{"id":"https://openalex.org/W1966806263","doi":"https://doi.org/10.1063/1.1770153","title":"An Apparatus for Measuring Air Flow During Inspiration","display_name":"An Apparatus for Measuring Air Flow During Inspiration","publication_year":1943,"publication_date":"1943-06-01","ids":{"openalex":"https://openalex.org/W1966806263","doi":"https://doi.org/10.1063/1.1770153","mag":"1966806263"},"language":"en","primary_location":{"id":"doi:10.1063/1.1770153","doi":"https://doi.org/10.1063/1.1770153","is_oa":false,"landing_page_url":"https://doi.org/10.1063/1.1770153","pdf_url":null,"source":{"id":"https://openalex.org/S31010182","display_name":"Review of Scientific Instruments","issn_l":"0034-6748","issn":["0034-6748","1089-7623","1527-2400"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-c","jufo-1","ki-jl-1","medline","norway-1","poland-70","russia-white-list-2","vabb-shw"],"host_organization":"https://openalex.org/P4310320257","host_organization_name":"American Institute of Physics","host_organization_lineage":["https://openalex.org/P4310320257"],"host_organization_lineage_names":["American Institute of Physics"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Review of Scientific Instruments","raw_type":"journal-article"},"volume":null,"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":null,"display_name":"Robert C. Lee","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I136199984","display_name":"Harvard University","ror":"https://ror.org/03vek6s52","country_code":"US","type":"education","lineage":["https://openalex.org/I136199984"]},{"id":"https://openalex.org/I196817621","display_name":"Carnegie Institution for Science","ror":"https://ror.org/04jr01610","country_code":"US","type":"nonprofit","lineage":["https://openalex.org/I196817621"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Robert C. Lee","raw_affiliation_strings":["Nutrition Laboratory of the Carnegie Institution of Washington and Department of Industrial Hygiene, Harvard School of Public Health, Boston, Massachusetts"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Nutrition Laboratory of the Carnegie Institution of Washington and Department of Industrial Hygiene, Harvard School of Public Health, Boston, Massachusetts","institution_ids":["https://openalex.org/I136199984","https://openalex.org/I196817621"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5111482512","display_name":"Leslie Silverman","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I136199984","display_name":"Harvard University","ror":"https://ror.org/03vek6s52","country_code":"US","type":"education","lineage":["https://openalex.org/I136199984"]},{"id":"https://openalex.org/I196817621","display_name":"Carnegie Institution for Science","ror":"https://ror.org/04jr01610","country_code":"US","type":"nonprofit","lineage":["https://openalex.org/I196817621"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Leslie Silverman","raw_affiliation_strings":["Nutrition Laboratory of the Carnegie Institution of Washington and Department of Industrial Hygiene, Harvard School of Public Health, Boston, Massachusetts"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Nutrition Laboratory of the Carnegie Institution of Washington and Department of Industrial Hygiene, Harvard School of Public Health, Boston, Massachusetts","institution_ids":["https://openalex.org/I136199984","https://openalex.org/I196817621"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":3.8286,"has_fulltext":false,"cited_by_count":13,"citation_normalized_percentile":{"value":0.88778055,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"14","issue":"6","first_page":"174","last_page":"181"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T12537","display_name":"Flow Measurement and Analysis","score":0.5019999742507935,"subfield":{"id":"https://openalex.org/subfields/2211","display_name":"Mechanics of Materials"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12537","display_name":"Flow Measurement and Analysis","score":0.5019999742507935,"subfield":{"id":"https://openalex.org/subfields/2211","display_name":"Mechanics of Materials"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11700","display_name":"Hemodynamic Monitoring and Therapy","score":0.15330000221729279,"subfield":{"id":"https://openalex.org/subfields/2746","display_name":"Surgery"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.06310000270605087,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/airflow-measurement","display_name":"air flow measurement","score":0.8550000190734863},{"id":"https://openalex.org/keywords/inspiration","display_name":"inspiration","score":0.6869999766349792},{"id":"https://openalex.org/keywords/respiratory-physiology","display_name":"respiratory physiology","score":0.8320000171661377},{"id":"https://openalex.org/keywords/flowmeter-design","display_name":"flowmeter design","score":0.5059999823570251},{"id":"https://openalex.org/keywords/respirators","display_name":"respirators","score":0.38499999046325684}],"concepts":[{"id":"https://openalex.org/C116067010","wikidata":"https://www.wikidata.org/wiki/Q4698686","display_name":"Airflow","level":2,"score":0.6759852170944214},{"id":"https://openalex.org/C2781355719","wikidata":"https://www.wikidata.org/wiki/Q2080698","display_name":"Deflection (physics)","level":2,"score":0.554636538028717},{"id":"https://openalex.org/C3020810636","wikidata":"https://www.wikidata.org/wiki/Q456026","display_name":"Flow resistance","level":3,"score":0.5333027839660645},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.5163840055465698},{"id":"https://openalex.org/C24890656","wikidata":"https://www.wikidata.org/wiki/Q82811","display_name":"Acoustics","level":1,"score":0.49044153094291687},{"id":"https://openalex.org/C198394728","wikidata":"https://www.wikidata.org/wiki/Q3695508","display_name":"Vibration","level":2,"score":0.4715045988559723},{"id":"https://openalex.org/C57879066","wikidata":"https://www.wikidata.org/wiki/Q41217","display_name":"Mechanics","level":1,"score":0.44150251150131226},{"id":"https://openalex.org/C110407247","wikidata":"https://www.wikidata.org/wiki/Q122508","display_name":"Inertia","level":2,"score":0.44097113609313965},{"id":"https://openalex.org/C172120300","wikidata":"https://www.wikidata.org/wiki/Q1134348","display_name":"Volumetric flow rate","level":2,"score":0.4232105612754822},{"id":"https://openalex.org/C38349280","wikidata":"https://www.wikidata.org/wiki/Q1434290","display_name":"Flow (mathematics)","level":2,"score":0.41079390048980713},{"id":"https://openalex.org/C120665830","wikidata":"https://www.wikidata.org/wiki/Q14620","display_name":"Optics","level":1,"score":0.3606102168560028},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.3141625225543976},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.25501155853271484},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.12379190325737},{"id":"https://openalex.org/C74650414","wikidata":"https://www.wikidata.org/wiki/Q11397","display_name":"Classical mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1063/1.1770153","doi":"https://doi.org/10.1063/1.1770153","is_oa":false,"landing_page_url":"https://doi.org/10.1063/1.1770153","pdf_url":null,"source":{"id":"https://openalex.org/S31010182","display_name":"Review of Scientific Instruments","issn_l":"0034-6748","issn":["0034-6748","1089-7623","1527-2400"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-c","jufo-1","ki-jl-1","medline","norway-1","poland-70","russia-white-list-2","vabb-shw"],"host_organization":"https://openalex.org/P4310320257","host_organization_name":"American Institute of Physics","host_organization_lineage":["https://openalex.org/P4310320257"],"host_organization_lineage_names":["American Institute of Physics"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Review of Scientific Instruments","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[],"sustainable_development_goals_aurora":[],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":7,"referenced_works":["https://openalex.org/W1536379056","https://openalex.org/W1981496227","https://openalex.org/W2023180791","https://openalex.org/W2030603800","https://openalex.org/W2320939534","https://openalex.org/W2322389753","https://openalex.org/W4232524832"],"related_works":["https://openalex.org/W2083112918","https://openalex.org/W2064625179","https://openalex.org/W2399664586","https://openalex.org/W2050481735","https://openalex.org/W1879780590","https://openalex.org/W2021368147","https://openalex.org/W2590072504","https://openalex.org/W2101755231","https://openalex.org/W2037500518","https://openalex.org/W2183622429"],"abstract_inverted_index":{"Measurement":[0],"of":[1,4,6,19,54,63,69,88,107,121],"the":[2,17,61,70,79,89,95,108,137],"rate":[3],"flow":[5],"air":[7,49,92,113],"during":[8],"inspiration":[9],"is":[10,72,97,110],"important":[11],"in":[12],"respiratory":[13,21,127],"physiology":[14],"and":[15,31,78,115,119,133],"for":[16,40],"design":[18],"protective":[20],"devices.":[22],"Methods":[23],"that":[24],"have":[25],"been":[26],"used":[27],"previously":[28],"are":[29],"described":[30],"their":[32],"limitations":[33],"explained.":[34],"A":[35,129],"new":[36],"instrument":[37,52,96],"was":[38],"constructed":[39],"such":[41],"measurements,":[42],"which":[43],"offers":[44],"no":[45],"appreciable":[46],"resistance":[47,131],"to":[48,74,82],"flow.":[50],"This":[51],"consists":[53],"a":[55,64,75,83,101],"microscopic":[56],"platinum":[57],"wire":[58,71,90,109],"suspended":[59],"across":[60],"diameter":[62],"31.6-mm":[65],"tube.":[66],"One":[67],"end":[68,81],"attached":[73],"fixed":[76],"point":[77],"other":[80],"fine":[84],"spring.":[85],"The":[86,105],"displacement":[87],"when":[91],"flows":[93],"through":[94],"recorded":[98],"photographically":[99],"by":[100],"moving":[102],"paper":[103],"camera.":[104],"deflection":[106],"linear":[111],"with":[112,126],"flow,":[114],"its":[116],"inertia,":[117],"lag,":[118],"frequency":[120],"vibration":[122],"do":[123],"not":[124],"interfere":[125],"measurements.":[128],"low":[130],"valve":[132],"mask":[134],"system":[135],"complete":[136],"apparatus.":[138]},"counts_by_year":[],"updated_date":"2026-10-14T16:39:01.820549","created_date":"2016-06-24T00:00:00"}
