{"id":"https://openalex.org/W1970586646","doi":"https://doi.org/10.11112/jksmi.2014.18.6.090","title":"Influence of Chloride Content of on Electrical Resistivity in Concrete","display_name":"Influence of Chloride Content of on Electrical Resistivity in Concrete","publication_year":2014,"publication_date":"2014-11-30","ids":{"openalex":"https://openalex.org/W1970586646","doi":"https://doi.org/10.11112/jksmi.2014.18.6.090","mag":"1970586646"},"language":"en","primary_location":{"id":"doi:10.11112/jksmi.2014.18.6.090","doi":"https://doi.org/10.11112/jksmi.2014.18.6.090","is_oa":false,"landing_page_url":"https://doi.org/10.11112/jksmi.2014.18.6.090","pdf_url":null,"source":{"id":"https://openalex.org/S4210179316","display_name":"Journal of the Korea institute for structural maintenance inspection","issn_l":"2234-6937","issn":["2234-6937","2287-6979"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":["kci-registered"],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Journal of the Korea institute for structural maintenance and inspection","raw_type":"journal-article"},"volume":null,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5090352840","display_name":"In Seok Yoon","orcid":"https://orcid.org/0000-0003-2499-8824","observed_orcids":["https://orcid.org/0000-0003-2499-8824"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"In-Seok Yoon","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"last","author":{"id":"https://openalex.org/A5071957384","display_name":"Jin-Won Nam","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Jin-Won Nam","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.5849,"has_fulltext":false,"cited_by_count":6,"citation_normalized_percentile":{"value":0.74004595,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":87,"max":93},"biblio":{"volume":"18","issue":"6","first_page":"90","last_page":"96"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11850","display_name":"Concrete Corrosion and Durability","score":0.9970999956130981,"subfield":{"id":"https://openalex.org/subfields/2205","display_name":"Civil and Structural Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11850","display_name":"Concrete Corrosion and Durability","score":0.9970999956130981,"subfield":{"id":"https://openalex.org/subfields/2205","display_name":"Civil and Structural Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12682","display_name":"Smart Materials for Construction","score":0.00279999990016222,"subfield":{"id":"https://openalex.org/subfields/2205","display_name":"Civil and Structural Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10033","display_name":"Concrete and Cement Materials Research","score":9.999999747378752e-05,"subfield":{"id":"https://openalex.org/subfields/2205","display_name":"Civil and Structural Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/concrete-resistivity","display_name":"concrete resistivity","score":0.8619999885559082},{"id":"https://openalex.org/keywords/chloride-concentration","display_name":"chloride concentration","score":0.9639999866485596},{"id":"https://openalex.org/keywords/reinforcement-corrosion","display_name":"reinforcement corrosion","score":0.7379999756813049},{"id":"https://openalex.org/keywords/chloride-penetration","display_name":"chloride penetration","score":0.9610000252723694},{"id":"https://openalex.org/keywords/corrosion-rate","display_name":"corrosion rate","score":0.6370000243186951},{"id":"https://openalex.org/keywords/moisture-content","display_name":"moisture content","score":0.7609999775886536},{"id":"https://openalex.org/keywords/carbonation","display_name":"carbonation","score":0.7599999904632568}],"concepts":[{"id":"https://openalex.org/C69990965","wikidata":"https://www.wikidata.org/wiki/Q65402698","display_name":"Electrical resistivity and conductivity","level":2,"score":0.8357793092727661},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.6574368476867676},{"id":"https://openalex.org/C2778695967","wikidata":"https://www.wikidata.org/wiki/Q44791900","display_name":"Chloride","level":2,"score":0.605995774269104},{"id":"https://openalex.org/C2778152352","wikidata":"https://www.wikidata.org/wiki/Q5165061","display_name":"Content (measure theory)","level":2,"score":0.42063701152801514},{"id":"https://openalex.org/C159985019","wikidata":"https://www.wikidata.org/wiki/Q181790","display_name":"Composite material","level":1,"score":0.40720701217651367},{"id":"https://openalex.org/C191897082","wikidata":"https://www.wikidata.org/wiki/Q11467","display_name":"Metallurgy","level":1,"score":0.3322460651397705},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.17898067831993103},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.09986600279808044},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.09203428030014038},{"id":"https://openalex.org/C134306372","wikidata":"https://www.wikidata.org/wiki/Q7754","display_name":"Mathematical analysis","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.11112/jksmi.2014.18.6.090","doi":"https://doi.org/10.11112/jksmi.2014.18.6.090","is_oa":false,"landing_page_url":"https://doi.org/10.11112/jksmi.2014.18.6.090","pdf_url":null,"source":{"id":"https://openalex.org/S4210179316","display_name":"Journal of the Korea institute for structural maintenance inspection","issn_l":"2234-6937","issn":["2234-6937","2287-6979"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":["kci-registered"],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Journal of the Korea institute for structural maintenance and inspection","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":7,"referenced_works":["https://openalex.org/W1497200036","https://openalex.org/W1971737541","https://openalex.org/W1999998645","https://openalex.org/W2054956386","https://openalex.org/W2076667124","https://openalex.org/W2081106837","https://openalex.org/W2124968163"],"related_works":["https://openalex.org/W3084343088","https://openalex.org/W2072353530","https://openalex.org/W2000779048","https://openalex.org/W2498869083","https://openalex.org/W2902486906","https://openalex.org/W2616958781","https://openalex.org/W3039218596","https://openalex.org/W2900831441","https://openalex.org/W6990592986","https://openalex.org/W2974809513"],"abstract_inverted_index":{"The":[0,23,106,151],"electrical":[1,63,128,168,235],"resistivity":[2,41,54,87,129,169,182,206,218,236],"of":[3,14,25,34,88,130,142,147,153,163,171,183,205,207,222,237],"concrete":[4,26,89,184,194,208,238],"can":[5],"be":[6],"related":[7,43],"to":[8,29,44,49,138,157,232],"two":[9],"processes":[10],"involved":[11],"in":[12,75,95,113],"corrosion":[13,36,51],"reinforcement:":[15],"initiation":[16],"(chloride":[17],"penetration)":[18],"and":[19,48,72,100,159,185],"propagation":[20],"(corrosion":[21],"rate).":[22],"resisistivity":[24],"structure":[27],"exposed":[28],"chloride":[30,46,143,164,177,196,223,240],"indicates":[31],"the":[32,62,67,86,92,96,114,122,140,145,161,181,186,229,234],"risk":[33],"early":[35,212],"damage,":[37],"because":[38],"a":[39,56,76,189,199],"low":[40],"is":[42,55,66,108,156],"rapid":[45],"penetration":[47],"high":[50],"rate.":[52],"Concrete":[53],"geometry-independent":[57],"material":[58],"property":[59],"that":[60,85,176],"describes":[61],"resistance,":[64],"which":[65],"ratio":[68],"between":[69,124],"applied":[70],"voltage":[71],"resulting":[73],"current":[74,107],"unit":[77],"cell.":[78],"In":[79],"previous":[80],"study,":[81],"it":[82],"was":[83,174,209,219],"realized":[84],"depended":[90],"on":[91,121,127,144,166],"moisture":[93,125],"content":[94,126,165,178],"concrete,":[97,131],"microstructural":[98],"properties,":[99],"environmental":[101],"attack":[102],"such":[103],"as":[104],"carbonation.":[105],"carried":[109],"by":[110],"ions":[111,197],"dissolved":[112],"pore":[115],"liquid.":[116],"While":[117],"some":[118],"data":[119],"exist":[120],"relationship":[123,187],"very":[132],"little":[133],"research":[134],"has":[135],"been":[136],"conducted":[137],"evaluate":[139],"effect":[141,162],"conduction":[146],"electricity":[148],"through":[149],"concrete.":[150,172],"purpose":[152],"this":[154,226],"study":[155],"examine":[158],"quantify":[160],"surface":[167],"measurement":[170],"It":[173],"obvious":[175],"had":[179,198],"influenced":[180],"showed":[188],"linear":[190],"function.":[191],"That":[192],"is,":[193],"with":[195,239],"comparatively":[200],"lower":[201],"resistivity.":[202],"Decreasing":[203],"rate":[204],"clear":[210],"at":[211],"time,":[213],"however,":[214],"after":[215],"50":[216],"days":[217],"constant":[220],"irrespective":[221],"concentration.":[224],"Conclusively,":[225],"paper":[227],"suggested":[228],"quantitive":[230],"solution":[231],"depict":[233],"content.":[241]},"counts_by_year":[{"year":2025,"cited_by_count":1},{"year":2024,"cited_by_count":1},{"year":2023,"cited_by_count":1},{"year":2021,"cited_by_count":1},{"year":2020,"cited_by_count":1},{"year":2017,"cited_by_count":1}],"updated_date":"2026-11-07T11:25:07.637180","created_date":"2016-06-24T00:00:00"}
