{"id":"https://openalex.org/W1965092001","doi":"https://doi.org/10.1109/epe.2014.6910989","title":"Comparison of electric motor types for realising an energy efficient pumping system","display_name":"Comparison of electric motor types for realising an energy efficient pumping system","publication_year":2014,"publication_date":"2014-08-01","ids":{"openalex":"https://openalex.org/W1965092001","doi":"https://doi.org/10.1109/epe.2014.6910989","mag":"1965092001"},"language":"en","primary_location":{"id":"doi:10.1109/epe.2014.6910989","doi":"https://doi.org/10.1109/epe.2014.6910989","is_oa":false,"landing_page_url":"https://doi.org/10.1109/epe.2014.6910989","pdf_url":null,"source":{"id":"https://openalex.org/S4306418342","display_name":"European Conference on Power Electronics and Applications","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2014 16th European Conference on Power Electronics and Applications","raw_type":"proceedings-article"},"volume":null,"type":"conference-paper","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5039145128","display_name":"Tero Ahonen","orcid":"https://orcid.org/0000-0001-9144-7606","observed_orcids":["https://orcid.org/0000-0001-9144-7606"]},"institutions":[{"id":"https://openalex.org/I63548447","display_name":"Lappeenranta-Lahti University of Technology","ror":"https://ror.org/0208vgz68","country_code":"FI","type":"education","lineage":["https://openalex.org/I63548447"]}],"countries":["FI"],"is_corresponding":false,"raw_author_name":"Tero Ahonen","raw_affiliation_strings":["LAPPEENRANTA UNIVERSITY OF TECHNOLOGY, Lappeenranta, Finland","Lappeenranta University of Technology, P.O.BOX 20, FI-53851, Finland"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"LAPPEENRANTA UNIVERSITY OF TECHNOLOGY, Lappeenranta, Finland","institution_ids":["https://openalex.org/I63548447"]},{"raw_affiliation_string":"Lappeenranta University of Technology, P.O.BOX 20, FI-53851, Finland","institution_ids":["https://openalex.org/I63548447"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5017101487","display_name":"Jussi Tamminen","orcid":"https://orcid.org/0000-0003-4587-605X","observed_orcids":["https://orcid.org/0000-0003-4587-605X"]},"institutions":[{"id":"https://openalex.org/I63548447","display_name":"Lappeenranta-Lahti University of Technology","ror":"https://ror.org/0208vgz68","country_code":"FI","type":"education","lineage":["https://openalex.org/I63548447"]}],"countries":["FI"],"is_corresponding":false,"raw_author_name":"Jussi Tamminen","raw_affiliation_strings":["LAPPEENRANTA UNIVERSITY OF TECHNOLOGY, Lappeenranta, Finland","Lappeenranta University of Technology, P.O.BOX 20, FI-53851, Finland"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"LAPPEENRANTA UNIVERSITY OF TECHNOLOGY, Lappeenranta, Finland","institution_ids":["https://openalex.org/I63548447"]},{"raw_affiliation_string":"Lappeenranta University of Technology, P.O.BOX 20, FI-53851, Finland","institution_ids":["https://openalex.org/I63548447"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5056612282","display_name":"Juho Montonen","orcid":"https://orcid.org/0000-0001-5836-9474","observed_orcids":["https://orcid.org/0000-0001-5836-9474"]},"institutions":[{"id":"https://openalex.org/I63548447","display_name":"Lappeenranta-Lahti University of Technology","ror":"https://ror.org/0208vgz68","country_code":"FI","type":"education","lineage":["https://openalex.org/I63548447"]}],"countries":["FI"],"is_corresponding":false,"raw_author_name":"Juho Montonen","raw_affiliation_strings":["LAPPEENRANTA UNIVERSITY OF TECHNOLOGY, Lappeenranta, Finland","Lappeenranta University of Technology, P.O.BOX 20, FI-53851, Finland"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"LAPPEENRANTA UNIVERSITY OF TECHNOLOGY, Lappeenranta, Finland","institution_ids":["https://openalex.org/I63548447"]},{"raw_affiliation_string":"Lappeenranta University of Technology, P.O.BOX 20, FI-53851, Finland","institution_ids":["https://openalex.org/I63548447"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I63548447"],"apc_list":null,"apc_paid":null,"fwci":0.8029,"has_fulltext":false,"cited_by_count":8,"citation_normalized_percentile":{"value":0.61059468,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":87,"max":97},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"9"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10278","display_name":"Electric Motor Design and Analysis","score":0.9990000128746033,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10278","display_name":"Electric Motor Design and Analysis","score":0.9990000128746033,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10504","display_name":"Sensorless Control of Electric Motors","score":0.00039999998989515007,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13093","display_name":"Electric Power Systems and Control","score":9.999999747378752e-05,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/energy-efficiency","display_name":"energy efficiency","score":0.6589999794960022},{"id":"https://openalex.org/keywords/pumping-systems","display_name":"pumping systems","score":0.9710000157356262},{"id":"https://openalex.org/keywords/induction-motor","display_name":"induction motor","score":0.9670000076293945},{"id":"https://openalex.org/keywords/synchronous-reluctance-motor","display_name":"synchronous reluctance motor","score":0.9620000123977661},{"id":"https://openalex.org/keywords/permanent-magnet-synchronous-motor","display_name":"permanent magnet synchronous motor","score":0.9990000128746033},{"id":"https://openalex.org/keywords/motor-losses","display_name":"motor losses","score":0.796999990940094},{"id":"https://openalex.org/keywords/motor-reliability","display_name":"motor reliability","score":0.8830000162124634},{"id":"https://openalex.org/keywords/motor-sizing","display_name":"motor selection","score":0.574999988079071}],"concepts":[{"id":"https://openalex.org/C12090584","wikidata":"https://www.wikidata.org/wiki/Q4107232","display_name":"Switched reluctance motor","level":3,"score":0.6462857723236084},{"id":"https://openalex.org/C80962145","wikidata":"https://www.wikidata.org/wiki/Q207450","display_name":"Induction motor","level":3,"score":0.6400169134140015},{"id":"https://openalex.org/C176871988","wikidata":"https://www.wikidata.org/wiki/Q72313","display_name":"Electric motor","level":2,"score":0.5552809834480286},{"id":"https://openalex.org/C71376005","wikidata":"https://www.wikidata.org/wiki/Q845675","display_name":"Synchronous motor","level":2,"score":0.5185102224349976},{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.5160319805145264},{"id":"https://openalex.org/C2742236","wikidata":"https://www.wikidata.org/wiki/Q924713","display_name":"Efficient energy use","level":2,"score":0.4919307231903076},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4798511862754822},{"id":"https://openalex.org/C186370098","wikidata":"https://www.wikidata.org/wiki/Q442787","display_name":"Energy (signal processing)","level":2,"score":0.47575849294662476},{"id":"https://openalex.org/C173161252","wikidata":"https://www.wikidata.org/wiki/Q1435839","display_name":"AC motor","level":3,"score":0.47002267837524414},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.38926830887794495},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3675841689109802},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.3601098954677582},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.21512055397033691},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.2118249535560608},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.14119753241539001},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.1372562050819397},{"id":"https://openalex.org/C17281054","wikidata":"https://www.wikidata.org/wiki/Q193466","display_name":"Rotor (electric)","level":2,"score":0.11867403984069824},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/epe.2014.6910989","doi":"https://doi.org/10.1109/epe.2014.6910989","is_oa":false,"landing_page_url":"https://doi.org/10.1109/epe.2014.6910989","pdf_url":null,"source":{"id":"https://openalex.org/S4306418342","display_name":"European Conference on Power Electronics and Applications","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2014 16th European Conference on Power Electronics and Applications","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7","score":0.9090999960899353}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":7,"referenced_works":["https://openalex.org/W191439973","https://openalex.org/W602664560","https://openalex.org/W1558878705","https://openalex.org/W1719144952","https://openalex.org/W2012856026","https://openalex.org/W2111195884","https://openalex.org/W6618482579"],"related_works":["https://openalex.org/W2548805251","https://openalex.org/W2993200413","https://openalex.org/W7020814855","https://openalex.org/W4205663393","https://openalex.org/W2791566486","https://openalex.org/W2924825176","https://openalex.org/W2950052286","https://openalex.org/W3010368728","https://openalex.org/W7111716583","https://openalex.org/W4281932965"],"abstract_inverted_index":{"Energy":[0],"efficiency":[1],"in":[2],"pumping":[3,29,44,92],"is":[4,59,79],"partially":[5],"affected":[6],"by":[7,46],"the":[8,17,34],"electric":[9,19,38],"motor":[10,20,39,48],"efficiency.":[11],"In":[12],"addition":[13],"to":[14,41,80],"low":[15],"losses,":[16],"chosen":[18],"type":[21],"should":[22],"have":[23],"feasible":[24],"reliability":[25],"and":[26,56,68],"dimensions":[27],"for":[28,61,84],"systems.":[30],"This":[31],"paper":[32,78],"studies":[33],"applicability":[35],"of":[36,76],"common":[37],"types":[40],"a":[42,54,62,86],"future":[43],"system":[45],"comparing":[47],"characteristics":[49],"with":[50],"each":[51],"other;":[52],"both":[53],"qualitative":[55],"quantitative":[57],"evaluation":[58],"performed":[60],"15":[63],"kW":[64],"induction,":[65],"synchronous":[66,71],"reluctance":[67],"permanent":[69],"magnet":[70],"motor.":[72],"Another":[73],"main":[74],"object":[75],"this":[77],"provide":[81],"basic":[82],"information":[83],"designing":[85],"next":[87],"generation,":[88],"more":[89],"energy":[90],"efficient":[91],"system.":[93]},"counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2023,"cited_by_count":1},{"year":2021,"cited_by_count":1},{"year":2018,"cited_by_count":3},{"year":2016,"cited_by_count":2}],"updated_date":"2026-11-07T11:25:07.637180","created_date":"2016-06-24T00:00:00"}