{"id":"https://openalex.org/W1963598236","doi":"https://doi.org/10.1109/icices.2013.6508175","title":"A STATCOM-control scheme for wind energy system to improve power quality","display_name":"A STATCOM-control scheme for wind energy system to improve power quality","publication_year":2013,"publication_date":"2013-02-01","ids":{"openalex":"https://openalex.org/W1963598236","doi":"https://doi.org/10.1109/icices.2013.6508175","mag":"1963598236"},"language":"en","primary_location":{"id":"doi:10.1109/icices.2013.6508175","doi":"https://doi.org/10.1109/icices.2013.6508175","is_oa":false,"landing_page_url":"https://doi.org/10.1109/icices.2013.6508175","pdf_url":null,"source":{"id":"https://openalex.org/S4306419548","display_name":"International Conference on Information Communication and Embedded Systems","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2013 International Conference on Information Communication and Embedded Systems (ICICES)","raw_type":"proceedings-article"},"volume":null,"type":"conference-paper","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5013211342","display_name":"N. Nirmala","orcid":"https://orcid.org/0000-0003-3434-2677","observed_orcids":["https://orcid.org/0000-0003-3434-2677"]},"institutions":[{"id":"https://openalex.org/I145286018","display_name":"SRM Institute of Science and Technology","ror":"https://ror.org/050113w36","country_code":"IN","type":"education","lineage":["https://openalex.org/I145286018"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"N. Nirmala","raw_affiliation_strings":["Valliammai Engineering College, Chennai, India","Valliammai Engineering College, SRM Nagar, Chennai, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Valliammai Engineering College, Chennai, India","institution_ids":[]},{"raw_affiliation_string":"Valliammai Engineering College, SRM Nagar, Chennai, India","institution_ids":["https://openalex.org/I145286018"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5100700578","display_name":"Varun Kumar","orcid":"https://orcid.org/0000-0001-8027-5415","observed_orcids":["https://orcid.org/0000-0001-8027-5415"]},"institutions":[{"id":"https://openalex.org/I145286018","display_name":"SRM Institute of Science and Technology","ror":"https://ror.org/050113w36","country_code":"IN","type":"education","lineage":["https://openalex.org/I145286018"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"V. Suresh Kumar","raw_affiliation_strings":["Valliammai Engineering College, Chennai, India","Valliammai Engineering College, SRM Nagar, Chennai, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Valliammai Engineering College, Chennai, India","institution_ids":[]},{"raw_affiliation_string":"Valliammai Engineering College, SRM Nagar, Chennai, India","institution_ids":["https://openalex.org/I145286018"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I145286018"],"apc_list":null,"apc_paid":null,"fwci":3.2582,"has_fulltext":false,"cited_by_count":12,"citation_normalized_percentile":{"value":0.92210939,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":87,"max":97},"biblio":{"volume":null,"issue":null,"first_page":"1108","last_page":"1113"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10573","display_name":"Power Quality and Harmonics","score":0.9599999785423279,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10573","display_name":"Power Quality and Harmonics","score":0.9599999785423279,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10740","display_name":"Wind Turbine Control Systems","score":0.03229999914765358,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14444","display_name":"Power Systems and Renewable Energy","score":0.006200000178068876,"subfield":{"id":"https://openalex.org/subfields/2102","display_name":"Energy Engineering and Power Technology"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/statcom","display_name":"STATCOM","score":0.871999979019165},{"id":"https://openalex.org/keywords/power-quality","display_name":"power quality","score":0.7179999947547913},{"id":"https://openalex.org/keywords/wind-energy-systems","display_name":"wind energy systems","score":0.7870000004768372},{"id":"https://openalex.org/keywords/grid-connected-wind-turbines","display_name":"grid-connected wind turbines","score":0.8270000219345093},{"id":"https://openalex.org/keywords/battery-energy-storage","display_name":"battery energy storage","score":0.9419999718666077},{"id":"https://openalex.org/keywords/reactive-power-compensation","display_name":"reactive power compensation","score":0.9150000214576721},{"id":"https://openalex.org/keywords/point-of-common-coupling","display_name":"point of common coupling","score":0.8169999718666077},{"id":"https://openalex.org/keywords/iec-61400","display_name":"IEC 61400","score":0.9350000023841858},{"id":"https://openalex.org/keywords/voltage-fluctuation","display_name":"voltage fluctuation","score":0.6489999890327454},{"id":"https://openalex.org/keywords/harmonic-distortion-reduction","display_name":"harmonic compensation","score":0.6430000066757202},{"id":"https://openalex.org/keywords/induction-generator","display_name":"induction generator","score":0.7620000243186951}],"concepts":[{"id":"https://openalex.org/C78600449","wikidata":"https://www.wikidata.org/wiki/Q43302","display_name":"Wind power","level":2,"score":0.7318605184555054},{"id":"https://openalex.org/C145180747","wikidata":"https://www.wikidata.org/wiki/Q7236587","display_name":"Power optimizer","level":5,"score":0.6172682046890259},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.5439510345458984},{"id":"https://openalex.org/C108755667","wikidata":"https://www.wikidata.org/wiki/Q1930258","display_name":"AC power","level":3,"score":0.48588675260543823},{"id":"https://openalex.org/C188414643","wikidata":"https://www.wikidata.org/wiki/Q3001183","display_name":"Harmonics","level":3,"score":0.48392540216445923},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.4741750955581665},{"id":"https://openalex.org/C123153844","wikidata":"https://www.wikidata.org/wiki/Q360897","display_name":"Base load power plant","level":4,"score":0.47241559624671936},{"id":"https://openalex.org/C45872418","wikidata":"https://www.wikidata.org/wiki/Q5318966","display_name":"Dynamic demand","level":3,"score":0.4708912968635559},{"id":"https://openalex.org/C64424096","wikidata":"https://www.wikidata.org/wiki/Q750454","display_name":"Power factor","level":3,"score":0.4633164405822754},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.45958226919174194},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.4401000440120697},{"id":"https://openalex.org/C544738498","wikidata":"https://www.wikidata.org/wiki/Q861135","display_name":"Distributed generation","level":3,"score":0.3923366069793701},{"id":"https://openalex.org/C36139824","wikidata":"https://www.wikidata.org/wiki/Q1052007","display_name":"Maximum power point tracking","level":4,"score":0.38775894045829773},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.3749846816062927},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.33931344747543335},{"id":"https://openalex.org/C188573790","wikidata":"https://www.wikidata.org/wiki/Q12705","display_name":"Renewable energy","level":2,"score":0.30368441343307495},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.2752982974052429},{"id":"https://openalex.org/C11190779","wikidata":"https://www.wikidata.org/wiki/Q664575","display_name":"Inverter","level":3,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/icices.2013.6508175","doi":"https://doi.org/10.1109/icices.2013.6508175","is_oa":false,"landing_page_url":"https://doi.org/10.1109/icices.2013.6508175","pdf_url":null,"source":{"id":"https://openalex.org/S4306419548","display_name":"International Conference on Information Communication and Embedded Systems","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2013 International Conference on Information Communication and Embedded Systems (ICICES)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":1.0,"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7"},{"score":0.7207000255584717,"display_name":"Industry, innovation and infrastructure","id":"https://metadata.un.org/sdg/9"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":16,"referenced_works":["https://openalex.org/W164707211","https://openalex.org/W1533552799","https://openalex.org/W1905023496","https://openalex.org/W1991357550","https://openalex.org/W2078871156","https://openalex.org/W2098613258","https://openalex.org/W2100935434","https://openalex.org/W2115175721","https://openalex.org/W2134698607","https://openalex.org/W2151055719","https://openalex.org/W2153292828","https://openalex.org/W2155844138","https://openalex.org/W2161484489","https://openalex.org/W2533204468","https://openalex.org/W2533753311","https://openalex.org/W2984666691"],"related_works":["https://openalex.org/W2101702071","https://openalex.org/W7098673591","https://openalex.org/W2799381052","https://openalex.org/W2336787650","https://openalex.org/W2473880339","https://openalex.org/W2533829075","https://openalex.org/W2188079123","https://openalex.org/W1983505698","https://openalex.org/W2741361957","https://openalex.org/W7218284521"],"abstract_inverted_index":{"Injection":[0],"of":[1,15,28,47,66,73,95,113,172,186,195],"the":[2,10,16,26,31,36,48,52,56,88,99,125,137,150,173,177,182,187,190,196,201,213],"wind":[3,17,49,96,143,153],"power":[4,11,57,89,126,139,158,166,184,206],"into":[5],"an":[6],"electric":[7],"grid":[8,53,151,197,214],"affects":[9],"quality.":[12],"The":[13,45,84,129,145,170,193],"Performance":[14],"turbine":[18,50,97],"and":[19,30,70,76,189,200],"thereby":[20],"pOwer":[21],"quality":[22,58,90,127,159,207],"are":[23,78],"determined":[24],"on":[25,212],"basis":[27],"measurements":[29,59],"norms":[32,208],"followed":[33],"according":[34,80],"to":[35,81,93,123,135],"guideline":[37],"specified":[38],"in":[39,51,165,205],"International":[40],"Electro-technical":[41],"Commission":[42],"standard,":[43],"IEC-61400.":[44],"influence":[46],"system":[54,121,156,167],"concerning":[55],"are-the":[60],"active":[61],"power,":[62,64],"reactive":[63,183],"variation":[65],"voltage,":[67],"flicker,":[68],"harmonics,":[69],"electrical":[71],"behavior":[72],"switching":[74],"operation":[75],"these":[77],"measured":[79],"national/international":[82],"guidelines.":[83],"paper":[85],"study":[86],"demonstrates":[87],"problem":[91],"due":[92],"installation":[94],"with":[98,116],"grid.":[100],"In":[101],"this":[102],"proposed":[103,174],"scheme":[104,148,175,202],"STATIC":[105],"Compensator":[106],"(STATCOM)":[107],"is":[108,133,161],"connected":[109,152],"at":[110],"a":[111,117],"point":[112],"common":[114],"coupling":[115],"battery":[118,130],"energy":[119,131,154],"storage":[120,132],"(BESS)":[122],"mitigate":[124],"issues.":[128],"integrated":[134],"sustain":[136],"real":[138],"source":[140,180],"under":[141],"fluctuating":[142],"power.":[144],"STATCOM":[146],"control":[147],"for":[149,157,203],"generation":[155],"improvement":[160,204],"simulated":[162],"using":[163],"MATLAB/SIMULINK":[164],"block":[168],"set.":[169],"effectiveness":[171],"relives":[176],"main":[178],"supply":[179],"from":[181],"demand":[185],"load":[188],"induction":[191],"generator.":[192],"development":[194],"co-ordination":[198],"rule":[199],"as":[209],"per":[210],"IEC-standard":[211],"has":[215],"been":[216],"presented.":[217]},"counts_by_year":[{"year":2025,"cited_by_count":1},{"year":2022,"cited_by_count":1},{"year":2021,"cited_by_count":1},{"year":2017,"cited_by_count":1},{"year":2016,"cited_by_count":3},{"year":2015,"cited_by_count":2},{"year":2014,"cited_by_count":2},{"year":2013,"cited_by_count":1}],"updated_date":"2026-10-16T09:59:22.235173","created_date":"2016-06-24T00:00:00"}
