{"id":"https://openalex.org/W1970900775","doi":"https://doi.org/10.1109/tie.2015.2399273","title":"Effective Test Bed of 380-V DC Distribution System Using Isolated Power Converters","display_name":"Effective Test Bed of 380-V DC Distribution System Using Isolated Power Converters","alternate_titles":[],"publication_year":2015,"publication_date":"2015-02-04","ids":{"openalex":"https://openalex.org/W1970900775","doi":"https://doi.org/10.1109/tie.2015.2399273","mag":"1970900775"},"language":"en","primary_location":{"id":"doi:10.1109/tie.2015.2399273","doi":"https://doi.org/10.1109/tie.2015.2399273","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tie.2015.2399273","pdf_url":null,"source":{"id":"https://openalex.org/S58031724","display_name":"IEEE Transactions on Industrial Electronics","issn_l":"0278-0046","issn":["0278-0046","1557-9948"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-a","jufo-3","ki-jl-1","norway-2","poland-200","russia-white-list-1","vabb-shw"],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Industrial Electronics","raw_type":"journal-article"},"parent_works":[],"lineage":["https://openalex.org/W1970900775"],"child_works_count":0,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5110173522","display_name":"Myung-Hyo Ryu","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I196471810","display_name":"Korea Electrotechnology Research Institute","ror":"https://ror.org/03ctacd45","country_code":"KR","type":"nonprofit","lineage":["https://openalex.org/I196471810"]}],"countries":["KR"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"Myung-Hyo Ryu","raw_affiliation_strings":["Power Conversion and Control Research Center, HVDC Research Division, Korea Electrotechnology Research Institute (KERI), Changwon, Korea","Power Conversion & Control Res. Center, Korea Electrotechnol. Res. Inst., Changwon, South Korea"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Power Conversion and Control Research Center, HVDC Research Division, Korea Electrotechnology Research Institute (KERI), Changwon, Korea","institution_ids":["https://openalex.org/I196471810"]},{"raw_affiliation_string":"Power Conversion & Control Res. Center, Korea Electrotechnol. Res. Inst., Changwon, South Korea","institution_ids":["https://openalex.org/I196471810"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5101519657","display_name":"Ho-Sung Kim","orcid":"https://orcid.org/0000-0002-6112-1637","observed_orcids":["https://orcid.org/0000-0002-6112-1637"]},"institutions":[{"id":"https://openalex.org/I196471810","display_name":"Korea Electrotechnology Research Institute","ror":"https://ror.org/03ctacd45","country_code":"KR","type":"nonprofit","lineage":["https://openalex.org/I196471810"]}],"countries":["KR"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"Ho-Sung Kim","raw_affiliation_strings":["Power Conversion and Control Research Center, HVDC Research Division, Korea Electrotechnology Research Institute (KERI), Changwon, Korea","Power Conversion & Control Res. Center, Korea Electrotechnol. Res. Inst., Changwon, South Korea"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Power Conversion and Control Research Center, HVDC Research Division, Korea Electrotechnology Research Institute (KERI), Changwon, Korea","institution_ids":["https://openalex.org/I196471810"]},{"raw_affiliation_string":"Power Conversion & Control Res. Center, Korea Electrotechnol. Res. Inst., Changwon, South Korea","institution_ids":["https://openalex.org/I196471810"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5091276815","display_name":"Ju-Won Baek","orcid":"https://orcid.org/0000-0002-4459-6534","observed_orcids":["https://orcid.org/0000-0002-4459-6534"]},"institutions":[{"id":"https://openalex.org/I196471810","display_name":"Korea Electrotechnology Research Institute","ror":"https://ror.org/03ctacd45","country_code":"KR","type":"nonprofit","lineage":["https://openalex.org/I196471810"]}],"countries":["KR"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"Ju-Won Baek","raw_affiliation_strings":["Power Conversion and Control Research Center, HVDC Research Division, Korea Electrotechnology Research Institute (KERI), Changwon, Korea","Power Conversion & Control Res. Center, Korea Electrotechnol. Res. Inst., Changwon, South Korea"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Power Conversion and Control Research Center, HVDC Research Division, Korea Electrotechnology Research Institute (KERI), Changwon, Korea","institution_ids":["https://openalex.org/I196471810"]},{"raw_affiliation_string":"Power Conversion & Control Res. Center, Korea Electrotechnol. Res. Inst., Changwon, South Korea","institution_ids":["https://openalex.org/I196471810"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5051961613","display_name":"Heung-Geun Kim","orcid":"https://orcid.org/0000-0002-5708-9945","observed_orcids":["https://orcid.org/0000-0002-5708-9945"]},"institutions":[{"id":"https://openalex.org/I31419693","display_name":"Kyungpook National University","ror":"https://ror.org/040c17130","country_code":"KR","type":"education","lineage":["https://openalex.org/I31419693"]}],"countries":["KR"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"Heung-Geun Kim","raw_affiliation_strings":["Department of Electrical Engineering, Kyungpook National University (KNU), Daegu, Korea","Dept. of Electr. Eng., Kyungpook Nat. Univ., Daegu, South Korea"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, Kyungpook National University (KNU), Daegu, Korea","institution_ids":["https://openalex.org/I31419693"]},{"raw_affiliation_string":"Dept. of Electr. Eng., Kyungpook Nat. Univ., Daegu, South Korea","institution_ids":["https://openalex.org/I31419693"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5034107583","display_name":"Jee\u2010Hoon Jung","orcid":"https://orcid.org/0000-0002-4055-3764","observed_orcids":["https://orcid.org/0000-0002-4055-3764"]},"institutions":[{"id":"https://openalex.org/I48566637","display_name":"Ulsan National Institute of Science and Technology","ror":"https://ror.org/017cjz748","country_code":"KR","type":"education","lineage":["https://openalex.org/I48566637"]}],"countries":["KR"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"Jee-Hoon Jung","raw_affiliation_strings":["School of Electrical and Computer Engineering, Ulsan National Institute of Science and Technology (UNIST), Ulsan, Korea","Sch. of Electr. & Comput. Eng., Ulsan Nat. Inst. of Sci. & Technol., Ulsan, South Korea#TAB#"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"School of Electrical and Computer Engineering, Ulsan National Institute of Science and Technology (UNIST), Ulsan, Korea","institution_ids":["https://openalex.org/I48566637"]},{"raw_affiliation_string":"Sch. of Electr. & Comput. Eng., Ulsan Nat. Inst. of Sci. & Technol., Ulsan, South Korea#TAB#","institution_ids":["https://openalex.org/I48566637"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":{"value":2645,"currency":"USD","value_usd":2645},"apc_paid":null,"fwci":6.4262,"has_fulltext":false,"cited_by_count":166,"reviewed_by_count":0,"citation_normalized_percentile":{"value":0.9724323,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":96,"max":100},"biblio":{"volume":"62","issue":"7","first_page":"4525","last_page":"4536"},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":0.9829000234603882,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":0.9829000234603882,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":0.00419999985024333,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12810","display_name":"Real-time simulation and control systems","score":0.004100000020116568,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/isolated-power-converter","display_name":"isolated converter","score":0.8479999899864197},{"id":"https://openalex.org/keywords/testbed","display_name":"testbed","score":0.8309999704360962},{"id":"https://openalex.org/keywords/bidirectional-ac-dc-converter","display_name":"bidirectional AC-DC converter","score":0.8080000281333923},{"id":"https://openalex.org/keywords/bidirectional-dc-dc-converter","display_name":"bidirectional DC-DC converter","score":0.9860000014305115},{"id":"https://openalex.org/keywords/dual-active-bridge-converter","display_name":"dual active bridge converter","score":0.972000002861023},{"id":"https://openalex.org/keywords/cllc-resonant-converter","display_name":"CLLC resonant converter","score":0.9259999990463257},{"id":"https://openalex.org/keywords/llc-resonant-converter","display_name":"LLC resonant converter","score":0.9990000128746033},{"id":"https://openalex.org/keywords/bidirectional-power-flow","display_name":"bidirectional power flow","score":0.8690000176429749},{"id":"https://openalex.org/keywords/dc-link-voltage-control","display_name":"DC bus voltage regulation","score":0.7129999995231628}],"concepts":[{"id":"https://openalex.org/C2778422915","wikidata":"https://www.wikidata.org/wiki/Q10302051","display_name":"Converters","level":3,"score":0.77892005443573},{"id":"https://openalex.org/C55118286","wikidata":"https://www.wikidata.org/wiki/Q634739","display_name":"Forward converter","level":4,"score":0.6150110960006714},{"id":"https://openalex.org/C100329506","wikidata":"https://www.wikidata.org/wiki/Q336439","display_name":"\u0106uk converter","level":4,"score":0.5729265213012695},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.5418643951416016},{"id":"https://openalex.org/C103303742","wikidata":"https://www.wikidata.org/wiki/Q1293595","display_name":"Flyback converter","level":4,"score":0.5290265083312988},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.520904004573822},{"id":"https://openalex.org/C78336795","wikidata":"https://www.wikidata.org/wiki/Q760134","display_name":"Boost converter","level":3,"score":0.4930538833141327},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.474405974149704},{"id":"https://openalex.org/C150818752","wikidata":"https://www.wikidata.org/wiki/Q83804","display_name":"Buck converter","level":3,"score":0.44995903968811035},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.44079646468162537},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.36429110169410706},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.3532198965549469},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.12511715292930603},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/tie.2015.2399273","doi":"https://doi.org/10.1109/tie.2015.2399273","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tie.2015.2399273","pdf_url":null,"source":{"id":"https://openalex.org/S58031724","display_name":"IEEE Transactions on Industrial Electronics","issn_l":"0278-0046","issn":["0278-0046","1557-9948"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-a","jufo-3","ki-jl-1","norway-2","poland-200","russia-white-list-1","vabb-shw"],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Industrial Electronics","raw_type":"journal-article"},{"id":"pmh:oai:scholarworks.unist.ac.kr:201301/12623","doi":null,"is_oa":false,"landing_page_url":"http://ieeexplore.ieee.org/xpl/articleDetails.jsp?arnumber=7031408","pdf_url":null,"source":{"id":"https://openalex.org/S4306401118","display_name":"Scholarworks@UNIST (Ulsan National Institute of Science and Technology)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I48566637","host_organization_name":"Ulsan National Institute of Science and Technology","host_organization_lineage":["https://openalex.org/I48566637"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"","raw_type":"ARTICLE"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy","score":0.9853000044822693},{"id":"https://metadata.un.org/sdg/9","display_name":"Industry, innovation and infrastructure","score":0.8970999717712402}],"study_designs":[],"awards":[],"funders":[{"id":"https://openalex.org/F4320322030","display_name":"Ministry of Science, ICT and Future Planning","ror":"https://ror.org/032e49973"}],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":36,"referenced_works":["https://openalex.org/W1711299841","https://openalex.org/W1963865073","https://openalex.org/W1990778263","https://openalex.org/W1994226822","https://openalex.org/W1994277329","https://openalex.org/W2008304264","https://openalex.org/W2019462594","https://openalex.org/W2024497895","https://openalex.org/W2059098247","https://openalex.org/W2076457412","https://openalex.org/W2080404496","https://openalex.org/W2082226609","https://openalex.org/W2100665834","https://openalex.org/W2103511841","https://openalex.org/W2104801260","https://openalex.org/W2108957158","https://openalex.org/W2109501622","https://openalex.org/W2113890330","https://openalex.org/W2114883930","https://openalex.org/W2117657076","https://openalex.org/W2117803131","https://openalex.org/W2118203870","https://openalex.org/W2125305968","https://openalex.org/W2125704611","https://openalex.org/W2127050485","https://openalex.org/W2131594137","https://openalex.org/W2136942349","https://openalex.org/W2137367046","https://openalex.org/W2142083809","https://openalex.org/W2146011910","https://openalex.org/W2146501232","https://openalex.org/W2159806935","https://openalex.org/W2163474410","https://openalex.org/W2164015411","https://openalex.org/W2166887358","https://openalex.org/W2801813668"],"related_works":["https://openalex.org/W2060772953","https://openalex.org/W3103950039","https://openalex.org/W2082226609","https://openalex.org/W2324881414","https://openalex.org/W2548500243","https://openalex.org/W2056011957","https://openalex.org/W2084796217","https://openalex.org/W2899029509","https://openalex.org/W2151890270","https://openalex.org/W95505218"],"abstract_inverted_index":{"This":[0,62],"paper":[1,63],"proposes":[2],"an":[3],"effective":[4,85],"test":[5],"bed":[6],"for":[7,28,36,83],"a":[8,24,33,41,53,70,74,79,89,99,117,123,130],"380-V":[9],"dc":[10,45,54,90],"distribution":[11,55],"system":[12,20,113,142],"using":[13,98,116,146],"isolated":[14,66,93],"power":[15,39,67,86,94,154],"converters.":[16,159],"The":[17,110],"proposed":[18,111],"test-bed":[19,112,141],"is":[21],"composed":[22],"of":[23,88,106,139,149],"grid-interactive":[25],"ac-dc":[26,72,120],"converter":[27,35,82,101],"regulating":[29],"the":[30,37,84,103,137,140,157],"dc-bus":[31],"voltage,":[32],"bidirectional":[34,71,75,119,125,153],"battery":[38],"interface,":[40],"renewable":[42],"energy":[43],"simulator,":[44],"home":[46],"appliances":[47],"modified":[48],"from":[49],"conventional":[50],"ac":[51],"components,":[52],"panel":[56],"board,":[57],"and":[58,78,102,108,129,152],"its":[59],"monitoring":[60],"system.":[61],"discusses":[64],"three":[65],"converters,":[68],"i.e.,":[69],"converter,":[73,77,122,128],"dc-dc":[76,81,126,133],"unidirectional":[80,132],"interface":[87],"bus.":[91],"These":[92],"converters":[95],"are":[96],"designed":[97],"dual-active-bridge":[100],"resonant":[104],"topologies":[105],"CLLC":[107],"LLC.":[109],"was":[114],"implemented":[115],"5-kW":[118],"prototype":[121,127,134,158],"3-kW":[124,131],"converter.":[135],"Finally,":[136],"performance":[138],"has":[143],"been":[144],"verified":[145],"practical":[147],"experiments":[148],"load":[150],"variations":[151],"flow,":[155],"employing":[156]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W1970900775","counts_by_year":[{"year":2026,"cited_by_count":3},{"year":2025,"cited_by_count":6},{"year":2024,"cited_by_count":4},{"year":2023,"cited_by_count":12},{"year":2022,"cited_by_count":16},{"year":2021,"cited_by_count":21},{"year":2020,"cited_by_count":22},{"year":2019,"cited_by_count":31},{"year":2018,"cited_by_count":24},{"year":2017,"cited_by_count":10},{"year":2016,"cited_by_count":10},{"year":2015,"cited_by_count":7}],"updated_date":"2026-11-21T10:27:49.728292","created_date":"2016-06-24T00:00:00"}
