{"id":"https://openalex.org/W1968232109","doi":"https://doi.org/10.1002/eej.4391150403","title":"Effective lightning protection schemes for distribution line","display_name":"Effective lightning protection schemes for distribution line","publication_year":1995,"publication_date":"1995-06-15","ids":{"openalex":"https://openalex.org/W1968232109","doi":"https://doi.org/10.1002/eej.4391150403","mag":"1968232109"},"language":"en","primary_location":{"id":"doi:10.1002/eej.4391150403","doi":"https://doi.org/10.1002/eej.4391150403","is_oa":false,"landing_page_url":"https://doi.org/10.1002/eej.4391150403","pdf_url":null,"source":{"id":"https://openalex.org/S167620381","display_name":"Electrical Engineering in Japan","issn_l":"0424-7760","issn":["0424-7760","1520-6416"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":["dongbi-c","norway-1","poland-20","russia-white-list-4"],"host_organization":"https://openalex.org/P4310320595","host_organization_name":"Wiley","host_organization_lineage":["https://openalex.org/P4310320595"],"host_organization_lineage_names":["Wiley"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Electrical Engineering in Japan","raw_type":"journal-article"},"volume":null,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5059588782","display_name":"Tokuji Masaki","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I197274945","display_name":"Nagoya Institute of Technology","ror":"https://ror.org/055yf1005","country_code":"JP","type":"education","lineage":["https://openalex.org/I197274945"]},{"id":"https://openalex.org/I4210161071","display_name":"Shikoku Research Institute","ror":"https://ror.org/05mv3wa59","country_code":"JP","type":"facility","lineage":["https://openalex.org/I4210161071"]},{"id":"https://openalex.org/I4405274376","display_name":"Shikoku Electric Power Co., Inc. (Japan)","ror":"https://ror.org/01m0bwf79","country_code":"JP","type":"company","lineage":["https://openalex.org/I4405274376"]}],"countries":["JP"],"is_corresponding":false,"raw_author_name":"Tokuji Masaki","raw_affiliation_strings":["Shikoku Research Institute","Tokuji Masaki received his B.E. degree in 1972 from the Department of Electrical Engineering, Nagoya Institute of Technology. He joined Shikoku Electric Power Co. in April of the same year. He has been at Shikoku Research Institute since 1991. He is engaged mainly in research on various technologies with respect to the improvement of power supply reliability of distribution systems"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Shikoku Research Institute","institution_ids":["https://openalex.org/I4210161071"]},{"raw_affiliation_string":"Tokuji Masaki received his B.E. degree in 1972 from the Department of Electrical Engineering, Nagoya Institute of Technology. He joined Shikoku Electric Power Co. in April of the same year. He has been at Shikoku Research Institute since 1991. He is engaged mainly in research on various technologies with respect to the improvement of power supply reliability of distribution systems","institution_ids":["https://openalex.org/I197274945","https://openalex.org/I4405274376"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5035174420","display_name":"Kouji Higuchi","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4405274376","display_name":"Shikoku Electric Power Co., Inc. (Japan)","ror":"https://ror.org/01m0bwf79","country_code":"JP","type":"company","lineage":["https://openalex.org/I4405274376"]},{"id":"https://openalex.org/I922474255","display_name":"Tokushima University","ror":"https://ror.org/044vy1d05","country_code":"JP","type":"education","lineage":["https://openalex.org/I922474255"]}],"countries":["JP"],"is_corresponding":false,"raw_author_name":"Kouji Higuchi","raw_affiliation_strings":["Kouji Higuchi received his M.E. degree in 1986 from the Department of Electrical Engineering, The University of Tokushima. He joined Shikoku Electric Power Co. in April of the same year. He joined Shikoku Research Institute in April 1990. He was engaged mainly in research on lightning protection measures of distribution lines. He has been at Tokushima Branch of Shikoku Electric Power Co. since March 1994","Shikoku Electric Power Co"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Kouji Higuchi received his M.E. degree in 1986 from the Department of Electrical Engineering, The University of Tokushima. He joined Shikoku Electric Power Co. in April of the same year. He joined Shikoku Research Institute in April 1990. He was engaged mainly in research on lightning protection measures of distribution lines. He has been at Tokushima Branch of Shikoku Electric Power Co. since March 1994","institution_ids":["https://openalex.org/I4405274376","https://openalex.org/I922474255"]},{"raw_affiliation_string":"Shikoku Electric Power Co","institution_ids":["https://openalex.org/I4405274376"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5110441819","display_name":"Yoshihide Yokoi","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I135598925","display_name":"Kyushu University","ror":"https://ror.org/00p4k0j84","country_code":"JP","type":"education","lineage":["https://openalex.org/I135598925"]},{"id":"https://openalex.org/I4210152396","display_name":"Society of Instrument and Control Engineers","ror":"https://ror.org/04sksc249","country_code":"JP","type":"nonprofit","lineage":["https://openalex.org/I4210152396"]},{"id":"https://openalex.org/I4405257877","display_name":"The Illuminating Engineering Institute of Japan","ror":"https://ror.org/05s76re36","country_code":"JP","type":"nonprofit","lineage":["https://openalex.org/I4405257877"]},{"id":"https://openalex.org/I922474255","display_name":"Tokushima University","ror":"https://ror.org/044vy1d05","country_code":"JP","type":"education","lineage":["https://openalex.org/I922474255"]}],"countries":["JP"],"is_corresponding":false,"raw_author_name":"Yoshihide Yokoi","raw_affiliation_strings":["The University of Tokushima","Yoshihide Yokoi received his B.E. and Ph.D. degrees in 1953 and 1971, respectively, from Kyushu University. At the University of Tokushima he became a Research Associate in April 1952 and was promoted to Lecturer in 1958, Associate Professor in 1968, and Professor in 1972. He is engaged mainly in research on creeping discharge and electromagnetic environments. He is a member of the Illuminating Engineering Institute of Japan; the Institute of Electrostatics Japan; and the Society of Instrument and Control Engineering","Yoshihide Yokoi received his B.E. and Ph.D. degrees in 1953 and 1971, respectively, from Kyushu University. At the University of Tokushima he became a Research Associate in April 1952 and was promoted to Lecturer in 1958, Associate Professor in 1968, and Professor in 1972. He is engaged mainly in research on creeping discharge and electromagnetic environments. He is a member of the Illuminating Engineering Institute of Japan","the Institute of Electrostatics Japan","the Society of Instrument and Control Engineering"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"The University of Tokushima","institution_ids":["https://openalex.org/I922474255"]},{"raw_affiliation_string":"Yoshihide Yokoi received his B.E. and Ph.D. degrees in 1953 and 1971, respectively, from Kyushu University. At the University of Tokushima he became a Research Associate in April 1952 and was promoted to Lecturer in 1958, Associate Professor in 1968, and Professor in 1972. He is engaged mainly in research on creeping discharge and electromagnetic environments. He is a member of the Illuminating Engineering Institute of Japan; the Institute of Electrostatics Japan; and the Society of Instrument and Control Engineering","institution_ids":["https://openalex.org/I135598925","https://openalex.org/I922474255"]},{"raw_affiliation_string":"Yoshihide Yokoi received his B.E. and Ph.D. degrees in 1953 and 1971, respectively, from Kyushu University. At the University of Tokushima he became a Research Associate in April 1952 and was promoted to Lecturer in 1958, Associate Professor in 1968, and Professor in 1972. He is engaged mainly in research on creeping discharge and electromagnetic environments. He is a member of the Illuminating Engineering Institute of Japan","institution_ids":["https://openalex.org/I135598925","https://openalex.org/I4405257877","https://openalex.org/I922474255"]},{"raw_affiliation_string":"the Institute of Electrostatics Japan","institution_ids":[]},{"raw_affiliation_string":"the Society of Instrument and Control Engineering","institution_ids":["https://openalex.org/I4210152396"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":7,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":{"value":2630,"currency":"USD","value_usd":2630},"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":1,"citation_normalized_percentile":{"value":0.0,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":88,"max":93},"biblio":{"volume":"115","issue":"4","first_page":"27","last_page":"41"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10787","display_name":"Lightning and Electromagnetic Phenomena","score":1.0,"subfield":{"id":"https://openalex.org/subfields/1902","display_name":"Atmospheric Science"},"field":{"id":"https://openalex.org/fields/19","display_name":"Earth and Planetary Sciences"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10787","display_name":"Lightning and Electromagnetic Phenomena","score":1.0,"subfield":{"id":"https://openalex.org/subfields/1902","display_name":"Atmospheric Science"},"field":{"id":"https://openalex.org/fields/19","display_name":"Earth and Planetary Sciences"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14502","display_name":"High-Voltage Power Transmission Systems","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/lightning-protection","display_name":"lightning protection","score":0.9150000214576721},{"id":"https://openalex.org/keywords/power-distribution-lines","display_name":"distribution lines","score":0.9049999713897705},{"id":"https://openalex.org/keywords/lightning-outages","display_name":"lightning outages","score":0.8690000176429749},{"id":"https://openalex.org/keywords/direct-lightning-stroke","display_name":"direct lightning stroke","score":0.8859999775886536},{"id":"https://openalex.org/keywords/lightning-overvoltage","display_name":"lightning overvoltage","score":0.9390000104904175},{"id":"https://openalex.org/keywords/lightning-protection-devices","display_name":"lightning protection devices","score":0.9129999876022339},{"id":"https://openalex.org/keywords/ground-wire","display_name":"ground wire","score":0.8880000114440918},{"id":"https://openalex.org/keywords/emtp-simulation","display_name":"EMTP simulation","score":0.6819999814033508},{"id":"https://openalex.org/keywords/economic-evaluation","display_name":"economic evaluation","score":0.8370000123977661}],"concepts":[{"id":"https://openalex.org/C69398868","wikidata":"https://www.wikidata.org/wiki/Q129052","display_name":"Lightning (connector)","level":3,"score":0.7702420949935913},{"id":"https://openalex.org/C105161833","wikidata":"https://www.wikidata.org/wiki/Q5530572","display_name":"Lightning arrester","level":2,"score":0.6076360940933228},{"id":"https://openalex.org/C2778363592","wikidata":"https://www.wikidata.org/wiki/Q5374837","display_name":"Emtp","level":4,"score":0.5710573196411133},{"id":"https://openalex.org/C15703209","wikidata":"https://www.wikidata.org/wiki/Q333883","display_name":"Overvoltage","level":3,"score":0.5628955960273743},{"id":"https://openalex.org/C182236062","wikidata":"https://www.wikidata.org/wiki/Q15120872","display_name":"Lightning strike","level":3,"score":0.45951735973358154},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.4388725757598877},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.36763668060302734},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.17954108119010925},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.17608585953712463},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0831405520439148},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.05994650721549988},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1002/eej.4391150403","doi":"https://doi.org/10.1002/eej.4391150403","is_oa":false,"landing_page_url":"https://doi.org/10.1002/eej.4391150403","pdf_url":null,"source":{"id":"https://openalex.org/S167620381","display_name":"Electrical Engineering in Japan","issn_l":"0424-7760","issn":["0424-7760","1520-6416"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":["dongbi-c","norway-1","poland-20","russia-white-list-4"],"host_organization":"https://openalex.org/P4310320595","host_organization_name":"Wiley","host_organization_lineage":["https://openalex.org/P4310320595"],"host_organization_lineage_names":["Wiley"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Electrical Engineering in Japan","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/9","score":0.6773999929428101,"display_name":"Industry, innovation and infrastructure"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W2510668546","https://openalex.org/W2513869877","https://openalex.org/W2087741315","https://openalex.org/W2377559608","https://openalex.org/W2153402184","https://openalex.org/W2514054592","https://openalex.org/W4210527555","https://openalex.org/W2187829296","https://openalex.org/W201934148","https://openalex.org/W4402489894"],"abstract_inverted_index":{"Abstract":[0],"The":[1,155],"causes":[2],"of":[3,22,46,54,72,80,143,150],"lightning":[4,10,14,24,29,47,57,73,82,89,93,99,118,123,137,144,152,158],"outage":[5,100,124],"are":[6,17,161],"subdivided":[7],"into":[8],"direct":[9,88,117],"strokes":[11],"and":[12,38,52,75,91,120,163],"induced":[13,92,122,136],"strokes,":[15],"which":[16],"identified":[18],"by":[19,85,148],"the":[20,23,27,36,44,69,78,102,107,116,121,135,141,170],"characteristics":[21,71],"overvoltage.":[25],"In":[26,104],"past,":[28],"protection":[30,48,83,145,153,159],"devices":[31,84,146],"were":[32],"directed":[33],"mainly":[34],"toward":[35],"latter,":[37],"attention":[39],"has":[40,112,131],"been":[41,113,132],"focused":[42],"on":[43,166,169],"installation":[45],"devices,":[49],"ground":[50],"wires,":[51],"reinforcement":[53],"insulators.":[55],"However,":[56],"outages":[58],"continue":[59],"to":[60,67,76,97,115,134,139],"occur.":[61],"Thus":[62],"it":[63],"is":[64],"extremely":[65],"important":[66],"clarify":[68],"fault":[70],"surges":[74],"study":[77,140],"effectiveness":[79,142],"various":[81,151],"considering":[86],"both":[87],"stroke":[90,94,138],"in":[95,101],"order":[96],"prevent":[98],"future.":[103],"this":[105],"research,":[106],"electromagnetic":[108],"transients":[109],"program":[110,126],"(EMTP)":[111],"applied":[114,133],"stroke,":[119],"analysis":[125],"for":[127],"multiple":[128],"conductor":[129],"systems":[130],"provided":[147],"combination":[149],"devices.":[154],"most":[156],"effective":[157],"schemes":[160],"analyzed":[162],"evaluated":[164],"based":[165],"verification":[167],"tests":[168],"full":[171],"scale":[172],"models":[173],"as":[174,176],"well":[175],"economic":[177],"considerations.":[178]},"counts_by_year":[{"year":2014,"cited_by_count":1}],"updated_date":"2026-09-23T05:00:35.095934","created_date":"2016-06-24T00:00:00"}
