https://openalex.org/W2324321333","https://openalex.org/W4386426866","https://openalex.org/W4403634745","https://openalex.org/W2093800544"],"abstract_inverted_index":{"The":[0,68,98,118,184],"thermal":[1,62,145,175,195,209],"performance":[2,46,135,210],"of":[3,24,108,127,147],"plate":[4,57],"fin,":[5],"round":[6,167],"pin-fin":[7,168],"and":[8,105,132],"offset":[9,186,204],"strip-fin":[10,187],"heat":[11,54,86,96,109,148,160,169,182,188,200],"sinks":[12,23,149,170],"with":[13,34],"a":[14,35,85,191],"duct-flow":[15],"type":[16],"fan":[17,38,73,134],"arrangement":[18],"was":[19],"analytically":[20],"evaluated.":[21],"Heat":[22],"65mm":[25],"\u00d7":[26,30,40],"60mm":[27],"plan":[28],"area":[29],"50":[31],"mm":[32,52],"height":[33],"4300-RPM":[36],"DC":[37],"(60mm":[39],"15mm)":[41],"were":[42],"chosen":[43,95,159],"for":[44,93,157],"the":[45,72,78,89,94,103,106,114,124,128,133,139,143,153,158,198,203],"comparison.":[47],"A":[48],"constant":[49],"temperature,":[50],"6":[51],"thick":[53],"sink":[55,87,110,189],"base":[56],"is":[58,65,75,121,150],"assumed":[59],"so":[60],"that":[61,165],"spreading":[63],"resistance":[64,146,176,196],"not":[66],"involved.":[67],"operating":[69,119,140],"point":[70,120,126],"on":[71,77],"curve":[74,83,131],"based":[76],"flow":[79,115,129],"pressure":[80],"drop":[81],"impedance":[82,116,130],"through":[84],"using":[88],"friction":[90],"factor":[91],"correlation":[92,156],"sink.":[97,161,183,201],"loss":[99],"coefficients":[100],"at":[101],"both":[102],"entrance":[104],"exit":[107],"are":[111],"included":[112],"in":[113],"curve.":[117,136],"defined":[122],"by":[123],"balance":[125],"After":[137],"determining":[138],"air":[141],"velocity,":[142],"convective":[144,174,194],"evaluated":[151],"from":[152],"Nusselt":[154],"number":[155],"Results":[162],"obtained":[163],"show":[164],"optimized":[166,180,185],"provide":[171],"32.8%-to-46.4%":[172],"higher":[173],"compared":[177],"to":[178],"an":[179],"plate-fin":[181,199],"shows":[190],"slightly":[192],"lower":[193],"than":[197],"As":[202],"strip":[205],"length":[206],"decreases,":[207],"however,":[208],"seriously":[211],"deteriorates.":[212]},"counts_by_year":[{"year":2023,"cited_by_count":1},{"year":2020,"cited_by_count":2},{"year":2015,"cited_by_count":1}],"updated_date":"2026-11-01T11:40:01.658920","created_date":"2016-06-24T00:00:00"}
