{"id":"https://openalex.org/W1965263446","doi":"https://doi.org/10.3109/03091909109023705","title":"Clinical evaluation of the Philips 5306B electronic blood pressure monitord","display_name":"Clinical evaluation of the Philips 5306B electronic blood pressure monitord","publication_year":1991,"publication_date":"1991-01-01","ids":{"openalex":"https://openalex.org/W1965263446","doi":"https://doi.org/10.3109/03091909109023705","mag":"1965263446","pmid":"https://pubmed.ncbi.nlm.nih.gov/1800749"},"language":"en","primary_location":{"id":"doi:10.3109/03091909109023705","doi":"https://doi.org/10.3109/03091909109023705","is_oa":false,"landing_page_url":"https://doi.org/10.3109/03091909109023705","pdf_url":null,"source":{"id":"https://openalex.org/S30889892","display_name":"Journal of Medical Engineering & Technology","issn_l":"0309-1902","issn":["0309-1902","1464-522X"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","jufo-1","ki-jl-1","medline","norway-1","poland-70","russia-white-list-2","vabb-shw"],"host_organization":"https://openalex.org/P4310320547","host_organization_name":"Taylor & Francis","host_organization_lineage":["https://openalex.org/P4310320547","https://openalex.org/P4310320449"],"host_organization_lineage_names":["Taylor & Francis","Informa"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Journal of Medical Engineering &amp; Technology","raw_type":"journal-article"},"volume":null,"type":"article","is_traditional":true,"indexed_in":["crossref","pubmed"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5113560211","display_name":"Casey Hall","orcid":"https://orcid.org/0000-0002-1931-0063","observed_orcids":["https://orcid.org/0000-0002-1931-0063"]},"institutions":[{"id":"https://openalex.org/I2800549715","display_name":"Royal United Hospital","ror":"https://ror.org/00a858n67","country_code":"GB","type":"healthcare","lineage":["https://openalex.org/I2800549715","https://openalex.org/I4210161895"]}],"countries":["GB"],"is_corresponding":false,"raw_author_name":"C. L. Hall","raw_affiliation_strings":["Royal United Hospital, Bath, UK","Royal United Hospital, Combe Park Bath BA1 3NG, UK"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Royal United Hospital, Bath, UK","institution_ids":["https://openalex.org/I2800549715"]},{"raw_affiliation_string":"Royal United Hospital, Combe Park Bath BA1 3NG, UK","institution_ids":["https://openalex.org/I2800549715"]}]},{"author_position":"middle","author":{"id":null,"display_name":"J. Goodfellow","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I2800549715","display_name":"Royal United Hospital","ror":"https://ror.org/00a858n67","country_code":"GB","type":"healthcare","lineage":["https://openalex.org/I2800549715","https://openalex.org/I4210161895"]}],"countries":["GB"],"is_corresponding":false,"raw_author_name":"J. Goodfellow","raw_affiliation_strings":["Royal United Hospital, Combe Park, Bath, BA1 3NG, UK"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Royal United Hospital, Combe Park, Bath, BA1 3NG, UK","institution_ids":["https://openalex.org/I2800549715"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5109145894","display_name":"Jonathon H. Waites","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I2800549715","display_name":"Royal United Hospital","ror":"https://ror.org/00a858n67","country_code":"GB","type":"healthcare","lineage":["https://openalex.org/I2800549715","https://openalex.org/I4210161895"]}],"countries":["GB"],"is_corresponding":false,"raw_author_name":"J. Waites","raw_affiliation_strings":["Royal United Hospital, Combe Park, Bath, BA1 3NG, UK"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Royal United Hospital, Combe Park, Bath, BA1 3NG, UK","institution_ids":["https://openalex.org/I2800549715"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I2800549715"],"apc_list":null,"apc_paid":null,"fwci":0.7071,"has_fulltext":false,"cited_by_count":2,"citation_normalized_percentile":{"value":0.69025681,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"15","issue":"4-5","first_page":"177","last_page":"179"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10144","display_name":"Blood Pressure and Hypertension Studies","score":0.9976000189781189,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},"topics":[{"id":"https://openalex.org/T10144","display_name":"Blood Pressure and Hypertension Studies","score":0.9976000189781189,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.0012000000569969416,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10924","display_name":"Cardiovascular Health and Disease Prevention","score":0.00019999999494757503,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/electronic-blood-pressure-monitor","display_name":"electronic blood pressure monitor","score":0.9539999961853027},{"id":"https://openalex.org/keywords/mercury-manometer","display_name":"mercury manometer","score":0.7620000243186951},{"id":"https://openalex.org/keywords/device-validation","display_name":"device validation","score":0.597000002861023},{"id":"https://openalex.org/keywords/home-blood-pressure-monitoring","display_name":"home blood pressure monitoring","score":0.7129999995231628},{"id":"https://openalex.org/keywords/measurement-accuracy","display_name":"measurement accuracy","score":0.4819999933242798},{"id":"https://openalex.org/keywords/crossover-comparison","display_name":"crossover comparison","score":0.382999986410141}],"concepts":[{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.39323732256889343},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3493373990058899},{"id":"https://openalex.org/C136229726","wikidata":"https://www.wikidata.org/wiki/Q327092","display_name":"Biomedical engineering","level":1,"score":0.33849191665649414}],"mesh":[{"descriptor_ui":"D001794","descriptor_name":"Blood Pressure","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D005069","descriptor_name":"Evaluation Studies as Topic","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012016","descriptor_name":"Reference Values","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012044","descriptor_name":"Regression Analysis","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D015924","descriptor_name":"Blood Pressure Monitors","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true}],"locations_count":2,"locations":[{"id":"doi:10.3109/03091909109023705","doi":"https://doi.org/10.3109/03091909109023705","is_oa":false,"landing_page_url":"https://doi.org/10.3109/03091909109023705","pdf_url":null,"source":{"id":"https://openalex.org/S30889892","display_name":"Journal of Medical Engineering & Technology","issn_l":"0309-1902","issn":["0309-1902","1464-522X"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","jufo-1","ki-jl-1","medline","norway-1","poland-70","russia-white-list-2","vabb-shw"],"host_organization":"https://openalex.org/P4310320547","host_organization_name":"Taylor & Francis","host_organization_lineage":["https://openalex.org/P4310320547","https://openalex.org/P4310320449"],"host_organization_lineage_names":["Taylor & Francis","Informa"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Journal of Medical Engineering &amp; Technology","raw_type":"journal-article"},{"id":"pmid:1800749","doi":null,"is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/1800749","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Journal of medical engineering & technology","raw_type":"Clinical Trial"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.9537000060081482,"id":"https://metadata.un.org/sdg/3","display_name":"Good health and well-being"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":10,"referenced_works":["https://openalex.org/W1989270178","https://openalex.org/W2003632171","https://openalex.org/W2015920709","https://openalex.org/W2074780401","https://openalex.org/W2079222449","https://openalex.org/W2121283937","https://openalex.org/W2168437815","https://openalex.org/W2417610090","https://openalex.org/W4238857688","https://openalex.org/W4243774728"],"related_works":["https://openalex.org/W2409905520","https://openalex.org/W2354749651","https://openalex.org/W2393705164","https://openalex.org/W2297133655","https://openalex.org/W2351623111","https://openalex.org/W330968262","https://openalex.org/W2096763687","https://openalex.org/W2887345745","https://openalex.org/W2410644964","https://openalex.org/W4246519047"],"abstract_inverted_index":{"A":[0],"patient-recorded":[1],"home":[2],"blood":[3,19],"pressure":[4,20],"series":[5],"using":[6],"an":[7],"electronic":[8,38,60,98,145],"manometer":[9,61,68,99,110,162],"is":[10],"used":[11,57],"increasingly":[12],"to":[13,23,116,131,151,154,163],"provide":[14],"a":[15,47,63,70],"representative":[16],"sample":[17],"of":[18,34,123,138],"(BP)":[21],"and":[22,28,44,75,94,102,125],"avoid":[24],"frequent":[25],"office":[26,29],"visits":[27],"rises":[30],"in":[31,120,135,141],"BP.":[32],"Few":[33],"the":[35,55,97,108,147,159],"many":[36],"available":[37],"manometers":[39],"have":[40,52,79],"undergone":[41],"rigorous":[42],"testing":[43],"validation":[45],"against":[46,62],"standard":[48,160],"mercury":[49,67,109,161],"manometer.":[50],"We":[51],"evaluated":[53],"fully":[54],"commonly":[56],"Philips":[58,148],"5306B":[59,149],"Hawksley":[64],"random":[65],"zero":[66],"employing":[69],"randomized,":[71],"single-blind,":[72],"crossover":[73],"design":[74],"statistical":[76],"analyses":[77],"that":[78,105],"been":[80],"validated":[81],"previously.":[82],"Although":[83],"correlation":[84],"coefficients":[85],"greater":[86,112,127],"than":[87,113,128],"0.9":[88],"were":[89],"achieved":[90],"for":[91],"both":[92],"systolic":[93,101],"diastolic":[95,103],"pressure,":[96],"gave":[100],"readings":[104],"differed":[106],"from":[107],"by":[111,126],"or":[114,129],"equal":[115,130],"+/-":[117,132],"5":[118],"mmHg":[119,134],"some":[121,136],"33%":[122],"patients":[124],"1-":[133],"18%":[137],"patients.":[139],"Thus,":[140],"common":[142],"with":[143,158],"most":[144],"manometers,":[146],"needs":[150],"be":[152],"improved":[153],"correlate":[155],"more":[156],"closely":[157],"enhance":[164],"its":[165],"clinical":[166],"usefulness.":[167]},"counts_by_year":[],"updated_date":"2026-10-31T12:09:11.096373","created_date":"2016-06-24T00:00:00"}
