{"id":"https://openalex.org/W1974036673","doi":"https://doi.org/10.1088/0026-1394/33/4/7","title":"1000 h stability test of the Au/Pd thermocouple at 1000 C","display_name":"1000 h stability test of the Au/Pd thermocouple at 1000 C","publication_year":1996,"publication_date":"1996-08-01","ids":{"openalex":"https://openalex.org/W1974036673","doi":"https://doi.org/10.1088/0026-1394/33/4/7","mag":"1974036673"},"language":"en","primary_location":{"id":"doi:10.1088/0026-1394/33/4/7","doi":"https://doi.org/10.1088/0026-1394/33/4/7","is_oa":true,"landing_page_url":"https://doi.org/10.1088/0026-1394/33/4/7","pdf_url":"https://iopscience.iop.org/article/10.1088/0026-1394/33/4/7/pdf","source":{"id":"https://openalex.org/S7291761","display_name":"Metrologia","issn_l":"0026-1394","issn":["0026-1394","1681-7575"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["anvur-scientific","cwts-core","dongbi-b","jufo-2","norway-1","poland-70","russia-white-list-2"],"host_organization":"https://openalex.org/P4310320083","host_organization_name":"IOP Publishing","host_organization_lineage":["https://openalex.org/P4310320083","https://openalex.org/P4310311669"],"host_organization_lineage_names":["IOP Publishing","Institute of Physics"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Metrologia","raw_type":"journal-article"},"volume":null,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"bronze","oa_url":"https://iopscience.iop.org/article/10.1088/0026-1394/33/4/7/pdf","any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5044272699","display_name":"Y-G Kim","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I2799611809","display_name":"Korea Research Institute of Standards and Science","ror":"https://ror.org/01az7b475","country_code":"KR","type":"facility","lineage":["https://openalex.org/I2799611809","https://openalex.org/I2801339556","https://openalex.org/I4210144908","https://openalex.org/I4387152098"]}],"countries":["KR"],"is_corresponding":false,"raw_author_name":"Y-G Kim","raw_affiliation_strings":["KRISS"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"KRISS","institution_ids":["https://openalex.org/I2799611809"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5111515554","display_name":"Kee-Sool Gam","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I2799611809","display_name":"Korea Research Institute of Standards and Science","ror":"https://ror.org/01az7b475","country_code":"KR","type":"facility","lineage":["https://openalex.org/I2799611809","https://openalex.org/I2801339556","https://openalex.org/I4210144908","https://openalex.org/I4387152098"]}],"countries":["KR"],"is_corresponding":false,"raw_author_name":"K S Gam","raw_affiliation_strings":["KRISS"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"KRISS","institution_ids":["https://openalex.org/I2799611809"]}]},{"author_position":"last","author":{"id":null,"display_name":"C Rhee","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I2799611809","display_name":"Korea Research Institute of Standards and Science","ror":"https://ror.org/01az7b475","country_code":"KR","type":"facility","lineage":["https://openalex.org/I2799611809","https://openalex.org/I2801339556","https://openalex.org/I4210144908","https://openalex.org/I4387152098"]}],"countries":["KR"],"is_corresponding":false,"raw_author_name":"C Rhee","raw_affiliation_strings":["KRISS"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"KRISS","institution_ids":["https://openalex.org/I2799611809"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I2799611809"],"apc_list":{"value":3325,"currency":"USD","value_usd":3325},"apc_paid":null,"fwci":4.2897,"has_fulltext":true,"cited_by_count":9,"citation_normalized_percentile":{"value":0.93306601,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":87,"max":92},"biblio":{"volume":"33","issue":"4","first_page":"337","last_page":"339"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T13928","display_name":"Advanced Sensor Technologies Research","score":0.9940999746322632,"subfield":{"id":"https://openalex.org/subfields/3105","display_name":"Instrumentation"},"field":{"id":"https://openalex.org/fields/31","display_name":"Physics and Astronomy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T13928","display_name":"Advanced Sensor Technologies Research","score":0.9940999746322632,"subfield":{"id":"https://openalex.org/subfields/3105","display_name":"Instrumentation"},"field":{"id":"https://openalex.org/fields/31","display_name":"Physics and Astronomy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12019","display_name":"Calibration and Measurement Techniques","score":0.0052999998442828655,"subfield":{"id":"https://openalex.org/subfields/2202","display_name":"Aerospace Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11890","display_name":"Scientific Measurement and Uncertainty Evaluation","score":9.999999747378752e-05,"subfield":{"id":"https://openalex.org/subfields/3105","display_name":"Instrumentation"},"field":{"id":"https://openalex.org/fields/31","display_name":"Physics and Astronomy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/high-temperature-thermocouples","display_name":"high-temperature thermocouples","score":0.8700000047683716},{"id":"https://openalex.org/keywords/long-term-stability-testing","display_name":"long-term stability testing","score":0.640999972820282},{"id":"https://openalex.org/keywords/emf-measurements","display_name":"emf measurements","score":0.5659999847412109},{"id":"https://openalex.org/keywords/reproducibility","display_name":"reproducibility","score":0.9129999876022339}],"concepts":[{"id":"https://openalex.org/C168068576","wikidata":"https://www.wikidata.org/wiki/Q190241","display_name":"Thermocouple","level":2,"score":0.9845544099807739},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.7075241208076477},{"id":"https://openalex.org/C9893847","wikidata":"https://www.wikidata.org/wiki/Q1425625","display_name":"Reproducibility","level":2,"score":0.6459318995475769},{"id":"https://openalex.org/C2777155165","wikidata":"https://www.wikidata.org/wiki/Q646","display_name":"Thermometer","level":2,"score":0.5750019550323486},{"id":"https://openalex.org/C72293138","wikidata":"https://www.wikidata.org/wiki/Q909741","display_name":"Temperature measurement","level":2,"score":0.41235843300819397},{"id":"https://openalex.org/C113196181","wikidata":"https://www.wikidata.org/wiki/Q485223","display_name":"Analytical Chemistry (journal)","level":2,"score":0.35970234870910645},{"id":"https://openalex.org/C159985019","wikidata":"https://www.wikidata.org/wiki/Q181790","display_name":"Composite material","level":1,"score":0.31279540061950684},{"id":"https://openalex.org/C97355855","wikidata":"https://www.wikidata.org/wiki/Q11473","display_name":"Thermodynamics","level":1,"score":0.23127985000610352},{"id":"https://openalex.org/C185592680","wikidata":"https://www.wikidata.org/wiki/Q2329","display_name":"Chemistry","level":0,"score":0.15618163347244263},{"id":"https://openalex.org/C43617362","wikidata":"https://www.wikidata.org/wiki/Q170050","display_name":"Chromatography","level":1,"score":0.07909494638442993},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.05331224203109741}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1088/0026-1394/33/4/7","doi":"https://doi.org/10.1088/0026-1394/33/4/7","is_oa":true,"landing_page_url":"https://doi.org/10.1088/0026-1394/33/4/7","pdf_url":"https://iopscience.iop.org/article/10.1088/0026-1394/33/4/7/pdf","source":{"id":"https://openalex.org/S7291761","display_name":"Metrologia","issn_l":"0026-1394","issn":["0026-1394","1681-7575"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["anvur-scientific","cwts-core","dongbi-b","jufo-2","norway-1","poland-70","russia-white-list-2"],"host_organization":"https://openalex.org/P4310320083","host_organization_name":"IOP Publishing","host_organization_lineage":["https://openalex.org/P4310320083","https://openalex.org/P4310311669"],"host_organization_lineage_names":["IOP Publishing","Institute of Physics"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Metrologia","raw_type":"journal-article"}],"best_oa_location":{"id":"doi:10.1088/0026-1394/33/4/7","doi":"https://doi.org/10.1088/0026-1394/33/4/7","is_oa":true,"landing_page_url":"https://doi.org/10.1088/0026-1394/33/4/7","pdf_url":"https://iopscience.iop.org/article/10.1088/0026-1394/33/4/7/pdf","source":{"id":"https://openalex.org/S7291761","display_name":"Metrologia","issn_l":"0026-1394","issn":["0026-1394","1681-7575"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["anvur-scientific","cwts-core","dongbi-b","jufo-2","norway-1","poland-70","russia-white-list-2"],"host_organization":"https://openalex.org/P4310320083","host_organization_name":"IOP Publishing","host_organization_lineage":["https://openalex.org/P4310320083","https://openalex.org/P4310311669"],"host_organization_lineage_names":["IOP Publishing","Institute of Physics"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Metrologia","raw_type":"journal-article"},"sustainable_development_goals":[],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":true,"pdf":true},"content_urls":{"pdf":"https://content.openalex.org/works/W1974036673.pdf","grobid_xml":"https://content.openalex.org/works/W1974036673.grobid-xml"},"referenced_works_count":5,"referenced_works":["https://openalex.org/W1513028201","https://openalex.org/W1990544030","https://openalex.org/W2013084695","https://openalex.org/W2064998769","https://openalex.org/W2081646566"],"related_works":["https://openalex.org/W2064998769","https://openalex.org/W2076770714","https://openalex.org/W1625219540","https://openalex.org/W1999332753","https://openalex.org/W1990544030","https://openalex.org/W3194178603","https://openalex.org/W1991966552","https://openalex.org/W1565262114","https://openalex.org/W1977625555","https://openalex.org/W2066083775"],"abstract_inverted_index":{"A":[0,14],"newly":[1],"developed":[2],"Au/Pd":[3,19,74,90],"thermocouple":[4,20,75,91],"has":[5,21],"shown":[6],"very":[7],"high":[8],"reproducibility":[9],"and":[10,46,58],"good":[11],"immersion":[12],"characteristics.":[13],"stability":[15,71],"test":[16,83],"of":[17,72],"the":[18,60,69,73,82,89],"been":[22],"conducted":[23],"for":[24,36,99],"1000":[25,28,63],"h":[26],"at":[27,62],"\u00b0C":[29],"in":[30,52,106],"air":[31],"to":[32],"assess":[33],"its":[34],"suitability":[35],"practical":[37],"application.":[38],"Two":[39],"thermocouples":[40],"from":[41],"two":[42],"manufacturers":[43],"were":[44,50],"fabricated":[45],"their":[47],"emf":[48],"values":[49],"checked":[51],"a":[53,102],"silver":[54],"freezing-point":[55],"cell":[56],"before":[57],"after":[59],"soaking":[61],"\u00b0C.":[64],"It":[65],"was":[66],"found":[67],"that":[68,88],"high-temperature":[70,104],"is":[76],"within":[77],"\u00b130":[78],"mK":[79],"(2\u03c3)":[80],"throughout":[81],"time.":[84],"This":[85],"result":[86],"implies":[87],"possesses":[92],"characteristics":[93],"which":[94],"may":[95],"make":[96],"it":[97],"suitable":[98],"use":[100],"as":[101],"secondary":[103],"thermometer":[105],"industry.":[107]},"counts_by_year":[{"year":2021,"cited_by_count":1}],"updated_date":"2026-09-29T14:09:16.559479","created_date":"2016-06-24T00:00:00"}