{"id":"https://openalex.org/W1978560972","doi":"https://doi.org/10.1049/piee.1970.0259","title":"Discharge detection in high-voltage power transformers","display_name":"Discharge detection in high-voltage power transformers","alternate_titles":[],"publication_year":1970,"publication_date":"1970-01-01","ids":{"openalex":"https://openalex.org/W1978560972","doi":"https://doi.org/10.1049/piee.1970.0259","mag":"1978560972"},"language":"en","primary_location":{"id":"doi:10.1049/piee.1970.0259","doi":"https://doi.org/10.1049/piee.1970.0259","is_oa":false,"landing_page_url":"https://doi.org/10.1049/piee.1970.0259","pdf_url":null,"source":{"id":"https://openalex.org/S4210235475","display_name":"Proceedings of the Institution of Electrical Engineers","issn_l":"0020-3270","issn":["0020-3270","2053-7891"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/P4320800662","host_organization_name":"Institution of Electrical Engineers","host_organization_lineage":["https://openalex.org/P4320800662"],"host_organization_lineage_names":["Institution of Electrical Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the Institution of Electrical Engineers","raw_type":"journal-article"},"parent_works":[],"lineage":["https://openalex.org/W1978560972"],"child_works_count":0,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5113546688","display_name":"R.E. James","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":true,"contributor_roles":[],"raw_author_name":"R.E. James","raw_affiliation_strings":["Department of Electrical & Electronic Engineering, Portsmouth Polytechnic, Portsmouth, UK","Portsmouth Polytechnic, Department of Electrical & Electronic Engineering, Portsmouth, UK"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical & Electronic Engineering, Portsmouth Polytechnic, Portsmouth, UK","institution_ids":[]},{"raw_affiliation_string":"Portsmouth Polytechnic, Department of Electrical & Electronic Engineering, Portsmouth, UK","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":["https://openalex.org/A5113546688"],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":1.2101,"has_fulltext":false,"cited_by_count":32,"reviewed_by_count":0,"citation_normalized_percentile":{"value":0.75408788,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":86,"max":95},"biblio":{"volume":"117","issue":"7","first_page":"1352","last_page":"1352"},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11343","display_name":"Power Transformer Diagnostics and Insulation","score":0.6699000000953674,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11343","display_name":"Power Transformer Diagnostics and Insulation","score":0.6699000000953674,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10511","display_name":"High voltage insulation and dielectric phenomena","score":0.32710000872612,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12737","display_name":"Electrical Fault Detection and Protection","score":0.00039999998989515007,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/discharge-detection","display_name":"discharge detection","score":0.8550000190734863},{"id":"https://openalex.org/keywords/high-voltage-power-transformers","display_name":"high-voltage power transformers","score":0.9380000233650208},{"id":"https://openalex.org/keywords/partial-discharge","display_name":"partial discharge","score":0.6620000004768372},{"id":"https://openalex.org/keywords/discharge-disposition","display_name":"discharge disposition","score":0.6200000047683716},{"id":"https://openalex.org/keywords/ultrasonic-detection","display_name":"ultrasonic detection","score":0.800000011920929},{"id":"https://openalex.org/keywords/high-voltage-insulation-testing","display_name":"high-voltage insulation testing","score":0.8629999756813049},{"id":"https://openalex.org/keywords/acceptance-levels","display_name":"acceptance levels","score":0.7170000076293945}],"concepts":[{"id":"https://openalex.org/C66322947","wikidata":"https://www.wikidata.org/wiki/Q11658","display_name":"Transformer","level":3,"score":0.7279963493347168},{"id":"https://openalex.org/C130143024","wikidata":"https://www.wikidata.org/wiki/Q1929972","display_name":"Partial discharge","level":3,"score":0.5754009485244751},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.5427127480506897},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.49939417839050293},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.47420433163642883},{"id":"https://openalex.org/C88182573","wikidata":"https://www.wikidata.org/wiki/Q1139740","display_name":"High voltage","level":3,"score":0.44867584109306335},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.4444701075553894},{"id":"https://openalex.org/C133770746","wikidata":"https://www.wikidata.org/wiki/Q856535","display_name":"Current transformer","level":4,"score":0.4102384150028229},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.29746556282043457}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1049/piee.1970.0259","doi":"https://doi.org/10.1049/piee.1970.0259","is_oa":false,"landing_page_url":"https://doi.org/10.1049/piee.1970.0259","pdf_url":null,"source":{"id":"https://openalex.org/S4210235475","display_name":"Proceedings of the Institution of Electrical Engineers","issn_l":"0020-3270","issn":["0020-3270","2053-7891"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/P4320800662","host_organization_name":"Institution of Electrical Engineers","host_organization_lineage":["https://openalex.org/P4320800662"],"host_organization_lineage_names":["Institution of Electrical Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the Institution of Electrical Engineers","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.5378999710083008,"display_name":"Industry, innovation and infrastructure","id":"https://metadata.un.org/sdg/9"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":16,"referenced_works":["https://openalex.org/W640558928","https://openalex.org/W1495427021","https://openalex.org/W1969849072","https://openalex.org/W1984245068","https://openalex.org/W1993218601","https://openalex.org/W2000840794","https://openalex.org/W2007885404","https://openalex.org/W2020759947","https://openalex.org/W2070138689","https://openalex.org/W2072538698","https://openalex.org/W2080504201","https://openalex.org/W2100207323","https://openalex.org/W2160819068","https://openalex.org/W2169191337","https://openalex.org/W2495325581","https://openalex.org/W6629081678"],"related_works":["https://openalex.org/W2042763665","https://openalex.org/W2116510919","https://openalex.org/W4236143246","https://openalex.org/W2117638872","https://openalex.org/W2494357251","https://openalex.org/W7131127112","https://openalex.org/W2074670937","https://openalex.org/W1607589457","https://openalex.org/W2582094723","https://openalex.org/W206337397"],"abstract_inverted_index":{"The":[0],"paper":[1,131],"presents":[2],"the":[3,8,23,33,58,100,130,139,150,153,162,168],"special":[4],"problems":[5,141],"involved":[6,142],"in":[7,29,119,143],"detection":[9],"of":[10,22,32,74,102,138,152],"discharges":[11],"within":[12],"high-voltage":[13,65],"power":[14],"transformers.":[15,109],"This":[16],"is":[17,43,49,69,81,94,97,127],"followed":[18],"by":[19],"a":[20,46,91,113,122,135],"review":[21],"various":[24],"location":[25,123],"techniques":[26],"being":[27],"developed":[28,160],"different":[30],"parts":[31],"world.":[34],"Both":[35],"electrical":[36],"and":[37,64,146,155],"ultrasonic":[38],"methods":[39],"are":[40,55],"considered.":[41],"It":[42,68],"concluded":[44],"that":[45,71,112,129],"routine":[47],"test":[48,92],"not":[50],"yet":[51],"possible,":[52],"but":[53],"suggestions":[54],"made":[56,98],"regarding":[57],"relationship":[59],"between":[60],"any":[61],"such":[62],"measurement":[63],"insulation":[66],"tests.":[67],"emphasised":[70],"further":[72],"information":[73],"discharge":[75],"values":[76],"obtained":[77],"under":[78],"prescribed":[79],"conditions":[80],"essential":[82],"before":[83],"acceptance":[84],"levels":[85],"can":[86],"be":[87,116],"seriously":[88],"discussed.":[89],"Again,":[90],"procedure":[93],"suggested.":[95],"Comment":[96],"on":[99,108,167],"suitability":[101],"existing":[103],"discharge-detection":[104],"equipment":[105],"for":[106],"measurements":[107],"Evidence":[110],"indicates":[111],"change":[114],"might":[115],"desirable,":[117],"possibly":[118],"association":[120],"with":[121],"technique.":[124],"Finally,":[125],"it":[126],"hoped":[128],"will":[132],"help":[133],"produce":[134],"fuller":[136],"discussion":[137],"real":[140],"transformer-discharge":[144],"detection,":[145],"perhaps":[147],"lead":[148],"to":[149],"crystallising":[151],"many":[154],"varied":[156],"ideas":[157],"which":[158],"have":[159],"since":[161],"previous":[163],"UK":[164],"joint":[165],"publication":[166],"subject.":[169]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W1978560972","counts_by_year":[{"year":2021,"cited_by_count":1},{"year":2020,"cited_by_count":1},{"year":2019,"cited_by_count":1},{"year":2018,"cited_by_count":2},{"year":2017,"cited_by_count":2},{"year":2016,"cited_by_count":2},{"year":2015,"cited_by_count":1},{"year":2014,"cited_by_count":1},{"year":2013,"cited_by_count":2}],"updated_date":"2026-11-16T12:05:36.265796","created_date":"2016-06-24T00:00:00"}
